Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: {phi}{sub scd} = 1.10{sup 6} n/cm{sup 2}/s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-site evaluation of the LN34 pan-lyssavirus real-time RT-PCR assay for post-mortem rabies diagnostics

Rabies is a fatal zoonotic disease that requires fast, accurate diagnosis to prevent disease in an exposed individual. The current gold standard for post-mortem diagnosis of human and animal rabies is the direct fluorescent antibody (DFA) test. While the DFA test has proven sensitive and reliable, it requires high quality antibody conjugates, a skilled technician, a fluorescence microscope and diagnostic specimen of sufficient quality. The LN34 pan-lyssavirus real-time RT-PCR assay represents a strong candidate for rabies post-mortem diagnostics due to its ability to detect RNA across the diverse Lyssavirus genus, its high sensitivity, its potential for use with deteriorated tissues, and its simple, easy to implement design. Here, we present data from a multi-site evaluation of the LN34 assay in 14 laboratories. A total of 2,978 samples (1,049 DFA positive) from Africa, the Americas, Asia, Europe, and the Middle East were tested. The LN34 assay exhibited low variability in repeatability and reproducibility studies and was capable of detecting viral RNA in fresh, frozen, archived, deteriorated and formalin-fixed brain tissue. The LN34 assay displayed high diagnostic specificity (99.68%) and sensitivity (99.90%) when compared to the DFA test, and no DFA positive samples were negative by the LN34 assay. The LN34 assay produced definitive findings for 80 samples that were inconclusive or untestable by DFA; 29 were positive. Five samples were inconclusive by the LN34 assay, and only one sample was inconclusive by both tests. Furthermore, use of the LN34 assay led to the identification of one false negative and 11 false positive DFA results. Together, these results demonstrate the reliability and robustness of the LN34 assay and support a role for the LN34 assay in improving rabies diagnostics and surveillance.

60 APPLIED LIFE SCIENCES↗

Collimated phase measuring deflectometry

Phase measuring deflectometry has been applied for free-form specular surface metrology, but its measured slope results are sensitive to the depth of sample positioning, which is also called the height-slope ambiguity. The objective of this work is to tackle this height-slope ambiguity problem. The main idea is to introduce collimated camera rays using a telecentric imaging lens and collimated structured-light illumination with a Fourier lens. This setup makes the fringe phases become only sensitive to the surface slopes and insensitive to the depth of the sample positioning. In this way, the slope calculation is theoretically independent of the sample depth. We call this new deflectometry technique Collimated Phase Measuring Deflectometry (CPMD). With our developed CPMD experimental setup, the measurement is insensitive to the depth of sample positioning, e.g., the measured height dispersion is less than 30 nm RMS within a 10 mm depth range when measuring a 50-mm-diameter spherical mirror with a 200 mm radius of curvature. In conclusion, the merits and limitations of the proposed CPMD technique are discussed, revealing its prospects in practical metrology applications and potential future investigations.

36 MATERIALS SCIENCE↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

High resolution 3D imaging of synchrotron generated microbeams

Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

60 APPLIED LIFE SCIENCES↗

Genomic-based biosurveillance for avian influenza: whole genome sequencing from wild mallards sampled during autumn migration in 2022–2023 reveals a high co-infection rate on migration stopover site in Georgia

The Caucasus region, including Georgia, is an important intersection for migratory waterbirds, offering potential for avian influenza virus (AIV) transmission between populations from different geographic areas. In 2022 and 2023, wild ducks were sampled during autumn migration events in Georgia to study the genetic relationships and molecular characteristics of influenza strains. Sequencing and phylogenetic analysis were used to compare the sampled strains to reference sequences from Africa, Asia, and Europe, allowing assessment of genetic relationships and virus transmission between migratory birds. Protein language modeling identified potential co-infections. Of 225 duck samples, 128 tested positive for the influenza M gene. 55 influenza-positive samples underwent whole-genome sequencing, revealing significant diversity. Analysis of the hemagglutinin (HA) segment showed notable differences among subtypes. Most samples were H6N1 and H6N6, but co-infections with combinations like H6H3, N8N1, N6H9, N2N6, and H9H6/N1N2 were also identified. These findings demonstrate the high variability of influenza viruses in migratory waterbirds in Georgia, including a notable rate of co-infections. Some samples exhibited uncommon genetic characteristics compared to other strains from the same year, suggesting Georgia’s role as a mixing vessel for influenza viruses. This facilitates reassortment during co-infections and contributes to the genetic diversity observed across flyways.

59 BASIC BIOLOGICAL SCIENCES↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of SARS-CoV-2 testing and genomic sequencing into influenza sentinel surveillance in Uganda, January to December 2022

The Uganda Virus Research Institute, National Influenza Center laboratory integrated SARS-CoV-2 polymerase chain reaction testing and genomic sequencing into the influenza surveillance program that was established in 2007. A total of 7,698 nasopharyngeal/oropharyngeal (NP/OP) swab samples were collected and analyzed from ILI/SARI sentinel sites across the country from January to December 2022. All samples were tested for influenza and SARS-CoV-2. Of these, 252 (3.3%), 162 (2.1%), and 589 (7.7%) were positive for influenza A, influenza B, and SARS-CoV-2, respectively. Out of 414 influenza-positive samples, 122 (29.5%) were AH1pdm09, 130 (31.4%) were AH3, and 162 (39.1%) were B-Victoria. All SARS-CoV-2 sequenced samples were of the Omicron variant, with subvariants of concern known to evade the immune system being detected, such as BQ.1 and XBB.2. Other SARS-CoV-2 positive samples collected from other health centers in the community outside the surveillance sites were included into SARS-CoV-2 genomic sequencing with similar patterns with respect to variants. In all, the ILI/SARI surveillance system has shown to be an efficient, cost-effective, and sustainable program, providing a ready platform to monitor the circulation of SARS-CoV-2 in communities at the national level while remaining vigilant for the persistent threat of influenza. The integration of SARS-CoV-2 detection and genomic surveillance into the influenza surveillance program will strengthen the laboratory response capacity, as well as facilitate the timely release of SARS-CoV-2 genomic information to be used to complement the multiple response strategies for COVID-19 pandemic mitigation.

59 BASIC BIOLOGICAL SCIENCES↗

Etched Silicon Planar CRL Optics for the High-Energy X-ray Diffraction Beamlines 11-ID-B and 11-ID-C at the APS

We report the focusing of high-energy X-rays is most commonly achieved by commercially available compound refractive lenses (CRL), which are added together in larger structures. There is a need for high-energy X-ray beamlines to enable focusing in only one dimension down to a few micrometers to study layered materials and thin films. High-energy X-rays above 50 keV require often 100 lenses or more, therefore it is more efficient to etch the complete arrays of lenses into a monolithic substrate like a silicon wafer. Custom lens arrays were fabricated for the high-energy x-ray beamlines 11-ID-B, and 11-ID-C at the Argonne National Laboratory. The fabrication required tuning parameters of the Bosch process to optimize the etching of deep vertical sidewalls at a reasonable speed without overheating. The beamline 11-ID-B is equipped with lens arrays of 85-110 lenses for 59 keV and 190-250 lenses for 87 keV photon energy, focusing the beam vertically below 5.0 µm at the sample positions between 1600 mm to 2100 mm. 11-ID-C has received arrays of 435 lenses that focus 106 keV X-rays to a vertical height of 2.0 µm at the sample position. In both cases, the flux density gain in the focal spot is larger than a factor of 20, relative to using slits to cut the beam size. The lens setup is permanently installed and can be moved in and out of the beam during the experiment without further alignment. The lenses have enabled operando diffraction studies on interfaces in batteries and the development of pair distribution function (PDF) analysis using grazing incidence geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical design of the short pulse x-ray imaging and microscopy time-angle correlated diffraction beamline at the Advanced Photon Source

The short pulse x-ray imaging and microscopy beamline is one of the two x-ray beamlines that will take full advantage of the short pulse x-ray source in the Advanced Photon Source (APS) upgrade. A horizontally diffracting double crystal monochromator which includes a sagittally focusing second crystal will collect most of the photons generated when the chirped electron beam traverses the undulator. A Kirkpatrick-Baez mirror system after the monochromator will deliver to the sample a beam which has an approximately linear correlation between time and vertical beam angle. The correlation at the sample position has a slope of 0.052 ps/{mu}rad extending over an angular range of 800 {mu}rad for a cavity deflection voltage of 2 MV. The expected time resolution of the whole system is 2.6 ps. The total flux expected at the sample position at 10 keV with a 0.9 eV energy resolution is 5.7 Multiplication-Sign 10{sup 12} photons/s at a spot having horizontal and vertical full width at half maximum of 33 {mu}m horizontal by 14 {mu}m vertical. This new beamline will enable novel time-dispersed diffraction experiments on small samples using the full repetition rate of the APS.

43 PARTICLE ACCELERATORS↗

Inverse geometry for grating-based x-ray phase-contrast imaging

Phase-contrast imaging using conventional polychromatic x-ray sources and grating interferometers has been developed and demonstrated for x-ray energies up to 60 keV. Here, we conduct an analysis of possible grating configurations for this technique and present further geometrical arrangements not considered so far. An inverse interferometer geometry is investigated that offers significant advantages for grating fabrication and for the application of the method in computed tomography (CT) scanners. We derive and measure the interferometer's angular sensitivity for both the inverse and the conventional configuration as a function of the sample position. Thereby, we show that both arrangements are equally sensitive and that the highest sensitivity is obtained, when the investigated object is close to the interferometer's phase grating. We also discuss the question whether the sample should be placed in front of or behind the phase grating. For CT applications, we propose an inverse geometry with the sample position behind the phase grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated nonlinear optical imaging microscope for on-axis crystal detection and centering at a synchrotron beamline

Nonlinear optical (NLO) instrumentation has been integrated with synchrotron X-ray diffraction (XRD) for combined single-platform analysis, initially targeting applications for automated crystal centering. Second-harmonic-generation microscopy and two-photon-excited ultraviolet fluorescence microscopy were evaluated for crystal detection and assessed by X-ray raster scanning. Two optical designs were constructed and characterized; one positioned downstream of the sample and one integrated into the upstream optical path of the diffractometer. Both instruments enabled protein crystal identification with integration times between 80 and 150 µs per pixel, representing a ~10 3 –10 4 -fold reduction in the per-pixel exposure time relative to X-ray raster scanning. Quantitative centering and analysis of phenylalanine hydroxylase from Chromobacterium violaceum cPAH, Trichinella spiralis deubiquitinating enzyme TsUCH37, human κ-opioid receptor complex kOR-T4L produced in lipidic cubic phase (LCP), intimin prepared in LCP, and α-cellulose samples were performed by collecting multiple NLO images. The crystalline samples were characterized by single-crystal diffraction patterns, while α-cellulose was characterized by fiber diffraction. Good agreement was observed between the sample positions identified by NLO and XRD raster measurements for all samples studied.

bio-inspired↗

A Bayesian Measurment Error Model for Misaligned Radiographic Data

An understanding of the inherent variability in micro-computed tomography (micro-CT) data is essential to tasks such as statistical process control and the validation of radiographic simulation tools. The data present unique challenges to variability analysis due to the relatively low resolution of radiographs, and also due to minor variations from run to run which can result in misalignment or magnification changes between repeated measurements of a sample. Positioning changes artificially inflate the variability of the data in ways that mask true physical phenomena. We present a novel Bayesian nonparametric regression model that incorporates both additive and multiplicative measurement error in addition to heteroscedasticity to address this problem. We also use this model to assess the effects of sample thickness and sample position on measurement variability for an aluminum specimen. Supplementary materials for this article are available online.

97 MATHEMATICS AND COMPUTING↗

Understanding Anomalous Gas-Phase Peak Shifts in Dip-and-Pull Ambient Pressure XPS Experiments

Dip-and-pull ambient pressure X-ray photoelectron spectroscopy (AP-XPS) holds promise to uncover elementary processes of (photo)electrochemistry. We show, however, that the sample for such experiments should preferably be nonporous and the potential on the surface homogeneous. We carried out dip-and-pull AP-XPS experiments on a hematite thin film sample under the photoelectrochemical oxygen evolution reaction (OER) and find unexpected O 1s core level shifts. Upon electrochemical biasing under simulated solar light illumination, the gas-phase water peak shifted more than the electrolyte peak. To uncover the origin of the unexpected larger shift of the gas-phase peak, we performed electrostatic simulations using COMSOL, to map the potential field in the relevant volume between the sample and the first aperture of the XPS spectrometer. A number of geometric models were considered. We find that when the potential on the sample surface is inhomogeneous, e.g., with ionically isolated electrolyte patches, the gas-phase peak of the spectrum can shift more than the peak due to the electrolyte film. This suggests that at the measured sample position, the local potential was not as set by the potentiostat. Despite this, we find reversible consumption and replenishment of hydroxide in the spectra, which, due to OH– being the reactant of the OER in alkaline electrolyte, makes sense chemically. We propose that this is linked to OH– diffusion across the measured sample position, driven by the potential dependent consumption and replenishment of OH– at the nearby well-connected surface regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How to design a focusing guide: The large moderator case1

As continuously shaped super-mirrors are becoming available, the conceptual design of focusing guides should explore a wider range of possibilities to accomplish an efficient neutron beam extraction. Starting from a desired phase-space volume at the sample position and using an upstream ray-tracing approach, the acceptance diagram of any focusing guide can be calculated at the moderator position. To ensure high brilliance transfer and homogeneous coverage, the acceptance diagram should be fully included in the neutron source emission phase-space volume. Following this idea, the guide system can be scaled into dimensionless geometric figures that convey performance limits for a desired cross-section reduction. Moreover, if we impose a monotonic increase of the reflection angle with divergence angle at the sample position, the shape of the mirror is analytically determined. This approach was applied in the design of a focusing guide for SNAP instrument at SNS, at ORNL, USA. The results of McStas simulations are presented with different options included. Our approach facilitates finding an optimal solution for connecting multiple guide pieces to avoid excessive losses and ensure a homogeneous phase space coverage.

Frost, Matthew↗

Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Additionally, comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.

47 OTHER INSTRUMENTATION↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend) This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 mu m spot of ~;;5x109 photons/ s (0.1percent bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored bytwo pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 um are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (~;;0.2 mu m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10-5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (~;;150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

47 OTHER INSTRUMENTATION↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗