Search NASA⌕ Search

SEARCH · Search NASA

Results for “Residual Heat Removal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Carbon Nanotube Purification

A method for cleaning or otherwise removing amorphous carbon and other residues that arise in growth of a carbon nanotube (CNT) array. The CNT array is exposed to a plurality of hydroxyls or hydrogen, produced from a selected vapor or liquid source such as H2O or H2O2. and the hydroxyls or hydrogen (neutral or electrically charged) react with the residues to produce partly or fully dissolved or hydrogenated or hydroxylizated products that can be removed or separated from the CNT array. The hydroxyls or hydrogen can be produced by heating the CNT array, residue and selected vapor or liquid source or by application of an electromagnetic excitation signal with a selected frequency or range of frequencies to dissociate the selected vapor or liquid. The excitation frequency can be chirped to cover a selected range of frequencies corresponding to dissociation of the selected vapor or liquid. Sonication may be uscd to supplement dissociation of the H2O and/or H2O2.

Delzeit, Lance D.↗

Reinforcing the exit hole from friction stir welding and processing

After friction stir welding/processing (FSW/P), an exit hole remains at the end of the run, which can be the weakest region of the welded/processed workpiece. In addition, tensile residual stress around the exit hole resulting from heating during FSW/P facilitates incipient crack initiating from the exit hole under external loading. Current solutions include removing or repairing the exit hole, which are time-consuming and costly. Here, we propose a novel method to reinforce the exit hole by applying an additional FSW/P pass around it, in a way that replaces preexisting tensile residual stress with compressive residual stress. Under external loading, there is no evident strain accumulation around the exit hole, and the workpiece ultimately fails along the FSW/P heat affected zone. This method provides a more convenient way to reinforce the exit hole than the current exit-hole repair or removal methods for industrial applications.

36 MATERIALS SCIENCE↗

Thermal Design Challenges Posed by the Four Bed CO2 Scrubber COTS Air-Save Pump

The Four Bed Carbon Dioxide (4BCO2) scrubber Air-Save Pump (ASP) operates as part of the adsorbent bed regeneration cycle. The ASP removes residual air from the bed for return to the cabin prior to heat and vacuum exposure which drives out the CO2 regenerating the bed. 4BCO2 employs a Commercial Off-the-Shelf (COTS) scroll type air pump, repackaged in an acoustically insulated enclosure to reduce noise and mounted to a cold plate. The International Space Station (ISS) Low Temperature Loop (LTL) flow (operating between 38°F and 50°F) first cools the process air, and then flows through the cold plate, cooling the pump. This results in competing ASP thermal design goals: (1) to keep the pump and motor sufficiently cool and (2) to avoid forming condensation due to over-cooling. Surfaces below 60°F typically warrant careful consideration of condensation. A test-calibrated thermal model demonstrates such a balanced design is feasible with temperatures above 60°F. A separate, coupled fluid model predicts the potential for condensation formation, allowing risk assessment of flying with the unmodified design.

Daniel P Popok↗

Bonding machine for forming a solar array strip

A machine is described for attaching solar cells to a flexable substrate on which printed circuitry has been deposited. The strip is fed through: (1) a station in which solar cells are elevated into engagement with solder pads for the printed circuitry and thereafter heated by an infrared lamp; (2) a station at which flux and solder residue is removed; (3) a station at which electrical performance of the soldered cells is determined; (4) a station at which an encapsulating resin is deposited on the cells; (5) a station at which the encapsulated solar cells are examined for electrical performance; and (6) a final station at which the resulting array is wound on a takeup drum.

Costogue, E. N.↗

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine↗

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water↗

Joining of Nickel and Nickel-Base Alloys

Nickel and nickel- base alloys are amenable to joining with many of the familiar joining processes. Some new joining processes also have been used successfully. In general, conventional joining procedures are used with only slight required modifications, depend­ing on the particular alloy to be welded. However, some special precautions must be taken. Harmful materials must be removed from the joint or surrounding areas or they may damage the weld and the nearby heated parent metal. Some high-strength age­ hardenable alloys are prone to cracking in or near joint areas, unless the material is in the proper condition of heat treatment prior to joining operations. Foreign material and flux residues left from joining operations can cause trouble in subsequent service if not removed. Procedures for joining these alloys have been developed that eliminate or minimize the usual difficulties that have been experienced. When proper procedures are employed, joining of nickel and nickel- base alloys can be performed satisfactorily.

Vagi, J. J.↗

Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal

A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.

Klausner, James F.↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

Residual Gas in Closed Systems. III: Development and Reduction of Gases Generated by Source Materials

The amounts and composition of residual gases formed in sealed ampoules loaded with different sources (elements and II-VI and IV-VI compounds) after consecutive annealings were investigated. A given source was subjected to a series of heat treatments, with intermediate measurements and removal of the gas accumulated in the system. The results of these experiments are discussed in terms of the underlying thermochemical and kinetic phenomena and practical limitations of reducing the amount of residual gases in sealed ampoules.

Palosz, W.↗

High-efficiency frost and ice control via sensing-assisted nanovibrational slippery surfaces

Frost and ice accretions on surfaces pose persistent challenges across numerous industrial, residential and transportation systems. While various removal strategies exist, they often suffer from limited effectiveness or high energy consumption, such as frosting delay, ice crack generation, and Joule heating. Here, in this work, we report a novel integrated approach combining vibrational quasi-liquid surface (QLS) and capacitive sensing for efficient condensate, frost, and ice management. Compared to Joule heating, our approach does not rely on complete melting and evaporation for removal, resulting in 68% and 95% energy savings for frost and ice removal, respectively. Our QLS coating significantly reduces surface retention forces, achieving 91% and 87% less residual mass compared to hydrophilic surfaces for frost and ice removal through surface nanovibration, respectively. The integrated capacitive sensor provides real-time detection of different phase states, enabling on-demand removal in precise timeframes. This sensor-assisted approach showed 3.8 times lower energy consumption compared to conventional Joule heating for defrosting. This synergistic integration of surface engineering, nanovibration, and intelligent sensing represents a significant advancement in phase change processes, offering an energy-efficient solution for frost and ice mitigation in energy-intensive systems.

Shen, Yuchen [Univ. of Texas at Dallas, Richardson↗

Recovery, Transportation and Acceptance to the Curation Facility of the Hayabusa Re-Entry Capsule

The "Hayabusa" re-entry capsule was safely carried into the clean room of Sagamihara Planetary Sample Curation Facility in JAXA on June 18, 2010. After executing computed tomographic (CT) scanning, removal of heat shield, and surface cleaning of sample container, the sample container was enclosed into the clean chamber. After opening the sample container and residual gas sampling in the clean chamber, optical observation, sample recovery, sample separation for initial analysis will be performed. This curation work is continuing for several manths with some selected member of Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). We report here on the 'Hayabusa' capsule recovery operation, and transportation and acceptance at the curation facility of the Hayabusa re-entry capsule.

Abe, M.↗

On-Orbit Xenon Refueling Loading Times and Transient Analysis

The Power and Propulsion Element (PPE) of the Lunar Orbital Platform-Gateway will demonstrate the first on-orbit refueling of xenon propellant for a solar electric propulsion system. An analysis was performed in Microsoft Excel to determine what factors influence the overall refueling time of a single 2,000-kilogram capacity xenon propellant tank, as well as provide estimates for overall refueling duration. Due to the high heat of compression of xenon, the propellant tank could exceed its maximum allowable temperature during refueling if the xenon flow rate and temperature are unregulated. In order to prevent overheating, a logic based "bang-bang" operation was used for refueling, shutting off the mass feed when the tank reached a maximum temperature. Heat is removed from the tank via radiation to the surrounding spacecraft bus. The analysis shows that optimizing key parameters such as mass flow rate into the tank, residual propellant in the tank during the onset of refueling, and tank diameter significantly reduces the overall refueling duration. Optimization is not straightforward, however, as the loading time does not trend monotonically with the parameters. Overall, the most significant impact on loading duration comes from altering the residual propellant in the tank. Increasing the mass of residual propellant from 2 percent to 20 percent reduces the overall refueling duration by 56 percent. Future work based on this analysis includes creation of a SINDA/FLUINT model and building a ground-based xenon refueling system emulator.

Xenon↗

High Energy Cutting and Stripping Utilizing Liquid Nitrogen

The Aerospace Industry has endeavored for decades to develop hybrid materials that withstand the rigors of mechanized flight both within our atmosphere and beyond. The development of these high performance materials has led to the need for environmentally friendly technologies for material re-work and removal. The NitroJet(TM) is a fluid jet technology that represents an evolution of the widely used, large-scale water jet fluid jet technology. It involves the amalgamation of fluid jet technology and cryogenics technology to create a new capability that is applicable where water jet or abrasive jet (water jet plus entrained abrasive) are not suitable or acceptable because of technical constraints such as process or materials compatibility, environmental concerns and aesthetic or legal requirements. The NitroJet(TM) uses ultra high-pressure nitrogen to cut materials, strip numerous types of coatings such as paint or powder coating, clean surfaces and profile metals. Liquid nitrogen (LN2) is used as the feed stream and is pressurized in two stages. The first stage pressurizes sub cooled LN2 to an intermediate pressure of between 15,000 and 20,000 psi at which point the temperature of the LN2 is about -250 F. The discharge from this stage is then introduced as feed to a dual intensifier system, which boosts the pressure from 15,000 - 20,000 psi up to the maximum operating pressure of 55,000 psi. A temperature of about -220 F is achieved at which point the nitrogen is supercritical. In this condition the nitrogen cuts, strips and abrades much like ultra high-pressure water would but without any residual liquid to collect, remove or be contaminated. Once the nitrogen has performed its function it harmlessly flashes back into the atmosphere as pure nitrogen gas. The system uses heat exchangers to control and modify the temperature of the various intake and discharge nitrogen streams. Since the system is hydraulically operated, discharge pressures can be easily varied over a very wide range providing considerable flexibility for various operations. The NitroJet(TM) is an advance on the nitrogen fluid jet technology initially developed at the Idaho National Engineering Laboratory in Idaho Falls, Idaho. NitroCision(R) first introduced the NitroJet(TM) into a commercial setting in 2003 and there has been considerable interest from many diverse sectors of government and industry since then. While the current system is an industrial system with the size and mass normally associated with industrial applications, a smaller system that is much more compact is being contemplated for those applications that do not need the full capabilities of the larger system. The NitroJet(TM) can be deployed as a fixed or mobile system with multiple end effectors capable of cutting, stripping, cleaning, and surface profiling either in robotic or manual applications.

Hume, Howard↗

Study of the Residual Background Events in Ground Data from the ASTRO-HSXS Microcalorimeter

The measured instrumental background of the XRS calorimeter spectrometer of Suzaku had several sources, including primary cosmic rays and secondary particles interacting with the pixels and with the silicon structure of the array. Prior to the launch of Suzaku, several data sets were taken without x-ray illumination to study the characteristics and timing of background signals produced in the array and anti-coincidence detector. Even though the source of the background in the laboratory was different from that in low-earth orbit (muons and environmental gamma-rays on the ground versus Galactic cosmic-ray (GCR) protons and alpha particles in space), the study of correlations and properties of populations of rare events was useful for establishing the preliminary screening parameters needed for selection of good science data. Sea-level muons are singly charged minimum-ionizing particles, like the GCR protons, and thus were good probes of the effectiveness of screening via the signals from the anti-coincidence detector. Here we present the first analysis of the on-ground background of the SXS calorimeter of Astro-H. On XRS, the background prior to screening was completely dominated by coincident events on many pixels resulting from the temperature pulse arising from each large energy deposition (greater than 200 keV) into the silicon frame around the array. The improved heat-sinking of the SXS array compared with XRS eliminated these thermal disturbances, greatly reducing the measured count rate in the absence of illumination. The removal of these events has made it easier to study the nature of the residual background and to look for additional event populations. We compare the SXS residual background to that measured in equivalent ground data for XRS and discuss these preliminary results.

ASTRO-H↗

Modeling Radiolysis and Chemical Reactions during Dry Storage of Aluminum-clad Spent Nuclear Fuel

After aluminum-clad spent nuclear fuel (ASNF) is removed from the reactor, it is initially stored in spent fuel pools, which are specially designed water-filled basins that provide temporary cooling to reduce the temperature of the fuel assemblies and provide radiation shielding. ASNF continues to generate heat due to the radioactive decay of elements within the fuel, which persists for many years post-shutdown as the residual radioactive products decay into more stable elements. During the wet storage period, an oxyhydroxide layer composed of boehmite/bayerite forms on the surfaces of the aluminum cladding from exposure to water in the pools. Road-ready packaging for long-term disposition of the ASNF involves dry storage in helium backfilled DOE standard canisters (DSCs). When the ASNF is removed from water storage and dried, most of the water is removed, but some physisorbed and chemisorbed water remains in the oxyhydroxide layers. This residual water can produce hydrogen when exposed to radiation from the ASNF during dry storage. Predicting hydrogen accumulation over time in the DSCs is critical for long-term storage considerations. Previous modeling efforts have developed coupled computational fluid dynamics (CFD)-chemical models to simulate temperature, pressure, and gas phase concentrations within the DSCs. These models use the thermal field predicted by CFD as input to a radiolysis model for the gas phase and the surface oxyhydroxide layer chemistry. Given the long storage period of the DSCs and the impracticality of long-term experiments, a simulation-based approach is necessary to assess chemical evolution within the canisters. This study advances the development of a modeling framework designed to simulate the chemical evolution of spent fuel canisters. Both thermal and radiation-driven reactions are considered, with radiation kinetics quantified using G-values. Sensitivity analysis identifies key parameters influencing species composition. Reaction pathway diagrams offer insight into dominant species formation routes, enabling more effective comparisons between model predictions and experimental observations, particularly regarding the production of hydrogen. Results show that the model predicts significant hydrogen gas production with minimal oxygen generation, primarily due to hydrogen formation via boehmite pathways. These findings underscore the importance of accurately characterizing surface-bound species and radiolysis kinetics. A deeper understanding of these mechanisms is critical for evaluating the long-term safety of nuclear waste storage.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗