Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Redox and volatility of Tc(CO)3 + compounds in waste glass melting

The behavior of non-pertechnetate (Tc(I)) species was studied by preparing three portions of dried low-activity waste-glass simulated feed, combining it with either the [fac-Tc(CO) (OH)] “tetramer,” the [fac-Tc(CO) (OH)(H O) ] “monohydroxo,” or the [fac-Tc(CO) Cl ] “trichloro,” and then heating samples to 600, 800, and 1000 °C. For the feeds and the heat-treated samples, Tc concentrations were measured by liquid scintillation counting (LSC) after NaOH and HNO fusion, and the results were used to determine the Tc volatility. For unheated samples and samples heated to 600 °C, the speciation of Tc was measured by X-ray absorption near-edge structure (XANES) analysis, while partitioning of Tc in the glass-forming melt was determined by leaching the samples in water and measuring the Tc concentration of the leachate. The current results are discussed in connection with previously reported data for Tc(VII) and Tc(IV) species to rationalize the potential mechanism on how different speciation of Tc affect its retention in glass. 3 4 3 2 2 3 3 3 2-

Luksic, SA↗

International inter-comparison exercise on $${}^{153}\hbox {Sm}$$153Sm

Samarium-153 ( 153 Sm) is one of the many isotopes of interest to the nuclear forensics community. This short-lived radionuclide decays to stable europium-153 via beta emission, with subsequent de-excitation via gamma emission and internal conversion. Historical measurements of 153 Sm by gamma spectrometry and beta liquid scintillation counting have shown a low bias compared to beta proportional counting. In order to investigate this, four national laboratories jointly conducted an experimental inter-comparison exercise on a certified 153Sm sample, created from neutron activation of samarium-152. Radiometric measurements were conducted using gamma spectrometry, liquid scintillation, gas proportional counting, and passivated implanted planar silicon detectors and compared across the four institutions against the certificate. The results from this experiment are presented together with a number of conclusions which suggest that the current published cumulative fission yield for 153 Sm, as used by many laboratories, is approximately 15% high and is the likely cause of the previously observed historical bias.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of {sup 210}Pb and its Application to Evaluate Contamination in an Area Affected by NORM Releases

Liquid scintillation counting (LSC) is an easy and straightforward technique, and combined with its low limit of detection, makes it a powerful tool for both routine and low level measurements that can be applied to {sup 210}Pb low level counting in environmental samples. {sup 210}Pb can be easily measured following a sulphate co-precipitation method; the addition of a carrier and the weighing of the recovered amount is a widespread technique to evaluate radiochemical yield, however, this evaluation of the recovery is sometimes questioned. The samples employed in this work were recollected in 1999 and 2005 from the estuary of the Odiel and Tinto rivers (SW of Spain), which were affected by phosphogypsum (pg.) discharges until 1998. Phosphogypsum contains most of the {sup 210}Pb from the treated raw material, for that reason analysed riverbed sediments have enhanced {sup 210}Pb activity concentrations and hence, enhanced activity concentration of its daughter {sup 210}Po, both in secular equilibrium after two years.

54 ENVIRONMENTAL SCIENCES↗

Simplified Method for the In Situ Collection and Laboratory Analysis of Cosmogenic Tracers (Sulfur-35 and Sodium-22) to Determine Residence Time Distributions and Water Ages

The use of cosmogenically produced sulfur-35 (T 1/2 = 87 days) and sodium-22 (T 1/2 = 2.6 years) as intrinsic tracers can provide valuable information on catchment hydrology, flow paths, and subsurface storage. A new and straightforward method was created to determine the activities of both 35 S and 22 Na in various water sources by pumping large volumes (up to 1000 L) of water through cation- and anion-exchange resin columns in the field to collect sodium and sulfate ions and simple chemistry in the lab. Samples are counted for 35 S using liquid scintillation counting (LSC) and for 22 Na via γ spectroscopy. Our novel in situ method provides faster sample throughput as well as better counting statistics and lower detection limits. Both methods were successfully applied at the Southern Sierra Critical Zone Observatory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a low background liquid scintillation counter for a shallow underground laboratory

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

liquid scintillation counting↗

Remote analysis of high-tritium-content water

Systems to safely analyze for tritium in moisture collected from glovebox atmospheres are being developed for use at Savannah River Site (SRS) tritium facilities. Analysis results will guide whether the material contains sufficient tritium for economical recovery, or whether it should be stabilized for disposal as waste. In order to minimize potential radiation exposures that could occur in handling and diluting high-tritium-content water, SRS sought alternatives to the process laboratory's routine analysis by liquid-scintillation counting. The newer systems determine tritium concentrations by measuring bremsstrahlung radiation induced by low-energy beta interactions. One of the systems determines tritium activity in liquid streams, the other determines tritium activity in water vapor. Topics discussed include counting results obtained by modeling and laboratory testing and corrections that are made for low-energy photon attenuation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dismantling of the PETRA glove box: tritium contamination and inventory assessment

The PETRA facility is the first installation in which experiments with tritium were carried out at the Tritium Laboratory Karlsruhe. After completion of two main experimental programs, the decommissioning of PETRA was initiated with the aim to reuse the glove box and its main still valuable components. A decommissioning plan was engaged to: -) identify the source of tritium release in the glove box, -) clarify the status of the main components, -) assess residual tritium inventories, and -) de-tritiate the components to be disposed of as waste. Several analytical techniques - calorimetry on small solid samples, wipe test followed by liquid scintillation counting for surface contamination assessment, gas chromatography on gaseous samples - were deployed and cross-checked to assess the remaining tritium inventories and initiate the decommissioning process. The methodology and the main outcomes of the numerous different tritium measurements are presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Micro-Optical Ring Electrode: A Sensor for Multiple Actinide Ions Monitoring - 17586

We present on the development of the Micro-Optical Ring Electrode (MORE) for the analysis of trans-uranium elements in aqueous mixtures. The MORE is a photo-electrochemical device based on a ring microelectrode that uses the insulator interior to the ring as a light guide. This single device exploits the unique photophysical and electrochemical properties of multiple analytes present in mixtures to quantify them. Our study aims to develop a protocol for the analysis of ions of uranium, neptunium and plutonium, which are most relevant to the nuclear industry, especially in the areas of decommissioning and fuel reprocessing, where speedy and safe identification of radioactive contaminants is essential. The technique offers a number of advantages over traditional methods in the area of radiochemical analysis such as real time monitoring in-situ, reduced radiation dose impact to the analyst as a result of greatly reduced sample handling and preparation, improved analysis times allowing quick decision making, at a much reduced cost (e.g. compared to ICP-MS and Scintillation counting). Here we present results of our study on non-radioactive surrogates for the target elements and discuss the advantages the technique can deliver to the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Half-life of {sup 151}Sm remeasured

The half-life of {sup 151}Sm was redetermined and compared with literature values. A {sup 151}Sm{sub 2}O{sub 3} sample was produced by exposing {sup 150}Sm{sub 2}O{sub 3} to the high neutron flux of the heavy water research reactor at the China Institute of Atomic Energy (CIAE). The number of atoms and the activity of {sup 151}Sm in the sample were measured by thermal ionization mass spectrometry (TIMS) and liquid scintillation counting (LSC), respectively. The half-life of {sup 151}Sm determined in this work is 96.6 yr, with a standard uncertainty of 2.4 yr based on a quadratic summation of the uncertainty components from the measurements of the number of atoms and the activity of {sup 151}Sm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiochemical Characterization of PWR Control Rods - 19030

NRG has, in cooperation with the German partner Hoefer and Bechtel, performed a radiochemical characterization of the control rods from a German Pressurized Water Reactor. To perform the cutting and sampling of the spent control rods at the reactor site NRG has developed a dedicated, remotely operated tool. This tool enabled the sampling of both the stainless steel tube and the absorber material from the upper, middle and lower parts of selected rods. The samples were transported from the reactor site to NRG's laboratories at Petten, the Netherlands, were they were analysed chemically and radiologically. Due to the different chemical constitution of the control rod tubes and the absorber, the procedures for the chemical separation of the different compounds, prior to the radiological characterization, varied. The route for the stainless steel tube samples turned out more complex than that for the absorber samples: there are more nuclides to be determined, and therefore more treatment steps and component separations were necessary. Subsequently to the component separations, the radiochemical characterization was performed using alpha and gamma spectrometry and the Liquid Scintillation Counting (LSC) technique. The results of the measurements in combination with simulations performed with a reactor physics code provided for a better understanding about the distribution of radionuclides in absorber rods, both in the rod tubes and the absorber core. In addition, the results of the measurements can be used to validate reactor physics codes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Imaging doxorubicin and polymer-drug conjugates of doxorubicin-induced cardiotoxicity with bispecific anti-myosin-anti-DTPA antibody and Tc-99m-labeled polymers

Background: Radiolabeled anti-myosin imaging is well-established for imaging doxorubicin-induced cardiotoxicity. However, to enable imaging of drug-induced cardiotoxicity in small experimental animals, pretargeting with bispecific anti-myosin-anti-DTPA-Fab-Fab’ and targeting with high-specific radioactivity Tc-99m-DTPA-succinylated-polylysine (DSPL) was developed. Methods: Mice were injected biweekly with 10 mg/kg Dox or its equivalent as D-Dox-PGA. Tc-99m-DSPL myocardial activity after pretargeting with bsAb-Fab-Fab’ was determined after gamma imaging performed at day 7 for Dox-treated mice and day 39 for all others. Results: Mice treated with 10 mg/kg Dox lost 10% total body weight in 1 week and 20% after a second dose. Pretargeted mice treated with 30 mg/kg cumulative D-Dox-PGA dose showed no loss of body weight for the duration of the study. Cardiotoxicity was confirmed by gamma imaging and scintillation counting (1.9 ± 0.25 [mean% ID/g ± SD]) after 1 dose of Dox. Mice injected with 3 × 10 mg/kg Dox equivalent as D-Dox-PGA (0.4 ± 0.04, P < .01) and untreated 2 control groups (0.20 ± 0.05 and 0.19 ± 0.04, P < .01) showed significantly lower myocardial anti-myosin radioactivity relative to the 10 mg/kg Dox group. Conclusion: Pretargeting with bsAb-Fab-Fab’ and targeting with Tc-99m labeled high-specific activity polymers enabled early visualization of doxorubicin induce cardiotoxicity in mice. Tolerated dose of D-Dox-PGA was greater than to 30 mg/kg Dox-equivalent dose with minimal cardiotoxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TMIST-2 Transport Test

In anticipation of the TMIST-2 experiment in the Advanced Test Reactor, there was a need to determine if the tritium that is expected to be observed at the outlet of the experiment would be seen or if it may be lost on its way from the experiment in the core to the measurement station. To assist in resolving that issue, a bench-scale experiment was conducted in the Idaho National Laboratory’s Safety and Tritium Applied Research (STAR) facility using deuterium and a mass spectrometer in lieu of tritium with ion chambers, bubblers, and scintillation counting. The experiment replicated the concentration of the hydrogen isotope, the flow rates anticipated, and the residence times. It was found that there was initial uptake on tubing walls, presumably due to oxidation of the hydrogen isotopes to water and adsorption or isotopic exchange, but that saturates relatively quickly, and once saturated, the concentration of deuterium at the outlet of the tubing system was essentially the same as it was at the experiment inlet under the conditions modeled in the experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Half-life and gamma abundance ratio measurements of Sm-153

The measurement of the decay of 153Sm was observed by gamma spectrometry, liquid scintillation counting and gas proportional counting in an attempt to confirm the half life and gamma abundance ratios for this isotope. Recent changes in the published nuclear decay data indicate that historical literature values may be biased. The 153Sm was made by the neutron activation of ultrapure isotopically enriched 152Sm to create 153Sm. The decay measurements were made over a three week period and no other isotopes were detected during this time. The gamma abundance ratio for the 103 keV gamma was measured to be (27.9%) which is 4% lower than the published data. In addition, the half life was 1.9308 days, which is 0.34% lower than the published data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the biomass fraction of mixed waste fuels: A comparison of existing industry and {sup 14}C-based methodologies

Highlights: • Compares industry standard and {sup 14}C methods for determining bioenergy content of MSW. • Differences quantified through study at an operational energy from waste plant. • Manual sort and selective dissolution are unreliable measures of feedstock bioenergy. • {sup 14}C methods (esp. AMS) improve precision and reliability of bioenergy determination. • Implications for electricity generators and regulators for award of bio-incentives. - Abstract: {sup 14}C analysis of flue gas by accelerator mass spectrometry (AMS) and liquid scintillation counting (LSC) were used to determine the biomass fraction of mixed waste at an operational energy-from-waste (EfW) plant. Results were converted to bioenergy (% total) using mathematical algorithms and assessed against existing industry methodologies which involve manual sorting and selective dissolution (SD) of feedstock. Simultaneous determinations using flue gas showed excellent agreement: 44.8 ± 2.7% for AMS and 44.6 ± 12.3% for LSC. Comparable bioenergy results were obtained using a feedstock manual sort procedure (41.4%), whilst a procedure based on selective dissolution of representative waste material is reported as 75.5% (no errors quoted). {sup 14}C techniques present significant advantages in data acquisition, precision and reliability for both electricity generator and industry regulator.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Tc(IV)-incorporated Fe minerals to enhance {sup 99}Tc retention in glass waste form - 15239

Iron minerals have been considered to be good hosts for Tc immobilization because the Tc(IV) ion substitutes for Fe(III) in the crystal structure of the Fe oxide due to similarities in (1) cation size [Tc(IV) = 78.5 pm; Fe(III) = 69 or 78.5 pm], (2) metal-oxygen interatomic distance (Tc-O = 0.199 nm, Fe-O = 0.203 nm), (3) number of coordinating oxygen atoms (both 6-fold coordinated), and (4) the redox potential (Eh=ca. +20 mV at pH = 7) for a redox couple between Tc(VII)/Tc(IV) and Fe(III)/Fe(II). Magnetite, maghemite, and trevorite are iron oxide minerals and all belong to spinel mineral group. Laboratory testing shows that Tc can be removed from aqueous waste solutions by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation with iron oxide minerals during recrystallization of Fe(OH){sub 2}(s) used as an initial solid precursor. X-ray absorption near edge structure (XANES) spectroscopy confirmed that Tc was in the +4 oxidation state in final Tc-Fe minerals. The Tc-incorporated Fe minerals (Tc-goethite and Tc-magnetite/maghemite) were also tested for Tc retention in glass melts at different temperatures between 600 - 1,000 deg.C in a furnace. After being cooled in air, the solid glass specimens collected at different temperatures were analyzed for Tc oxidation state using XANES and Tc retention using liquid scintillation counting (LSC). Although Tc(IV) started to re-oxidize at 600 deg.C, Tc retention in the final glass specimen prepared with Tc-incorporated Fe mineral at high temperatures was at least two times higher than glass prepared with KTcO{sub 4} salt. Higher Tc retention in glass is considered to result from limited and delayed Tc volatilization process due to Fe mineral encapsulation for Tc. Therefore, the results showing the presence of Tc(IV) in the Fe mineral structure indicate strong possibility to enhance Tc retention in borosilicate glass as well as to reduce the remediation costs at the Hanford Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Radioactivity Characteristics of the NPP Charcoal Sample Contaminated by Carbon-14 - 13531

The radioactivity of {sup 14}C-contaminated charcoal sample was analyzed by using a high temperature oxidation and liquid scintillation counting method. The radioactivity of the sample was monotonically increased according to the increase of the combustion time at each temperature where the experimental uncertainty was calculated in the 95 % confidence level. It showed that the {sup 14}C radioactivity was not completely extracted from the sample by simply increasing the combustion time unless the combustion temperature was high enough. The higher the combustion temperature was, the higher the recovery during the first 30 minutes was. The first 30 minute recoveries were 100 % at a temperature equal to or greater than 450 deg. C. The ratios of the recovery during the first 30 minutes to the total recovery during whole duration were more than 90 % at each experiment temperature. It was understood that the temperature was a critical factor for the complete removal of the {sup 14}C from the waste sample. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗