Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Methods for radiological assessment of C-14 in air effluents - 15419

The purpose of this paper is to report on methods used for the assessment of -dose significant- C-14 being discharged into the air from nuclear facilities. GEL laboratories, LLC and GEL Engineering LLC, (GEL) undertook the task of developing new and improved methods to better identify the release of C-14 in the various chemical forms released from nuclear reactors and fuel reprocessing facilities. To completely understand the environmental releases and impact to the public a two-step approach was selected. The first step was to develop a sampling method that would enable an accurate assessment of the ratio of C-14 discharged as carbon dioxide compared to organic gases like methane. This is very important to dose modeling calculations to members of the public. Once this ratio was understood, the second step was to develop a method to track inorganic forms of C-14 with standard environmental air monitoring equipment and achieve a detection limit that was in line with NRC 10CFR Appendix I dose modeling requirements. GEL development efforts focused on using a solid sample cartridge that would fit into standard air sampling equipment used at nuclear plants. The cartridge and sorbent needed to be capable of running 7 days at 24 hours per day and not saturate with stable carbon dioxide. The process developed for analyzing the sorbent involves chemically removing the carbon dioxide and ultimately counting by liquid scintillation counting. The method yields a detection limit for C-14 of 0.02 Bq/m{sup 3} which provides a dose calculation of approximately 0.1 mSv/yr when applied to the child model. This paper will describe the methods and results used to determine field environmental monitoring for C-14 using GEL cartridges also known as -GELsorb C14-. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New determination of the 229 Th half-life

A new determination of the 229 Th half-life was made based on measurements of the 229 Th massic activity of a high-purity solution for which the 229 Th molality had previously been measured. The 229 Th massic activity was measured by direct comparison with SRM 4328C using 4παβ liquid scintillation counting, NaI counting, and standard addition liquid scintillation counting. The 229Th massic activity was confirmed by isotope dilution alpha spectrometry measurements. The 229 Th half-life calculated from the activity measurements is (7825 ± 87) years (k = 2).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Situ Measurement of Tritium Permeation Through Stainless Steel

The TMIST-2 irradiation experiment was conducted in the Advanced Test Reactor at Idaho National Laboratory to evaluate tritium permeation through Type 316 stainless steel (316 SS). The interior of a 316 SS seamless tube specimen was exposed to a 4He carrier gas mixed with a specified quantity of tritium (T2) to yield partial pressures of 0.1, 5, and 50 Pa at 292° and 330°C. In-situ tritium permeation measurements were made by passing a He-Ne sweep gas over the outer surface of the specimen to carry the permeated tritium to a bubbler column for liquid scintillation counting. An irradiation enhancement factor (IEF) was determined by comparing in-situ permeation data with a correlation for ex-reactor hydrogen permeation through austenitic stainless steel developed from literature data and reported by Le Claire. Nominal values for the IEF ranged between 3 and 5 for 316 SS. In-situ permeation data were also used to derive an in-reactor permeation correlation as a function of temperature and pressure. In addition, the triton recoil contribution to tritium permeation, which results from the transmutation of 3He to T, was also evaluated by introducing a 4He carrier gas mixed with 3He at a partial pressure of 1013 Pa at 330°C. Less than 3% of the tritium resulting from 3He transmutation contributed to tritium permeation.

In-Reactor↗

Comparative testing of various flow-cell detectors fabricated using CaF{sub 2} solid scintillator

A monitoring system based on a flow-cell detector was developed for measuring the tritium concentration in water. The flow-cell detector was fabricated using a granular CaF{sub 2} solid scintillator. This system does not use a liquid scintillation counting system and does not generate radioactive organic liquid waste. Moreover, continuous real-time measurements are possible, in contrast to a liquid scintillation counting system, which requires batch measurements. For further development of the system, four flow-cell detectors were fabricated. They included a single 3-mm-diameter cell, three 3-mm-diameter cells in series, a single 5-mm-diameter cell, and three 5-mm-diameter cells in series. Continuously flowing water containing tritium at various concentrations was passed through the flow cells, and tritium count were measured for 600 and 10000 s. Investigating the relation between the count rate and concentration, the three 5-mm-diameter cells were most sensitive, with a linear relation maintained down to approximately 2 Bq/ml and 10 Bq/ml for 10000- and 600-s measurements, respectively. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Laboratory Counting and Radiochemistry Group Equipment and Capabilities

The Analytical Laboratory at the Materials and Fuels Complex provides quality analytical results through a variety of instrumental methods. The work of the Counting and Radiochemistry Group focuses on several instrumental techniques: Gamma Spectrometry, Liquid Scintillation Counting, Gas Flow Proportional Counting, and Alpha Spectrometry. This talk will focus on an overview of the Counting and Radiochemistry's capabilities, and will briefly discuss some of the sample preparation methods currently in use by the group.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Redox and volatility of Tc(CO)3 + compounds in waste glass melting

The behavior of non-pertechnetate (Tc(I)) species was studied by preparing three portions of dried low-activity waste-glass simulated feed, combining it with either the [fac-Tc(CO) (OH)] “tetramer,” the [fac-Tc(CO) (OH)(H O) ] “monohydroxo,” or the [fac-Tc(CO) Cl ] “trichloro,” and then heating samples to 600, 800, and 1000 °C. For the feeds and the heat-treated samples, Tc concentrations were measured by liquid scintillation counting (LSC) after NaOH and HNO fusion, and the results were used to determine the Tc volatility. For unheated samples and samples heated to 600 °C, the speciation of Tc was measured by X-ray absorption near-edge structure (XANES) analysis, while partitioning of Tc in the glass-forming melt was determined by leaching the samples in water and measuring the Tc concentration of the leachate. The current results are discussed in connection with previously reported data for Tc(VII) and Tc(IV) species to rationalize the potential mechanism on how different speciation of Tc affect its retention in glass. 3 4 3 2 2 3 3 3 2-

Luksic, SA↗

International inter-comparison exercise on $${}^{153}\hbox {Sm}$$153Sm

Samarium-153 ( 153 Sm) is one of the many isotopes of interest to the nuclear forensics community. This short-lived radionuclide decays to stable europium-153 via beta emission, with subsequent de-excitation via gamma emission and internal conversion. Historical measurements of 153 Sm by gamma spectrometry and beta liquid scintillation counting have shown a low bias compared to beta proportional counting. In order to investigate this, four national laboratories jointly conducted an experimental inter-comparison exercise on a certified 153Sm sample, created from neutron activation of samarium-152. Radiometric measurements were conducted using gamma spectrometry, liquid scintillation, gas proportional counting, and passivated implanted planar silicon detectors and compared across the four institutions against the certificate. The results from this experiment are presented together with a number of conclusions which suggest that the current published cumulative fission yield for 153 Sm, as used by many laboratories, is approximately 15% high and is the likely cause of the previously observed historical bias.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of {sup 210}Pb and its Application to Evaluate Contamination in an Area Affected by NORM Releases

Liquid scintillation counting (LSC) is an easy and straightforward technique, and combined with its low limit of detection, makes it a powerful tool for both routine and low level measurements that can be applied to {sup 210}Pb low level counting in environmental samples. {sup 210}Pb can be easily measured following a sulphate co-precipitation method; the addition of a carrier and the weighing of the recovered amount is a widespread technique to evaluate radiochemical yield, however, this evaluation of the recovery is sometimes questioned. The samples employed in this work were recollected in 1999 and 2005 from the estuary of the Odiel and Tinto rivers (SW of Spain), which were affected by phosphogypsum (pg.) discharges until 1998. Phosphogypsum contains most of the {sup 210}Pb from the treated raw material, for that reason analysed riverbed sediments have enhanced {sup 210}Pb activity concentrations and hence, enhanced activity concentration of its daughter {sup 210}Po, both in secular equilibrium after two years.

54 ENVIRONMENTAL SCIENCES↗

Simplified Method for the In Situ Collection and Laboratory Analysis of Cosmogenic Tracers (Sulfur-35 and Sodium-22) to Determine Residence Time Distributions and Water Ages

The use of cosmogenically produced sulfur-35 (T 1/2 = 87 days) and sodium-22 (T 1/2 = 2.6 years) as intrinsic tracers can provide valuable information on catchment hydrology, flow paths, and subsurface storage. A new and straightforward method was created to determine the activities of both 35 S and 22 Na in various water sources by pumping large volumes (up to 1000 L) of water through cation- and anion-exchange resin columns in the field to collect sodium and sulfate ions and simple chemistry in the lab. Samples are counted for 35 S using liquid scintillation counting (LSC) and for 22 Na via γ spectroscopy. Our novel in situ method provides faster sample throughput as well as better counting statistics and lower detection limits. Both methods were successfully applied at the Southern Sierra Critical Zone Observatory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a low background liquid scintillation counter for a shallow underground laboratory

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

liquid scintillation counting↗

Remote analysis of high-tritium-content water

Systems to safely analyze for tritium in moisture collected from glovebox atmospheres are being developed for use at Savannah River Site (SRS) tritium facilities. Analysis results will guide whether the material contains sufficient tritium for economical recovery, or whether it should be stabilized for disposal as waste. In order to minimize potential radiation exposures that could occur in handling and diluting high-tritium-content water, SRS sought alternatives to the process laboratory's routine analysis by liquid-scintillation counting. The newer systems determine tritium concentrations by measuring bremsstrahlung radiation induced by low-energy beta interactions. One of the systems determines tritium activity in liquid streams, the other determines tritium activity in water vapor. Topics discussed include counting results obtained by modeling and laboratory testing and corrections that are made for low-energy photon attenuation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dismantling of the PETRA glove box: tritium contamination and inventory assessment

The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followed by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Micro-Optical Ring Electrode: A Sensor for Multiple Actinide Ions Monitoring - 17586

We present on the development of the Micro-Optical Ring Electrode (MORE) for the analysis of trans-uranium elements in aqueous mixtures. The MORE is a photo-electrochemical device based on a ring microelectrode that uses the insulator interior to the ring as a light guide. This single device exploits the unique photophysical and electrochemical properties of multiple analytes present in mixtures to quantify them. Our study aims to develop a protocol for the analysis of ions of uranium, neptunium and plutonium, which are most relevant to the nuclear industry, especially in the areas of decommissioning and fuel reprocessing, where speedy and safe identification of radioactive contaminants is essential. The technique offers a number of advantages over traditional methods in the area of radiochemical analysis such as real time monitoring in-situ, reduced radiation dose impact to the analyst as a result of greatly reduced sample handling and preparation, improved analysis times allowing quick decision making, at a much reduced cost (e.g. compared to ICP-MS and Scintillation counting). Here we present results of our study on non-radioactive surrogates for the target elements and discuss the advantages the technique can deliver to the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Half-life of {sup 151}Sm remeasured

The half-life of {sup 151}Sm was redetermined and compared with literature values. A {sup 151}Sm{sub 2}O{sub 3} sample was produced by exposing {sup 150}Sm{sub 2}O{sub 3} to the high neutron flux of the heavy water research reactor at the China Institute of Atomic Energy (CIAE). The number of atoms and the activity of {sup 151}Sm in the sample were measured by thermal ionization mass spectrometry (TIMS) and liquid scintillation counting (LSC), respectively. The half-life of {sup 151}Sm determined in this work is 96.6 yr, with a standard uncertainty of 2.4 yr based on a quadratic summation of the uncertainty components from the measurements of the number of atoms and the activity of {sup 151}Sm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiochemical Characterization of PWR Control Rods - 19030

NRG has, in cooperation with the German partner Hoefer and Bechtel, performed a radiochemical characterization of the control rods from a German Pressurized Water Reactor. To perform the cutting and sampling of the spent control rods at the reactor site NRG has developed a dedicated, remotely operated tool. This tool enabled the sampling of both the stainless steel tube and the absorber material from the upper, middle and lower parts of selected rods. The samples were transported from the reactor site to NRG's laboratories at Petten, the Netherlands, were they were analysed chemically and radiologically. Due to the different chemical constitution of the control rod tubes and the absorber, the procedures for the chemical separation of the different compounds, prior to the radiological characterization, varied. The route for the stainless steel tube samples turned out more complex than that for the absorber samples: there are more nuclides to be determined, and therefore more treatment steps and component separations were necessary. Subsequently to the component separations, the radiochemical characterization was performed using alpha and gamma spectrometry and the Liquid Scintillation Counting (LSC) technique. The results of the measurements in combination with simulations performed with a reactor physics code provided for a better understanding about the distribution of radionuclides in absorber rods, both in the rod tubes and the absorber core. In addition, the results of the measurements can be used to validate reactor physics codes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗