Search NASASearch

SEARCH · Search NASA

Results for “Replication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Self-replication of chemical systems based on recognition within a double or a triple helix - A realistic hypothesis

A scenario is proposed for the non-enzymatic self-replication of short RNA molecules. The self-replication of an oligopyrimidine strand is considered and the process of template-directed synthesis based on recognition within a double helix is discussed. Replication mechanisms are suggested for selected oligonucleotides. The mechanisms are based on Watson-Crick base pairing between complementary nucleotides as well as Hoogsteen base pairing between a duplex and the complementary third strand. It is suggested that self-replication based on these mechanisms may be accomplished but may result in a substantial amount of misinformation transfer when mixed oligonucleotides are used.

Kanavarioti, Anastassia

Who or What? Self-Replication and Function-Reproduction in the Origin of Life

In this presentation, we will present results on the fundamental properties of two classes of replicating systems: autocatalytic replicators that reproduce exact copies of a template molecule, and function reproducers that maintain a set of essential functions without replicating the identities of the functional moieties. We will describe the stability and behavior in-the-large of autocatalytic replicators. Most importantly, we have found no sharp distinction between an autocatalytic and a non-autocatalytic domain. We will also present a new derivation of von Kiedrowski's square-root rate law. Function - reproducers are proposed as an important component of protocells and we will present theoretical results on a simple model system that incorporates known peptide biophysics. For a wide range of parameters, we have shown that this type of system can improve its overall performance, even in the absence of any method for information storage. This type of system improvement is defined to be non-genomic evolution.

New, Michael H.

Deterministic Polishing of Replicating Grazing-Incidence Mandrels

In an effort to manufacture high-angular-resolution, grazing-incidence, x-ray optics, Marshall Space Flight Center (MSFC) is taking measures to improve its electroformed replicated optics. A key development is the use of computer-numerical control (CNC) polishing to deterministically improve the surface of electroless nickel mandrels used to replicate grazing- incidence optics. Metrology, control software and polishing parameters must function together seamlessly to reach the specifications required to replicate sub-arcsecond optics. Each change in polishing parameters effects the wear pattern of the polishing head. Using Richardson-Lucy deconvolution, the controller software fits the wear pattern to metrology data to calculate the changing feedrates across the mandrel. Here we present an overview of our process, and early results showing the effectiveness of deterministic polishing for replicated optics.

Davis, Jacqueline

Prebiotic chemistry and nucleic acid replication

Recent work is reviewed on some reactions that could have occurred on the primitive earth and that could have played a part in the evolution of a self-replicating system. The transition from the primitive atmosphere to the simplest replicating molecules is considered in four stages: (1) the formation of a 'prebiotic soup' of organic precursors, including the purine and pyrimidine bases and the pentose sugars; (2) the condensation of these precursors and inorganic phosphate to form monomeric nucleotides and activated nucleotide derivatives; (3) the polymerization of nucleotide derivatives to oligonucleotides; and (4) the complementary replication of oligonucleotides in a template-directed process that depends on Watson-Crick base pairing.

Orgel, L. E.

Management and control of self-replicating systems: A systems model

In 1980, a conceptual engineering approach to self-replicating systems was achieved. The design was based on von Newmann's kinematic version of self-replicating automata. The systems management and control and the organization of the control elements are reported. After developing the functional requirements of such a system, a hierarchy of three management and control levels is described. These are an autonomous, an external, and an intelligent management and control system. Systems recycling, systems specialization, and information replication are discussed.

Vontiesenhausen, G.

Molecular replication

Recent experiments demonstrating nonenzymatic replication in molecular systems are reviewed. The difficulties facing nonenzymatic replication are discussed along with specificity, fidelity, and mutation in nonenzymatic replication. The prospects for research in this area are considered.

Orgel, Leslie E.

Investigate zero-stress replicated optics

The contracted activities for the procurement of 'Investigate Zero-Stress Replicated Optics' to support the AXAF-S x-ray spectrometer mirrors has been completed. To date four large Wolter I grazing incidence x-ray optical shells have been electroformed from nickel. The mirrors were fabricated utilizing each of two nickel alloy plated aluminum substrates twice. A wide variety of testing has been completed by NASA MSFC and UAH. This testing includes heat treatment control tests, subscale plating and fixture testing, alloy control of the electroless nickel, adhesion and release testing of the gold to electroless nickel, electroforming instrumentation and software and fabrication of subscale models. The full scale shells are one millimeter thick nickel electrodeposited over a thin gold layer which in turn has the optical surface on the inside. The optical surface is the replicate of the surface prepared on the substrate. Appendix I briefly outlines the fabrication process. Major objectives which were shared by UAH and MSFC include the design of facilities, equipment and tooling and procurement of materials and equipment. Process development followed with the fabrication of small scale pilot units. Procurement commenced immediately and equipment and materials were ordered to implement the fabrication of first surface full scale substrates (mandrels) and the second surface electroformed optical components. All principal objectives have been achieved. Inspection of the mirrors in visible and x-ray modes validates that the required performance and the quality can be achieved by an electroforming replication process. A very distinct progressive improvement has been achieved with each of the four mirrors produced. The final mirror exceeded the original goals and set an improved standard for flight hardware. The future goal of a 30 arc second resolution at 8 KEV x-ray appears to be achievable by this process when proper cleanliness and process control is utilized.

Engelhaupt, Darell

A novel computational method to simulate non-enzymatic self-replication

Non-enzymatic, template-directed synthesis of oligonucleotides has been extensively studied in the laboratory as a model to understand the kind of chemical processes that might have contributed to the origin of life on Earth. Several oligonucleotides have been shown to catalyze the synthesis of their complements from activated mononucleotides; however, a restricted number of them have been found to self-replicate. Recently we developed an efficient modified cellular automata method that supports the study of self-replicating oligonucleotides. With this method the oligonucleotide molecules are represented as active cells imbedded in a two-dimensional array of inactive cells symbolizing the environment. Random movements and probability-governed chemical reactions occurring in a cellular space can effectively simulate the experimental behavior observed in self-directed replication of oligonucleotides.

Navarro-Gonzalez, Rafael

Development of replicated optics for AXAF-1 XDA testing

Advanced optical systems for applications such as grazing incidence Wolter I x-ray mirror assemblies require extraordinary mirror surfaces in terms of fine finish and surface figure. The impeccable mirror surface is on the inside of the rotational mirror form. One practical method of producing devices with these requirements is to first fabricate an exterior surface for the optical device then replicate that surface to have the inverse component with lightweight characteristics. The replicated optic is not better than the master or mandrel from which it is made. This task identifies methods and materials for forming these extremely low roughness optical components. The objectives of this contract were to (1) prepare replication samples of electroless nickel coated aluminum, and determine process requirements for plating XDA test optic; (2) prepare and assemble plating equipment required to process a demonstration optic; (3) characterize mandrels, replicas and test samples for residual stress, surface contamination and surface roughness and figure using equipment at MSFC and; (4) provide technical expertise in establishing the processes, procedures, supplies and equipment needed to process the XDA test optics.

Engelhaupt, Darell

A Flexible Alignment Fixture for the Fabrication of Replication Mandrels

NASA uses precision diamond turning technology to fabricate replication mandrels for its X-ray Calibration Facility (XRCF) optics. The XRCF optics are tubular, and the internal surface contains a parabolic profile over the first section and a hyperbolic profile over the last. The optic is fabricated by depositing layers of gold and nickel on to the replication mandrel and then separating it from the mandrel. Since the mandrel serves as a replication form, it must contain the inverse image of the surface. The difficulty in aligning the mandrel comes from the fabrication steps which it undergoes. The mandrel is rough machined and heat treated prior to diamond turning. After diamond turning, silicon rubber separators which are undercut in radius by 3 mm (0.12 in.) are inserted between the two end caps of the mandrel to allow the plating to wrap around the ends (to prevent flaking). The mandrel is then plated with a nickel-phosphor alloy using an electroless nickel process. At this point, the separators are removed and the mandrel is reassembled for the final cut on the DTM. The mandrel is measured for profile and finish, and polished to achieve an acceptable surface finish. Wrapping the plating around the edges helps to prevent flaking, but it also destroys the alignment surfaces between the parts of the mandrel that insure that the axes of the parts are coincident. Several mandrels have been realigned by trial-and-error methods, consuming significant amounts of setup time. When the mandrel studied in this paper was reassembled, multiple efforts resulted in a minimum radial error motion of 100 microns. Since 50 microns of nickel plating was to be removed, and a minimum plating thickness of 25 microns was to remain on the part, the radial error motion had to be reduced to less than 25 microns. The mandrel was therefore not usable in its current state.

Cuttino, James F.

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 6.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 0.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 0.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.

Culture in the cockpit: do Hofstede's dimensions replicate?

Survey data collected from 9,400 male commercial airline pilots in 19 countries were used in a replication study of Hofstede's indexes of national culture. The analysis that removed the constraint of item equivalence proved superior, both conceptually and empirically, to the analysis using Hofstede's items and formulae as prescribed, and rendered significant replication correlations for all indexes (Individualism-Collectivism .96, Power Distance .87, Masculinity-Femininity .75, and Uncertainty Avoidance .68). The successful replication confirms that national culture exerts an influence on cockpit behavior over and above the professional culture of pilots, and that "one size fits all" training is inappropriate.

Non-NASA Center

A new method for culturing Plasmodium falciparum shows replication at the highest erythrocyte densities

Plasmodium falciparum replicates poorly in erythrocyte densities greater than a hematocrit of 20%. A new method to culture the major malaria parasite was developed by using a hollow fiber bioreactor that preserves healthy erythrocytes at hematocrit up to 100%. P. falciparum replicated equally well at all densities studied. This method proved advantageous for large-scale preparation of parasitized erythrocytes (and potentially immunogens thereof), because high yields ( approximately 10(10) in 4 days) could be prepared with less cost and labor. Concomitantly, secreted proteins were concentrated by molecular sieving during culture, perhaps contributing to the parasitemic limit of 8%-12% with the 3D7 strain. The finding that P. falciparum can replicate at packed erythrocyte densities suggests that this system may be useful for study of the pathogenesis of fatal cerebral malaria, of which one feature is densely packed blood cells in brain microvasculature.

Plasmodium falciparum/growth & development

Emergence of a replicating species from an in vitro RNA evolution reaction

The technique of self-sustained sequence replication allows isothermal amplification of DNA and RNA molecules in vitro. This method relies on the activities of a reverse transcriptase and a DNA-dependent RNA polymerase to amplify specific nucleic acid sequences. We have modified this protocol to allow selective amplification of RNAs that catalyze a particular chemical reaction. During an in vitro RNA evolution experiment employing this modified system, a unique class of "selfish" RNAs emerged and replicated to the exclusion of the intended RNAs. Members of this class of selfish molecules, termed RNA Z, amplify efficiently despite their inability to catalyze the target chemical reaction. Their amplification requires the action of both reverse transcriptase and RNA polymerase and involves the synthesis of both DNA and RNA replication intermediates. The proposed amplification mechanism for RNA Z involves the formation of a DNA hairpin that functions as a template for transcription by RNA polymerase. This arrangement links the two strands of the DNA, resulting in the production of RNA transcripts that contain an embedded RNA polymerase promoter sequence.

Non-NASA Center

Algorithm-Based Fault Tolerance Integrated with Replication

In a proposed approach to programming and utilization of commercial off-the-shelf computing equipment, a combination of algorithm-based fault tolerance (ABFT) and replication would be utilized to obtain high degrees of fault tolerance without incurring excessive costs. The basic idea of the proposed approach is to integrate ABFT with replication such that the algorithmic portions of computations would be protected by ABFT, and the logical portions by replication. ABFT is an extremely efficient, inexpensive, high-coverage technique for detecting and mitigating faults in computer systems used for algorithmic computations, but does not protect against errors in logical operations surrounding algorithms.

Some, Raphael

Replication of Space-Shuttle Computers in FPGAs and ASICs

A document discusses the replication of the functionality of the onboard space-shuttle general-purpose computers (GPCs) in field-programmable gate arrays (FPGAs) and application-specific integrated circuits (ASICs). The purpose of the replication effort is to enable utilization of proven space-shuttle flight software and software-development facilities to the extent possible during development of software for flight computers for a new generation of launch vehicles derived from the space shuttles. The replication involves specifying the instruction set of the central processing unit and the input/output processor (IOP) of the space-shuttle GPC in a hardware description language (HDL). The HDL is synthesized to form a "core" processor in an FPGA or, less preferably, in an ASIC. The core processor can be used to create a flight-control card to be inserted into a new avionics computer. The IOP of the GPC as implemented in the core processor could be designed to support data-bus protocols other than that of a multiplexer interface adapter (MIA) used in the space shuttle. Hence, a computer containing the core processor could be tailored to communicate via the space-shuttle GPC bus and/or one or more other buses.

Ferguson, Roscoe C.