Studies of intensity and spectral composition of lunar gamma-radiation on the automatic station Luna-10
Lunik X scintillation spectrometer studies of lunar gamma radiation intensity and spectral composition
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lunik X scintillation spectrometer studies of lunar gamma radiation intensity and spectral composition
The paper describes an actively shielded, multicrystal scintillation spectrometer for measurement of the solar gamma ray flux used by the Solar Maximum Mission Gamma Ray Experiment. The instrument provides a 476-channel pulse height spectrum every 16.38 s over the 0.3-9 MeV energy range; the gamma ray spectral analysis can be extended to at least 15 MeV on command. The instrument is designed to measure the intensity, energy, and Doppler shift of narrow gamma ray lines, the intensity of extremely broadened lines, and the photon continuum.
The Oriented Scintillation Spectrometer Experiment (OSSE) was launched on NASA's Compton Observatory on 1991 April 5. OSSE uses large area scintillation detectors to undertake gamma-ray line and continuum observations in the 0.05-10 MeV energy range. During the first months of the mission, OSSE has obtained observations on a number of high priority sources including AGNs, SN1991T, the galactic center region, and several discrete galactic sources. The capabilities and performance of OSSE are discussed and initial results for several of the early observations are presented.
An emission feature near 170 keV, interpreted as Compton-backscattered 511 keV positron-annihilation radiation, has been reported twice by balloon-borne germanium spectrometers from within approximately 15 deg of the Galactic center (Leventhal, MacCallum, & Stang 1978; Smith et al. 1993). Upper limits on this feature set by HEAO 3 (Mahoney, Ling, & Wheaton 1993) and other instruments indicate that it must be transient. We have searched data from the Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma Ray Observatory (CGRO) for this feature, using daily spectral accumulations from all pointings near the Galactic center up to 1993 August, and covering most of the region viewed by the balloon instruments. We find no evidence for backscatter emission. Under the hypothesis that the source is 1E 1740.7-2942, the OSSE data set (186 days) disagrees with the balloon measurements with 99.3% confidence. The average daily 3 sigma OSSE upper limit on bakscatter flux from 1E 1740.7-2942 is 6.8 x 10(exp -4) photons/sq cm/s, compared to the 1.3 x 10(exp -3) photons/sq cm reported by the balloon observations. We also saw no evidence in 186 days for linelike emission from the point source EXS 1737.9-2952 recently discovered by Grindlay, Covault, & Manandhar (1993). This source exhibited bright emission from 83-111 keV, which has been interpreted as doubly backscattered 511 keV radiation. The average daily 3 sigma upper limit from OSSE for this line is 9.8 x 10(exp -4) photons/sq cm/s, or approximately 8% of the reported flux.
Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.
On two flights in 1988, the Gamma-Ray Imaging Spectrometer (GRIS) discovered the galactic center in a high state (greater than 1 x 10(exp -3) ph/(sq cm sec)) of positron annihilation line emission (511 keV) after nearly a decade of failed attempts to confirm the exciting early results of balloon and satellite instruments. These two flights represented the first flights of a new generation of high resolution germanium spectrometers designed to achieve significantly greater sensitivity for astrophysical observations. During the fall flight, an observation of the galactic plane at 335 degrees longitude was also performed. This observation showed a very low level of 511 keV emission (2 +/- 1 x 10(exp -4) ph/(sq cm sec)), confirming the galactic center origin of the line, and a high level of hard x-ray and gamma-ray continuum emission (1 x 10(exp -4) ph/(sq cm sec keV) at 100 keV), which we attribute to galactic diffuse emission. Improved fits to the spectrum of the galactic center are presented with the proposed diffuse component subtracted. We conclude that our galactic center continuum spectrum is consistent with the sum of the 1E1740.7-2942 spectrum observed by SIGMA/GRANAT and our 1 = 335 degree galactic plane spectrum. The predicted diffuse flux should be easily measurable by the Oriented Scintillation Spectrometer Experiment (OSSE) experiment on the Gamma Ray Observatory (GRO).
Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.
A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.
NaI scintillation spectrometer response function matrices semiautomatic generation, using standard source spectra to obtain normalized Compton continua
Trapped protons east-west asymmetry observations during Gemini 4 flight, using on-board high sensitivity plastic-scintillation spectrometer
Absolute cosmic-ray free air ionization and charged particle fluxes and dose rates throughout the atmosphere were measured on a series of balloon flights that commenced in 1968. Argon-filled ionization chambers equipped with solid-state electrometers, with different gas pressures and steel wall thicknesses, and a pair of aluminum-wall Gm counters have provided the basic data. These data are supplemented by measurements with air-filled and tissue equivalent ionization chambers and a scintillation spectrometer. Laboratory experiments together with analyses of the theoretical aspects of the detector responses to cosmic radiation indicate that these profiles can be determined to an overall accuracy of + or - 5 percent.
Data from a balloon flight experiment using an Na I scintillation spectrometer were analyzed for gamma ray pulsation. The payload was carried to a nominal atmospheric depth of 3.5 g/cm2. A superposed epoch analysis was performed on a 12,000 second portion of the data spanning a total time interval of 16,700 seconds at float altitude. A positive pulsed contribution was observed at the expected apparent frequency of NP 0532 having the typical double pulse structure. The results indicate a time-averaged pulse photon flux of 0.00144 + or - 0.00057 photons/sq cm/sec in the energy interval from 250 keV to 2.3 MeV. This represents a time-averaged pulsed power of 0.000649 + or - 0.000257 keV/sq cm/sec/keV. The ratio of interpulse to main pulse was found to be 2.4 + or - 1.9. The analysis indicates a positive photon flux from 250 keV to 725 keV of 0.00120 + or - 0.00052 photons/sq cm/sec.
Measurements of MeV neutron were made at the surface of a lithium hydride and depleted uranium shielded reactor. Four shield configurations were considered: these were assembled progressively with cylindrical shells of 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, 13-centimeter-thick lithium hydride, 5-centimeter-thick depleted uranium, and 3-centimeter-thick depleted uranium. Measurements were made with a NE-218 scintillation spectrometer; proton pulse height distributions were differentiated to obtain neutron spectra. Calculations were made using the two-dimensional discrete ordinates code DOT and ENDF/B (version 3) cross sections. Good agreement between measured and calculated spectral shape was observed. Absolute measured and calculated fluxes were within 50 percent of one another; observed discrepancies in absolute flux may be due to cross section errors.
The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.
The X-ray spectrum of the Crab Nebula was measured with the scintillation spectrometer on board the OSO-8 satellite. The total emission of the X-ray source shows no long term variability. The spectrum itself can be described by a single power law out to energies of at least 500 keV.
X-ray spectra of Cygnus XR-1 were measured with the scintillation spectrometer on board the OSO-8 satellite during a period of one and one-half to three weeks in each of the years from 1975 to 1977. Observations were made when the source was both in a high state and in a low state. Typical spectra of the source between 15 and 250 keV are presented. The observed pivoting effect is consistent with two temperature accretion disk models of the X-ray emitting region. No significant break in the spectrum occurred at energies up to 150 keV. The high state as defined in the 3 to 6 keV bandwidth was found to be the higher luminosity state of the X-ray source. One transition from a low to a high state occurred during observations. The time of occurrence of this and other transitions is consistent with the hypothesis that all intensity transitions occur near periastron of the binary system, and that such transitions are caused by changes in the mass transfer rate between the primary and the accretion disk around the secondary.
Results are reported for a measurement of the X-ray spectrum of the Crab Nebula over the energy range from 20 to 500 keV with a scintillation spectrometer aboard the OSO-8 satellite. A time-averaged spectrum of the nebula is presented which includes the average intensity of the X-ray pulsar NP 0532. The photon spectrum is shown to be well-fitted by a power law with a constant of approximately 4.19, a weighted mean energy of 39.1 keV, and a spectral index of about 2.00. No evidence is found for day-to-day variations in the spectrum of the source. The spectrum obtained is taken as evidence for the single power-law character of the Crab Nebula spectrum out to at least 200 keV and probably to as high an energy as 500 keV.
Her X-1 was observed from 1977 August 30 to September 10 using the High-Energy X-Ray Scintillation Spectrometer on board the OSO-8 satellite. The observation, during which the source was monitored continually for nearly an entire ON-state, covered the energy range from 16 to 280 keV. Pulsed flux measurements as a function of binary orbit and binary phase are presented for energies between 16 and 98 keV. The pulsed flux between 16 and 33 keV exhibited a sharp decrease following the fourth binary orbit and was consistent with zero pulsed flux thereafter. The pulsed spectrum was fitted with a power law, a thermal spectrum without features, and a thermal spectrum with a superposed gaussian centered at 55 keV. The latter fit has the smallest value of chi - squared per degree of freedom, and the resulting integrated line intensity is 1.5 superscript + 4.1 subscript - 1.4 x .001 photons s superscript-1 cm superscript-2 for a width of 3.1 superscript + 9.1 subscript -2.6 keV. This result, while of low statistical significance, agrees with the value observed by Trumper (1978) during the same On-state.