SEARCH · Search NASA
Results for “SOLAR SIMULATION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance and operating characteristics of a 4.88-M diameter solar simulator for Viking space simulation tests
The solar simulator met the solar radiation requirements of the two and a half year Viking test program, but not without some interesting problems and experiences. Operating characteristics of the simulator, the system maintenance program, and the test program are described.
Solar simulation studies Summary
Solar simulation - paint testing, planning for high altitude tests of spectral irradiance, pressure arc and vortex stabilized radiation systems, and thermal control coating tests
An evaluation by solar simulation of radiation damage in silicon solar cells.
Radiation damage experiments for evaluation of silicon solar cell characteristics under simulated solar light
Solar simulation in the MSC Space Environment Simulation Laboratory
The MSC Solar Simulator history and requirements for the Space Environment Simulation Laboratory (SESL) are briefly reviewed. A description is presented of the SESL, and a discussion is included of the solar simulator development and present status. A Radiant Intensity Measuring System for the SESL is briefly described.
Large area pulsed solar simulator
An advanced solar simulator illuminates the surface a very large solar array, such as one twenty feet by twenty feet in area, from a distance of about twenty-six feet with an essentially uniform intensity field of pulsed light of an intensity of one AMO, enabling the solar array to be efficiently tested with light that emulates the sun. Light modifiers sculpt a portion of the light generated by an electrically powered high power Xenon lamp and together with direct light from the lamp provide uniform intensity illumination throughout the solar array, compensating for the square law and cosine law reduction in direct light intensity, particularly at the corner locations of the array. At any location within the array the sum of the direct light and reflected light is essentially constant.
Verification test of the MSFC solar simulator using a Honeywell double-covered liquid solar collector
Additional verification data to support the utilization of the MSFC Solar Simulator for testing solar collectors was obtained. The Honeywell double-covered liquid solar collector number 2 for which thermal performance data under natural outdoor conditions had been previously obtained was installed on the Solar Simulator and subjected to a series of eight tests under various conditions of wind flow rate. Although these test conditions were not absolutely identical to those of the outdoor tests, they are considered to be sufficiently representative to provide a basis for an accurate comparative analysis of the data recorded for both test programs.
Standardized solar simulator tests of flat plate solar collectors. 1: Soltex collector with two transparent covers
A Soltex flat plate solar collector was tested with a solar simulator for inlet temperatures of 77 to 201 F, flux levels of 240 and 350 Btu/hr-sq ft, a collant flow rate of 10.5 lb/hr sq ft, and incident angles of 0 deg, 41.5 deg, and 65.2 deg. Collector performance is correlated in terms of inlet temperature, flux level, and incident angle.
Solar simulator mirror refurbishment
Solar simulator mirrors were refurbished. Two different refurbishment methods were employed. In the first, the electroformed mirror replica was removed from the casting and replaced with a new mirror replica. In the second, only the aluminized surface, with its protective overcoat, was removed from the mirror and replaced after cleaning of the nickel surface.
AMC EN-1038: Reduced scale solar simulator supplementary test report
The reduced scale solar simulator program conducted by the Advanced Manufacturing Center at Cleveland State University in 1992 provided sufficient data to support the selection of the uniform magnification solar simulator module for the Solar Dynamic Ground Test Demonstrator Program (SDGTD) at NASA LeRC. In 1993, additional testing of the reduced scale solar simulator was conducted to provide information to refine and improve the design of the full scale solar simulator. This report presents the results of these additional tests.
Status of solar simulation at Lewis
Evaluation of solar simulators using enclosed sources, in-house measurement facility for testing proposed devices to produce solar simulation, and related research programs
Solar panel thermal cycling testing by solar simulation and infrared radiation methods
For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.
Project ASSESS - A report of a long term solar simulation test.
Long term solar simulation test, noting spacecraft performance, equipment design, instrumentation, etc
Fidelity of a xenon on-axis solar simulator
Xenon on-axis solar simulators are currently used in the thermal vacuum test chambers at NASA Johnson Space Center. These simulators provide a controllable system to closely match the radiation conditions in space. Through a series of alignment procedures, the uniformity, controllability, and spectral distribution of the simulators are certified in order to provide good correlation with theoretical analysis. This certification demonstrates the high fidelity output of the xenon solar simulator.
Solar-cell performance at low temperatures and simulated solar intensities
Photovoltaic properties of cadmium sulfide and silicon solar cells at low temperatures and simulated solar intensities
Spectrographic measurements of solar simulation sources
Spectrographic measurements of solar simulation sources
Experimental study of solar simulator mirror cryocontamination
The background and tasks formulation of the study of Solar Simulator collimation mirror cryocontamination in Large Thermal Vacuum Facility are outlined, research methods and experiment procedures are described, experimental relationships obtained are analyzed and practical recommendations are given. The accepted procedure of thermal vacuum tests as a rule defines the sequence of operations for verifying the spacecraft under test without taking into account measures for preventing Solar Simulator collimation mirror contamination and degradation. On the other hand, evacuation procedures is defined for conditions of achieving the required vacuum in the shortest possible time with using the available evacuation equipment at a regime close to the optimum one. Similarly, cryopanel cooling down cyclogram and test object preparation process are not analyzed from the viewpoint of ways of reducing environmental detrimental effects on thermal vacuum facility contamination-sensitive systems. Solar Simulator mirror contamination and its reflective characteristics change results in degradation of solar flux parameters and reduction of simulator continuous operation time. Methods of consideration of optical effects due to mirror surface contamination are actually missing. The effects themselves are not quite understood and data cited in literature as a rule, were obtained under conditions different from real thermal vacuum facility and therefore should be subjected to additional experimental verification. Only in the last few years contamination effect on optical surfaces degradation has been considered with using empirical relations. Mirror reflective properties degradation leads to the increase of Solar Simulator errors. This ultimately has an adverse effect on S/C ground development, schedule and cost of thermal vacuum tests. Besides, the mirror maintenance in operable state becomes more expensive. The present paper is dedicated to the study of Solar Simulator collimation mirror contamination and to the search of ways for improving the mirror design and thermal vacuum test procedure. On the basis of tests performed, recommendations are devised on reducing chamber inner-optical surfaces cryocontamination and degradation.
Effect of pollutant gases on ozone production by simulated solar radiation
Experiments using simulated solar radiation in a chamber, with a controlled atmospheric pressure near 1 atmosphere, were conducted to evaluate O3 production. The effects of CO and H2O were analyzed to determine if the CO and H2O addition could reduce NO destruction of O3. The results show that NO is destroyed while destroying O3.