Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPACE COMMERCIALIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Interplay Between Climate and Urban Expansion on Building Energy Demand in Morocco

Understanding building energy demand is critical for addressing climate uncertainty challenges and ensuring sustainable urban growth. This study develops a building energy demand (BED) model to explore how climate variation and urban expansion affect residential and commercial space heating and cooling demands in Morocco for three scenarios, namely, 2005, 2018, and 2018 + 1.5 °C. The results show that coastal cities have lower heating and cooling needs due to the oceanic influence, while interior cities require significantly higher heating demand per-unit-floorspace. Between 2005 and 2018, urban growth increased total heating and cooling demand by 218.8 GWh, particularly in northern and coastal regions, despite per-unit-floorspace reductions in milder climates and improved building efficiency in 2018. Residential heating remains the dominant energy use, though commercial demand is significant in urban centers. Under the 2018 + 1.5 °C hypothetical scenario, heating demand across Morocco declines by 335.8 GWh compared to 2018, with urban areas amplifying this trend. Meanwhile, cooling demand increases slightly by 44.4 GWh, with major cities experiencing relative increases of up to 50%. These findings highlight a trade-off where reduced winter heating needs are partly offset by increased summer cooling demands in densely urbanized areas. In conclusion, the study identifies key urban hotspots for targeted interventions, emphasizing the need for energy-efficient building designs, climate-adaptive urban planning, and resilient energy management strategies to sustainably address shifting seasonal energy patterns.

Morocco↗

A View from ORNL: Scientific Data Research Opportunities in the Big Data Age

One of the core issues across computer and computational science today is adapting to, managing, and learning from the influx of "Big Data". In the commercial space, this problem has led to a huge investment in new technologies and capabilities that are well adapted to dealing with the sorts of human-generated logs, videos, texts, and other large-data artifacts that are processed and resulted in an explosion of useful platforms and languages (Hadoop, Spark, Pandas, etc.). However, translating this work from the enterprise space to the computational science and HPC community has proven somewhat difficult, in part because of some of the fundamental differences in type and scale of data and timescales surrounding its generation and use. We describe a forward-looking research and development plan which centers around the concept of making Input/Output (I/O) intelligent for users in the scientific community, whether they are accessing scalable storage or performing in situ workflow tasks. Much of our work is based on our experience with the Adaptable I/O System (ADIOS 1.X), and our next generation version of the software ADIOS 2.X [1].

Klasky, Scott↗

Better Buildings Neighborhood Program: BetterBuildings Lowell (Final Report)

The City of Lowell set four goals at the beginning of the Better Buildings Neighborhood Program: 1. Improve the Downtown Historic Park District’s Carbon Footprint 2. Develop a sustainable and replicable model for energy efficiency in historic buildings 3. Create and retain jobs 4. Promote multi-stakeholder partnerships. The City of Lowell, MA was awarded $5 million in May 2010 to conduct energy efficiency retrofits within the downtown National Historical Park (NHP). The City’s target was to complete retrofits in 200,000 square feet of commercial space and create 280 jobs, while adhering to the strict historical preservation regulations that govern the NHP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

City of Phoenix - Energize Phoenix Program

Energize Phoenix (EPHX) was designed as an ambitious, large-scale, three-year pilot program to provide energy efficiency upgrades in buildings, along Phoenix’s new Light Rail Corridor – part of a federal effort to reduce energy consumption and stimulate job growth, while simultaneously reducing the country’s carbon footprint and promoting a shift towards a green economy. The program was created through a 2010 competitive grant awarded to the City of Phoenix who managed the program in partnership with Arizona State University (ASU), the state’s largest university, and Arizona Public Service (APS), the state’s largest electricity provider. The U.S. Department of Energy (DOE) Better Buildings Neighborhood Program (BBNP) and the American Recovery and Reinvestment Act (ARRA) of 2009 provided $25M in funding for the EPHX program. The Light Rail Corridor runs through the heart of downtown Phoenix, making most high-rise and smaller commercial buildings eligible to participate in the EPHX program, along with a diverse mix of single and multi-family residential buildings. To ensure maximum impact and deeper market penetration, Energize Phoenix was subdivided into three unique parts: i. commercial rebate program, ii. commercial financing program, and iii. residential program Each component was managed by the City of Phoenix in partnership with APS. Phoenix was fortunate to partner with APS, which already operated robust commercial and residential rebate programs within its service territory. Phoenix tapped into the existing utility contractor network, provided specific training to over 100 contracting firms, and leveraged the APS rebate program structure (energy efficiency funding) to launch the EPHX commercial and residential rebate programs. The commercial finance program was coordinated and managed through a contract with National Bank of Arizona, NBAZ, which also provided project capital leveraging EPHX finance funds. Working in unison, approved contractors jointly produced more than 161,000 labor hours in pursuit of EPHX goals over the life of the project. Labor hours were spread among electricians, heating, ventilating and air-conditioning (HVAC) technicians, marketing professionals, engineers, sales, and administrative support staff across the approved contractor workforce. Program participants received both the utility rebate along with the EPHX rebate, and depending on project size and utility rebate structure some projects resulted in low to no-cost upgrades for customers. Phoenix also partnered with ASU, a grant sub-recipient, to leverage the institution’s expertise in research and data analysis. In this partnership, ASU accepted marketing responsibilities for the grant and partnered with DRA Communications (DRA), a Phoenix-based marketing firm, to create and communicate the message out to the marketplace. The EPHX program has completed its energy upgrade activities. A review of the work completed by ASU revealed that the EPHX program substantially exceeded the program’s stated goals by retrofitting/upgrading over 33 million sq ft of commercial space (30 million sq ft goal exceeded by 11%) and 2,014 residential units (1,700 unit goal exceeded by 18%) along the Light Rail Corridor. The program helped stimulate economic growth by adding $31million to the local economy and enhanced an already robust energy efficiency contractor network. This contractor network will continue to promote utility energy incentives to sustain energy efficiency upgrade activities in the future. Finally, EPHX helped reduce participants annual energy consumption by 135 million kilowatt-hour (kWh) translating into over $12.5 million of annual energy cost avoidance for the community. This also resulted in projected payback period of 4.5 years for total investment by all parties and reduced greenhouse gas emissions by over 95,000 metric tons of carbon dioxide equivalent (CO2e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

La Reduccion Gradual de Refrigerantes de Hidrofluorocarburos y el Acondicionamiento de Espacios Comerciales: Guia para la Transicion

You may be aware of the hydrofluorocarbon (HFC) phasedown, but the details and its impact on your operations may still be unclear. Or perhaps this is the first you're hearing about the phasedown. In either case, this guide provides information to aid conversations with facility managers and engineers and provides an explanation of how the phasedown affects equipment in commercial buildings. It also includes actions you and your organization can take now to properly plan and prepare. This is the Spanish translation of NREL/FS-5500-85155: The Hydrofluorocarbon Phasedown and Commercial Space Conditioning: A Guide to the Transition.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Primer for the talk ""Outside of Normal Operating Conditions: Using Commercial Hardware in Space Computing Platforms for Ubiquitous Sensing

Over the past decade field-programmable gate arrays (FPGAs) have been useful in speeding up digital signal processing (DSP) algorithms, and FPGA implementations can be orders of magnitude faster than microprocessor implementations. As many commercial and national security satellites are DSP-oriented, many organizations have started using commercial FPGAs to process data closer to the sensor. Using commercial technology successfully in this environment has lead to new research into fault tolerance and resilience.

97 MATHEMATICS AND COMPUTING↗

Outside Of Normal Operating Conditions: Using Commercial Hardware In Space Computing Platforms For Ubiquitous Sensing

Over the past decade field-programmable gate arrays (FPGAs) have been useful in speeding up digital signal processing (DSP) algorithms, and FPGA implementations can be orders of magnitude faster than microprocessor implementations. As many national security satellites are DSP-oriented, many organizations have started using commercial FPGAs to process data closer to the sensor. Using commercial technology successfully in this environment has lead to new research into fault tolerance and resilience.

97 MATHEMATICS AND COMPUTING↗

Thermal Energy Storage in Commercial Buildings

Space heating and cooling account for as much as 40% of energy used in commercial buildings. Aligning this energy consumption with renewable energy generation through practical and viable energy storage solutions will be pivotal in achieving 100% clean energy by 2050. Integrated on-site renewable energy sources and thermal energy storage systems can provide a significant reduction of carbon emissions and operational costs for the building owner.

buildings energy storage↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Application of Schema Based Occupant-Centric Building Performance Metrics

Occupant behavior can significantly influence the operation and performance of buildings. Many occupant-centric key performance indicators (KPIs) rely on having accurate counts of the number of occupants in a building, which is very different to how occupancy information is currently collected in the majority of buildings today. To address this gap, the authors develop a standardized methodology for the calculation of percent space utilization for buildings, which is formulated with respect to two prevalent operational data schemas: the Brick Schema and Project Haystack. The methodology is scalable across different levels of spatial granularity and irrespective of sensor placement. Moreover, the methods are intended to make use of typical occupancy sensors that capture presence level occupancy and not counts of people. Since occupant-hours is a preferable metric to use in KPI calculations, a method to convert between percent space utilization and occupant-hours using the design occupancy for a space is also developed. The methodology is demonstrated on a small commercial office space in Boulder, Colorado using data collected between June 2018 and February 2019. A multiple linear regression is performed that shows strong evidence for a relationship between building energy consumption and percent space utilization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in China

This study seeks to provide policymakers and other stakeholders with actionable information towards a road map for reducing energy consumption cost-effectively. We focus on individual end use equipment types (hereafter referred to as appliance groups) that might be the subject of policies - such as labels, energy performance standards, and incentives - to affect market transformation in the short term, and on high-efficiency technology options that are available today. As the study title suggests, the high efficiency or Business Case scenario is constructed around a model of cost-effective efficiency improvement. Our analysis demonstrates that a significant reduction in energy consumption and emissions is achievable at net negative cost, that is, as a profitable investment for consumers. Net savings are calculated assuming no additional costs to energy consumption such as carbon taxes. Savings relative to the base case as calculated in this way is often referred to as 'economic savings potential'. Chinese energy demand has grown dramatically over the last few decades. While heavy industry still plays a dominant role in greenhouse gas emissions, demand from residential and commercial buildings has also seen rapid growth in percentage terms. In the residential sector this growth is driven by internal migration from the countryside to cities. Meanwhile, income in both urban and rural subsectors allows ownership of major appliances. While residences are still relatively small by U.S. or European standards, nearly all households own a refrigerator, a television and an air conditioner. In the future, ownership rates are not expected to grow as much as in other developing countries, because they are already close to saturation. However, the gradual turnover of equipment in the world's largest consumer market provides a huge opportunity for greenhouse gas mitigation. In addition to residences, commercial floor space has expanded rapidly in recent years, and construction continues at a rapid pace. Growth in this sector means that commercial lighting and HVAC will play an increasingly important role in energy demand in China. The outlook for efficiency improvement in China is encouraging, since the Chinese national and local governments have implemented significant policies to contain energy intensity and announced their intention to continue and accelerate these. In particular, the Chinese appliance standards program, first established in 1989, was significantly strengthened and modernized after the passage of the Energy Conservation Law of 1997. Since then, the program has expanded to encompass over 30 equipment types (including motor vehicles). The current study suggests that, in spite of these efforts, there is significant savings to be captured through wide adoption of technologies already available on the Chinese market. The approach of the study is to assess the impact of short-term actions on long-term impacts. 'Short-term' market transformation is assumed to occur by 2015, while 'long-term' energy demand reduction impacts are assessed in 2030. In the intervening years, most but not all of the equipment studied will turn over completely. Early in 2011, the Chinese government announced a plan to reduce carbon dioxide emissions intensity (per unit GDP) by 16% by 2015 as part of the 12th five year plan. These targets are consistent with longer term goals to reduce emissions intensity 40-45% relative to 2005 levels by 2020. The efforts of the 12th FYP focus on short-term gains to meet the four-year targets, and concentrate mainly in industry. Implementation of cost-effective technologies for all new equipment in the buildings sector thus is largely complementary to the 12th FYP goals, and would provide a mechanism to sustain intensity reductions in the medium and long term. The 15-year time frame is significant for many products, in the sense that delay of implementation postpones economic benefits and mitigation of emissions of carbon dioxide. Such delays would result in putting in place energy-wasting technologies, postponing improvement until the end of their service life, or potentially resulting in expensive investment either in additional energy supplies or in early replacement to achieve future energy or emissions reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Efficient, Responsive, and Resilient Buildings: Collaboration Between the United States and India

The United States and India have among the largest economies in the world, and they continue to work together to address current and future challenges in reliable electricity supply. The acceleration to efficient, grid-responsive, resilient buildings represents a key energy security objective for federal and state agencies in both countries. The weaknesses in the Indian grid system were manifest in 2012, in the country’s worst blackout, which jeopardized the lives of half of India’s 1.2 billion people. While both countries are investing significantly in power sector reform, India, by virtue of its colossal growth rate in commercial energy intensity and commercial floor space, is better placed than the United States to integrate and test state-of-art Smart Grid technologies in its future grid-responsive commercial buildings. This paper presents a roadmap of technical collaboration between the research organizations, and public-private stakeholders in both countries to accelerate the building-to-grid integration through pilot studies in India.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The BayREN Integrated Commercial Retrofits (BRICR) Project: An Introduction and Preliminary Results

BayREN Integrated Commercial Retrofits (BRICR) is a DOE-funded project which aims to enhance the capacity of energy efficiency programs to recruit participants, develop retrofits, and measure outcomes in small and medium-sized commercial buildings, a sector notoriously hard to reach and expensive to serve, that accounts for 2/3 of US commercial floor space. To address these barriers, BRICR leverages existing incentives, financing, data, and open source software to facilitate two paths for comprehensive improvements: a deep energy retrofit, or serial upgrades integrated into capital improvement and maintenance cycles. BRICR is developing an integrated workflow for iterative energy modeling of commercial buildings for city energy program managers and auditors - starting with mass building-scale simulation based on public records and proceeding through audit, retrofit, and measurement and verification stages. BRICR builds on existing tools including LBNL’s CBES, NREL’s OpenStudio, PNNL’s Audit Template, and DOE’s BuildingSync and SEED PlatformTM. At each stage, BRICR uses available information to inform simulations (starting with public records but iteratively augmented with observations from energy program staff) to improve the quality of the models that inform decision making. This paper presents initial results from energy models of 1699 office and retail buildings in San Francisco. Building stock data from public records were translated to create a BuildingSync file for each building which was stored in SEED. Each BuildingSync file was then translated to multiple OpenStudio Workflow files for EnergyPlus simulation to estimate energy savings of energy conservation measures (ECM). Energy savings predictions for each ECM were written back to an updated BuildingSync file for each building and re-uploaded to SEED. The distribution of baseline energy simulations was calibrated against the publicly disclosed distribution of energy benchmarking data to increase confidence in results.

Piette, M↗

Remediation of Occupied Commercial Property Subject to Widespread Radium-226 Contamination: Update from WM2012 Paper - 16652

Amec Foster Wheeler was contacted by a company that managed commercial office space. High Rn-222 measurements had been observed throughout the facility and the landlord had been advised to commission a radiological survey of the site. The site had been purchased by the client in the 1990's. Initial desk studies found that the building had operated for around 50 years as a compass factory. Non-intrusive investigation identified widespread Ra-226 contamination. Ra-226 was found in the fabric of the building, in attic spaces, buried under floor boards and underlying car parks. Intrusive investigation was undertaken to estimate volume(s) of waste, waste categories, activity concentrations and the total inventory of radioactive materials on site. This work identified the presence of 180 GBq of Ra-226 on site. A programme of work is currently underway to remediate the site tackling areas posing the greatest risk to site occupants as a priority. We have worked closely with Regulators, our client, and tenants, to decontaminate the fabric of the building whilst areas of the building remain occupied. Early decontamination works identified that radon levels within the building were stubbornly high despite the removal of radium contamination. An independent radon source was suspected. A contaminated drain was discovered leading to a blocked-off river race running under the old mill building. A significant quantity of radium contaminated sludge was identified within the river race. This was believed to be the source of the excessive radon concentrations within the building. The paper will present work undertaken to investigate and remediate the inventory of sludge from beneath the building. It will describe the operational difficulties of working within a dynamic environment impacted by high dose rates, high radon concentrations, water ingress and waste retrieval challenges. The paper will present the radiological and environmental impacts of the work and detail the achieved end points. This was a challenging project working in confined spaces impacted by physical and radiological constraints. The remedial action undertaken significantly reduced radon concentrations in the building metres above the river race. It also significantly reduced the likelihood of radium contamination being mobilised into the river and the wider environment. The achieved end point permitted the building to return to uncontrolled commercial use. The end point achieved within the river race will ensure a safe working environment for future regular structural survey work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗