Measure Guideline: Condensing Boilers—Control Strategies for Optimizing Performance and Comfort in Residential Applications

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called "combi" systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Processed data from the Building Management System for the System Engineering Building.

The dataset spans November 2018 to May 2020 and includes time-series measurements corresponding to supply and return temperatures of air and water, air, hot water and cold water flow rates, energy and power consumption, set-points etc. as a single CSV file. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-contained heat rejection module for future spacecraft

This paper discusses development of a Self-Contained Heat Rejection Module (SHRM) which can be used on a wide variety of future spacecraft launched by the space shuttle orbiter. The SHRM contains radiators which are deployed by a scissor-mechanism and the flow equipment including pumps, accumulator, by-pass valves, and controllers necessary to reject heat from those radiators. Heat transfer between SHRM and the parent vehicle is effected by a contact heat exchanger. This device provides heat transfer between two separate flow loops through a mechanical connection. This approach reduces the time required to attach the SHRM to the payload, and increases the reliability of the SHRM flow loop since breaking into the fluid system in the field is not required. The SHRM concept also includes a refrigeration system to increase heat rejection capacity in adverse environments, or to provide for a lower return temperature, down to -23 C.

Fleming, M. L.↗

Development testing of a self-contained heat rejection module

This paper discusses the thermal vacuum testing of a Self-Contained Heat Rejection Module (SHRM) currently being developed for use with Shuttle payloads and future spacecraft. Two weeks of testing were conducted in the NASA Johnson Space Center Space Environment Simulator Laboratory in October and November of 1975. The testing included demonstration of deployable spacecraft radiators with fluid swivels, variable return temperatures, and a dual-mode pumped fluid radiator/vapor compression refrigeration system. In addition, an evaluation was made of a contact heat exchanger used as the intercooler. The test articles and systems are described and the test planning and objectives discussed. A summary of the significant results of the testing and conclusions drawn from the testing are presented.

Fleming, M. L.↗

Mars Pathfinder Wheel Abrasion Experiment Ground Test

The National Aeronautics and Space Administration (NASA) sent a mission to the martian surface, called Mars Pathfinder. The mission payload consisted of a lander and a rover. The primary purpose of the mission was demonstrating a novel entry, descent, and landing method that included a heat shield, a parachute, rockets, and a cocoon of giant air bags. Once on the surface, the spacecraft returned temperature measurements near the Martian surface, atmosphere pressure, wind speed measurements, and images from the lander and rover. The rover obtained 16 elemental measurements of rocks and soils, performed soil-mechanics, atmospheric sedimentation measurements, and soil abrasiveness measurements.

Keith, Theo G., Jr.↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Lunar Surface temperatures can span from equatorial highs near 400K and polar lows of 50K. The extreme cold combined with the 354-hour duration of the lunar night is particularly challenging for small robotic lander missions. NASA’s Commercial Lunar Payload Services (CLPS) missions involve robotic landers intended to provide low-cost access to the lunar surface. Current CLPS Missions are solar powered and are only intended to survive a single lunar day. The ability to survive the night and continue operations over many lunar cycles would provide a dramatic increase in science productivity. The Power Hibernation approach relies on battery cells that can tolerate the extreme cold night and recover once temperatures return to normal. System recovery from hibernation depends on power electronics that can “cold start” at lunar dawn and operate on solar array output alone. Once battery and avionics systems are restored the spacecraft resumes daytime operations. The challenge is to achieve this capability with minimum impact to the spacecraft design and payload capacity. This talk will describe recent and ongoing investigations in battery and electronics technologies that will enable power hibernation and recovery.

Space Power↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Lunar Surface temperatures can span from equatorial highs near 400K and polar lows of 50K. The extreme cold combined with the 354-hour duration of the lunar night is particularly challenging for small robotic lander missions. NASA’s Commercial Lunar Payload Services (CLPS) missions involve robotic landers intended to provide low-cost access to the lunar surface. Current CLPS Missions are solar powered and are only intended to survive a single lunar day. The ability to survive the night and continue operations over many lunar cycles would provide a dramatic increase in science productivity. The Power Hibernation approach relies on battery cells that can tolerate the extreme cold night and recover once temperatures return to normal. System recovery from hibernation depends on power electronics that can “cold start” at lunar dawn and operate on solar array output alone. Once battery and avionics systems are restored the spacecraft resumes daytime operations. The challenge is to achieve this capability with minimum impact to the spacecraft design and payload capacity. This talk will describe recent and ongoing investigations in battery and electronics technologies that will enable power hibernation and recovery.

Space Power↗

Recommended Maximum Temperature For Mars Returned Samples

The Returned Sample Science Board (RSSB) was established in 2015 by NASA to provide expertise from the planetary sample community to the Mars 2020 Project. The RSSB's first task was to address the effect of heating during acquisition and storage of samples on scientific investigations that could be expected to be conducted if the samples are returned to Earth. Sample heating may cause changes that could ad-versely affect scientific investigations. Previous studies of temperature requirements for returned mar-tian samples fall within a wide range (-73 to 50 degrees Centigrade) and, for mission concepts that have a life detection component, the recommended threshold was less than or equal to -20 degrees Centigrade. The RSSB was asked by the Mars 2020 project to determine whether or not a temperature requirement was needed within the range of 30 to 70 degrees Centigrade. There are eight expected temperature regimes to which the samples could be exposed, from the moment that they are drilled until they are placed into a temperature-controlled environment on Earth. Two of those - heating during sample acquisition (drilling) and heating while cached on the Martian surface - potentially subject samples to the highest temperatures. The RSSB focused on the upper temperature limit that Mars samples should be allowed to reach. We considered 11 scientific investigations where thermal excursions may have an adverse effect on the science outcome. Those are: (T-1) organic geochemistry, (T-2) stable isotope geochemistry, (T-3) prevention of mineral hydration/dehydration and phase transformation, (T-4) retention of water, (T-5) characterization of amorphous materials, (T-6) putative Martian organisms, (T-7) oxidation/reduction reactions, (T-8) (sup 4) He thermochronometry, (T-9) radiometric dating using fission, cosmic-ray or solar-flare tracks, (T-10) analyses of trapped gasses, and (T-11) magnetic studies.

Beaty, D. W.↗

Active and Passive Storage Solutions for Low Temperature Lunar Sample Return

Active and passive thermal storage solutions to return lunar biological, physical science and/or geology samples to the Earth are under development. Temperature requirements for biological/physical science sample conditioning range from -100˚C to -153˚C and possibly down to -253˚C for geological samples. The lower limit for geological samples is derived from the temperature of permanently shadowed regions on the lunar surface and the sublimation temperature of specific volatiles of interest (i.e., H2O, NH3 and CH4). Individual samples for the lunar application are expected to be less than 50 kg with a 700 kg allowance for the container and refrigeration. Requiring no electrical power or heat rejection, passive approaches, comprised of high performance insulation and consumable Joule-Thompson cooling, may be preferred for shorter duration missions (< 30 days) to provide significant mass savings. Active storage approaches with cryogenic cooling may be necessary to preserve samples for longer periods of time. A notional passive storage concept with an internal vapor cooled shield is shown below. The vapor cooled shield contains the sample and is isolated from the outer container with concentric reflective rigid shields and conventional multi-layer and/or aerogel insulation on the outer layer. A special removable, insulating end cap to stow or retrieve the sample is included.

Lunar Sample Return↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

RELAP5-3D Transient Modelling for NGNP Integrated Plant

The High-Temperature Gas-cooled Reactor (HTGR) is designed with outlet temperatures ranging between 750°C and 800°C. These high outlet temperatures enhance the power production efficiency and facilitate a variety of industrial applications. The objective of this study is to understand the response of the primary system to potential transients in the secondary system. For this analysis, the transient condition originates in the Intermediate Heat Exchanger (IHX) or Steam Generator (SG) of the HTGR-integrated plant. The transients analysed are: a loss of pressure; loss of feedwater flow; inadvertent closure of main steam valve; decrease in returning gas temperature and heat load step change. The results show a large dependence on the negative reactivity added to the fuel as a function of increased temperature. The returning gas temperature decrease transient resulted in the highest fuel temperature (1361°C). Fuel temperature was shown to be less than the 1600°C fuel limit for each case analysed.

42 ENGINEERING↗

Maximum Sample Temperature for Mars Sample Return: A Historical Perspective

Since the first Mars Sample Return (MSR) report published by the Jet Propulsion Laboratory (JPL) in 1974 [1], a series of panels, reports, and white papers have recognized the importance of sample temperature and offered an informed sample maximum temperature (henceforth SMT) limit for returning martian samples to Earth. The Mars Sample Handling and Requirements Panel (MSHARP, 1999) stated that "[t]he main issue in sample preservation is temperature" [2]. More recently, the Mars Exploration Program Analysis Group (MEPAG)'s "Science Priorities for Mars Sample Return" report (2008), declared that "[s]ignificant loss, particularly to biological studies, occurs if samples reach +50C for three hours", whereby "scientific objectives related to life goals could be seriously compromised" [3]. By contrast, the Mars 2020 mission has adopted a SMT of +60C as spelled out in Beaty et al., 2016 [4]. Samples will be collected and then deposited on the surface in sealed tubes for possible retrieval and return to Earth. Beaty et al. [4] calculates that the samples will experience maximum temperatures of ~+30 to +60C, depending on latitude. At present, there is no mission requirement for the measurement/data logging of sample temperature during this period. We will explore the history of martian SMTs, as they have been recorded since 1974 [1], effectively representing input across multiple generations of Mars scientists. Ten separate publications present SMTs for MSR samples [1-10]. One report [10] is for a mission concept specifically designed to exclude life detection investigations, and recommended an SMT of 50C. Another did not specify a temperature, recommending "Mars ambient temperature" [5]. Of the remaining eight, SMTs are given as: -30C [1], -20C [3], 60C [4], -73 to 41C depending on sample type [6], -40C [7], -43 to 13C depending on type [2,8], and -33C [9]. If we restrict the temperatures to samples highlighted in the Mars 2020 mission goals, i.e. organics-bearing and sedimentary rocks, then the average SMT is -28+/-39C (n=8). Applying a Dixon's Q Test at P=0.05 (two-tailed), the 60C SMT [4] fails with Q=0.602 versus Qcrit=0.526. Excluding the outlier produces an average SMT of -40+/-17C (n=7). Therefore, the average SMT expressed by the Mars science community over the past 44 years (two generations) is a sample temperature no greater than -40C. The difference in chemical reaction rates between this average SMT and Beaty et al [4] can be estimated using the Arrhenius equation. Assuming a generic chemical reaction with an activation energy of 50 kJ/mol and a pre-exponential factor invariant with temperature, this reaction will proceed 2300x faster at 60C than at -40C. To illustrate the effects of the increased reaction rate, consider 10 ppb of alanine in a Mars 2020 cache, and assume that it becomes unmeasurable if it degrades to 1 ppb, as per the Mars 2020 Organic Contamination Panel contamination limits [11]. If we illustrate the effect with an arbitrary degradation rate such that the alanine will become undetectable in ten years at -40C, then the same 10 ppb alanine degrades beyond detectability in only 38 days at 60C. Further research is required to quantify expected analyte losses in the cached samples due to thermal processing.

Fries, Marc↗

Data for A Role for Differential Rubisco Activase Isoform Expression in C4 Bioenergy Grasses at High Temperature

Rubisco activase (Rca) facilitates the release of sugar-phosphate inhibitors at Rubisco catalytic sites during CO2 fixation. Most plant species express two Rca isoforms, the larger Rca-α and the shorter Rca-β, either by alternative splicing from a single gene or expression from separate genes. The mechanism of Rubisco activation by Rca isoforms has been intensively studied in C3 plants. However, the functional role of Rca in C4 plants where Rubisco and Rca are located in a much higher [CO2] compartment is less clear. In this study, we selected four C4 bioenergy grasses and the model C4 grass setaria ( Setaria viridis ) to investigate the role of Rca in C4 photosynthesis. All five C4 grass species contained two Rca genes, one encoding Rca-α and the other Rca-β, which were positioned closely together in the genomes. A variety of abiotic stress-related motifs were identified in the Rca-α promoter of each grass, and while the Rca-β gene was constantly highly expressed at ambient temperature, Rca-α isoforms were expressed only at high temperature but never surpassed 30% of Rca-β content. The pattern of Rca-α induction on transition to high temperature and reduction on return to ambient temperature was the same in all five C4 grasses. In sorghum ( Sorghum bicolor ), sugarcane ( Saccharum officinarum ), and setaria, the induction rate of Rca-α was similar to the recovery rate of photosynthesis and Rubisco activation at high temperature. This association between Rca-α isoform expression and maintenance of Rubisco activation at high temperature suggests that Rca-α has a functional thermo-protective role in carbon fixation in C4 grasses by sustaining Rubisco activation at high temperature.

Genomics↗

Magnetic Properties of Fe-49Co-2V Alloy and Pure Fe at Room and Elevated Temperatures

The National Aeronautics and Space Administration (NASA) has a need for soft magnetic materials for fission power and ion propulsion systems. In this work the magnetic properties of the soft magnetic materials Hiperco 50 (Fe-49wt%Cr-2V) and CMI-C (commercially pure magnetic iron) were examined at various temperatures up to 600 C. Toroidal Hiperco 50 samples were made from stacks of 0.35 mm thick sheet, toroidal CMI-C specimens were machined out of solid bar stock, and both were heat treated prior to testing. The magnetic properties of a Hiperco 50 sample were measured at various temperatures up to 600 C and then again after returning to room temperature; the magnetic properties of CMI-C were tested at temperatures up to 400 C. For Hiperco 50 coercivity decreased as temperature increased, and remained low upon returning to room temperature; maximum permeability improved (increased) with increasing temperature and was dramatically improved upon returning to room temperature; remanence was not significantly affected by temperature; flux density at H = 0.1 kA/m increased slightly with increasing temperature, and was about 20% higher upon returning to room temperature; flux density at H = 0.5 kA/m was insensitive to temperature. It appears that the properties of Hiperco 50 improved with increasing temperature due to grain growth. There was no significant magnetic property difference between annealed and aged CMI-C iron material; permeability tended to decrease with increasing temperature; the approximate decline in the permeability at 400 C compared to room temperature was 30%; saturation flux density, B(sub S), was approximately equal for all temperatures below 400 C; B(sub S) was lower at 400 C.

De Groh, Henry C., III↗