Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Microwave cavity light shining through a wall optimization and experiment

It has been proposed that microwave cavities can be used in a photon regeneration experiment to search for hidden sector photons. Using two isolated cavities, the presence of hidden sector photons could be inferred from a ''light shining through a wall'' phenomenon. The sensitivity of the experiment has strong a dependence on the geometric construction and electromagnetic mode properties of the two cavities. In this paper we perform an in-depth investigation to determine the optimal setup for such an experiment. We also describe the results of our first microwave cavity experiment to search for hidden sector photons. The experiment consisted of two cylindrical copper cavities stacked axially inside a single vacuum chamber. At a hidden sector photon mass of 37.78 {mu}eV we place an upper limit on the kinetic mixing parameter {chi}=2.9x10{sup -5}. Whilst this result lies within already established limits our experiment validates the microwave cavity ''light shining through a wall'' concept. We also show that the experiment has great scope for improvement, potentially able to reduce the current upper limit on the mixing parameter {chi} by several orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Documenting Dual-Column Experiment with Mini-SHINE Solution

Argonne National Laboratory (Argonne) is assisting SHINE Medical Technologies (SHINE) in developing a production method and recovery and purification processes for molybdenum 99 (Mo-99) using an accelerator-driven, subcritical target consisting of an aqueous uranyl-sulfate solution. An integral part of the process is the development of a column for the separation and recovery of Mo-99, followed by a concentration column to reduce the product volume from 15–25 L to <1 L prior to entry into the low-enriched uranium (LEU)-Modified Cintichem purification process. Argonne has developed plant-scale column designs for the initial Mo-recovery column and the concentration column.

Stepinski, Dominique C.↗

FY-12 Results of Phase-1 Mini-SHINE/MIPS Experiments

This report describes Fiscal Year 2012 (FY-12) results for the first part of the phase 1 mini-SHINE/Medical Isotope Production System (MIPS) experiments, water irradiation. Water irradiation experiments were implemented to shake down/test equipment that will be used in the mini-SHINE/MIPS experiment with uranyl-salt solutions without the potential hazard of producing radioactive solutions and gases.

Chemerisov, Sergey↗

Letter Report: UREX Flowsheet for Cleanup of a Spent 130 g-U/L Uranyl Sulfate SHINE Target Solution

On July 6, 2011, Argonne sent two UREX flowsheets to Morgridge Institute for Research (MIR) for processing a 150 and 300 g-U/L solution of uranyl nitrate. Argonne was tasked by the National Nuclear Security Agency (NNSA) in Fiscal Year 2012 (FY-12) to develop a method to clean up a spent SHINE target solution prepared with uranyl sulfate. This process is described above. Discussions between Argonne and SHINE led to us look at a solution of 130 g-U/L solution of uranyl sulfate in sulfuric acid at pH 1. Briefly described below is the UREX flowsheet that was designed using the Argonne Model for Universal Solvent Extraction (AMUSE) for recovering pure uranium from that solution after it has been converted to nitrate media. The barium precipitation of sulfate is so effective that the number of stages developed for treating this solution is exactly the same as for the two earlier flowsheets. The only parameter that needed to be changed is the organic-to-aqueous (O/A) flow ratio in the extraction section. This ratio is maintained to provide a maximum loading of the tributyl phosphate (TBP) in the solvent to a range of 70–72%. This ratio should be kept high enough to minimize the extraction of other species into the solvent (to assure maximum decontamination of the uranium product), but low enough so that the organic phase will not divide into a light and heavy phase (third-phase formation) that would cause significant hydraulic problems for the contactor. As it was initially designed, an important feature of this flowsheet is the ease developing a new flowsheet if the concentration of uranium is modified. This means that the contactor in the hot cell can be permanently plumbed into four sections, with the requisite number of stages in each section. The only variable to be changed if the uranium concentration is modified is the flow rate of feed solutions.

Vandegrift, George F.↗

Evaluation of Argonne 9-cm and 10-cm Annular Centrifugal Contactors for SHINE Solution Processing

Work is in progress to evaluate the SHINE Medical Technologies process for producing Mo-99 for medical use from the fission of dissolved low-enriched uranium (LEU). This report addresses the use of Argonne annular centrifugal contactors for periodic treatment of the process solution. In a letter report from FY 2013, Pereira and Vandegrift compared the throughput and physical footprint for the two contactor options available from CINC Industries: the V-02 and V-05, which have rotor diameters of 5 cm and 12.7 cm, respectively. They suggested that an intermediately sized “Goldilocks” contactor might provide a better balance between throughput and footprint to meet the processing needs for the uranium extraction (UREX) processing of the SHINE solution to remove undesired fission products. Included with the submission of this letter report are the assembly drawings for two Argonne-design contactors that are in this intermediate range—9-cm and 10-cm rotors, respectively. The 9-cm contactor (drawing number CE-D6973A, stamped February 15, 1978) was designed as a single-stage unit and built and tested in the late 1970s along with other size units, both smaller and larger. In subsequent years, a significant effort to developed annular centrifugal contactors was undertaken to support work at Hanford implementing the transuranic extraction (TRUEX) process. These contactors had a 10-cm rotor diameter and were fully designed as multistage units with four stages per assembly (drawing number CMT-E1104, stamped March 14, 1990). From a technology readiness perspective, these 10-cm units are much farther ahead in the design progression and, therefore, would require significantly less re-working to make them ready for UREX deployment. Additionally, the overall maximum throughput of ~12 L/min is similar to that of the 9-cm unit (10 L/min), and the former could be efficiently operated over much of the same range of throughput. As a result, only the 10-cm units are considered here, though drawings are provided for the 9-cm unit for reference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro-SHINE Uranyl Sulfate Irradiations at the Linac

Peroxide formation due to water radiolysis in a uranyl sulfate solution is a concern for the SHINE Medical Technologies process in which Mo-99 is generated from the fission of dissolved low enriched uranium. To investigate the effects of power density and fission on peroxide formation and uranyl-peroxide precipitation, uranyl sulfate solutions were irradiated using a 50-MeV electron linac as part of the micro-SHINE experimental setup. Results are given for uranyl sulfate solutions with both high and low enriched uranium irradiated at different linac powers.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Compendium of Phase-I Mini-SHINE Experiments

Argonne National Laboratory is assisting SHINE Medical Technologies in their efforts to develop the technology to become a domestic Mo-99 producer using low-enriched uranium (LEU). Mini-SHINE experiments are being performed with the high-current electron linear accelerator (linac) at Argonne. The target solution is a 90-150 g-U/L LEU uranyl sulfate at pH 1. In Phase 1, the convertor was tantalum with a maximum beam power on the convertor of 10 kW, and the target solution was limited to 5 L. This configuration generated a peak fission power density of 0.05 W/mL. Nine experiments were performed between February and October 2015. Results are reported and discussed for each experiment regarding the off-gas analysis system, the sampling and Mo-recovery operation, and the Mo-product concentration and purification system. In Phase 2, the convertor will be depleted uranium; beam power will increase to 20 kW; and the solution volume will be 18 L. This configuration will generate a fission power density of up to 1 W/mL.

43 PARTICLE ACCELERATORS↗

Test plan for formulation and evaluation of grouted waste forms with shine process wastes

The objective of this experimental project is to demonstrate that waste streams generated during the production of Mo99 by the SHINE Medical Technologies (SHINE) process can be immobilized in cement-based grouted waste forms having physical, chemical, and radiological stabilities that meet regulatory requirements for handling, storage, transport, and disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Down-scale Experiments of Concentration Column Designs for SHINE Process

Argonne is assisting SHINE Medical Technologies in their efforts to become a domestic Mo-99 producer. The SHINE accelerator-driven process uses a uranyl-sulfate target solution for the production of fission-product Mo-99. Argonne has developed a molybdenum recovery and purification process for this target solution. The process includes an initial Mo recovery column followed by a concentration column to reduce the product volume from 15-25 L to < 1 L prior to entry into the LEU Modified Cintichem (LMC) process for purification.1 This report discusses direct down-scale experiments of the plant-scale concentration column design, where the effects of loading velocity and temperature were investigated.

42 ENGINEERING↗

Summary of LANL FY18 Technical Interface Coordination with SHINE

In FY18, Los Alamos National Laboratory (LANL) provided technical support for SHINE emergent needs and technical interface coordination including coordination of SHINE CFD/Thermal Hydraulics/transient analysis conference calls, Mo-99 meetings and reviews, national laboratory conference calls, and program management activities such as reporting and tracking requirements for cur rent FY18 activities. LANLhas also provided general technology consultation support for emerging issues.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Zircaloy-4 Welding and Hydrogen Charging Effects for Use as the Structural Material for the Target Solution Vessel and Support Lines of SHINE

The subcritical hybrid intense neutron emitter (SHINE) is a proposed 99 Mo production facility to be constructed in the United States. It uses a deuterium (D) and tritium (T) fusion source to cause subcritical fission in an aqueous uranium solution, which is cycled to collect the 99 Mo products. The target solution vessel (TSV) is the container of the aqueous uranium solution, so it must remain structurally sound during operational exposure to water, fission products, neutrons, and hydrogen isotopes. The TSV will be large enough to require welding, so the exposure of joints to these same conditions must also be considered. The candidate material being investigated is Zircaloy-4. While Zircaloy-4 has a long history in the nuclear industry, it has primarily been used as fuel cladding at service temperatures of ~300°C. Zircaloy-4 must be evaluated for behavior under neutron irradiation at SHINE-relevant temperatures of <100°C. In this project, the effects of hydrogen, welding, and neutron irradiation at low temperatures are investigated.

36 MATERIALS SCIENCE↗

Validation of MCNP5 for use in Calculating Temperature Coefficients of Reactivity for the SHINE System

Neutron transport calculations for the SHINE system are being done with MCNP, a general-purpose Monte Carlo NParticle code developed at Los Alamos National Laboratory (LANL). Current calculations are being done with MCNP5, version 1.6. This paper describes the methods used to calculate a tolerance band for temperature coefficients of reactivity (α{sub T}) calculated with MCNP5, v1.6 for the SHINE system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses

VENTSAR: Originated as VENTAX (Smith and Weber 1983) on the IBM Mainframe at the Savannah River Site (SRS) as a Fortran program. Updated to VENTSAR XL V1.0 (Simpkins 1997) as a spreadsheet version using macros created in Microsoft Excel. Later updated to VENTSAR XL V2.0 (Dixon 2018) as a spreadsheet executing a modified version of the original VENTAX Fortran code. Estimates contaminant concentrations on or near a building from a release at a nearby location. Calculates concentrations for a given meteorological exceedance probability or for a given stability and wind speed combination. Can model a single building with or without a penthouse on top or a ground location from either a stack or ground release. Plume rise can be considered. Contaminant releases can be chemical or radioactive with downwind concentrations determined at user-specified distances. Wind passing over and around buildings creates a complicated dispersion pattern. Air-intake vents may be located on building roofs or near the ground downwind of a release source. An estimation of pollutant concentrations on or near a structure is important in determining expected pollutant levels. Meteorological data are selected based on a specific area of the site. Fortran-based VENTAX able to make fast, complex mathematical calculations. Not user-friendly VENTSAR XL V1.0 no longer supported due to obsolete Excel macros. VENTSAR XL V2.0 an interim solution using an Excel spreadsheet to interface with the modified VENTAX Fortran code. Requires user to have Microsoft Excel. Not an intuitive interface for someone unfamiliar with VENTSAR. Does not perform dose calculations. VENTSAR V3.0 goal to combine the strengths of previous versions of VENTSAR into a single, powerful yet user-friendly program with a Graphical User Interface (GUI). Not dependent upon a specific program or plug-ins. Self-contained package to be used on any computer running Microsoft Windows. User-friendly, intuitive GUI created in Python for parameter input. Executes same modified VENTAX Fortran code as VENTSAR XL V2.0. Outputs formatted text file of completed calculations for easy review and dissemination. Performs inhalation and plume shine dose calculations for up to 11 user-selected nuclides from a nuclide dose factor library of almost 500 nuclides. 12 test cases were created for verification of V1.0 and V2.0. Same test cases run in V3.0 to verify correct performance. V3.0 produced similar results to V1.0. Confirmed GUI did not alter calculations in any way. Comparisons of the test case results confirm the V3.0 GUI does not influence the VENTSAR calculations. Simply passes same input parameters to VENTAX Fortran code for execution. Provides end user an easy-to-use, intuitive tool to quickly make building effect and plume rise calculations, as well as, inhalation and plume shine dose calculations. No experience with or working knowledge of Fortran, Excel, command line, or macros required. Self-contained package allows VENTSAR be deployed to any Windows computer without the need for specific programs or plug-ins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SHINE Vacuum Pump Test Verification

Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to the movement of tritium through the SHINE Tritium Purification System (TPS).

07 ISOTOPE AND RADIATION SOURCES↗

Light in the shadows: primordial black holes making dark matter shine

We consider the possibility of indirect detection of dark sector processes by investigating a novel form of interaction between ambient dark matter (DM) and primordial black holes (PBHs). The basic scenario we envisage is that the ambient DM is “dormant”, i.e., it has interactions with the SM, but its potential for an associated SM signal is not realized for various reasons. We argue that the presence of PBHs with active Hawking radiation (independent of any DM considerations) can act as a catalyst in this regard by overcoming the aforementioned bottlenecks. The central point is that PBHs radiate all types of particles, whether in the standard model (SM) or beyond (BSM), which have a mass at or below their Hawking temperature. The emission of such radiation is “democratic” (up to the particle spin), since it is based on a coupling of sorts of gravitational origin. In particular, such shining of (possibly dark sector) particles onto ambient DM can then activate the latter into giving potentially observable SM signals. We illustrate this general mechanism with two specific models. First, we consider asymmetric DM, which is characterized by an absence of ambient anti-DM, and consequently the absence of DM indirect detection signals. In this case, PBHs can “resurrect” such a signal by radiating anti-DM, which then annihilates with ambient DM in order to give SM particles such as photons. In our second example, we consider the PBH emission of dark gauge bosons which can excite ambient DM into a heavier state (which is, again, not ambient otherwise), this heavier state later decays back into DM and photons. Finally, we demonstrate that we can obtain observable signals of these BSM models from asteroid-mass PBHs (Hawking radiating currently with ~ $ \mathcal{O}\left(\textrm{MeV}\right) $ temperatures) at gamma-ray experiments such as AMEGO-X.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signals of millicharged dark matter in light-shining-through-wall experiments

We discuss a novel detection technique for millicharged dark matter that makes use of existing light-shining-through-wall (LSW) experiments searching for massive dark photons. Since millicharged particles interact with both the visible and dark sectors, a small background of such particles enables the search for visible signals even in the limit of a massless dark photon. Furthermore, for sufficiently large couplings, a small dark matter subcomponent consisting of millicharged particles can have a terrestrial abundance that is significantly enhanced with respect to its galactic abundance. We leverage this fact to show that in certain parts of parameter space, future runs of the LSW Dark SRF experiment can be used to set the strongest limits on millicharged relics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axions and 'light shining through a wall': A detailed theoretical analysis

We give a detailed study of axion-photon and photon-axion conversion amplitudes, which enter the analysis of 'light shining through a wall' experiments. Several different calculational methods are employed and compared, and in all cases we retain a nonzero axion mass. To leading order, we find that when the photon frequency {omega} is very close to the axion mass m, there is a threshold cusp which significantly enhances the photon to axion conversion amplitude, by a factor {omega}/{radical}({omega}{sup 2}-m{sup 2}) relative to the corresponding axion to photon conversion process. When m=0, the enhancement factor reduces to unity and the results of previous calculations are recovered. Our calculations include an exact wave matching analysis, which shows how unitarity is maintained near threshold at {omega}=m, and a discussion of the case when the magnetic field extends into the 'wall' region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isolated oxygen vacancies in strontium titanate shine red: Optical identification of Ti 3+ polarons

Oxide perovskites exhibit fascinating physical properties that identify them as key materials for the next generation of oxide-based functional electronic devices, as well as for catalysis and photochemistry applications. In strontium titanate, substantial efforts have been devoted to elucidate the role of oxygen vacancies and localized electronic states, such as polarons, on those properties. In this paper, a new model is presented that assigns a definitive red luminescence signature at 2.0 eV to Ti 3+ polarons trapped at isolated oxygen vacancies. This emission provides an unequivocal identification for the oxygen vacancies, which allows monitoring their creation and annealing by a variety of physio-chemical treatments. Ionoluminescence with energetic (MeV) ion beams enables such identification by combining the sensitivity and resolution of spectroscopic techniques with their in situ character, as well as controlled incorporation of point defects, such as oxygen vacancies. Alternative models assigning the blue luminescence emission at 2.8 eV to oxygen vacancies are not supported by the experimental results. Finally and therefore, oxygen vacancies shine red and not blue, as previously proposed.

36 MATERIALS SCIENCE↗