At least 37 records · Page 2

Icing tunnel tests of a composite porous leading edge for use with a liquid anti-ice system

The efficacy of liquid ice protection systems which distribute a glycol-water solution onto leading edge surfaces through a porous skin was demonstrated in tests conducted in the NASA Lewis icing research tunnel using a composite porous leading edge panels. The data obtained were compared with the performance of previously tested stainless steel leading edge with the same geometry. Results show: (1) anti-ice protection of a composite leading edge is possible for all the simulated conditions tested; (2) the glycol flow rates required to achieve anti-ice protection were generally much higher than those required for a stainless steel panel; (3) the low reservoir pressures of the glycol during test runs indicates that more uniform distribution of glycol, and therefore lower glycol flow rates, can probably be achieved by decreasing the porosity of the panel; and (4) significant weight savings can be achieved in fluid ice protection systems with composite porous leading edges. The resistance of composite panels to abrasion and erosion must yet be determined before they can be incorporated in production systems.

Kohlman, D. L.↗

Functional and performance tests of two capillary pumped loop engineering models

This paper presents the results of the functional and performance tests for two capillary pumped loop (CPL) engineering models. Both CPL systems are aluminum/ammonia transport systems which contain eight parallel evaporators and six parallel condensers in a single loop. Tests conducted include the transport limit, heat load shearing between evaporators, liquid inventory/temperature control by the reservoir, pressure priming under heat load, diode function of condensers, and isolation of a single deprimed evaporator. Consistent performance results were obtained for both systems. Transport capabilities of up to 70 kw-m with individual evaporators managing up to 1.7 kw, with a corresponding input heat flux of 15w/sq cm, were demonstrated. These tests demonstrated the ability of a CPL system to operate over a wide range of conditions and thus established the viability of these systems for high power thermal management of large spacecraft, such as the NASA Space Station.

Ku, J.↗

Positive lubrication system

As part of the development of an autonomous lubrication system for spin bearings, a system was developed to deliver oil to grease-lubricated bearings upon demand. This positive oil delivery system (PLUS) consists of a pressurized reservoir with a built-in solenoid valve that delivers a predictable quantity of oil to the spin bearing through a system of stainless steel tubes. Considerable testing was performed on the PLUS to characterize its performance and verify its effectiveness, along with qualifying it for flight. Additional development is underway that will lead to the fully autonomous active lubrication system.

Smith, Dennis W.↗

Flow characterization in the NASA Ames 16-inch Shock Tunnel

Flow characteristics of NASA's 16-Inch Shock Tunnel are determined for purposes of providing hypersonic propulsion simulation capability. The key tunnel operating parameters are the incident shock speed and reservoir pressure and enthalpy. Flow characteristics of concern are the nozzle exit pressure, temperature, Mach number, Reynolds number, chemical composition, and flow uniformity. Surface mounted gages (for pressure and heat transfer) and nonintrusive optical flow diagnostics (emission and absorption spectroscopy and holographic interferometry) are used to verify tunnel conditions. Experimental measurements are used to validate computational analysis for predicting facility performance, and CFD is used to interpret the free stream optical diagnostic measurements.

Cavolowsky, John A.↗

Performance data of the new free-piston shock tunnel at GALCIT

The new free-piston shock tunnel has been partially calibrated, and a range of operating conditions has been found. A large number of difficulties were encountered during the shake-down period, of which the ablation of various parts was the most severe. Solutions to these problems were found. The general principles of high-enthalpy simulation are outlined, and the parameter space covered by T5 is given. Examples of the operating data show that, with care, excellent repeatability may be obtained. The temporal uniformity of the reservoir pressure is very good, even at high enthalpy, because it is possible to operate at tailored-interface and tuned-piston conditions over the whole enthalpy range. Examples of heat transfer and Pitot-pressure measurements are also presented.

Hornung, Hans G.↗

Thermal effects during loading of vehicle-borne pressurizing gas tanks from reservoir tanks

Two theoretical methods of analyzing the process of filling vehicle-borne, high pressure gas tanks from gas reservoirs are presented. The first method assumes that a given weight of gas at ambient temperature and a specified pressure is required in the vehicle tank and selects a tank volume to exactly accommodate these conditions. The second method assumes the vehicle tank has a given volume and then predicts the temperature overshoot that results from loading a fixed weight of gas to a predetermined pressure and, thereafter, the final gas pressure after the vehicle tank and its contents have returned to ambient temperature. In addition, a means is presented for predicting to what pressure the vehicle tank must be loaded such that, after returning to ambient temperature, it will contain at least the desired weight of gas at the desired pressure.

Wing, L. D.↗

Increase of stagnation pressure and enthalpy in shock tunnels

High stagnation pressures and enthalpies are required for the testing of aerospace vehicles such as aerospace planes, aeroassist vehicles, and reentry vehicles. Among the most useful ground test facilities for performing such tests are shock tunnels. With a given driver gas condition, the enthalpy and pressure in the driven tube nozzle reservoir condition can be varied by changing the driven tube geometry and initial gas fill pressure. Reducing the driven tube diameter yields only very modest increases in reservoir pressure and enthalpy. Reducing the driven tube initial gas fill pressure can increase the reservoir enthalpy significantly, but at the cost of reduced reservoir pressure and useful test time. A new technique, the insertion of a converging section in the driven tube is found to produce substantial increases in both reservoir pressure and enthalpy. Using a one-dimensional inviscid full kinetics code, a number of different locations and shapes for the converging driven tube section were studied and the best cases found. For these best cases, for driven tube diameter reductions of factors of 2 and 3, the reservoir pressure can be increased by factors of 2.1 and 3.2, respectively and the enthalpy can be increased by factors of 1.5 and 2.1, respectively.

Bogdanoff, David W.↗

Partial-Vacuum-Gasketed Electrochemical Corrosion Cell

An electrochemical cell for making corrosion measurements has been designed to prevent or reduce crevice corrosion, which is a common source of error in prior such cells. The present cell (see figure) includes an electrolyte reservoir with O-ring-edged opening at the bottom. In preparation for a test, the reservoir, while empty, is pressed down against a horizontal specimen surface to form an O-ring seal. A purge of air or other suitable gas is begun in the reservoir, and the pressure in the reservoir is regulated to maintain a partial vacuum. While maintaining the purge and partial vacuum, and without opening the interior of the reservoir to the atmosphere, the electrolyte is pumped into the reservoir. The reservoir is then slowly lifted a short distance off the specimen. The level of the partial vacuum is chosen such that the differential pressure is just sufficient to keep the electrolyte from flowing out of the reservoir through the small O-ring/specimen gap. Electrochemical measurements are then made. Because there is no gasket (and, hence, no crevice between the specimen and the gasket), crevice corrosion is unlikely to occur.

Bonifas, Andrew P.↗

Effect of the Reservoir Volume on the Discharge Pressures in the Injection System of the N.A.C.A. Spray Photography Equipment

Tests were made to determine the effect of the reservoir volume on the discharge pressures in the injection system of the N.A.C.A. spray photography equipment. The data obtained are applicable to the design of a common rail fuel-injection system. The data show that an injection system of the type described can be designed so that not more than full load fuel quantity can be injected into the engine cylinders, and so that the fuel spray characteristics remain constant over a large range of engine speeds. Formulas are presented for computing the volume of the reservoir and the diameter of the discharge orifice.

Rothrock, A M↗

Seeding Method for Velocimetry and Visualization of Supersonic Retropropulsion Nozzle Plumes

In the current work, the “Venturi seeder” method for nozzle plumes is improved and studied to determine suitability for particle image velocimetry. This seeding method involves independently pressurizing the primary flow path and a separate seed liquid reservoir, connecting them at the throat of a Venturi contraction upstream of the nozzle. The pressure differential at the throat causes the liquid to enter the nozzle channel where it is atomized into particles by strong shearing forces. This new seeding system was characterized by conducting a series of diagnostics using different exit nozzle pressure ratios and seed reservoir pressures. Shadowgraph imaging confirmed the nozzle plumes to be underexpanded jets. A particle sizing device determined that generated DEHS oil particles had median aerodynamic diameters of 0.67, 0.69, and 0.73 μm for seed liquid reservoir pressure supplies of 0.67, 0.60, and 0.93 MPa and primary flow path pressures of 0.67, 0.76, and 0.93 MPa measured downstream of the Venturi throat, respectively. These diameters were within the threshold for acceptable response time in typical gas flows (≤ 1 μm). PIV experiments were conducted on the nozzle plume for all presented cases; mean axial and transverse velocities appeared as expected for the underexpanded jet structure, including the Mach disk and re-acceleration regions. Additional sizing analysis based on the particle response times across the normal shock again showed particle diameters to be well less than 1 μm for all cases. The results suggest that this method is an inexpensive and relatively simple solution to the problem of seeding nozzle plumes. The method will be used in testing of supersonic retropropulsion models in the Unitary Plan Wind Tunnel at The NASA Langley Research Center in 2022.

particle image velocimetry↗

Experiments with enhanced mode thermionic converters

Reduction of the ionization and scattering losses associated with ignited mode cesium diodes is essential for high thermal-to-electrical conversion efficiency. Use of an auxiliary electrode in conjunction with a noble gas in the interelectrode space should permit more efficient ion generation for space charge neutralization. The characeristics of a thermionic triode utilizing a ring electrode and a dispenser cathode emitter have been studied as a function of xenon pressure, cesium reservoir temperature, spacing, electrode temperature and pulse parameters (i.e., potential, duration and repetition rate) applied to the auxiliary electrode. Pulsed operation significantly enhanced output power with uniform discharges appearing to be sustained at emitter-collector spacings as low as 0.5 mm.

Oettinger, P. E.↗

Validation of the SINDA/FLUINT code using several analytical solutions

The Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA/FLUINT) code has often been used to determine the transient and steady-state response of various thermal and fluid flow networks. While this code is an often used design and analysis tool, the validation of this program has been limited to a few simple studies. For the current study, the SINDA/FLUINT code was compared to four different analytical solutions. The thermal analyzer portion of the code (conduction and radiative heat transfer, SINDA portion) was first compared to two separate solutions. The first comparison examined a semi-infinite slab with a periodic surface temperature boundary condition. Next, a small, uniform temperature object (lumped capacitance) was allowed to radiate to a fixed temperature sink. The fluid portion of the code (FLUINT) was also compared to two different analytical solutions. The first study examined a tank filling process by an ideal gas in which there is both control volume work and heat transfer. The final comparison considered the flow in a pipe joining two infinite reservoirs of pressure. The results of all these studies showed that for the situations examined here, the SINDA/FLUINT code was able to match the results of the analytical solutions.

Keller, John R.↗

Compact and Integrated Liquid Bismuth Propellant Feed System

Operation of Hall thrusters with bismuth propellant has been shown to be a promising path toward high-power, high-performance, long-lifetime electric propulsion for spaceflight missions [1]. There has been considerable effort in the past three years aimed at resuscitating this promising technology and validating earlier experimental results indicating the advantages of a bismuth-fed Hall thruster. A critical element of the present effort is the precise metering of propellant to the thruster, since performance cannot be accurately assessed without an accurate accounting of mass flow rate. Earlier work used a pre./post-test propellant weighing scheme that did not provide any real-time measurement of mass flow rate while the thruster was firing, and makes subsequent performance calculations difficult. The motivation of the present work is to develop a precision liquid bismuth Propellant Management System (PMS) that provides hot, molten bismuth to the thruster while simultaneously monitoring in real-time the propellant mass flow rate. The system is a derivative of our previous propellant feed system [2], but the present system represents a more compact design. In addition, all control electronics are integrated into a single unit and designed to reside on a thrust stand and operate in the relevant vacuum environment where the thruster is operating, significantly increasing the present technology readiness level of liquid metal propellant feed systems. The design of various critical components in a bismuth PMS are described. These include the bismuth reservoir and pressurization system, 'hotspot' flow sensor, power system and integrated control system. Particular emphasis is given to selection of the electronics employed in this system and the methods that were used to isolate the power and control systems from the high-temperature portions of the feed system and thruster. Open loop calibration test results from the 'hotspot' flow sensor are reported, and results of integrated thruster/PMS tests demonstrate operation of the feed system in the relevant environment.

Polzin, Kurt A.↗

Water Membrane Evaporator

A water membrane evaporator (WME) has been conceived and tested as an alternative to the contamination-sensitive and corrosion-prone evaporators currently used for dissipating heat from space vehicles. The WME consists mainly of the following components: An outer stainless-steel screen that provides structural support for the components mentioned next; Inside and in contact with the stainless-steel screen, a hydrophobic membrane that is permeable to water vapor; Inside and in contact with the hydrophobic membrane, a hydrophilic membrane that transports the liquid feedwater to the inner surface of the hydrophobic membrane; Inside and in contact with the hydrophilic membrane, an annular array of tubes through which flows the spacecraft coolant carrying the heat to be dissipated; and An inner exclusion tube that limits the volume of feedwater in the WME. In operation, a pressurized feedwater reservoir is connected to the volume between the exclusion tube and the coolant tubes. Feedwater fills the volume, saturates the hydrophilic membrane, and is retained by the hydrophobic membrane. The outside of the WME is exposed to space vacuum. Heat from the spacecraft coolant is conducted through the tube walls and the water-saturated hydrophilic membrane to the liquid/vapor interface at the hydrophobic membrane, causing water to evaporate to space. Makeup water flows into the hydrophilic membrane through gaps between the coolant tubes.

Ungar, Eugene K.↗

Viscous Effects on Impact Probes in a Subsonic Rarified Gas Flow

The problem of time response of pressure gaging systems used with low density flows has been discussed in Ref ]4, and the effect of outgassing on pressure magnitudes was indicated in the same reference. Briefly, gases or vapors adhering to the internal walls of the pressure gaging system behave like gas sources and produce a pressure rise in the gage system which has no relation to the external flow. The effect can also occur in the reverse direction, with "in-gassing" or the action of an effective sink in the gage system as gases entering through the probe orifice are adsorbed to the walls. For given surface conditions, the magnitude of the pressure error to be expected due to out-gassing depends on the dimensions of the probe system. In the present tests, it was desirable to use the smallest possible probe to yield the lowest possible Reynolds number. The lower limit on size was fixed by outgassing effects, evaluated by the following procedure. 2.0 PROCEDURE The pumping system was adjusted to give a pressure, measured at the reservoir, of 9 microns Hg with no flow into the wind tunnel. The upstream metering valve was then opened and the air flow rate adjusted to give a pressure of 100 microns in the reservoir under steady flow conditions, The pressure read by one of the impact tubes, inserted into the flow, was measured. The upstream metering valve was then closed rapid)y, and the reservoir pressure, p0, and the impact probe pressure, Pj, were measured simultaneously at definite time intervals. Another probe was inserted into the flow and the procedure repeated, until the pressure-time data had been obtained for each probe investigated. The results for a series of tests Involving probe Nos.l, 2 and 3 are shown on HYD 2616 300 RESULTS From HYD 2616, It is clear that the smallest probe (No.3) requires the longest time to reach equilibrium. After a sufficient time has elapsed (about 180 seconds), this probe read the same, within the accuracy of measurement, as the other two, When a similar experiment was performed utilizing a probe which was one-half the size of probe No.2, it indicated a pressure, after 180 seconds, which was almost 10 microns Hg higher than the other probes. Accordingly, only probe Nos. 1, 2, 3 and 4 were employed in the experiments, and a time of at least 180 seconds was allowed to elapse between a change of setting and the reading of the instruments0

Kane, E. D.↗

Making Mars habitable

The possibility is considered that the atmosphere and climate of Mars could be altered to allow terrestrial life forms, and possibly human beings, to survive on the surface. Production of CFCs or other greenhouse gases on Mars would warm the surface enough for the regolith and polar caps to release their CO2 and raise atmospheric pressure to 100 mbar. If a large regolith and polar CO2 reservoirs exist, the pressure would continue to rise on its own. If these are absent, additional CO2 would have to be released from carbonate minerals. At this point, perhaps between 100 and 100,000 yrs, Mars might be suitable for plants. If there is a mechanism for sequestering the reduced carbon, these plants could slowly transform the CO2 to produce an O2-rich atmosphere in perhaps 100,000 yrs. If sufficient N2 could be released from putative soil deposits and the CO2 level could be kept low enough, then a human-breathable atmosphere would be produced.

Mckay, Christopher P.↗

Flows through sequential orifices with heated spacer reservoirs

Flow rates and pressure thermal profiles for two phase choked flows of fluid nitrogen were studied theoretically and experimentally in a four sequential orifice configuration. Both theory and experimental evidence demonstrate that heat addition in the first spacer-reservoir adjacent to the inlet orifice is most effective in reducing the flow rate and that heat addition in the last spacer-reservoir is least effective. The flows are choked at the exit orifice for large spacings and at the inlet orifice for small spacings. The moderate addition of heat available for this experiment did not materially alter this result for large spacings; however, significant heat addition for the small spacings tended to shift the choke point to the exit orifice. Nitrogen is used as the working fluid over a range of states from liquid to gas with a reduced inlet stagnation pressure range to P sub r, o = 2.

Hendricks, R. C.↗