Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Siting Samplers to Minimize Expected Time to Detection

We present a probabilistic approach to designing an indoor sampler network for detecting an accidental or intentional chemical or biological release, and demonstrate it for a real building. In an earlier paper, Sohn and Lorenzetti(1) developed a proof of concept algorithm that assumed samplers could return measurements only slowly (on the order of hours). This led to optimal detect to treat architectures, which maximize the probability of detecting a release. This paper develops a more general approach, and applies it to samplers that can return measurements relatively quickly (in minutes). This leads to optimal detect to warn architectures, which minimize the expected time to detection. Using a model of a real, large, commercial building, we demonstrate the approach by optimizing networks against uncertain release locations, source terms, and sampler characteristics. Finally, we speculate on rules of thumb for general sampler placement.

99 GENERAL AND MISCELLANEOUS↗

Indoor Sampler Siting

Contaminant releases in or near a building can lead to significant human exposures unless prompt response is taken. U.S. Federal and local agencies are implementing programs to place air-monitoring samplers in buildings to quickly detect biological agents. We describe a probabilistic algorithm for siting samplers in order to detect accidental or intentional releases of biological material. The algorithm maximizes the probability of detecting a release from among a suite of realistic scenarios. The scenarios may differ in any unknown, for example the release size or location, weather, mode of building operation, etc. The algorithm also can optimize sampler placement in the face of modeling uncertainties, for example the airflow leakage characteristics of the building, and the detection capabilities of the samplers. In an illustrative example, we apply the algorithm to a hypothetical 24-room commercial building, finding optimal networks for a variety of assumed sampler types and performance characteristics. We also discuss extensions of this work for detecting ambient pollutants in buildings, and for understanding building-wide airflow, pollutant dispersion, and exposures.

54 ENVIRONMENTAL SCIENCES↗

Kernel Density Estimators for SAMPLER Analyses [Slides]

This presentation discusses Sampler, specifically in terms of uncertainty quantification and states that for many simulation tasks nominal input parameters have complicated influence on the uncertainty in the final result. Sampler provides a convenient means to perform stochastic uncertainty quantification, brute force sampling parameter space and tallying changes in outputs, and it can be coupled with any SCALE modules. Perturbed responses can be collected and analyzed with standard statistical measures; however, two problems have been identified. The first problem is that for Monte Carlo simulations the individual response uncertainties are ignored, and the second problem is that features of distributions are easily hidden in histograms. They found that the solution is to add Kernel Density Estimator (KDE) analysis to the Sampler output. In conclusion, Sampler is a unique tool for stochastic uncertainty propagation, and it can be coupled with any module in SCALE. Current functionality is limited to histograms, and it may not adequately account for sample uncertainties and/or not adequately display underlying distribution features. Work is in progress to implement KDE in the Sampler module and no additional flagging is needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crossing the Streams – Sampler and the TemplateEngine [Slides]

This presentation discusses Sampler, which is a versatile UQ and parametric study tool that can be applied to any SCALE Sequence. Sampler can perturb any quantity in any SCALE input. Recent work at ORNL has developed new types of covariance data that allow Sampler UQ to be applied to nearly all SCALE applications, including reactor depletion, UNF fuel characterization, source term analysis, and decay heat calculation. In SCALE 6.2 releases, CE data in transport cannot be perturbed. Sampler was originally designed for stochastic sampling with any sequence within SCALE and Parametric capability added in SCALE 6.2.2. Sampler can be used for uncertainty quantification, including sample data in static or depletion calculations and sample inputs for uncertainties in compositions and dimensions. The SCALE TemplateEngine allows for expanding templates to full inputs and the combination provides a powerful UQ tool.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remote Sampler Demonstration Isolok Configuration Test

The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of source-location algorithms for atmospheric samplers

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Solid sorbent air sampler

A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

Galen, T. J.↗

Enhanced surface sampler and process for collection and release of analytes

An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

36 MATERIALS SCIENCE↗

Application of an in-situ soil sampler for assessing subsurface biogeochemical dynamics in a diesel-contaminated coastal site during soil flushing operations

Subsurface biogeochemistry and contaminant dynamics during the remediation of diesel-contamination by in-situ soil flushing were investigated at a site located in a coastal region. An in-situ sampler containing diesel-contaminated soils separated into two size fractions (<0.063- and <2-mm) was utilized in two monitoring wells: DH1 (located close to the injection and extraction wells for in-situ soil flushing) and DH2 (located beyond sheet piles placed to block the transport of leaked diesel). Total petroleum hydrocarbon (TPH) concentrations and biogeochemical properties were monitored both in soil and groundwater for six months. A shift occurred in the groundwater type from Ca-HCO 3 to Na-CI due to seawater intrusion during intense pumping, while the concentrations of Ni, Cu, Co, V, Cr, and Se increased substantially following surfactant (TWEEN 80) injection. The in-situ sampler with fine particles was more sensitive to variations in conditions during the remedial soil flushing process. In both wells, soil TPH concentrations in the <0.063-mm fraction were much higher than those in the <2-mm fraction. Increases in soil TPH in DH1 were consistent with the expected outcomes following well pumping and surfactant injection used to enhance TPH extraction. However, the number of diesel-degrading microorganisms decreased after surfactant injection. 16S-rRNA gene-based analysis also showed that the community composition and diversity depended on both particle size and diesel contamination. The multidisciplinary approach to the contaminated site assessments showed that soil flushing with surfactant enhanced diesel extraction, but negatively impacted in-situ diesel biodegradation as well as groundwater quality. In conclusion, the results also suggest that the in-situ sampler can be an effective monitoring tool for subsurface biogeochemistry as well as contaminant dynamics.

02 PETROLEUM↗

Formed Core Sampler Hydraulic Conductivity Testing

A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efficacy of passive sampler collection for atmospheric NO 2 isotopes under simulated environmental conditions

Rationale Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide‐ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. Methods The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 – ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter‐calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 – or nitrate (NO 3 – ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. Results δ 15 N‐NO 2 values determined from passive NO 2 collection, in conditions of 11–34 °C, 1–78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O‐NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Conclusions Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N‐NO 2 values and a precise method for determining atmospheric δ 18 O‐NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2 isotopic compositions. Copyright © 2017 John Wiley & Sons, Ltd.

Coughlin, Justin G.↗

Efficient Quantum Gibbs Samplers with Kubo–Martin–Schwinger Detailed Balance Condition

Lindblad dynamics and other open-system dynamics provide a promising path towards efficient Gibbs sampling on quantum computers. In these proposals, the Lindbladian is obtained via an algorithmic construction akin to designing an artificial thermostat in classical Monte Carlo or molecular dynamics methods, rather than being treated as an approximation to weakly coupled system-bath unitary dynamics. Recently, Chen, Kastoryano, and Gilyén (arXiv:2311.09207) introduced the first efficiently implementable Lindbladian satisfying the Kubo–Martin–Schwinger (KMS) detailed balance condition, which ensures that the Gibbs state is a fixed point of the dynamics and is applicable to non-commuting Hamiltonians. This Gibbs sampler uses a continuously parameterized set of jump operators, and the energy resolution required for implementing each jump operator depends only logarithmically on the precision and the mixing time. In this work, we build upon the structural characterization of KMS detailed balanced Lindbladians by Fagnola and Umanità, and develop a family of efficient quantum Gibbs samplers using a finite set of jump operators (the number can be as few as one), akin to the classical Markov chain-based sampling algorithm. Compared to the existing works, our quantum Gibbs samplers have a comparable quantum simulation cost but with greater design flexibility and a much simpler implementation and error analysis. Moreover, it encompasses the construction of Chen, Kastoryano, and Gilyén as a special instance.

97 MATHEMATICS AND COMPUTING↗

Efficiency tests of samplers for microbiological aerosols, a review

To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.

Henningson, E.↗

Propagation delay measurements from a timing sampler intended for use in space

A 3-micron CMOS timing sampler is described which is a test circuit designed into the Jet Propulsion Labs' CRRES chip to be flown on the Combined Release and Radiation Effects Satellite (CRRES). The timing sampler consists of 64 inverter-pair stages with sampling latches and decoder circuitry. The sampler is used to measure inverter-pair propagation delays, which are nominally 2.5 ns, with a resolution of 100 ps. A simple model was developed to explain the radiation-induced inverter-pair delay shifts in terms of radiation-induced MOSFET threshold-voltage shifts and effective modal capacitances. The magnitude of the shift in pair delay with radiation was estimated at the point where the n-MOSFET threshold voltage became zero. For a 0.7-V-threshold shift, the pair delay increased from its preradiation value by 360 ps for a rising step input and decreased by 190 ps for a falling step input.

Blaes, B. R.↗

Active Hydrazine Vapor Sampler (AHVS)

The Active Hydrazine Vapor Sampler (AHVS) was developed to detect vapors of hydrazine (HZ) and monomethylhydrazine (MMH) in air at parts-per-billion (ppb) concentration levels. The sampler consists of a commercial personal pump that draws ambient air through paper tape treated with vanillin (4-hydroxy-3-methoxybenzaldehyde). The paper tape is sandwiched in a thin cardboard housing inserted in one of the two specially designed holders to facilitate sampling. Contaminated air reacts with vanillin to develop a yellow color. The density of the color is proportional to the concentration of HZ or MMH. The AHVS can detect 10 ppb in less than 5 minutes. The sampler is easy to use, low cost, and intrinsically safe and contains no toxic material. It is most beneficial for use in locations with no laboratory capabilities for instrumentation calibration. This paper reviews the development, laboratory test, and field test of the device.

Young, Rebecca C.↗

Hydrothermal Vent Sampler: Does Life Exist in High Temperature Environments?

The main purpose of this research is to search for the existence of biomass under extreme temperature and pressure conditions to determine the upper bounds of environments on which life can exist. Vents are, simply put, underwater volcano openings located at the bottom of the sea. The conditions at these locations are considerably extreme with pressures of up to 10,000 psi, and enormous temperature gradients. The temperature of the water near these vents is around 400 C, while that of the surrounding water is about 3 C. The extremity of these conditions makes it hard to estimate the existence of life in those environments. I n order to find whether such existence happens, we need to search for biomass inside these vents. The vent sampler is a device that has the purpose of safely and accurately collecting this biomass for examination. This sampler is constituted of a Series of filters of the order of 100-0.2 microns in size. Since this is a 3-year project, it has not concluded yet; however, during the time I contributed to this project, I worked with the mechanical design of this sampler device including the selection, assembly, and testing of the various subsystems and the design and construction of the electronics enclosure.

Rivadeneyra, Cesar R.↗

Partially Collapsed Gibbs Samplers for Linear Inverse Problems and Applications to X-ray Imaging

Deblurring is one of the most common linear inverse problems in imaging, and most methods for deblurring an image assume that the convolution kernel, the so-called point spread function (PSF), is known or attempt to reconstruct the PSF simultaneously with the image. For many experimental imaging systems, like high energy X-ray radiography systems, the PSF must be computed from calibration imagery. The associated inverse problem is large-scale, so, in order to compute meaningful uncertainties with the reconstruction, it is common to use hierarchical Bayesian models and Markov chain Monte Carlo methods for sampling from the posterior. Classical Gibbs samplers can suffer from long autocorrelation lengths in the Markov chain when the reconstructed quantity in the inverse problem is finely discretized, resulting in poor computational efficiency of the Markov chain. In this work we present partially collapsed Gibbs samplers for linear inverse problems that greatly decrease correlations in the Markov chain, thus increasing the computational efficiency of the algorithms, and we present the results of the enhanced samplers on the problem of reconstructing the point spread function for an X-ray imaging system at the U.S. Department of Energy's Nevada National Security Site.

97 MATHEMATICS AND COMPUTING↗

Spatiotemporal Changes in Trace Metal Bioavailability in the Sediment Pore water of a Constructed Wetland Using Passive Pore water Samplers

Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

54 ENVIRONMENTAL SCIENCES↗