Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reuse Distance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

2012 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2011 through October 31, 2012. The report contains the following information: • Facility and system description, • Permit required effluent monitoring data and loading rates, • Groundwater monitoring data, • Status of compliance activities, • Noncompliance issues, and • Discussion of the facility’s environmental impacts. During the 2012 permit year, approximately 183 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

2012 wastewater reuse report↗

2010 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2009 through October 31, 2010. The report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Groundwater monitoring data • Status of compliance activities • Discussion of the facility’s environmental impacts During the 2010 permit year, approximately 164 million gallons of wastewater were discharged to the Cold Waste Pond. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

99 GENERAL AND MISCELLANEOUS↗

2011 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Pond from November 1, 2010 through October 31, 2011. The report contains the following information: Facility and system description Permit required effluent monitoring data and loading rates Groundwater monitoring data Status of compliance activities Noncompliance and other issues Discussion of the facility's environmental impacts During the 2011 permit year, approximately 166 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters were below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

2011 Annual Industrial Wastewater Reuse Report↗

Hierarchical probing for estimating the trace of the matrix inverse on toroidal lattices

The standard approach for computing the trace of the inverse of a very large, sparse matrix $A$ is to view the trace as the mean value of matrix quadratures, and use the Monte Carlo algorithm to estimate it. This approach is heavily used in our motivating application of Lattice QCD. Often, the elements of $A^{-1}$ display certain decay properties away from the non zero structure of $A$, but random vectors cannot exploit this induced structure of $A^{-1}$. Probing is a technique that, given a sparsity pattern of $A$, discovers elements of $A$ through matrix-vector multiplications with specially designed vectors. In the case of $A^{-1}$, the pattern is obtained by distance-$k$ coloring of the graph of $A$. For sufficiently large $k$, the method produces accurate trace estimates but the cost of producing the colorings becomes prohibitively expensive. More importantly, it is difficult to search for an optimal $k$ value, since none of the work for prior choices of $k$ can be reused.

Stathopoulos, Andreas↗

2013 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (#LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2012–October 31, 2013. The report contains the following information: (1) Facility and system description; (2) Permit required effluent monitoring data and loading rates • Groundwater monitoring data; (3) Status of compliance activities; (4) Noncompliance issues; and (5) Discussion of the facility’s environmental impacts. During the 2013 permit year, approximately 238 million gallons of wastewater was discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the down gradient monitoring wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2014 Annual Industrial Wastewater Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond

This report describes conditions, as required by the state of Idaho Industrial Wastewater Reuse Permit (LA 000161 01, Modification B), for the wastewater land application site at the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Pond from November 1, 2013–October 31, 2014. The report contains the following information; Facility and system description; Permit required effluent monitoring data and loading rates; Permit required groundwater monitoring data; Status of compliance activities; Noncompliance issues; and Discussion of the facility’s environmental impacts. During the 2014 permit year, approximately 238 million gallons of wastewater were discharged to the Cold Waste Pond. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest near the Cold Waste Pond and decrease rapidly as the distance from the Cold Waste Pond increases. Although concentrations of sulfate and total dissolved solids are elevated near the Cold Waste Pond, both parameters are below the Ground Water Quality Rule Secondary Constituent Standards in the downgradient monitoring wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Global interfertility and heterosis in sugar kelp populations: a next step in sugar kelp breeding

Abstract The potential of seaweed aquaculture is restricted by high labor, production and processing costs, leading to low economic viability. Selective breeding can improve yields and cultivation efficiency, thereby decreasing production costs. Until now, genetic resources as input for Saccharina latissimabreeding trials have been sourced strictly locally, due to concerns regarding outplanting genetically exogenous material in local waters. Here we study, for the first time, worldwide interregional fertility of the seaweedS. latissima,in order to assess the potential of including globalS. latissimagenetic resources for selective breeding with regard to heterosis. We quantified the yield (as an indicative aquacultural performance) and morphological traits of intra- and interregionalS. latissimahybrids originating from a broad range of locations in a common garden experiment. Our results show that the practical application of worldwideS. latissimagenetic resources in breeding programs is feasible based on global interfertility. We found a wide morphological diversity of hybrids and observed significant heterosis in interregional hybrids. The degree of heterosis could not be linked to geographic distance. These findings reveal that worldwide genetic resources can considerably contribute toS. latissimabreeding programs and could offer a major next step in improving yields and quality traits.

Biotechnology & Applied Microbiology↗

Data Locality Enhancement of Dynamic Simulations for Exascale Computing (Final Report)

The development of modern processors exhibits two trends that complicate the optimizations of modern software. The first is the increasing sensitivity of processors' throughput to irregularities in computation. With more processors produced through a massive integration of simple cores, future systems will increasingly favor regular data-level parallel computations, but deviate from the needs of applications with complex patterns. Some evidences are already shown on Graphic Processing Units (GPU): Irregular data accesses (e.g., indirect references A[D[i]]) and conditional branches are limiting many GPU applications' performance at a level an order of magnitude lower than the peak of GPU. The second hardware trend is the growing gap between memory bandwidth and the aggregate speed—that is, the sum of all cores' computing power—of a Chip Multiprocessor (CMP). Despite the capped growth of the peak CPU speed, the aggregate speed of a CMP keeps increasing as more cores get into a single chip. It is expected that by 2018, node concurrency in an exascale system will increase by hundreds of times, whereas, memory bandwidth will expand by only 10 to 20 times. Consequently, data movement and storage is expected to consume more than 70% of the total system power. Bridging this gap is difficult; the complexities of modern CMP memory hierarchy make it even harder: Data cache becomes shared among computing units, and the sharing is often non-uniform—whether two computing units share a cache depends on their proximity and the level of the cache. On the recent IBM Power7 architecture, for instance, four hardware contexts (or SMT threads) in a core share the entire memory hierarchy, all cores in one chip share an on-chip L3 cache, and cores across chips share L3 and main memory through off-chip connections. These two trends complicate the translation of computing power into performance, especially for a program with either intensive data accesses or complex patterns in data accesses or control flow paths. Unfortunately, both attributes present and will persist in a class of important applications. For instance, many scientific simulations deal with a large volume of data. And meanwhile, as most real-world processes are non-uniform and evolving (e.g., the evolution of a galaxy or the process of a drug injection), both the computations and data accesses of these programs tend to be irregular and dynamically changing. Currently, the lack of support to these applications on modern CMP severely limits their performance. On GPU, as our recent study shows and other studies echo, performance enhancement of a factor of integers is possible when memory accesses or control flows are streamlined for a set of GPU applications. On multicore CPU, our studies show that traditional locality enhancement, for being oblivious to the new features of multicore memory hierarchy, may even cause large slowdown to data-intensive dynamic applications. The severity of the issues is expected to worsen as the two hardware trends continue. Some recent studies try to match software with the trends, but in a limited scope or manner. For irregularities on GPU, most studies focus on irregularities analyzable through static analysis (e.g., data accesses in regular loops). Dynamic irregularities are harder to address because the needed analysis and transformations typically have to happen at run time. Some other research resorts to hardware extensions, an actual adoption of which is unclear for the entailed space cost and complexity. For data locality, recent years have seen some exploitations of the new memory hierarchy on multicore for performance, but most of them are on process or thread scheduling, rather than program transformations. Our recent study reveals that program-level transformations may magnify the scheduling benefits by a factor of seven, concluding that program-level transformation should play a central role for data locality enhancement on modern CMP. But research in this direction has been sparse, and most have focused on data layout or cache performance modeling, rather than program transformations to match with the new memory hierarchy features. Overall, it is still an open question how to bridge the gap between dynamic computations and the two prominent properties of modern processors. The goal of this project is to develop a set of techniques and software tools to enhance the matching between memory accesses in dynamic simulations and the prominent features of modern and future CMP, alleviating the memory performance issues for petascale and exascale computing. This report summarizes the discoveries and products produced throughout this project. It includes free launch, a new software approach to overcoming the shortcomings of both methods; coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution; algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Supporting dynamic parallelism is important for GPU to benefit a broad range of applications. There are currently two fundamental ways for programs to exploit dynamic parallelism on GPU: a software-based approach with software-managed worklists, and a hardware-based approach through dynamic subkernel launches. Neither is satisfactory. The former is complicated to program and is often subject to some load imbalance; the latter suffers large runtime overhead. In this work, we propose free launch, a new software approach to overcoming the shortcomings of both methods. It allows programmers to use subkernel launches to express dynamic parallelism. It employs a novel compiler-based code transformation named subkernel launch removal to replace the subkernel launches with the reuse of parent threads. Coupled with an adaptive task assignment mechanism, the transformation reassigns the tasks in the subkernels to the parent threads with a good load balance. The technique requires no hardware extensions, immediately deployable on existing GPUs. It keeps the programming convenience of the subkernel launch-based approach while avoiding its large runtime overhead. Meanwhile, its superior load balancing makes it outperform manual worklist-based techniques by 3X on average. The work was published at the 48th Annual IEEE/ACM International Symposium on Microarchitecture (Micro'2015). A Graphic Processing Unit (GPU) system is typically equipped with many types of memory (e.g., global, constant, texture, shared, cache). Data placement determines what data are placed on which type of memory, essential for GPU memory performance. Prior optimizations of data placement always require a single view of a data object on memory, which limits the optimization effectiveness. In this work, we propose coherence-free multiview, an approach that allows multiple views of a single data object to co-exist on GPU memory during a GPU kernel execution. We demonstrate that under certain conditions, the multiple views can remain incoherent while facilitating enhanced data placement. We present a theorem and some compiler support to ensure the soundness of the usage of coherence-free multiview. We further develop reference-discerning data placement, a new way to enhance data placements on GPU. It enables more flexible data placements by using coherence-free multiview to leverage the slack in coherence requirement of some GPU programs. Experiments on three types of GPU systems show that, with less than 200KB space cost, the new data placement technique can provide a 1.6X average (up to 4.27X) speedup. In addition, we have examined algorithmic optimizations to data analytics problems, especially those that involve lots of distance calculations. Computing distances among data points is an essential part of many important algorithms in data analytics, graph analysis, and other domains. In each of these domains, developers have spent significant manual effort optimizing algorithms, often through novel applications of the triangle equality, in order to minimize the number of distance computations in the algorithms. In this work, we observe that many algorithms across these domains can be generalized as an instance of a generic distance-related abstraction. Based on this abstraction, we derive seven principles for correctly applying the triangular inequality to optimize distance-related algorithms. Guided by the findings, we develop Triangular OPtimizer (TOP), the first software framework that is able to automatically produce optimized algorithms that either matches or outperforms manually designed algorithms for solving distance-related problems. TOP achieves up to 237x speedups and 2.5X on average. The work has been published at the 32nd International Conference on Machine Learning (ICML'15) and the 41st International Conference on Very Large Data Bases (VLDB'15).

42 ENGINEERING↗

An investigation of a novel reusable radiochromic sheet for 2D dose measurement

Purpose Radiochromic film remains a useful and versatile clinical dosimetry tool. Current film options are single use. Here, we introduce a novel prototype two‐dimensional (2D) radiochromic sheet, which optically clears naturally at room temperature after irradiation and can be reused. We evaluate the sheets for potential as a 2D dosimeter and as a radiochromic bolus with capability for dose measurement. Methods A novel derivative of reusable Presage ® was manufactured into thin sheets of 5 mm thickness. The sheets contained 2% cumin‐leucomalachitegreen‐diethylamine (LMG‐DEA) and plasticizer (up to 25% by weight). Irradiation experiments were performed to characterize the response to megavoltage radiation, including dose sensitivity, temporal decay rate, consistency of repeat irradiations, intra and inter‐sheet reproducibility, multi‐modality response (electrons and photons), and temperature sensitivity (22°C to 36°C). The local change in optical‐density (ΔOD), before and after radiation, was obtained with a flat‐bed film scanner and extracting the red channel. Repeat scanning enabled investigation of the temporal decay of ΔOD. Additional studies investigated clinical utility of the sheets through application to IMRT treatment plans (prostate and a TG119 commissioning plan), and a chest wall electron boost treatment. In the latter test, the sheet performed as a radiochromic bolus. Results The radiation induced OD change in the sheets was found to be proportional to dose and to exponentially decay to baseline in ~24 h (R2 = 0.9986). The sheet could be reused and had similar sensitivity (within 1% after the first irradiation) for at least eight irradiations. Importantly, no memory of previous irradiations was observed within measurement uncertainty. The consistency of dose response from photons (6 and 15 MV) and electrons (6–20 MeV) was found to be within calibration uncertainty (~1%). The dose sensitivity of the sheets had a temperature dependence of 0.0012 ΔOD/°C. For the short (1 min) single field IMRT QA verification, good agreement was observed between the Presage sheet and EBT film (gamma pass rate 97% at 3% 3 mm dose‐difference and distance‐to‐agreement tolerance, with a 10% threshold). For the longer (~13 min) TG‐119 9‐field IMRT verification the gamma agreement was lower at 93% pass rate at 5% 3 mm, 10% threshold, when compared with Eclipse. The lower rate is attributed to uncertainty arising from signal decay during irradiation and indicates a current limitation. For the electron cutout treatment, both Presage and EBT agreed well (within 2% RMS difference) but differed from the Eclipse treatment plan (~7% RMS difference) indicating some limitations to the Eclipse modeling in this case. The worst case estimates of uncertainty introduced by the signal decay for deliveries of 2, 5, and 10 min are 0.6%, 1.4%, and 2.8% respectively. Conclusions Reusable Presage sheets show promise for 2D dose measurement and as a radiochromic bolus for in vivo dose measurement. The current prototype is suitable for deliveries of length up to 5 min, where the uncertainty introduced by signal decay is anticipated to be ~1% (worst case 1.4%), or for longer deliveries where there is no temporal modulation (e.g. physical compensators, or open beams). Additionally, spatial resolution is limited by sheet thickness and scanner resolution, resulting in a practical resolution of 0.8 mm.

Collins, Cielle↗

Effectiveness and predictability of in-network storage cache for Scientific Workflows

Large scientific collaborations often have multiple scientists accessing the same set of files while doing different analyses, which create repeated accesses to the large amounts of shared data located far away. These data accesses have long latency due to distance and occupy the limited bandwidth available over the wide-area network. To reduce the wide-area network traffic and the data access latency, regional data storage caches have been installed as a new networking service. To study the effectiveness of such a cache system in scientific applications, we examine the Southern California Petabyte Scale Cache for a high-energy physics experiment. By examining about 3TB of operational logs, we show that this cache removed 67.6% of file requests from the wide-area network and reduced the traffic volume on wide-area network by 12. 3TB (or 35.4%) an average day. The reduction in the traffic volume (35.4%) is less than the reduction in file counts (67.6%) because the larger files are less likely to be reused. Due to this difference in data access patterns, the cache system has implemented a policy to avoid evicting smaller files when processing larger files. We also build a machine learning model to study the predictability of the cache behavior. Tests show that this model is able to accurately predict the cache accesses, cache misses, and network throughput, making the model useful for future studies on resource provisioning and planning.

Sim, Caitlin↗

Photovoltaics on Landfills in Puerto Rico

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Commonwealth of Puerto Rico for a feasibility study of m0treAlables on several brownfield sites. The EPA defines a brownfield as 'a property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant.' All of the brownfields in this study are landfill sites. Citizens of Puerto Rico, city planners, and site managers are interested in redevelopment uses for landfills in Puerto Rico, which are particularly well suited for solar photovoltaic (PV) installation. The purpose of this report is to assess the landfills with the highest potential for possible solar PV installation and estimate cost, performance, and site impacts of three different PV options: crystalline silicon (fixed-tilt), crystalline silicon (single-axis tracking), and thin film (fixed-tilt). Each option represents a standalone system that can be sized to use an entire available site area. In addition, the report outlines financing options that could assist in the implementation of a system. The feasibility of PV systems installed on landfills is highly impacted by the available area for an array, solar resource, operating status, landfill cap status, distance to transmission lines, and distance to major roads. All of the landfills in Puerto Rico were screened according to these criteria in order to determine the sites with the greatest potential. Eight landfills were chosen for site visits based on the screening criteria and location. Because of time constraints and the fact that Puerto Rico is a relatively large island, the eight landfills for this visit were all located in the eastern half of the island. The findings from this report can be applied to landfills in the western half of the island. The economics of a potential PV system on landfills in Puerto Rico depend greatly on the cost of electricity. Currently, PREPA has an average electric rate of $0.119/kWh. Based on past electric rate increases in Puerto Rico and other islands in the Caribbean, this rate could increase to $0.15/kWh or higher in a relatively short amount of time. In the coming years, increasing electrical rates and increased necessity for clean power will continue to improve the feasibility of implementing solar PV systems at these sites.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BraggNN : fast X-ray Bragg peak analysis using deep learning

X-ray diffraction based microscopy techniques such as high-energy diffraction microscopy (HEDM) rely on knowledge of the position of diffraction peaks with high precision. These positions are typically computed by fitting the observed intensities in detector data to a theoretical peak shape such as pseudo-Voigt. As experiments become more complex and detector technologies evolve, the computational cost of such peak-shape fitting becomes the biggest hurdle to the rapid analysis required for real-time feedback in experiments. To this end, we propose BraggNN, a deep-learning based method that can determine peak positions much more rapidly than conventional pseudo-Voigt peak fitting. When applied to a test dataset, peak center-of-mass positions obtained from BraggNN deviate less than 0.29 and 0.57 pixels for 75 and 95% of the peaks, respectively, from positions obtained using conventional pseudo-Voigt fitting (Euclidean distance). When applied to a real experimental dataset and using grain positions from near-field HEDM reconstruction as ground-truth, grain positions using BraggNN result in 15% smaller errors compared with those calculated using pseudo-Voigt. Recent advances in deep-learning method implementations and special-purpose model inference accelerators allow BraggNN to deliver enormous performance improvements relative to the conventional method, running, for example, more than 200 times faster on a consumer-class GPU card with out-of-the-box software.

36 MATERIALS SCIENCE↗

Decontamination Experiments and Simulations Supporting Recovery After Widespread Contamination - 18685

Clean-up after an uncontrolled nuclear material release differs from common decontamination practices in the nuclear industry and military combat scenarios. Uncontrolled releases, particularly acts of terror, require specific protective actions guides (PAGs) to optimize short and long-term repercussions. Ideally, non-destructive decontamination methods would be employed. To help fulfill this need, the IWATERS (Integrated Wash Aid Treatment Emergency Reuse System) was proposed in 2014 for remediation outside the immediate blast area. 'Wash-Aid' is hosed onto affected areas, and the used wash solution is collected and recycled through sand/clay beds. To help characterize the IWATERS technology, the below was completed: - Decontamination experiments with a pressurized wash solution using Cs-137, Sr- 85, and Eu-152 contaminants on porous urban materials. - Sensitivity analyses on recycling bed variables using GoldSim{sup TM} CT. - A proposed framework that expands the recycling bed model to include probabilistic simulation of immediate recovery efforts. Removal efficacy of tap water and 0.5 M KCl were compared for Cs, Sr, and Eu across asphalt, brick, and concrete. The 0.5 M KCl solution significantly outperformed tap water in every case except for Eu on concrete and Cs on brick. Trends in the high-pressure decontamination with salt additive compared to low pressure decontamination show evidence of physical and chemical removal. Variations in cleaning rate yielded no significant trend. Pressure changes (by adjusting nozzle-to-coupon distance) were only significant for the highest pressure. Hypothetical Contamination Scenario: To tie the decontamination experiments and recycling bed model together, a small contamination scenario was created. Imagine the sides of a small concrete building uniformly contaminated with Cs-137. Power washing the building with 0.5 M KCl solution would result in 857 L of contaminated solution generated in 185 minutes. Two sand clay beds were designed to clean the used solution. With a sand mass fraction of 0.9, a 10 ft{sup 2} bed 4 ft tall could recycle the solution in 1.05 hrs. Changing the sand mass fraction to 0.5 yielded a 2.5 ft{sup 2} bed 4 ft tall (∼55-gallon drum) that recycled the solution in 7.43 hrs. This exercise showed how the sand/clay bed design can easily change to match the primary remediation goals. The second sand/clay bed would reduce the waste generation while the first bed reduces the remediation time. Conclusions: Variations on speed and nozzle distance (pressure) yielded insignificant differences in efficacy except for the closest distance. High-pressure washing showed increased decontamination efficacy with KCl additive in the majority of cases. Except for bed composition, key recycling bed parameters can be varied on-the-fly. This allows for optimization of, for example, time and waste generation. The hypothetical contamination scenario showed pairing decontamination experiment results with modeling tools can lead to increased preparedness for a large-scale contamination event. With collaboration and time, an expanded recovery/remediation model could aid in development of effective protective action guides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reuse of Produced Water from CO 2 Enhanced Oil Recovery, Coal-Bed Methane, and Mine Pool Water by Coal-Based Power Plants

Power generation in the Illinois Basin is expected to increase by as much as 30% by the year 2030, and this would increase the cooling water consumption in the region by approximately 40%. This project investigated the potential use of produced water from CO 2 enhanced oil recovery (CO 2 -EOR) operations; coal-bed methane (CBM) recovery; and active and abandoned underground coal mines for power plant cooling in the Illinois Basin. Specific objectives of this project were: (1) to characterize the quantity, quality, and geographic distribution of produced water in the Illinois Basin; (2) to evaluate treatment options so that produced water may be used beneficially at power plants; and (3) to perform a techno-economic analysis of the treatment and transportation of produced water to thermoelectric power plants in the Illinois Basin. Current produced water availability within the basin is not large, but potential flow rates up to 257 million liters per day (68 million gallons per day (MGD)) are possible if CO 2 -enhanced oil recovery and coal bed methane recovery are implemented on a large scale. Produced water samples taken during the project tend to have dissolved solids concentrations between 10 and 100 g/L, and water from coal beds tends to have lower TDS values than water from oil fields. Current pretreatment and desalination technologies including filtration, adsorption, reverse osmosis (RO), and distillation can be used to treat produced water to a high quality level, with estimated costs ranging from $2.6 to $10.5 per cubic meter ($10 to $40 per 1000 gallons). Because of the distances between produced water sources and power plants, transportation costs tend to be greater than treatment costs. An optimization algorithm was developed to determine the lowest cost pipe network connecting sources and sinks. Total water costs increased with flow rate up to 26 million liters per day (7 MGD), and the range was from $4 to $16 per cubic meter ($15 to $60 per 1000 gallons), with treatment costs accounting for 13-23% of the overall cost. Results from this project suggest that produced water is a potential large source of cooling water, but treatment and transportation costs for this water are large.

20 FOSSIL-FUELED POWER PLANTS↗

Infrastructure Ecology for Sustainable and Resilient Urban Infrastructure Design

The population growth coupled with increasing urbanization is predicted to exert a huge demand on the growth and retrofit of urban infrastructure, particularly in water and energy systems. The U.S. population is estimated to grow by 23% (UN, 2009) between 2005 and 2030. The corresponding increases in energy and water demand were predicted as 14% (EIA, 2009) and 20% (Elcock, 2008), respectively. The water-energy nexus needs to be better understood to satisfy the increased demand in a sustainable manner without conflicting with environmental and economic constraints. Overall, 4% of U.S. power generation is used for water distribution (80%) and treatment (20%). 3% of U.S. water consumption (100 billion gallons per day, or 100 BGD) and 40% of U.S. water withdrawal (340 BGD) are for thermoelectric power generation (Goldstein and Smith, 2002). The water demand for energy production is predicted to increase most significantly among the water consumption sectors by 2030. On the other hand, due to the dearth of conventional water sources, energy intensive technologies are increasingly in use to treat seawater and brackish groundwater for water supply. Thus comprehending the interrelation and interdependency between water and energy system is imperative to evaluate sustainable water and energy supply alternatives for cities. In addition to the water-energy nexus, decentralized or distributed concept is also beneficial for designing sustainable water and energy infrastructure as these alternatives require lesser distribution lines and space in a compact urban area. Especially, the distributed energy infrastructure is more suited to interconnect various large and small scale renewable energy producers which can be expected to mitigate greenhouse gas (GHG) emissions. In the case of decentralized water infrastructure, on-site wastewater treatment facility can provide multiple benefits. Firstly, it reduces the potable water demand by reusing the treated water for non-potable uses and secondly, it also reduces the wastewater load to central facility. In addition, lesser dependency on the distribution network contributes to increased reliability and resiliency of the infrastructure. The goal of this research is to develop a framework which seeks an optimal combination of decentralized water and energy alternatives and centralized infrastructures based on physical and socio-economic environments of a region. Centralized and decentralized options related to water, wastewater and stormwater and distributed energy alternatives including photovoltaic (PV) generators, fuel cells and microturbines are investigated. In the context of the water-energy nexus, water recovery from energy alternatives and energy recovery from water alternatives are reflected. Alternatives recapturing nutrients from wastewater are also considered to conserve depleting resources. The alternatives are evaluated in terms of their life-cycle environmental impact and economic performance using a hybrid life cycle assessment (LCA) tool and cost benefit analysis, respectively. Meeting the increasing demand of a test bed, an optimal combination of the alternatives is designed to minimize environmental and economic impacts including CO2 emissions, human health risk, natural resource use, and construction and operation cost. The framework determines the optimal combination depending on urban density, transmission or conveyance distance or network, geology, climate, etc. Therefore, it will be also able to evaluate infrastructure resiliency against physical and socio-economic challenges such as population growth, severe weather, energy and water shortage, economic crisis, and so on.

30 DIRECT ENERGY CONVERSION↗

Life Cycle Assessment and Life Cycle Cost Analysis of Repurposing Decommissioned Wind Turbine Blades as High-Voltage Transmission Poles

Wind energy is widely deployed and will likely grow in service of reducing the world’s dependency on fossil fuels. The first generation of wind turbines are now coming to the end of their service lives, and there are limited options for the reuse or recycling of the composite materials they are made of. Current literature has verified that there is no existing recycling pathway (i.e., mechanical, chemical, thermal methods of recovery, etc.) for end-of-life materials in wind blades that can meet cost parity with landfilling in the US. However, to the authors’ knowledge there is no study to date that uncovers the cost structures associated with repurposing wind turbine blades in the US. Repurposing could offer a cost-competitive advantage through displacement of higher-value products, rather than materials or chemical constituents alone. This study implements life cycle assessment (LCA) and life cycle cost analysis (LCC) to assess the environmental and financial implications at each stage of repurposing wind turbine blades as the primary load-carrying elements for high-voltage transmission line structures in the United States. This case study contribution to knowledge is based on the successful management of construction waste by analyzing an application for repurposing construction demolition waste. Specifically, this study presents an environmental and financial analysis of repurposing wind turbine blades as transmission line poles. Under this case study, our results show that BladePoles have lower greenhouse gas emissions than steel poles, and we anticipate BladePoles will be less costly than steel poles. Overall emissions are most sensitive to combustion emissions, driven primarily by transportation distance and hours of required crane operations during the installation process. Compared to other evaluated recycling methods, repurposing wind blades as BladePoles has the least overall global warming potential.

42 ENGINEERING↗