Search NASA⌕ Search

SEARCH · Search NASA

Results for “Room Return”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ion-Conducting Thermoresponsive Films Based on Polymer-Grafted Cellulose Nanocrystals

Mechanically robust, thermo-responsive, ion-conducting nanocomposite films are prepared from poly(2-phenylethyl methacrylate) grafted cellulose nanocrystals (MxG-CNC-g-PPMA). One-component nanocomposite films of the polymer grafted nanoparticle (PGN) MxG-CNC-g-PPMA are imbibed with 30 wt% imidazolium-based ionic liquid, to produce flexible ion-conducting films. These films with 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[H]) not only displays remarkable improvements in toughness (>25 times) and tensile strength (>70 times) relative to the corresponding nanocomposites consisting of the ionic liquid imbibed in the two component CNC/PPMA nanocomposite, but also shows higher ionic conductivity than the corresponding neat PPMA with the same wt.% of ionic liquid. Notably, the one-component film containing 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (MxG-CNC-g-PPMA/[E]) exhibits temperature responsive ionic conduction. The ionic conductivity decreases at around 60°C as a consequence of the lower critical solution temperature (LCST) phase transition of the grafted polymer in the ionic liquid, which leads to phase separation. Moreover, holding the MxG-CNC-g-PPMA/[E] film at room temperature for 24 hours returns the film to its original homogenous state. These materials exhibit properties relevant to thermal cutoff safety devices (e.g., thermal fuse) where a reduction in conductivity above a critical temperature is needed.

36 MATERIALS SCIENCE↗

Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TATB ratchet growth and hydrostatically-confined PBX 9502

The explosive TATB (1,3,5-triamino-2,4,6-trinitirobenzene) is formulated with various polymeric binders to create plastic-bonded explosives like PBX 9502 (95 wt% TATB and 5 wt% Kel-F binder). TATB crystals are graphitic and plate-like in nature and single crystals exhibit anisotropic thermal expansion where the direction normal to the platelet surface grows 10-20 times more than the in-plane platelet direction. Compactions of TATB, with and without binder, exhibit irreversible volume expansion, also known as ratchet growth, when thermal cycled to hot or cold temperatures. Specifically, when TATB-based compactions return to ambient after a temperature excursion away from room temperature, the volume of the specimen is slightly larger. Repeated thermal cycles can reduce the density by 1 to 2%. Axial confinement on a cylindrical specimen has previously been shown by us to suppress growth in the confining direction but then increase growth in the unconfined directions (likely due to creep effects). In the work presented here, PBX 9502 specimens were placed in cup assemblies where they were embedded in Sylgard (an incompressible silicon resin) to provide hydrostatic confinement when the assemblies were placed under different axial loads. The loaded cup assemblies were thermally cycled 10 times to hot and cold temperatures. Finally, results show that increasing the hydrostatic confining pressure causes a decrease in the PBX 9502 volume expansion that occurs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measured influence of overhead HVAC on exposure to airborne contaminants from simulated speaking in a meeting and a classroom

Tracer gas experiments were conducted in a 158 m 3 room with overhead supply diffusers to study dispersion of contaminants from simulated speaking in physically distanced meeting and classroom configurations. The room was contained within a 237 m 3 cell with open plenum return to the HVAC system. Heated manikins at desks and a researcher operating the tracer release apparatus presented 8-9 thermal plumes. Experiments were conducted under conditions of no forced air and neutral, cooled, or heated air supplied at 980-1100 cmh, and with/out 20% outdoor air. CO 2 was released at the head of one manikin in each experiment to simulate small (< 5 µm diameter) respiratory aerosols. The metric of exposure relative to perfectly mixed (ERM) is introduced to quantify impacts, based on measurements at manikin heads and at three heights in the center and corners of the room. Chilled or neutral supply air provided good mixing with ERMs close to one. Thermal stratification during heating produced higher ERMs at most manikins: 25% were ≥ 2.5 and the highest were > 5× perfectly mixed conditions. Operation of two within-zone air cleaners together moving ≥400 cmh vertically in the room provided enough mixing to mitigate elevated exposure variations.

54 ENVIRONMENTAL SCIENCES↗

DEVELOPMENT OF INEXPENSIVE HIGH TEMPERATURE NITI-BASED SHAPE MEMORY ALLOYS FOR POWDER BED ADDITIVE MANUFACTURING

NiTi and NiTi-based Shape Memory Alloys (SMA) exhibit a reversible solid-state phase transformation from martensite to austenite driven by thermal energy. High temperature (Mf>100°C) SMAs are martensite at room temperature and can be fabricated into solid-state actuators that return to a pre-programmed shape against a designed load after heating to transformation threshold. Reactive as-fabricated additively manufactured parts (4-D printing) is the current state of the art in manufacturing of SMAs but requires compositions compliant to rapid solidification. Existing actuator designs are developed from commercially available, highly investigated material compositions. However, existing high temperature high performance (high actuation strain, low thermal hysteresis) shape memory alloys contain significant (>10% at.) portions of high-cost Platinum Group Metals (PGMs). It is of significant scientific interest to investigate material compositions that are peer performing or superior to PGMs whose constituent elements represent a significant cost savings. Shape memory alloy properties vary significantly with small (0.1% at.) compositional changes making robust investigative sample sets very large. Computational material design can be deployed to shrink the compositional space of possible alloy combinations and reduce the experimental load in material discovery. Investigating shape memory effect (SME) and validating process additive process parameters for a single novel composition is cost intensive in both time and consumed materials. Additionally, sub-optimal processing, oxygen, or solidification rate sensitivity could render additively manufacturing specimens without micro, macro cracks, or significant chemical variance impossible. Unfortunately, such failure susceptibility cannot be simulated. Therefore, a research pathway to validate novel shape memory alloy compositions for powder bed fusion additive manufacturing without the need for powdered feedstock is also proposed. This research investigates novel high temperature shape memory alloys for actuators without platinum group alloying elements to discover one that could be commercially viable as an additive manufacturing feedstock.

Sundermann, Tayler↗

Tunable Nanoscale Evolution and Topological Phase Transitions of a Polar Vortex Supercrystal

Here, understanding the phase transitions and domain evolutions of mesoscale topological structures in ferroic materials is critical to realizing their potential applications in next-generation high-performance storage devices. Here, the behaviors of a mesoscale supercrystal are studied with 3D nanoscale periodicity and rotational topology phases in a PbTiO 3 /SrTiO 3 (PTO/STO) superlattice under thermal and electrical stimuli using a combination of phase-field simulations and X-ray diffraction experiments. A phase diagram of temperature versus polar state is constructed, showing the formation of the supercrystal from a mixed vortex and α-twin state and a temperature-dependent erasing process of a supercrystal returning to a classical α-twin structure. Under an in-plane electric field bias at room temperature, the vortex topology of the supercrystal irreversibly transforms to a new type of stripe-like supercrystal. Under an out-of-plane electric field, the vortices inside the supercrystal undergo a topological phase transition to polar skyrmions. These results demonstrate the potential for the on-demand manipulation of polar topology and transformations in supercrystals using electric fields. The findings provide a theoretical understanding that may be utilized to guide the design and control of mesoscale polar structures and to explore novel polar structures in other systems and their topological nature.

P=phase-field simulations↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Performance of PIP-II high-beta 650 cryomodule after transatlantic shipping

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

43 PARTICLE ACCELERATORS↗

PIP-II High Beta 650 Prototype Cryomodule Assembly Experience and Related Design Optimization

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

Ozelis, J.↗

Radiation Mapping UAV [Poster]

The NuMI (Neutrinos at the Main Injector) target system delivers a high-energy flux of muon-neutrinos towards a detector more than 800 km away with the goal of better understanding the origin of the universe and its evolution. The target system becomes radioactive because it is irradiated by a sub-Mega-Watt power proton beam. Radiological hazard is one of critical issues for a radiological worker which limits the iractivities near the target system; however, they often need to quantify the radiation level of the target system manually. Thus, the objective of this project is to reduce their exposure to radiation while improving the accuracy of the measurements. A quadcopter UAV fitted with a radiation dosimeter is ideal to traverse the irradiated environment as it can be deployed in any space and requires minimal hardware integration to the test room. Due to the lack of indoor GPS signal, this UAV utilizes a series of ultrasonic beacons that release several varied-frequency pulses simultaneously in order to localize the drone. The flight controller returns a 3D coordinate tied to the radiation data to understand precisely where radiation spikes are being emitted from the horn. The flight controller stores log data that can be processed into an easily interpretable map of radiation intensities. The radiation map serves as one of the primary references for planning the transportation of the NuMI horn.

43 PARTICLE ACCELERATORS↗

Vanderbilt Alumni Hall

This dataset includes processed and raw data from the Vanderbilt Alumni Hall Building (VAH) located on the University of Vanderbilt Campus in Nashville, TN. VAH is a mixed use commercial building (LEED Gold Certified) that consists of classrooms, meeting rooms, office rooms, conference rooms, an exercise room, and others. This dataset spans one year of time-series data from 2019 and includes measurements corresponding to whole building electrical power, thermal power, zone level thermal power, set-point, indoor temperature, humidity, water and air side supply and return temperatures and flow rates as CSV files. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

In situ characterization of residual stress evolution during heat treatment of SiC/SiC ceramic matrix composites using high-energy X-ray diffraction

Volumetric strains were measured in silicon carbide/silicon carbide melt-infiltrated ceramic matrix composites (CMCs) at ambient and high temperatures using high-energy synchrotron X-ray diffraction (XRD). Both silicon and silicon carbide constituents were interrogated utilizing a broad spectrum of diffracting planes that would be largely inaccessible to common laboratory XRD equipment. Residual room-temperature principal strains in the melt-infiltrated silicon phase were found to be approximately 1100 mu epsilon in compression, corresponding to stresses of approximately 300 MPa using simplifying constitutive assumptions. Residual room-temperature principal strains in silicon carbide particles found throughout the matrix were approximately 500 mu epsilon in tension, corresponding to approximately 300 MPa. Residual strains were found to decrease considerably as temperatures increased from ambient temperature to 1250 degrees C. Additionally, residual strains returned to approximately preheat treatment values after cool-down to ambient temperature. Strain measurements in the silicon phase were found to be significantly affected by dissolved boron dopant levels causing contraction of the silicon lattice. This contraction must be accounted for in high-temperature experiments for accurate calculation of stresses in the silicon phase.

36 MATERIALS SCIENCE↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial separation of triplet excitons drives endothermic singlet fission

Molecules that undergo singlet fission, converting singlet excitons into pairs of triplet excitons, have potential as photovoltaic materials. The possible advantages of endothermic singlet fission (enhanced use of photon energy and larger triplet energies for coupling with common absorbers) motivated us to assess the role of exciton delocalization in the activation of this process. Here we report the synthesis of a series of linear perylene oligomers that undergo endothermic singlet fission and have endothermicities in the range 5-10 kBT at room temperature in solution. We study these compounds using transient spectroscopy and modelling to unravel the singlet and triplet dynamics. We show that the minimal number of coupled chromophores needed to undergo endothermic singlet fission is three, which provides sufficient statistical space for triplet excitons to separate and avoid annihilation - and a subsequent fast return to the singlet state. Our data additionally suggest that torsional motion of chromophores about the molecular axis following triplet-pair separation contributes to the increase in entropy, thus lengthening the triplet lifetime in longer oligomers.

14 SOLAR ENERGY↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-resolution absorption spectroscopy of room-temperature and jet-cooled ammonia between 59,000 and 93,000 cm -1

Here, we present new high-resolution photoabsorption spectra of ammonia spanning the region between 59,000 cm -1 and 93,000 cm -1 that were recorded by using the Fourier Transform Spectrometer at the Synchrotron SOLEIL. This region extends from just above the Franck-Condon envelope for the $\tilde{A}$ 1 $A$ 2 " ← $\tilde{X}$ 1 $A$ 1 ' transition to well above the NH 3 + $\tilde{X}$ + 2 $A$ 2 " ionization threshold. The spectra were recorded at a measured resolution of 0.23 cm -1 in both a room-temperature cell (293 K) and in a slit-jet supersonic expansion (~70 K). The absolute photoabsorption cross section with an uncertainty of ±5% is also reported for the room-temperature spectrum. The present resolution is a factor of 10 – 100 times higher than in other recently reported broad band spectra of ammonia, and many of the observed bands show partially resolved rotational structure. We have attempted to assign this structure for a number of these bands. The oscillator strengths extracted from the data are in good agreement with previous measurements but, in the case of structured bands, the present higher resolution measurements return higher peak absorption cross sections, that increase further when the sample is cooled. The present higher resolution spectra suggest that a number of previous vibronic band assignments that were based on quantum defect considerations may require some revision. Finally, we discuss the substantial differences between the photoabsorption and photoionization data just above the first ionization threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗