Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLAR ADVISOR MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PV array simulator development and validation.

The ability to harvest all available energy from a photovoltaic (PV) array is essential if new system developments are to meet levelized cost of energy targets and achieve grid parity with conventional centralized utility power. Therefore, exercising maximum power point tracking (MPPT) algorithms, dynamic irradiance condition operation and startup and shutdown routines and evaluating inverter performance with various PV module fill-factor characteristics must be performed with a repeatable, reliable PV source. Sandia National Laboratories is collaborating with Ametek Programmable Power to develop and demonstrate a multi-port TerraSAS PV array simulator. The simulator will replicate challenging PV module profiles, enabling the evaluation of inverter performance through analyses of the parameters listed above. Energy harvest algorithms have traditionally implemented methods that successfully utilize available energy. However, the quantification of energy capture has always been difficult to conduct, specifically when characterizing the inverter performance under non-reproducible dynamic irradiance conditions. Theoretical models of the MPPT algorithms can simulate capture effectiveness, but full validation requires a DC source with representative field effects. The DC source being developed by Ametek and validated by Sandia is a fully integrated system that can simulate an IV curve from the Solar Advisor Model (SAM) module data base. The PV simulator allows the user to change the fill factor by programming the maximum power point voltage and current parameters and the open circuit voltage and short circuit current. The integrated PV simulator can incorporate captured irradiance and module temperature data files for playback, and scripted profiles can be generated to validate new emerging hardware embedded with existing and evolving MPPT algorithms. Since the simulator has multiple independent outputs, it also has the flexibility to evaluate an inverter with multiple MPPT DC inputs. The flexibility of the PV simulator enables the validation of the inverter's capability to handle vastly different array configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Grid-Competitive Residential and Commercial Fully Automated PV Systems Technology: Final technical Report, August 2011

Under DOE's Technology Pathway Partnership program, SunPower Corporation developed turn-key, high-efficiency residential and commercial systems that are cost effective. Key program objectives include a reduction in LCOE values to 9-12 cents/kWh and 13-18 cents/kWh respectively for the commercial and residential markets. Target LCOE values for the commercial ground, commercial roof, and residential markets are 10, 11, and 13 cents/kWh. For this effort, SunPower collaborated with a variety of suppliers and partners to complete the tasks below. Subcontractors included: Solaicx, SiGen, Ribbon Technology, Dow Corning, Xantrex, Tigo Energy, and Solar Bridge. SunPower's TPP addressed nearly the complete PV value chain: from ingot growth through system deployment. Throughout the award period of performance, SunPower has made progress toward achieving these reduced costs through the development of 20%+ efficient modules, increased cell efficiency through the understanding of loss mechanisms and improved manufacturing technologies, novel module development, automated design tools and techniques, and reduced system development and installation time. Based on an LCOE assessment using NREL's Solar Advisor Model, SunPower achieved the 2010 target range, as well as progress toward 2015 targets.

14 SOLAR ENERGY↗

Water Use in Parabolic Trough Power Plants: Summary Results from WorleyParsons' Analyses

The National Renewable Energy Laboratory (NREL) contracted with WorleyParsons Group, Inc. to examine the effect of switching from evaporative cooling to alternative cooling systems on a nominal 100-MW parabolic trough concentrating solar power (CSP) plant. WorleyParsons analyzed 13 different cases spanning three different geographic locations (Daggett, California; Las Vegas, Nevada; and Alamosa,Colorado) to assess the performance, cost, and water use impacts of switching from wet to dry or hybrid cooling systems. NREL developed matching cases in its Solar Advisor Model (SAM) for each scenario to allow for hourly modeling and provide a comparison to the WorleyParsons results.Our findings indicate that switching from 100% wet to 100% dry cooling will result in levelized cost ofelectricity (LCOE) increases of approximately 3% to 8% for parabolic trough plants throughout most of the southwestern United States. In cooler, high-altitude areas like Colorado's San Luis Valley, WorleyParsons estimated the increase at only 2.5%, while SAM predicted a 4.4% difference. In all cases, the transition to dry cooling will reduce water consumption by over 90%. Utilitytime-of-delivery (TOD) schedules had similar impacts for wet- and dry-cooled plants, suggesting that TOD schedules have a relatively minor effect on the dry-cooling penalty.

14 SOLAR ENERGY↗

Current and Future Costs for Parabolic Trough and Power Tower Systems in the US Market: Preprint

NREL's Solar Advisor Model (SAM) is employed to estimate the current and future costs for parabolic trough and molten salt power towers in the US market. Future troughs are assumed to achieve higher field temperatures via the successful deployment of low melting-point, molten-salt heat transfer fluids by 2015-2020. Similarly, it is assumed that molten salt power towers are successfully deployedat 100MW scale over the same time period, increasing to 200MW by 2025. The levelized cost of electricity for both technologies is predicted to drop below 11 cents/kWh (assuming a 10% investment tax credit and other financial inputs outlined in the paper), making the technologies competitive in the marketplace as benchmarked by the California MPR. Both technologies can be deployed with largeamounts of thermal energy storage, yielding capacity factors as high as 65% while maintaining an optimum LCOE.

14 SOLAR ENERGY↗

Current and future costs for parabolic trough and power tower systems in the US market.

NREL's Solar Advisor Model (SAM) is employed to estimate the current and future costs for parabolic trough and molten salt power towers in the US market. Future troughs are assumed to achieve higher field temperatures via the successful deployment of low melting-point, molten-salt heat transfer fluids by 2015-2020. Similarly, it is assumed that molten salt power towers are successfully deployed at 100MW scale over the same time period, increasing to 200MW by 2025. The levelized cost of electricity for both technologies is predicted to drop below 11 cents/kWh (assuming a 10% investment tax credit and other financial inputs outlined in the paper), making the technologies competitive in the marketplace as benchmarked by the California MPR. Both technologies can be deployed with large amounts of thermal energy storage, yielding capacity factors as high as 65% while maintaining an optimum LCOE.

14 SOLAR ENERGY↗

System Advisor Model (SAM) Improvements for Emerging Solar Thermal Applications

The System Advisor Model (SAM) is an open-source tool developed by NREL to simulate the techno-economic performance of technologies like photovoltaics, solar thermal, wind, and geothermal. NREL has recently completed, active, and planned projects to improve the solar thermal models in SAM and its underlying code base to represent emerging component technologies, systems, and applications. This poster describes new capabilities in the SolarPILOT optical modeling tool, supercritical carbon dioxide (sCO2) power cycles, and solar industrial process heat.

14 SOLAR ENERGY↗

Foundational Open Source Solar System Modeling Through Improvement and Validation of the System Advisor Model and PVWatts (FY19-FY21 Final Technical Report)

Accelerating intelligent deployment of solar energy technologies demands accurate system modeling every step of the way. From project development to policy research, grid integration studies to development of novel technologies, industry and researchers alike need validated, transparent, easy-to-use, extensible, cutting-edge, and accurate models of both the performance and financing of solar systems. The System Advisor Model (SAM) and PVWatts tools provide a platform to fill that need. The overarching goal of this set of software tools is to enable accurate PV system modeling across the industry, and our usage metrics indicate that we continue to succeed in that endeavor, with a user starting SAM every 2 minutes globally, and over 17 million PVWatts hits per month. This project leveraged DOEs past investment in the SAM and PVWatts platforms to continue to provide valuable and extensible PV, battery, and financial modeling resources to the larger solar community. We pursued multiple avenues in parallel: software maintenance and technical support that are foundational to the continued usability of the SAM and PVWatts platforms; platform and PV model improvements and stakeholder engagement activities that are core to the continued relevance of the platforms; and open source activities to foster the continued creation of a vibrant open-source community around the SAM and PVWatts tools, which opens up exciting new opportunities for industry interaction.

14 SOLAR ENERGY↗

P50/P90 Analysis for Solar Energy Systems Using the System Advisor Model: Preprint

To secure competitive financing for a solar energy generation project, the economic risk associated with interannual solar resource variability must be quantified. One way to quantify this risk is to calculate exceedance probabilities representing the amount of energy expected to be produced by a plant. Many years of solar radiation and metereological data are required to determine these values,often called P50 or P90 values for the level of certainty they represent. This paper describes the two methods implemented in the National Renewable Energy Laboratory's System Advisor Model (SAM) to calculate P50 and P90 exceedance probabilities for solar energy projects. The methodology and supporting data sets are applicable to photovoltaic, solar water heating, and concentrating solar power(CSP) systems.

14 SOLAR ENERGY↗

Generic CSP Performance Model for NREL's System Advisor Model: Preprint

The suite of concentrating solar power (CSP) modeling tools in NREL's System Advisor Model (SAM) includes technology performance models for parabolic troughs, power towers, and dish-Stirling systems. Each model provides the user with unique capabilities that are catered to typical design considerations seen in each technology. Since the scope of the various models is generally limited to commonplant configurations, new CSP technologies, component geometries, and subsystem combinations can be difficult to model directly in the existing SAM technology models. To overcome the limitations imposed by representative CSP technology models, NREL has developed a 'Generic Solar System' (GSS) performance model for use in SAM. This paper discusses the formulation and performance considerationsincluded in this model and verifies the model by comparing its results with more detailed models.

14 SOLAR ENERGY↗

Technical Manual for the SAM Physical Trough Model

NREL, in conjunction with Sandia National Lab and the U.S Department of Energy, developed the System Advisor Model (SAM) analysis tool for renewable energy system performance and economic analysis. This paper documents the technical background and engineering formulation for one of SAM's two parabolic trough system models in SAM. The Physical Trough model calculates performance relationshipsbased on physical first principles where possible, allowing the modeler to predict electricity production for a wider range of component geometries than is possible in the Empirical Trough model. This document describes the major parabolic trough plant subsystems in detail including the solar field, power block, thermal storage, piping, auxiliary heating, and control systems. This model makesuse of both existing subsystem performance modeling approaches, and new approaches developed specifically for SAM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing the Value of Photovoltaic Installations on Schools in California: Choosing the Best Electricity Rates

Schools in California often have a choice between multiple electricity rate options. For schools with photovoltaic (PV) installations, choosing the right rate is essential to maximize the value of PV generation. The rate option that minimizes a school's electricity expenses often does not remain the most economical choice after the school installs a PV system. The complex interaction between PVgeneration, building load, and rate structure makes determining the best rate a challenging task. This report evaluates 22 rate structures across three of California's largest electric utilities--Pacific Gas and Electric Co. (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E)--in order to identify common rate structure attributes that are favorable to PVinstallations.

14 SOLAR ENERGY↗

NREL's System Advisor Model Simplifies Complex Energy Analysis (Fact Sheet)

NREL has developed a tool -- the System Advisor Model (SAM) -- that can help decision makers analyze cost, performance, and financing of any size grid-connected solar, wind, or geothermal power project. Manufacturers, engineering and consulting firms, research and development firms, utilities, developers, venture capital firms, and international organizations use SAM for end-to-end analysis that helps determine whether and how to make investments in renewable energy projects.

14 SOLAR ENERGY↗

Improvement and Validation of the System Advisor Model

The System Advisor Model (SAM) and PVWatts tools have been key successes and core facilities of the DOE EERE suite of capabilities for the last fifteen years, and have grown into a first-class and one-of-a-kind software suite for solar energy technology systems, incorporating best-in-class models for detailed performance and techno-economic analysis. This final report describes accomplishments of this project to continue to achieve high impact for all stakeholders.

14 SOLAR ENERGY↗

Case Study of a Californian Brewery to Potentially Use Concentrating Solar Power for Renewable Heat Generation

With the increasing relevance and acceptance of solar thermal for industrial process heat (IPH), a case study for a proposed concentrating solar power (CSP) integration into an existing Californian brewery is highlighted. The thermal generation from a 1 MWth solar field was modelled in the System Advisor Model (SAM), and the economics considered the viability of the project where different variables such as the installed solar field cost were investigated on metrics such as Net Present Value (NPV) and payback period. For the Base Case, without the 30% Investment Tax Credit (ITC), and using a 2017 Federal income tax rate of 35%, the project’s NPV reached $0 (i.e., the project becomes viable), when the installed solar field cost reached $158/m2. With the 30% ITC and 35% tax, the solar field installed cost is estimated at $324/m2 to obtain an NPV = $0. The biggest influences on project viability measured by NPV were the project life, Federal tax rate, and the solar field cost.

case study↗

Parabolic Trough Collector Cost Update for the System Advisor Model (SAM)

This report updates the baseline cost for parabolic trough solar fields in the United States within NREL's System Advisor Model (SAM). SAM, available at no cost at https://sam.nrel.gov/, is a performance and financial model designed to facilitate decision making for people involved in the renewable energy industry. SAM is the primary tool used by NREL and the U.S. Department of Energy (DOE) for estimating the performance and cost of concentrating solar power (CSP) technologies and projects. The study performed a bottom-up build and cost estimate for two state-of-the-art parabolic trough designs -- the SkyTrough and the Ultimate Trough. The SkyTrough analysis estimated the potential installed cost for a solar field of 1500 SCAs as $170/m 2 +/- $6/m 2 . The investigation found that SkyTrough installed costs were sensitive to factors such as raw aluminum alloy cost and production volume. For example, in the case of the SkyTrough, the installed cost would rise to nearly $210/m 2 if the aluminum alloy cost was $1.70/lb instead of $1.03/lb. Accordingly, one must be aware of fluctuations in the relevant commodities markets to track system cost over time. The estimated installed cost for the Ultimate Trough was only slightly higher at $178/m 2 , which includes an assembly facility of $11.6 million amortized over the required production volume. Considering the size and overall cost of a 700 SCA Ultimate Trough solar field, two parallel production lines in a fully covered assembly facility, each with the specific torque box, module and mirror jigs, would be justified for a full CSP plant.

47 OTHER INSTRUMENTATION↗

NREL's System Advisor Model Simplifies Complex Energy Analysis (Fact Sheet)

The energy market is diversifying. In addition to traditional power sources, decision makers can choose among solar, wind, and geothermal technologies as well. Each of these technologies has complex performance characteristics and economics that vary with location and other project specifics, making it difficult to analyze the viability of such projects. But that analysis is easier now, thanks to the National Renewable Energy Laboratory (NREL).

14 SOLAR ENERGY↗

Solar Field Optical Characterization at Stillwater Geothermal/Solar Hybrid Plant

Concentrating solar power (CSP) can provide additional thermal energy to boost geothermal plant power generation. For a newly constructed solar field at a geothermal power plant site, it is critical to properly characterize its performance so that the prediction of thermal power generation can be derived to develop an optimum operating strategy for a hybrid system. In the past, laboratory characterization of a solar collector has often extended into the solar field performance model and has been used to predict the actual solar field performance, disregarding realistic impacting factors. In this work, an extensive measurement on mirror slope error and receiver position error has been performed in the field by using the optical characterization tool called Distant Observer (DO). Combining a solar reflectance sampling procedure, a newly developed solar characterization program called FirstOPTIC and public software for annual performance modeling called System Advisor Model (SAM), a comprehensive solar field optical characterization has been conducted, thus allowing for an informed prediction of solar field annual performance. The paper illustrates this detailed solar field optical characterization procedure and demonstrates how the results help to quantify an appropriate tracking-correction strategy to improve solar field performance. In particular, it is found that an appropriate tracking-offset algorithm can improve the solar field performance by about 15%. The work here provides a valuable reference for the growing CSP industry.

14 SOLAR ENERGY↗