Search NASASearch

SEARCH · Search NASA

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY

Stability Limits of a PD Controller for a Flywheel Supported on Rigid Rotor and Magnetic Bearings

Active magnetic bearings are used to provide a long-life, low-loss suspension of a high-speed flywheel rotor. This paper describes a modeling effort used to understand the stability boundaries of the PD controller used to control the active magnetic bearings on a high speed test rig. Limits of stability are described in terms of allowable stiffness and damping values which result in stable levitation of the nonrotating rig. Small signal stability limits for the system is defined as a nongrowth in vibration amplitude of a small disturbance. A simple mass-force model was analyzed. The force resulting from the magnetic bearing was linearized to include negative displacement stiffness and a current stiffness. The current stiffness was then used in a PD controller. The phase lag of the control loop was modeled by a simple time delay. The stability limits and the associated vibration frequencies were measured and compared to the theoretical values. The results show a region on stiffness versus damping plot that have the same qualitative tendencies as experimental measurements. The resulting stability model was then extended to a flywheel system. The rotor dynamics of the flywheel was modeled using a rigid rotor supported on magnetic bearings. The equations of motion were written for the center of mass and a small angle linearization of the rotations about the center of mass. The stability limits and the associated vibration frequencies were found as a function of nondimensional magnetic bearing stiffness and damping and nondimensional parameters of flywheel speed and time delay.

Kascak, Albert F.

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters

Symbol error rate performance evaluation of the LM37 multimegabit telemetry modulator-demodulator unit

The LM37 multimegabit telemetry modulator-demodulator unit was tested for evaluation of its symbol error rate (SER) performance. Using an automated test setup, the SER tests were carried out at various symbol rates and signal-to-noise ratios (SNR), ranging from +10 to -10 dB. With the aid of a specially designed error detector and a stabilized signal and noise summation unit, measurement of the SER at low SNR was possible. The results of the tests show that at symbol rates below 20 megasymbols per second (MS)s) and input SNR above -6 dB, the SER performance of the modem is within the specified 0.65 to 1.5 dB of the theoretical error curve. At symbol rates above 20 MS/s, the specification is met at SNR's down to -2 dB. The results of the SER tests are presented with the description of the test setup and the measurement procedure.

Malek, H.

A Hybrid System for High-Accuracy Timekeeping Using Millisecond Pulsars

Millisecond pulsars exhibit extremely stable rotational periods with negligible long-term variation, comparable to atomic clocks. Leveraging pulsar signal stability, this paper presents a hybrid Pulse Per Second (PPS) generation system for high-accuracy and GPS-independent timing. The system combines pulsar and GPS signals through a high-speed data acquisition platform featuring FPGA-driven processing and techniques. This design provides a reliable and precise timekeeping solution for energy systems, ensuring functionality when GPS signals are unavailable.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Qualification and Performance of a High-Efficiency Laser Transmitter for Deep-Space Optical Communications

A high-power Laser Transmitter Assembly (LTA) was developed to support the Deep Space Optical Communications (DSOC) technology demonstration being developed by the Jet Propulsion Laboratory. NASA’s Psyche Mission plans to host the DSOC flight subsystem for testing space-to-ground high-bandwidth laser communications en route to the 16 Psyche asteroid. We review the design, performance, and qualification of the LTA Engineering Model and Flight Model (EM and FM) delivered to JPL. The LTA uses a master-oscillator power amplifier (MOPA) design and delivers up to 4.5 W at 1550 nm, with a highly efficient, cladding-pumped, polarization-maintaining erbium-ytterbium fiber amplifier. The master oscillator generates a range of pulse widths and repetition rates to support modulation formats from 16- to 128-PPM for optical data transmission at >100 Mbps. The LTA was designed for high reliability and radiation hardness, and includes redundant signal and pumping paths to reduce single points of failure, hardware interlocks to ensure safe operation and protection against damage, closed-loop control of optical power, and detailed health and status via telemetry. The LTA EM and FM were subjected to unit-appropriate space qualification testing. We describe the performance testing of the EM and FM, for the characterization of key metrics such as wavelength stability, signal linewidth, optical pulse width, jitter, and extinction ratio, and polarization extinction ratio. The management of optical nonlinearities (self-phase modulation, Brillouin scattering, or pulse-to-pulse energy variation), which could result in an optical link penalty or damage to the LTA, is also detailed, and factors affecting the power efficiency are discussed.

Jaques, J.

Gateway Power Quality Lessons Learned

Power Quality is a physical description of the electrical characteristics that allow the system to function properly without significant loss of performance or life. This physical description includes steady state voltage limits, transient voltage limits in normal/abnormal conditions, ripple voltage, stability, fault conditions, and more. All which are vital for improving reliability, ensuring stable operation, defining proper fault recovery, and ensuring a ‘plug and play’ approach to design and integration. Typically, a specification for Power Quality is created based on expected system performance or an existing standard, such as the International Space Power System Interoperability Standards (ISPSIS). One example of such a specification is the Gateway Power Quality Specification. It defines the requirements and characteristics of the 120 Volt direct current electrical power system for the Gateway Electrical Power System (EPS) and the Gateway Electrical Power Consuming Equipment (EPCE). This specification also maintains a separate requirement verification section that defines test methods for requirement verification. The test methods include analysis, test, inspection, and demonstration. These test methodologies and requirements are used to ensure that the loads operate when connected to the specified power quality and performance as defined by this specification. The challenge with developing a specification is that desired system characteristics are not always fully matured before the specification is needed and many performance requirements may be application specific. This drives the need to utilize lessons learned through extensive analysis and testing as well as historical knowledge to finalize requirements. Some example requirements where this is important are Small and Large Signal Stability, Ripple Voltage, Inrush/Surge Currents, and Fault Containment. Lessons learned are also important in the testing, analysis, and verification to ensure consistent and accurate results to verify performance. This presentation will cover the lessons learned for power quality relative to ripple, inrush/surge, fault containment, testing/verification, and more.

Power Quality

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING

Highly cascaded first-order fiber Bragg gratings in highly multimode optical fibers for distributed temperature sensing under harsh environment conditions

This study presents a pioneering technique for fabricating highly cascaded first-order fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method in highly multimode optical fibers, specifically Sapphire crystalline fiber, and pure silica coreless fiber. Notably, it marks the first successful demonstration of a distributed array comprising 10 FBGs within highly multimode fibers. This achievement is facilitated by a high-power laser technique that yields larger reflectors characterized by a Gaussian intensity profile. These first-order FBGs offer various advantages, including enhanced reflectivity, reduced fabrication time, and simplified spectral characteristics, enhancing their accessibility for interpretation when contrasted with higher-order FBGs. In addition to that it encompasses a comprehensive analysis of the robustness and efficacy of these FBGs, with particular emphasis on their ability to endure extreme temperatures. These FBGs demonstrate an advantageous capability for localized multi-point temperature monitoring, reaching temperatures up to 1500°C with sapphire crystalline fiber and 1100°C with pure silica coreless fiber. This resilience makes them suitable for deployment in harsh environmental conditions. This innovative approach substantially broadens the potential applications of highly multimode optical fibers, particularly in the arena of sensing and communication, where challenges related to thermal gradients and harsh environments prevail. Furthermore, these groundbreaking first-order FBGs signify a substantial advancement in the realm of distributed temperature sensing, offering supreme capabilities for temperature monitoring and signal stability. As such, our work holds the promise of a substantial impact on industries and applications that demand unwavering reliability under extreme conditions.

47 OTHER INSTRUMENTATION

HALLUFIELD: DETECTING LLM HALLUCINATIONS VIA FIELD-THEORETIC MODELING

A research-focused Python package that implements our hallucination-detection method for large language models(LLMs). The code computes stability signals from LLM predictions across various hyperparameters sweeps and combines free-energy/entropy–style metrics to flag likely hallucinations, with tunable thresholds for batch scoring. The repo includes evaluation scripts, config files, and example notebooks to reproduce benchmark results and ablations; it depends on standard open-source libraries (PyTorch, Hugging Face) and runs on CPU/GPU. The repository examples only use public models/datasets only.

Bhattarai, Manish [Los Alamos National Labs]

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.

Gating characteristics of photomultiplier tubes for Lidar applications

A detector test facility was developed and applied in the evaluation and characterization of lidar detectors in support of the multipurpose airborne differential absorption lidar (DIAL) system based at the Langley Research Center (LaRC). A performance data base of various detector configurations available to the DIAL system was obtained for optimum lidar detector selection. Photomultiplier tubes (PMT's) with multialkaline and bialkaline photocathodes were evaluated in voltage-divider networks (bases) by using either the focusing electrode or dynodes as a gating mechanism. Characteristics used for detector evaluation included gain stability, signal rise time, and the ability to block unwanted high light levels.

Barrick, J. D. W.

Coherent versus noncoherent signaling for satellite-aided mobile communications

The use of coherent versus noncoherent communications is an unresolved issue for the mobile satellite community. Should one select the more robust but less efficient noncoherent strategy for communications over satellite-aided mobile channels, or does the introduction of a space platform in the mobile link improve signal stability (both amplitude and phase) such that conventional coherent schemes become attractive? This publication tries to answer some of the questions by discussing the results from experiments using a coherent QPSK receiver. The issues discussed include items such as the measured performance in Rician fading, the link error floor in a fading environment, etc. The results are compared and contrasted with that of a noncoherent limiter/discriminator FM receiver.

Davarian, F.

Helicopter force-feel and stability augmentation system with parallel servo-actuator

A force-feel system is implemented by mechanically coupling a servo-actuator to and in parallel with a flight control system. The servo-actuator consists of an electric motor, a gearing device, and a clutch. A commanded cockpit-flight-controller position is achieved by pilot actuation of a trim-switch. The position of the cockpit-flight-controller is compared with the commanded position to form a first error which is processed by a shaping function to correlate the first error with a commanded force at the cockpit-flight-controller. The commanded force on the cockpit-flight-controller provides centering forces and improved control feel for the pilot. In an embodiment, the force-feel system is used as the basic element of stability augmentation system (SAS). The SAS provides a stabilization signal that is compared with the commanded position to form a second error signal. The first error is summed with the second error for processing by the shaping function.

Hoh, Roger H.

Spatio-Temporal Patterns of Optimal Landsat Data for Burn Severity Index Calculations: Implications for High Northern Latitudes Wildfire Research

Satellite remote sensing has been widely used for the evaluation of wildfire burn severity in various ecosystems. While a variety of remote sensing-based burn severity indices have been developed, the Landsat-based differ-enced Normalized Burn Ratio (dNBR) presents the most widely-used approach to burn severity assessment for fire research and management. Although dNBR-based approaches have been continuously updated, including the development of the relative dNBR (RdNBR) and the Relativized Burn Ratio (RBR), one key obstacle for the reliable applications of the burn severity indices in the high northern latitudes has not been adequately addressed. Specifically, optimal Landsat image pairs are very rarely available for the calculation of the burn severity indices in certain regions of the high northern latitudes (HNL), resulting in the burn severity index outputs calculated for a large number of wildfires being considerably affected by non-fire-related factors. The suboptimal selection of image pairs may have partially contributed to the lack of consistency in the performance of the burn severity indices in the HNL regions. In this paper, we systematically evaluated the impacts of sub-optimal image pairs on signal stability through two sets of analyses conducted at different spatial scales. First, at the regional scale, we examined the burn severity indices calculated for a selection of wildfires in Alaska. Here, we demonstrate the inconsistent performance of the same index calculated based on Landsat data that are typically considered as “optimal”. In addition, we show that the calculated indices may be more prone to the negative impacts of these inconsistencies, thus leading to reduced reliability, when there is limited Landsat data availability. Second, at the continental scale, we show that certain areas in the HNL, especially Alaska during the pre-2000 era, are subject to the potentially strong negative impact associated with the limited data availability. Through systematically analyzing this issue, we hope to not only divert more attention to it but also to provide potential solutions, based on which further improvements that may be of particular importance for research on Arctic wildfires could be made.

Dong Chen