At least 37 records · Page 2

Validation of Pronghorn for Natural-Circulation Molten Salt Loops

This paper presents the development and validation of a high-fidelity thermal-hydraulic model of a molten salt natural circulation flow loop, designed for integration within a digital twin framework. The study evaluates the performance of Idaho National Laboratory’s Pronghorn against experimental data from Texas A&M University Molten Salt Flow Loop (MSFL) four Hitec-salt test benchmark data. Natural circulation of high-Prandtl-number fluids exhibits complex, counter-intuitive flow patterns that make pointwise thermocouple readings unreliable. Experimental work at TAMU’s MSFL provides benchmark data, including flow visualization at a test-section and centerline steady-state temperature measurements along the loop. Validation includes four single-phase natural circulation test cases with Hitec salt. Key metrics include flow profile agreement and steady-state temperature accuracy. Pronghorn results for two-dimensional single-phase agree qualitatively with the experimental flow profile. This paper illustrates the importance of Computational Fluid Dynamics (CFD) in elucidating the behavior of high-Prandtl-number thermal-hydraulics, along with how misleading centerline temperature measurements can be. Pronghorn reproduces the axial and radial stratification that makes single thermocouple readings unreliable. Future research will focus on reduced-order modeling techniques to enable rapid simulation suitable for real-time digital twin applications. The validated cases provide a basis for developing reduced-order surrogates aimed at real-time digital-twin applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Pseudo-viscous modeling of transport in dense granular flows for thermal energy storage applications

Dense, granular flows were examined to effectively capture and model bulk viscous properties in thin packed beds. A modified Couette cell with particle image velocimetry was used to experimentally determine pseudo-viscosity properties of four particulate media with varying morphologies: (1) iron oxide-coated SiO 2 particles, (2) CARBOBEAD CP30-60 particles, (3) CARBOBEAD CP40-100 particles, and (4) Al 2 O 3 beads. The pseudo-viscosity functions were fitted using a power law to correlate the measured shear stress as a function of measured shear rate. The pseudo-viscous functions were used as inputs to computation fluid dynamics models for a single-phase viscous fluid to predict granular flow profiles. Steady-state free surface velocity profiles at angular velocities <7 rad/s predicted by the model were in good agreement with the experimental particle image velocimetry measurements, resulting in Pearson correlation coefficients of 0.97 for iron-oxide coated SiO 2 particles and 0.95 for CP30-60 particles. As a result, this alternative approach to measuring pseudo-viscous properties under shearing and modeling bulk transport behavior of granular flow using computation fluid dynamics model offered significant reduction in computational load compared to discrete element methods.

14 SOLAR ENERGY

Instrument continuously measures density of flowing fluids

Electromechanical densitometer continuously measures the densities of either single-phase or two-phase flowing cryogenic fluids. Measurement is made on actual flow. The instrument operates on the principle that the mass of any vibrating system is a primary factor in determining the dynamic characteristics of the system.

Jacobs, R. B.

Reduced-Order CFD Modeling to Support Waste Loading Optimization in Hanford WTP Vitrification

The U.S. DOE Hanford Site stores over 56 million gallons of radioactive liquid tank waste that must be treated and immobilized for long-term disposal The Waste Treatment and Immobilization Plant (WTP) will vitrify this waste by feeding it into Joule-heated melters, where it is incorporated into a stable borosilicate glass Computational fluid dynamics (CFD) simulations of glass melters can provide insight into the maximum achievable waste loading under varying melter operating conditions Fully resolved VOF multiphase simulations were used as the reference model to capture bubble-driven convection in the melter, including bubble formation, rise behavior, and induced glass melt circulation Effective bubble column diameter and rise velocity were extracted from the resolved simulations, compared with empirical correlations, and refit across relevant viscosity and gas flow rate conditions Explicit gas–liquid interface tracking was replaced with a single-phase momentum source term model, enabling faster steady-state CFD simulations while preserving the dominant hydrodynamic effects of bubbling New empirical correlations were developed for effective bubble column diameter and bubble rise velocity by fitting resolved simulation data across expected melter viscosity and gas flow rate ranges, providing improved inputs for the momentum source term model compared with existing literature correlations The momentum source term model reduced fluid-domain mesh size by 89% and achieved an 8.4× computational speedup relative to resolved bubbling simulations The validated momentum source term approach enables prediction of process-relevant heat transfer behavior in the integrated melter model, including heat transfer from the molten glass to the cold cap, plenum, refractory walls, and surrounding structural regions under varying melter operating conditions

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Microstructural, Oxidation, and Mechanical Behavior of NbTi-Based Refractory Alloys with 5 to 10 Pct Co, Cr, and Ni Additions

NbTi-based refractory alloys with additions of Co, Cr, and Ni represent an interesting medium-entropy alloy system with potential for protective oxide film formation, high strength, and ductility. This study investigates the microstructural evolution, oxidation behavior, and mechanical properties of NbTi-based alloys containing 5 to 10 at. pct Co, Cr, and Ni. CALPHAD predictions suggest that this composition range can be heat treated to obtain a predominantly body-centered cubic matrix phase. Mechanical properties, including microhardness, yield strength, maximum strength, and specific strength are evaluated through isothermal compression tests conducted between room temperature and 800 °C. The oxidation kinetics of these alloys are assessed through discontinuous oxidation tests. Parabolic oxidation kinetics were observed for NbTi–10Ni and NbTi–5Co, while linear oxidation kinetics were found for NbTi–10Cr and NbTi–10(CoCrNi). Microstructures and oxide layers are characterized using X-ray diffraction, electron backscatter diffraction, energy-dispersive X-ray spectroscopy, and scanning electron microscopy. All alloys exhibit significant mechanical softening between room temperature and 800 °C, with elastic-perfectly plastic flow observed at 800 °C. The addition of 10 pct Cr to NbTi resulted in two BCC phases up to 1050 °C, conflicting with CALPHAD predictions of a single-phase solid solution at this temperature, and resulting in higher flow stress at 800 °C. NbTi–10(CoCrNi) exhibited the lowest flow stress at 800 °C despite having more ‘cocktail effect’ potential and insufficient molar fractions of Co, Cr, or Ni to form a desirable protective oxide film.

36 MATERIALS SCIENCE

A Colebrook equation for impinging radial wall jets

Here, in this study, we evaluate the skin coefficient of friction for steady turbulent radial wall jets across smooth and rough surfaces. Although the Colebrook equation has been used successfully for many decades to evaluate friction factors for flows through smooth and rough pipes, how roughness affects the skin friction coefficient for steady turbulent radial wall jets remains unclear. Here we explore a Colebrook-type equation for skin friction coefficients associated with single-phase turbulent radial wall jets arising from orthogonally impinging circular jets. The fully iterative solution, based on well-established concepts of turbulent wall-bounded flow, is presented along with a power-law approximation and a non-iterative approximation for the friction coefficient derived therefrom. We find the skin coefficient of friction defined on the peak radial velocity to be a function of position over rough but not smooth surfaces in contrast to pipe friction factors that remain independent of axial position. These results follow expected trends, explain prior heterogeneity in power-law expressions for the skin friction coefficient and have significant implications for the industrial use of jets in mixing vessels.

friction losses

Differentiable multiphase flow model for physics-informed machine learning in reservoir pressure management

Accurate subsurface reservoir pressure control is extremely challenging due to geological heterogeneity and multiphase fluid-flow dynamics. Predicting behavior in this setting relies on high-fidelity physics-based simulations that are computationally expensive. Yet, the uncertain, heterogeneous properties that control these flows make it necessary to perform many of these expensive simulations, which is often prohibitive. To address these challenges, we introduce a physics-informed machine learning workflow that couples a fully differentiable multiphase flow simulator, which is implemented in the DPFEHM framework with a convolutional neural network (CNN). The CNN learns to predict fluid extraction rates from heterogeneous permeability fields to enforce pressure limits at critical reservoir locations. By incorporating transient multiphase flow physics into the training process, our method enables more practical and accurate predictions for realistic injection-extraction scenarios compared to previous works. To speed up training, we pretrain the model on single-phase, steady-state simulations and then finetune it on full multiphase scenarios, which dramatically reduces the computational cost. We demonstrate that high-accuracy training can be achieved with fewer than three thousand full-physics multiphase flow simulations – compared to previous estimates requiring up to ten million. This drastic reduction in the number of simulations is achieved by leveraging transfer learning from much less expensive single phase simulations.

25 ENERGY STORAGE

Rules for the crystallite size and dislocation density evolution in phases during α-ω transformation in Zr under high-pressure and severe plastic flow

The first in-situ X-ray diffraction (XRD) study of the evolution of the crystallite size and dislocation density in phases during plastic strain-induced phase transformation (PT) is performed utilizing α-ω PT in strongly pre-deformed commercially pure Zr as an important example. Rough diamond anvils (rough-DA) are introduced to intensify all occurring processes during heterogeneous compression of Zr in a diamond anvil cell (DAC). The main rule is found that during α-ω PT the crystallite size and dislocation density in ω-Zr depend solely on the volume fraction of ω-Zr and are independent of pressure, plastic strain tensor, its path, and initial nanostructure. Crystallite size in ω-Zr increases from 10 to 60 nm during the PT, while dislocation density reduces from 1.83×10 15 /m 2 to 0.6×10 15 /m 2 . Rough-DA produce a steady nanostructure in α-Zr before PT with smaller crystallite size and larger dislocation density than smooth-DA, leading to a reduction of the minimum pressure for α-ω PT to a record value 0.67 GPa, 9 times smaller than under hydrostatic loading and 5.1 times lower than the phase equilibrium pressure. In addition to strain, the kinetics of strain-induced PT unexpectedly depends on time. Also, strain-controlled part of kinetics is zero order, in contrast to the first-order kinetics with smooth-DA. The obtained results open a new window for understanding the mutual effects of nanostructure evolution and PT during severe plastic flow in various technological and natural processes. In conclusion, they may bring up economic strategies of producing nanocomposites and single-phase nanostructured materials with optimal properties.

Crystalline size

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY

Electrified vapour deposition at ultrahigh temperature and atmospheric pressure for nanomaterials synthesis

Vapour-phase synthesis methods have shown promise for the scalable synthesis of nanomaterials and coatings. However, the vaporization of different precursors for the synthesis of a broad nanomaterial space, particularly at atmospheric pressure, while maintaining compositional and structural control of the final product is challenging. Here we report the generation of an ultrahigh-temperature atomic vapour at atmospheric pressure based on electrified heating, for the growth of multi-elemental nanomaterials and thin films. This process relies on a reactor design whereby solid-state precursors are vaporized within a semi-confined space beneath an electrified heater that can reach ~3,000 K. The proximity of the heater rapidly breaks down the bonds of metal salt precursors and decomposes them into an atomic vapour that expands into a high-temperature (>2,000 K), highly reactive and high-flux vapour (10 21 –10 22 atoms per cm 2 per second) that travels upwards in a directional flow. When mixed with entrained ambient gases, the highly reactive atomic species rapidly nucleate and grow into the desired final products, including alloys, oxides, sulfides and thin films, which can be deposited on a low-temperature substrate. This EVD approach can synthesize a broad range of functional nanomaterials at atmospheric pressure, including single-phase multi-elemental nanomaterials formed under thermodynamically non-equilibrium conditions.

36 MATERIALS SCIENCE

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration

FY-25 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the system level modeling using RELAP5-3D of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY25. This year’s work focuses on a new tank configuration where the inlet of the tank was lowered in elevation by 45”. The stability boundaries of the NSTF are thoroughly studied and stability maps are constructed based on the stability and the oscillation patterns of the system. Five distinct operational modes are identified, namely single-phase liquid, uniform double peak oscillations, uniform sinusoidal oscillations, stable two-phase flow, and non-uniform oscillations. Next, the riser inlet throttling case of experimental test Run-104 is simulated with the RELAP5 model where good agreement is obtained between the model and the experimental data. The simulation also highlights the effects of backflow of water from the tank to the upper region of the chimney. Additionally, the decay heat removal test of Run-99 is simulated with the RELAP5 model. Comparison is carried out between this run and a similar run with the mid-tank inlet of Run-74 performed in FY22. With the lower tank inlet, the RELAP5 model is able to predict the experimental data more accurately than the previous mid tank inlet configuration. The discrepancy in model prediction accuracy highlights the non-symmetrical spatial effects in the tank that would otherwise be more easily captured with higher fidelity models. Lastly, two exploratory studies are conducted to investigate the behaviors of the NSTF when 1) heating is provided to the downcomer and 2) a bypass channel is added between the horizontal chimney section to the downcomer.

42 ENGINEERING

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation