The Role of Water on the Interfacial Adhesion in Si Solar Modules

Delamination of solar module interfaces often occurs in field-tested solar modules after decades of service due to environmental stressors such as humidity. As water diffuses into the module, failure mechanisms like corrosion and delamination are significantly affected. In the presence of water, the interfaces between EVA and the cell, glass, and backsheet all experience losses of adhesion exposing the module to accelerated degradation. Understanding the relation between interfacial adhesion and water content inside PV modules can help mitigate detrimental power losses. Water content measurements via short wave infrared reflectometry combined with 180 degrees peel tests were used to study and quantify the effect of water ingress and egress on adhesion. Changes in adhesion strength for different module interfaces are quantified, correlating spatial distribution of water content to adhesion for damp heat and dry heat exposed samples. After 1000 hours of damp heat exposure, decreases in adhesion strength of approximately 1 N/mm were noted for all interfaces.

adhesion↗

Prototype Laboratory Concept

The prototype laboratory concept was developed to simplify the laboratory design process, and should be considered for use as a new laboratory design methodology. Many developing countries lack adequate public and animal health laboratories and typically do not have the economic means and the design and construction expertise to build a laboratory on their own. These countries rely on international sponsors to provide the funds necessary to design and construct a laboratory. However, these international sponsors are often located far away, making travel back and forth difficult, which leads to an increase in overall costs and delays for the project. The prototype laboratory concept and design methodology were developed to streamline the design process, saving time and money, while also minimizing the number of errors that typically arise using a traditional design process by providing well considered design decisions in advance of the project. By solving numerous detailed design issues early, this methodology will allow the time, attention and energies of the design team to be focused on addressing the specific needs of the end users, the unique design challenges related to a given site and scientific program, and the biosafety and biosecurity risks associated with the scientific activities planned to be conducted in the facility. While the concept could be expanded to cover other types of laboratories to date, it has primarily focused on supporting the implementation of good laboratory design best practices for infectious disease diagnostic and research laboratories for both the human and animal health sectors. This report presents the laboratory design concept and details associated with the modular layouts. It builds on the work previously provided in the interim prototype laboratory concept report delivered to the Cooperative Biological Engagement Program (CBEP) at the Defense Threat Reduction Agency (DTRA) in 2014. This report includes a number of revised and additional module layouts, more detailed information regarding laboratory finishes and equipment, engineering service information, electrical and lighting layouts, plumbing service information and two mechanical service options for each prototype module. Additionally, this report also includes a description of a cost estimating tool that will accompany this report and allow funding agencies to generate an approximate cost for the construction of a laboratory that utilizes the prototype laboratory concept modules. This report is intended to serve a complete document and includes all relevant information from the 2014 prototype laboratory concept report.

42 ENGINEERING↗

DuraMAT: Building a Consortium to Accelerate the Photovoltaic Module Reliability Learning Cycle

Durable and reliable photovoltaic (PV) modules are critical to enabling an efficient transition to sustainable energy generation. The rate at which new module designs and materials are developed and deployed currently outpaces the rate at which we can identify failure mechanisms and understand degradation rates. Increasing the service life of PV modules, and our ability to predict performance over time, requires more durable materials and designs, better durability testing, more extensive material characterization, robust modeling, and methods to cross-examine historical performance data to extract meaningful results. This is a multidisciplinary challenge that requires expertise from a broad range of fields and, therefore, benefits significantly from a collaborative approach. In this Perspective, we outline the approach taken by the Durable Module Materials Consortium (DuraMAT), present a few case studies where our approach was successful, and provide an outlook on where this approach might be applied as the PV technology landscape continues to rapidly evolve. Published by the American Physical Society 2024

14 SOLAR ENERGY↗

SU-F-T-139: Meeting the Challenges of Quality Control in the TOPAS Monte Carlo Simulation Toolkit for Proton Therapy

Purpose: Monte Carlo particle transport simulation (MC) codes have become important tools in proton therapy and biology, both for research and practice. TOPAS is an MC toolkit serving users worldwide (213 licensed users at 95 institutions in 21 countries). It provides unprecedented ease in 4D placement of geometry components, beam sources and scoring through its user-friendly and reproducible parameter file interface. Quality control (QC) of stochastic simulation software is inherently difficult, and the versatility of TOPAS introduces additional challenges. But QC is vital as the TOPAS development team implements new features, addresses user feedback and reacts to upgrades of underlying software (i.e. Geant4). Methods: Whenever code is committed to our repository, over 50 separate module tests are automatically triggered via a continuous integration service. They check that the various module options execute successfully and that their results are statistically consistent with previous reference values. Prior to each software release, longer end-to-end tests automatically validate TOPAS against experimental data and a TOPAS benchmark. These include simulating multiple properties of spread-out Bragg peaks, validating nuclear models, and searching for differences in patient simulations. Results: Continuous integration has proven effective in catching regressions at the time they are introduced, particularly when implementing new features that involve refactoring code (e.g. multithreading and ntuple output). Code coverage statistics highlight untested portions of code and guide development of new tests. The various end-to-end tests demonstrate that TOPAS accurately describes the physics of proton therapy within clinical tolerances. Conclusion: The TOPAS QC strategy of frequent short tests and pre-release long tests has led to a more reliable tool. However, the versatility of TOPAS makes it difficult to predict how users might combine different modules, and so QC ultimately remains a partnership between the developer and the user. This work was funded by National Cancer Institute grant R01 CA 140735.

60 APPLIED LIFE SCIENCES↗

Quantifying Reliability - The Next Step for a Rapidly Maturing PV Industry and China's Role

PV customers wish to know how long their PV modules will last, but quantitatively predicting service life is difficult because of the large number of ways that a module can fail, the variability of the use environment, the cost of the testing, and the short product development time, especially when compared with the long desired lifetime. China should play a key role in developing international standards because China manufactures most of the world's PV modules. The presentation will describe the steps that need to be taken to create a service life prediction within the context of a defined bill of materials, process window and use environment. Worldwide standards for cost-effective approaches to service-life predictions will be beneficial to both PV customers and manufacturers since the consequences of premature module failure can be disastrous for both.

14 SOLAR ENERGY↗

Durability of ionomer encapsulants in photovoltaic modules

Ethylene vinyl acetate (EVA) has for decades been the preferred material for photovoltaic (PV) module encapsulation. However, while it is relatively inexpensive and initially adheres well to module components, EVA discolors with age and - as interfacial adhesion degrades - becomes susceptible to delamination, ultimately resulting in reduced module efficiency and shortened service lifetimes. As potential replacements for EVA, ionomer thermoplastic materials cure faster, are more resistant to discoloration and potential induced degradation, and do not evolve corrosive acetic acid, making them compatible with new device materials such as perovskites. Since there is limited information on ionomer durability for PV module applications, a series of field and accelerated laboratory aging studies were conducted to assess ionomer interface stability in the presence of terrestrial environmental stressors. It is shown that adhesion to the glass and cell interfaces of PV modules is inferior to EVA, both before and after aging, rendering ionomers particularly susceptible to delamination after short timeframes. Potential solutions to improve ionomer adhesion are discussed.

14 SOLAR ENERGY↗

Gas Ingress and Egress of MEMS Multi-Chip Modules and MEMS Devices

Hermetic microcircuit packaging was the dominant method of protecting semiconductor devices in the 1960s and 1970s. After losing majority market sectors to plastic encapsulated microelectronics over the last a few decades, hermetic packaging remains the preferred method of protecting semiconductor devices for critical applications such as in military, space, and medical fields, where components and systems are required to serve for several decades. MEMS devices impose additional challenges to packaging by requiring specific internal cavity pressures to function properly or deliver the needed quality (Q) factors. In MEMS multichip modules, internal pressure requirement conflicts arise when different MEMS devices require different internal gases and pressures. The authors developed a closed-formed equation to model pressure changes of hermetic enclosures due to gas ingression. This article expands the authors mathematical model to calculate gas pressure of a MEMS multichip module package as well as those of MEMS devices inside the multichip module package. These equations are not only capable of calculating service lifetimes of MEMS devices and multi-chip modules but can also help develop MEMS device packaging strategies to extend the service life of MEMS multi-chip modules.

36 MATERIALS SCIENCE↗

Degradation in photovoltaic encapsulant transmittance: Results of the first PVQAT TG5 artificial weathering study

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation is frequently identified as a cause of decreased performance through the service life of photovoltaic modules. However, the present module safety and qualification standards apply short UV doses, only capable of examining design robustness and 'infant mortality' failures. Furthermore, essential information remains unknown that might be used to screen encapsulants through product lifetime. We conducted an interlaboratory study to provide the understanding that will be used toward developing a higher-fidelity, more-rigorous UV weathering test. Five representative known formulations of poly (ethylene-co-vinyl acetate) were studied, in addition to one thermoplastic polyurethane material. Replicate laminated silica/polymer/silica specimens were examined at seven institutions using a variety of indoor chambers (including xenon, UVA-340, and metal-halide light sources). Specimens were artificially weathered for 180 cumulative days at steady-state accelerated test conditions, predesignated relative to the default irradiance of 1.0 W m-2 nm-1 at 340 nm, chamber temperature of 60 degrees C, and chamber relative humidity of 30%. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength - each determined from the measured hemispherical transmittance - are examined to provide understanding and guidance for the UV light source (type lamp and filters), temperature, and humidity used in accelerated UV aging tests. The relative efficacy of xenon-arc and UVA-340 fluorescent sources and the typical range of activation energy for degradation is quantified from the experiments.

14 SOLAR ENERGY↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

An end of service life assessment of PMMA lenses from veteran concentrator photovoltaic systems

The optical performance of poly(methyl methacrylate) lenses from veteran concentrator photovoltaic modules was examined after the end of their service life. Lenses from the Martin-Marietta and Intersol module designs were examined from the 'Solar Village' site near Riyadh, Saudi Arabia, as well as the Phoenix Sky Harbor airport, followed by the Arizona Public Service Solar Test and Research (APS-STaR) center in Tempe, Arizona. The various lens specimens were deployed for 20, 27, and 22 years, respectively. Optical characterizations included lens efficiency (Solar Simulator instrument), material transmittance and haze (of coupons cut from veteran lenses, then measured again after their faceted back surface was polished, and then measured again after the incident front surface was polished), and direct transmittance (as a function of detector's acceptance angle, using the Very Low Angular Beam Spread ('VLABS') instrument). Lens efficiency measurements compared the central region to the entire lens, also using hot and cold mirror measurements to diagnose differences in performance. A series of subsequent characterizations was performed because a decrease in performance of greater than 10% was observed for some of the veteran lenses. The optimal focal distance of the lenses was quantified using the Solar Simulator, and then correlated to lens curvature using a recently developed measurement technique. Surface roughness was examined using atomic force microscopy and scanning electron microscopy. Facet geometry (tip and valley radius) was quantified on cross-sectioned specimens. As a result, molecular weight was compared between the incident and faceted surfaces of the lenses.

14 SOLAR ENERGY↗

Air-Source Integrated Heat Pump System Development – Final Report

Between October 2007 and September 2017, Oak Ridge National Laboratory (ORNL) and Lennox Industries, Inc. (Lennox) engaged in a Cooperative Research and Development Agreement (CRADA) to develop an air-source integrated heat pump (AS-IHP) system for the US residential market. The Lennox AS-IHP concept consisted of a high-efficiency air-source heat pump (ASHP) for space heating and cooling services and a separate heat pump water heater/dehumidifier (WH/DH) module for domestic water heating and dehumidification (DH) services. A key feature of this system approach with the separate WH/DH is capability to pretreat (i.e., dehumidify) ventilation air and dedicated whole-house DH independent of the ASHP. Two generations of laboratory prototype WH/DH units were designed, fabricated, and lab tested. Performance maps for the system were developed using the latest research version of the US Department of Energy/ORNL heat pump design model (Rice 1992; Rice and Jackson 2005; Shen et al. 2012) as calibrated against the lab test data. These maps served as the input to TRNSYS (Solar Energy Laboratory et al. 2010) to predict annual performance relative to a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (i.e., a combination of an ASHP with a seasonal energy efficiency ratio (SEER) of 13 and resistance water heater with an energy factor (EF) of 0.9). Predicted total annual energy savings (based on use of a two-speed ASHP and the second-generation WH/DH prototype for the AS-IHP), while providing space conditioning, water heating, and dehumidification for a tight, well-insulated 2600 ft2 (242 m2) house at three US locations, ranged from 33 to 36%, averaging 35%, relative to the baseline system. The lowest savings were seen at the cold-climate Chicago location. Predicted energy use for water heating was reduced by about 50 to 60% relative to a resistance WH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal and Electrical Effects of Partial Shade in Monolithic Thin-Film Photovoltaic Modules: Preprint

Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature and current density compared to masks covering entire cells.

14 SOLAR ENERGY↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

Combined Spatially Resolved Characterization of Antireflection and Antisoiling Coatings for PV Module Glass

Characterization of photovoltaic (PV) module materials throughout different stages of service life is crucial to understanding and improving the durability of these materials. Currently the large-scale of PV modules (>1 m 2 ) is imbalanced with the small-scale of most materials characterization tools (= 1 cm 2 ). Furthermore, understanding degradation mechanisms often requires a combination of multiple characterization techniques. Here, we present adaptations of three standard materials characterization techniques to enable mapping characterization over moderate sample areas (=25 cm 2 ). Contact angle, ellipsometry, and UV-Vis spectroscopy are each adapted and demonstrated on two representative samples: a commercial multi-functional coating for PV glass and an oxide combinatorial sample library. Best practices are discussed for adapting characterization techniques for large area mapping and combining mapping information from multiple techniques.

14 SOLAR ENERGY↗

Photovoltaic (PV) Module Technologies: 2020 Benchmark Costs and Technology Evolution Framework Results

This report benchmarks 2020 PV module minimum sustainable price (MSP) via bottom-up manufacturing cost analysis, for established PV technologies in mass production, including crystalline silicon, cadmium telluride (CdTe), and copper indium gallium (di)selenide. We provide technology roadmaps to additional MSP reductions for these PV technologies. Separately, we consider III-V and perovskite PV technologies which are currently in small-scale or pilot production. Finally, this report uses a technology evolution framework (TEF) to analyze drivers of levelized cost of energy reductions, including installed system cost - which is heavily influenced by module price - as well as service life and annual energy yield.

14 SOLAR ENERGY↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DYnamic and Asynchronous Data Streamliner

DYAD aims to help sharing data files between producer and consumer job elements, especially between co-scheduled jobs or within an ensemble. DYAD provides the service by two components: a FLUX module and a I/O wraper set. DYAD transparently synchronizes file I/O between producer and consumer, and transfers data from the producer location to the consumer location managed by the service. Users only need to use the file path that is under the directory managed by the service.

Ahn, DongH↗

Mochi: Composing Data Services for High-Performance Computing Environments

Technology enhancements and the growing breadth of application workflows running on high-performance computing (HPC) platforms drive the development of new data services that provide high performance on these new platforms, provide capable and productive interfaces and abstractions for a variety of applications, and are readily adapted when new technologies are deployed. The Mochi framework enables composition of specialized distributed data services from a collection of connectable modules and subservices. Rather than forcing all applications to use a one-size-fits-all data staging and I/O software configuration, Mochi allows each application to use a data service specialized to its needs and access patterns. This paper introduces the Mochi framework and methodology. The Mochi core components and microservices are described. Examples of the application of the Mochi methodology to the development of four specialized services are detailed. Finally, a performance evaluation of a Mochi core component, a Mochi microservice, and a composed service providing an object model is performed. The paper concludes by positioning Mochi relative to related work in the HPC space and indicating directions for future work.

97 MATHEMATICS AND COMPUTING↗