Search NASA⌕ Search

SEARCH · Search NASA

Results for “SEALING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

Preparation of a membrane-sealed cell for studying catalyst nanoparticles in flowing gas with high vacuum x-ray photoelectron spectrometer

Here a sealing-style x-ray photoelectron spectroscopy study of the surface of a 1.0 wt. %Ni/TiO2 nanoparticle catalyst in a flowing mixture of CO and O2 at 1 bar was performed with a graphene membrane-sealed Si3N4 window-based miniature cell. We report the details on how a commercial Si3N4 window is modified before assembling a graphene membrane, how single-layer graphene membranes are transferred from their metal supports to the modified Si3N4 window, how a modified Si3N4 window covered with a double-layer graphene membrane is assembled onto a blank cell cap, how a nanoparticle catalyst is introduced to the cell cap and then the cell cap is installed onto a cell body to form a complete reaction cell, and how a complete cell is interfaced with a high vacuum chamber of an XPS system before an XPS study of 1.0 wt. %Ni/TiO2 catalyst surface in a flowing mixture for 0.2 bar CO and 0.8 bar O2 is performed. How the characterization of a catalyst using this type of graphene membrane-sealed Si3N4 window-based miniature cell is relevant to the finding of the actual surface chemistry of a catalyst during catalysis is discussed.

Instruments & Instrumentation↗

Testing and Expertise for Marine Energy (TEAMER) Program Support: MRE Dynamic Seals Performance Investigation (CRADA Final Report)

This TEAMER project allows NREL to use and augment a custom special-purpose testing system to perform accelerated-life testing of rotating seals for use in the Marine Renewable Energy (“MRE”) industry. The requirements of this industry are different from most applications including marine, and relevant performance information is lacking. In order to achieve low costs with extremely effective and reliable operation over long periods deployed underwater, more study of the best seals and arrangements of seals must be performed. By developing a rigorous framework for such testing, NREL hopes to greatly improve understanding of the relevant factors and provide significant data to the industry. Further, this work can inform standards developments for this critical component of MRE systems, leading to maturation and improved acceptance of the industry in commerce.

16 TIDAL AND WAVE POWER↗

Evaluation of Lost Circulation Material Sealing for Geothermal Drilling

Lost circulation is a pervasive problem in geothermal wells that can create prohibitive costs during drilling. The main issue with treatment is that the mechanism of plug formation is poorly understood. Here we applied two experimental approaches to characterize the clogging effectiveness of different materials. Fracture flow tests with different geometries were conducted with various individual materials and mixtures at relevant conditions. A high-temperature flow loop system was also developed to inject single- and mixed-material plugs into a gravel pack with a non-uniform geometry to compare with the fracture tests. The fracture tests revealed that single materials tended to form no plug or an unstable plug, while mixtures of materials were uniformly better at sealing fractures. Gravel pack tests at high temperatures show most of the materials are intact but degraded. The fibrous materials can create partial or unstable plugs in the gravel pack, but mixed-material plugs are far more effective at clogging. Both test types suggest that (1) mixed materials are more effective at blocking fluid flow and (2) fibrous materials seal fracture openings better, while granular materials seal inside fractures or pore throats better. Further research is needed to study the long-term stability of different plug configurations.

clogging tests↗

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

Financial Exposure After a Sealed-Source Release: Insurance Limits, Federal Cost Pathways, and Implications for Gamma Irradiator Substitution

This report assesses whether private insurance and existing federal authorities would likely provide meaningful financial protection to private operators of self-shielded gamma irradiators after a major sealed-source release. It does not answer this question quantitatively because publicly observable data on premiums, limits, uptake, and claims outcomes for this risk class appear sparse. Instead, it uses a qualitative structural analysis based on prior literature, review of relevant federal authorities, limited observable insurance-market evidence, expert outreach, and historical analogs. The analysis finds that available public and private mechanisms do not combine into a clear, dependable, or readily verifiable compensation structure for ordinary private sealed-source operators. Institutions therefore should not assume that either insurance or government response will make them financially whole after a severe incident. Source reduction and replacement remain more dependable than post-event financial mechanisms for reducing institutional exposure and broader radiological risk.

99 GENERAL AND MISCELLANEOUS↗

On Caprock Seal Integrity of Tuscaloosa Mudstone at Cranfield, MS (USA), CO 2 Injection Site

Saline formations deep underground are among the most promising targets for large-scale geologic carbon storage. The caprock seal integrity evaluation is an important component of commercial-scale CO 2 sequestration projects. Measurements of the porosity and permeability of mudstone samples from the NETL-supported Cranfield Project were performed using a helium porosimeter and a core flow apparatus, before and after exposure in a CO 2 -saturated brine environment. The permeability of the core samples rapidly decreased with the increase in confining pressure and did not fully recover after decompression. On the other hand, exposure to CO 2 led to an increase in the permeability by at least an order of magnitude. The porosity changes after the exposure were not substantial. The post-exposure increase in permeability was subsequently offset by its rapid decrease during the higher-pressure confinement. Extrapolation of the observed permeability trends to in situ reservoir conditions suggests that Tuscaloosa mudstone can effectively serve as a natural seal.

58 GEOSCIENCES↗

Vacuum insulated glazing, valve, flexible seal, and method for making vacuum insulated glazing

A vacuum insulated glazing includes first and second spaced apart glass panes having perimeter portions defining a vacuum space between the glass panes. A vacuum valve is positioned at the perimeter portions of the glass panes and includes a valve body extending between the perimeter portions of the glass panes, and having first and second ends and a fluid conduit extending from the first end to the second end of the valve body and in fluid communication with the vacuum space. A one-way valve in the fluid conduit permits fluid flow from the vacuum space, and prevents fluid flow into the vacuum space. A suction fitting is provided for connecting the valve body to a suction device. An end seal between the perimeter portions of the glass panes is provided for hermetically sealing the vacuum space. A valve for a VIG and a method of making a VIG are also disclosed.

Bhandari, Mahabir↗

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS↗

A Mobile Hot Cell for Conditioning Disused Sealed Radioactive Sources for Storage or Transportation

An innovative Mobile Hot Cell (MHC) has been developed for conditioning Disused Sealed Radioactive Sources (DSRS) category 1 and 2 for storage or transportation. The MHC is designed to provide both Radiological and Biological containment with a maximum capacity of 1000 Ci Co60 or 5000Ci Cs137 source and can be transported via standard cargo containers. This project has been supported through the National Nuclear Safety Administration (NNSA) Offsite Source Recovery Program (OSRP). The project is intended for the international community rather than domestic although domestic use is a possibility. Many countries have significant stockpiles of these devices that are often stored in less-than-optimal circumstances. This necessitates that these devices be addressed expeditiously, and the sources secured. The MHC utilizes robotics, automation, and other non-traditional methods for disassembling, characterizing, and packaging these sources that have reached end of life or are otherwise not needed. These innovative approaches are necessary to facilitate an expedited timeline to efficiently and safely secure these sources in a non-proliferation effort. Conditioning efforts include disassembling the device such as a teletherapy head used for cancer treatment, or blood/research irradiators such that the radioactive sources may be removed safely. The sources are then characterized. Leak checks are performed, dimensions are verified, and serial numbers are confirmed. Upon completion, the sources are typically placed into a Standard Forms Capsule which is seal welded closed. It is leak tested and placed into a Long-Term Storage Shield (LTSS) which can either be secured for storage directly or loaded into an appropriate cask for transportation. Further innovations include multiple deployment scenarios that include a full deployment of MHC components, deployment of the MHC automation internal components to an existing hot cell, deployment of minimally required MHC components and incorporation of sand for shielding, and integration of the MHC for Silo Storage, or Bore Hole Storage efforts. The MHC has evolved from a very specific use case to a “Swiss Army Knife” type of a tool in that it can be readily adapted to a large variety of situations. Innovative approaches such as the use of robotics, Computer Numeric Control (CNC) machining centers, automated welding equipment, HDMI Cameras, and LED lighting are some of the developed technologies incorporated into the MHC design. Shielding is accomplished with a steel walled Base Box which is surrounded by four nesting doll shield shells which when combined limits the external dose rate to 5mr/hr when a 1000 Ci Co60 source is exposed inside.

99 - GENERAL AND MISCELLANEOUS↗

ResStock Measure Documentation: Advanced Air Sealing With Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Air Sealing With Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Duct Sealing and Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPC-71188 Rev 0 MARVEL Control Drum Rotary Shaft Seal Procurement Specification

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of the MARVEL Control Drum Rotary Shaft Seal.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

ECAR-7813 Rev 0 Secondary Coolant Cover Gas System Stirling Engine Tube Rupture Analysis, Insulation Block Analysis, and Labyrinth Seal Design

The purpose of this ECAR is to document compliance with best engineering practices for the Secondary Coolant Cover Gas System of the MARVEL microreactor which includes a Stirling Engine helium tube rupture analysis, an analysis to verify the strength of the insulation blocks, and the design of the Labyrinth Seal.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗