Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCRUBBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sample Results from the Next Generation Solvent Program Real Waste Extraction-Scrub-Strip Testing

Savannah River National Laboratory (SRNL) performed multiple Extraction-Scrub-Strip (ESS) testing using real waste solutions, and three Next Generation Solvent (NGS) variations, which included radiologically clean pure NGS, a blend of radiologically clean NGS and radiologically clean BOBCalixC6 (NGS-MCU), and a blend of radiologically clean NGS and radiologically contaminated BOBCalixC6 from the MCU Solvent system. The results from the tests indicate that both the NGS and the NGS-MCU blend exhibit adequate extraction, scrub and strip behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Static Irradiated ALSEP Scrub Section

The INL is studying the impacts of gamma radiolysis on the ALSEP minor actinide extraction process. This process uses an organic solvent consisting of a neutral diglycolamide extractant, N,N,N’,N’ -tetra-2- ethylhexylglycolamide (T2EHDGA), and an acidic extractant 2-ethylhexylphosphonic acid mono-2- ethylhexyl ester (HEH[EHP]) dissolved in an aliphatic diluent. The actinides and lanthanides are coextracted from relatively high nitric acid and the actinides are selectively stripped using a carboxylic acid buffered aminopolycarboxylic acid solution. Previous investigations of the radiolytic degradation processes on the ALSEP process performed at the INL focused upon the extraction section of the flowsheet. Current efforts are concerned with examining the scrub section of the ALSEP flowsheet. This report describes the static irradiations performed during the current fiscal year in support of the test loop irradiations which will be conducted later in FY-2017, and documents completion of the level four milestone (M4FT- 17IN030102012) entitled “Static Irradiated ALSEP Scrub Section.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Sample Tank 202

An Extraction, Scrub, and Strip (ESS) test was performed on a sample from Tank-202. The purpose of testing this sample is to determine if the solvent is displaying the correct extraction and stripping behavior with cesium. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 14.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Extraction-Scrub-Strip (ESS) Tests With Solvent Using IBC BOBCalix

Two Extraction, Scrub, and Strip (ESS) tests were performed on two BOBCalix solvent samples prepared using BOBCalix from IBC Advanced Technologies (“IBC”). The purpose of testing this sample is to confirm if the newly sourced BOBCalix displays the correct extraction and stripping behavior with cesium. The first batch of BOBCalix solvent was prepared using IBC lot#220310KC-1. The second batch was prepared using IBC lot#220615KC-3A. The ESS tests showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) values for the tests were 12.9 and 13.6. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios (0.0588/0.0342/0.0258 and 0.0575/0.0335/0.0262) fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Sodium Pool

Mechanistic source term (MST) analyses are likely to be an important part of advanced reactor licensing applications. For the purpose, an MST analysis code applicable to newly introduced advanced reactors, called SRT (Simplified Radionuclide Transport) code, has been developed by Argonne National Laboratory. SRT can track overall behaviors of radionuclides especially in metal fuel-based sodium fast reactors (SFRs) and microreactors. Throughout the simulation, migration inside fuel pins before failure, interaction with coolant (for SFR), removal/leakage in cover gas and containment (or confinement), and environmental dose impacts are considered alongside radioactive decay for short-lived nuclides. Among the postulated process, pool scrubbing phenomenon, especially under sodium pool condition, has been identified as high importance with limited supportive data. The phenomenon plays a crucial role in assessing the degree of radiological impacts as radioactive aerosols or vapors are efficiently and effectively removed during the process. To provide validation basis for SRT in assessing pool scrubbing performance inside sodium pools, the University of Wisconsin-Madison performed tests including extensive parametric effects. Separate effect tests were conducted to directly evaluate the SRT models and to estimate degree of contribution by each contributing factor. Specifically, bubble size, aerosol size, aerosol density, aerosol concentration, pool depth, system temperature, and bubble swarm effects were considered. According to the parametric effects, decontamination performance enhances with decreasing bubble size, large density, and deeper pool height. Aerosol concentration provides no effect for the whole range of interest, and pool temperature variation shows minor effects under the considered temperature condition. When multiple bubbles are injected generating a bubble swarm condition, DF performance further enhances by bubble interactions and turbulence characteristics. The measurement shows the exceptional importance of aerosol size range considered, with the lowest decontamination, where most radionuclides are expected to escape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emission control system for nitrogen oxides using enhanced oxidation, scrubbing, and biofiltration

Nitric oxide (NO) constitutes about 90% of the nitrogen oxide (NOx) species in the flue gases emitted from combustion processes, but NO is difficult to remove in existing scrubbers due to its low solubility. NO may be oxidized with hydrogen peroxide (H{sub 2}O{sub 2}) into soluble species that can be partially removed in wet scrubbers simultaneously with sulfur dioxide (SO{sub 2}) and biofilters located downstream of the scrubber can increase the removal efficiency. This article presents the results of a bench-scale evaluation of such an integrated system combining enhanced oxidation, scrubbing, and biofiltration. Main components of the bench-scale system consisted of a quartz tube in a furnace to simulate the NO oxidation stage and two vertical packed bed cylinders constituting the scrubber and the biofilter. Inlet synthetic gas had a concentration of 50 mu L/L of NO. Overall removal efficiency by the integrated system was in the range of 53% to 93% with an average of 79%, absorption accounted for 43% and biofiltration for 36% of the total removal. Key parameters in the operation of the system are the H{sub 2}O{sub 2}:NO mole ratio, the reaction temperature, the liquid to gas flow ratio, and the biofilter residence time. Experimental results suggest a path for optimization of the technology focusing simultaneously in minimizing H{sub 2}O{sub 2} use in the enhanced oxidation stage, reducing water consumption in the scrubber stage and balancing the residence times in the three stages of the integrated system.

01 COAL, LIGNITE, AND PEAT↗

Amine Scrubbing for CO{sub 2} Capture

Amine scrubbing has been used to separate carbon dioxide (CO{sub 2}) from natural gas and hydrogen since 1930. It is a robust technology and is ready to be tested and used on a larger scale for CO{sub 2} capture from coal-fired power plants. The minimum work requirement to separate CO{sub 2} from coal-fired flue gas and compress CO{sub 2} to 150 bar is 0.11 megawatt-hours per metric ton of CO{sub 2}. Process and solvent improvements should reduce the energy consumption to 0.2 megawatt-hour per ton of CO{sub 2}. Other advanced technologies will not provide energy-efficient or timely solutions to CO{sub 2} emission from conventional coal-fired power plants.

01 COAL, LIGNITE, AND PEAT↗

Extraction-Scrub-Strip test results from the interim Salt Disposition Program Macrobatch 9 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs) ) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of an ammonia-based wet scrubbing process in a continuous flow system

A continuous gas and liquid flow, regenerative scrubbing process for CO{sub 2} capture was demonstrated at the bench-scale level. An aqueous ammonia-based solution captures CO{sub 2} from simulated flue gas in an absorber and releases a nearly pure stream of CO{sub 2} in the regenerator. After the regeneration, the solution of ammonium compounds is recycled to the absorber. The design of a continuous flow unit was based on earlier exploratory results from a semi-batch reactor, where a CO{sub 2} and N{sub 2} simulated flue gas mixture flowed through a well-mixed batch of ammonia-based solution. During the semi-batch tests, the solution was cycled between absorption and regeneration steps to measure the carrying capacity of the solution at various initial ammonia concentrations and temperatures. Consequentially, a series of tests were conducted on the continuous unit to observe the effect of various parameters on CO{sub 2} removal efficiency and regenerator effectiveness within the flow system. The parameters that were studied included absorber temperature, regenerator temperature, initial NH{sub 3} concentration, simulated flue gas flow rate, liquid solvent inventory in the flow system, and height of the packed-bed absorber. From this testing and subsequent testing, ammonia losses from both the absorption and regeneration steps were quantified, and attempts were made to maintain steady state during operations. Implications of experimental results with respect to process design are discussed.

54 ENVIRONMENTAL SCIENCES↗

A deubiquitylase with an unusually high-affinity ubiquitin-binding domain from the scrub typhus pathogen Orientia tsutsugamushi

Ubiquitin mediated signaling contributes critically to host cell defenses during pathogen infection. Many pathogens manipulate the ubiquitin system to evade these defenses. Here we characterize a likely effector protein bearing a deubiquitylase (DUB) domain from the obligate intracellular bacterium Orientia tsutsugamushi, the causative agent of scrub typhus. The Ulp1-like DUB prefers ubiquitin substrates over ubiquitin-like proteins and efficiently cleaves polyubiquitin chains of three or more ubiquitins. The co-crystal structure of the DUB (OtDUB) domain with ubiquitin revealed three bound ubiquitins: one engages the S1 site, the second binds an S2 site contributing to chain specificity and the third binds a unique ubiquitin-binding domain (UBD). The UBD modulates OtDUB activity, undergoes a pronounced structural transition upon binding ubiquitin, and binds monoubiquitin with an unprecedented ~5 nM dissociation constant. The characterization and high-resolution structure determination of this enzyme should aid in its development as a drug target to counter Orientia infections.

59 BASIC BIOLOGICAL SCIENCES↗

Reassessment of caustic scrubbing for radioiodine capture during UNF processing

The effective removal of iodine-129 from gaseous emissions during used nuclear fuel processing is critical for minimizing environmental contamination and ensuring environmental regulatory compliance. Recent research has focused on optimizing process air, scrubber conditions, and integrating complementary techniques, such as solid sorbents as a polishing step, to improve iodine capture efficiency. The efficiency of a caustic scrubber is influenced by several factors, such as pH, temperature, gas–liquid contact time, and the presence of oxidants, yet the existing literature tends not to consider how these factors might interact or change in importance with process scaling. This perspective advocates for reconsidering how to mitigate many of these factors, especially in view of the transition from laboratory bench to pilot scale and beyond. This paper reviews the principles, operational parameters, and advancements in caustic aqueous scrubbing for radioiodine mitigation, aims to direct the next scientific pursuit of this technology, and inform environmental decision-making.

Ngelale, Randy [Oak Ridge National Laboratory (ORN↗

Thermal degradation of the solvent employed in the next-generation caustic-side solvent extraction process and its effect on the extraction, scrubbing, and stripping of cesium

As part of the ongoing development of the Next-Generation Caustic-Side Solvent Extraction (NGS) process, the thermal stability of the process solvent was investigated and shown to be adequate for industrial application. The solvent was thermally treated at 35 C over a period of 13 months whilst in dynamic contact with each of the aqueous phases of the current NGS process, namely SRS 15 (a highly caustic waste simulant), sodium hydroxide scrub solution (0.025 M), and boric acid strip solution (0.01 M). The effect of thermal treatment was evaluated by assessing batch extract/scrub/strip performance as a function of time, by monitoring the sodium extraction capacity of the solvent, and by analysis of the solvent using electrospray mass spectrometry. Current studies indicate that the NGS solvent should be thermally robust for a period of XXX months at the Modular Caustic-Side Solvent Extraction Unit (MCU) pilot plant located at Savannah River Site. Furthermore, the guanidine suppressor appears to be the solvent component most significantly impacted by thermal treatment of the solvent, showing significant degradation over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The effects of 11 years of CO2 enrichment on roots in a Florida scrub-oak ecosystem

Uncertainty surrounds belowground plant responses to rising atmospheric CO2 because roots are difficult to measure, requiring frequent monitoring as a result of fine root dynamics and long-term monitoring as a result of sensitivity to resource availability. We report belowground plant responses of a scrub-oak ecosystem in Florida exposed to 11 yr of elevated atmospheric CO2 using open-top chambers. We measured fine root production, turnover and biomass using minirhizotrons, coarse root biomass using ground penetrating radar and total root biomass using soil cores. Total root biomass was greater in elevated than in ambient plots, and the absolute difference was larger than the difference aboveground. Fine root biomass fluctuated by more than a factor of two, with no unidirectional temporal trend, whereas leaf biomass accumulated monotonically. Strong increases in fine root biomass with elevated CO2 occurred after fire and hurricane disturbance. Leaf biomass also exhibited stronger responses following hurricanes. Responses after fire and hurricanes suggest that disturbance promotes the growth responses of plants to elevated CO2. Increased resource availability associated with disturbance (nutrients, water, space) may facilitate greater responses of roots to elevated CO2. The disappearance of responses in fine roots suggests limits on the capacity of root systems to respond to CO2 enrichment.

54 ENVIRONMENTAL SCIENCES↗

Synthesis of scrub-oak responses to elevated CO 2

This report summarizes a synthesis project of a long-term global change experiment conducted at the Kennedy Space Center, Florida, investigating how increasing concentrations of atmospheric carbon dioxide (CO 2 ) influences the functioning of a fire-dominated scrub-oak ecosystem. The experiment began in 1996 and ended in 2007. Results presented here summarize the effects of elevated CO 2 on plant growth, soil processes, carbon and nutrient cycling, and other responses. Products include archived data from the experiment, as well as six publications in the peer-reviewed literature.

54 ENVIRONMENTAL SCIENCES↗

Extraction, -scrub, -strip test results from the interim salt disposition program macrobatch 10 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extraction, Scrub, and Strip Test Results from The Interim Salt Disposition Program Macrobatch 11 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 11 for the Interim Salt Disposition Program (ISDP). The Salt Batch 11 characterization results were previously reported. An Extraction, Scrub, and Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the Next Generation Solvent (NGS) Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 117. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This cesium removal efficiency is better than the predicted value of 50.8 from a recently created D (Cs) model.

Peters, T.↗

Extraction, Scrub, and Strip Test Results for the IBC BOBCalix Solvent Samples

A second vendor for solvent extraction components has been chosen for use at the Salt Waste Processing Facility (SWPF). IBC Advanced Technologies (IBC) has provided samples of their BOBCalix, as well as complete solvent. These samples were tested for quality assurance purposes to ensure their use at SWPF is acceptable. Two Extraction, Scrub, and Strip (ESS) tests were performed on solvent samples from IBC. The purpose of testing these samples was to determine if the solvents are displaying the correct extraction and stripping behavior with cesium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗