Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAXS/WAXS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

27 records · Page 2

Shape-Shifting Peptide Nanomaterials: Surface Asymmetry Enables pH-Dependent Formation and Interconversion of Collagen Tubes and Sheets

The fabrication of dynamic, transformable biomaterials that respond to environmental cues represents a significant step forward in the development of synthetic materials that rival their highly functional, natural counterparts. In this work, we describe the design and synthesis of crystalline supramolecular architectures from charge-complementary heteromeric pairs of collagen-mimetic peptides (CMPs). Under appropriate conditions, CMP pairs spontaneously assemble into either 1D ultraporous (pore diameter >100 nm) tubes or 2D bilayer nanosheets due to the structural asymmetry that arises from heteromeric self-association. Crystalline collagen tubes represent a heretofore unobserved morphology of this common biomaterial. In-depth structural characterization from a suite of biophysical methods, including TEM, AFM, high-resolution cryo-EM, and SAXS/WAXS measurements, reveals that the sheet and tube assemblies possess a similar underlying lattice structure. The experimental evidence suggests that the tubular structures are a consequence of the self-scrolling of incipient 2D layers of collagen triple helices and that the scrolling direction determines the formation of two distinct structural isoforms. Furthermore, we show that nanosheets and tubes can spontaneously interconvert through manipulation of the assembly pH and systematic adjustment of the CMP sequence. Altogether, we establish initial guidelines for the construction of dynamically responsive 1D and 2D assemblies that undergo a structurally programmed morphological transition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decoupling copolymer, lipid and carbon nanotube interactions in hybrid, biomimetic vesicles

Bilayer vesicles that mimic a real biological cell can be tailored to carry out a specific function by manipulating the molecular composition of the amphiphiles. These bio-inspired and bio-mimetic structures are increasingly being employed for a number of applications from drug delivery to water purification and beyond. Complex hybrid bilayers are the key building blocks for fully synthetic vesicles that can mimic biological cell membranes, which often contain a wide variety of molecular species. While the assembly and morpholgy of pure phospholid bilayer vesicles is well understood, the functionality and structure dramaticlly changes when copolymer and/or carbon nanotube porins (CNTP) are added. The aim of this study is to understand how the collective molecular interactions within hybrid vesicles affect their nanoscale structure and properties. In situ small and wide angle X-ray scattering (SAXS/WAXS) and molecular dynamics simulations (MD) are used to investigate the morphological effect of molecular interactions between polybutadiene polyethylene oxide, lipids and carbon nanotubes (CNT) within the hybrid vesicle bilayer. Within the lipid/copolymer system, the hybrid bilayer morphology transitions from phase separated lipid and compressed copolymer at low copolymer loadings to a mixed bilayer where opposing lipids are mostly separated from the inner region. This transition begins between 60 wt% and 70 wt%, with full homogenization observed by 80 wt% copolymer. The incorporation of CNT into the hybrid vesicles increases the bilayer thickness and enhances the bilayer symmetry. Analysis of the WAXS and MD indicate that the CNT–dioleoyl interactions are much stronger than the CNT–polybutadiene.

59 BASIC BIOLOGICAL SCIENCES↗

Shear-induced polydomain structures of nematic lyotropic chromonic liquid crystal disodium cromoglycate

Lyotropic chromonic liquid crystals (LCLCs) represent aqueous dispersions of organic disk-like molecules that form cylindrical aggregates. Despite the growing interest in these materials, their flow behavior is poorly understood. Here, we explore the effect of shear on dynamic structures of the nematic LCLC, formed by 14 wt% water dispersion of disodium cromoglycate (DSCG). We employ in situ polarizing optical microscopy (POM) and small-angle and wide-angle X-ray scattering (SAXS/WAXS) to obtain independent and complementary information on the director structures over a wide range of shear rates. The DSCG nematic shows a shear-thinning behavior with two shear-thinning regions (Region I at $\dot{\gamma}$ < 1 s -1 and Region III at $\dot{\gamma}$ > 10 s -1 ) separated by a pseudo-Newtonian Region II (1 s-1 < $\dot{\gamma}$ < 10 s -1 ). The material is of a tumbling type. In Region I, $\dot{\gamma}$ < 1 s -1 , the director realigns along the vorticity axis. An increase of [small gamma, Greek, dot above] above 1 s -1 triggers nucleation of disclination loops. The disclinations introduce patches of the director that deviates from the vorticity direction and form a polydomain texture. Extension of the domains along the flow and along the vorticity direction decreases with the increase of the shear rate to 10 s -1 . Above 10 s -1 , the domains begin to elongate along the flow. At $\dot{\gamma}$ > 100 s -1 , the texture evolves into periodic stripes in which the director is predominantly along the flow with left and right tilts. The period of stripes decreases with an increase of $\dot{\gamma}$. The shear-induced transformations are explained by the balance of the elastic and viscous energies. In particular, nucleation of disclinations is associated with an increase of the elastic energy at the walls separating nonsingular domains with different director tilts. The uncovered shear-induced structural effects would be of importance in the further development of LCLC applications.

36 MATERIALS SCIENCE↗

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗

Data Mining of Polymer Phase Transitions upon Temperature Changes by Small and Wide-Angle X-ray Scattering Combined with Raman Spectroscopy

The complex physical transformations of polymers upon external thermodynamic changes are related to the molecular length of the polymer and its associated multifaceted energetic balance. The understanding of subtle transitions or multistep phase transformation requires real-time phenomenological studies using a multi-technique approach that covers several length-scales and chemical states. A combination of X-ray scattering techniques with Raman spectroscopy and Differential Scanning Calorimetry was conducted to correlate the structural changes from the conformational chain to the polymer crystal and mesoscale organization. Current research applications and the experimental combination of Raman spectroscopy with simultaneous SAXS/WAXS measurements coupled to a DSC is discussed. In particular, we show that in order to obtain the maximum benefit from simultaneously obtained high-quality data sets from different techniques, one should look beyond traditional analysis techniques and instead apply multivariate analysis. Data mining strategies can be applied to develop methods to control polymer processing in an industrial context. Crystallization studies of a PVDF blend with a fluoroelastomer, known to feature complex phase transitions, were used to validate the combined approach and further analyzed by MVA.

36 MATERIALS SCIENCE↗

Extended q -Range X-Ray Scattering Reveals High-Resolution Structural Details of Biomacromolecules in Aqueous Solutions

Here, we communicate a feasibility study for high-resolution structural characterization of biomacromolecules in aqueous solution from X-ray scattering experiments measured over a range of scattering vectors (q) that is approximately two orders of magnitude wider than used previously for such systems. Scattering data with such an extended q-range enables the recovery of the underlying real-space atomic pair distribution function, which facilitates structure determination. We demonstrate the potential of this method for biomacromolecules using several types of cyclodextrins (CD) as model systems. We successfully identified deviations of the tilting angles for the glycosidic units in CDs in aqueous solutions relative to their values in the crystalline forms of these molecules. Such level of structural detail is inaccessible from standard small angle scattering measurements. Our results call for further exploration of ultra-wide-angle X-ray scattering measurements for biomacromolecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Solvation Behavior of the Saturated Electrolytes with Small/Wide-Angle X-ray Scattering and Raman Spectroscopy

Concentrated electrolytes are attracting significant attention because the solvation structures could stabilize the interface, encouraging novel electrolyte development for high-voltage and long-cycle-life batteries. Saturated electrolytes, which have the highest salt concentrations, have been rarely studied because of their shortcomings of high viscosity and low ionic conductivity. Nevertheless, the exciting solvation structure in saturated solution is still worth studying, significantly broadening the comprehensive understanding of the solvation processes. In this work, we investigate the saturated lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) dissolved in seven different organic solvents, including propylene carbonate (PC), tetrahydrofuran (THF), acetonitrile (ACN), dimethylformamide (DMF), 1,2-dimethoxyethane (DME), diethylene glycol dimethyl ether (Diglyme), and tetraethylene glycol dimethyl ether (Tetraglyme). The combined small/wide-angle X-ray scattering and Raman spectroscopy are employed to study the global and local solvation structure. Here, this work demonstrates a method for detecting the structure of liquids, which will facilitate the study of structure–performance relationships and the screening of new electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning structural mapping at the Life Science X-ray Scattering Beamline

This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.

36 MATERIALS SCIENCE↗

Preparing research samples for safe arrival at centers and facilities: recipes for successful experiments

Preparation of biomacromolecules for structural biology studies is a complex and time-consuming process. The goal is to produce a highly concentrated, highly pure product that is often shipped to large facilities with tools to prepare the samples for crystallization trials or for measurements at synchrotrons and cryoEM centers. The aim of this article is to provide guidance and to discuss general considerations for shipping biomacromolecular samples. Details are also provided about shipping samples for specific experiment types, including solution- and cryogenic-based techniques. These guidelines are provided with the hope that the time and energy invested in sample preparation is not lost due to shipping logistics.

36 MATERIALS SCIENCE↗