Development of Low-Toxicity Wastewater Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Adam, Niklas↗

Development of Low-Toxicity Wastewater Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization was an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater was two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort was to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-milliliter volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Mitchell, Julie L.↗

Swift BAT Instrument Thermal Control System Recovery after Spacecraft Safehold in August 2007

The Swift mission Burst Alert Telescope (BAT) Detector Array thermal control system includes two propylene loop heat pipes (LHPs), eight ammonia constant conductance heat pipes (CCHPs), a radiator that has AZ-Tek's AZW-LA-II low alpha white paint, and precision heater controllers that have adjustable set points in flight. The Power Converter Box (PCB) and Image Processor Electronics (IPE) boxes (a primary and a redundant) of the BAT have Z93P white paint radiators. Swift was successfully launched into orbit on November 20, 2004. The spacecraft (S/C) was placed into a safehold mode on August 10, 2007 after an anomaly on inertial reference unit (IRU) #3. It was returned to inertial pointing on August 16 and instrument power up followed. This paper presents a thermal assessment of the BAT instrument thermal control system (TCS) shut down and recovery as a result of the S/C safehold mode. The recovery required starting up the LHPs manually.

Choi, Michael K.↗

Spacecraft oxygen recovery system

Recovery system is comprised of three integrated subsystems: electrochemical carbon dioxide concentrator which removes carbon dioxide from atmosphere, Sabatier reactor in which carbon dioxide is reduced with hydrogen to form methane and water, and static-feed water electrolysis cell to recover oxygen from water.

Quattrone, P. D.↗

Spacecraft oxygen recovery system

A system which uses an electrochemical carbon dioxide concentrator to remove carbon dioxide from the cabin atmosphere and a Sabatier reactor to reduce carbon dioxide with hydrogen to form methane and water is described. Oxygen is recovered from water by means of a static-feed water electrolysis system. The hydrogen thus generated is reused in the carbon dioxide concentrator. The methane is a system byproduct. The CO2 removal reactions and the implementation of the CO2 concentration concept are discussed, and test results are examined.

Quattrone, P. D.↗

Parametric evaluation of a dual-layer dynamic hyperfiltration membrane for recovery of spacecraft wash water at elevated temperature

Performance data consisting of solute rejections and product flux have been measured, as dependent on the operational parameters. These parameters were pressure, 5,000,000 N/sq m (750 psia) to 7,000,000 N/sq m (1040 psia); temperature, 347 K (165 F) to 368 K (200 F); velocity, 1.6 m/s to 10 m/s; and concentration (up to 14x). Tests were carried out on analog wash water. Data taken include rejections of organic materials (TOC), ammonia, urea, and an assortment of ions. The membrane used was a dual-layer, polyacrylic acid over zirconium oxide, deposited in situ on a porcelain ceramic substrate.

Brandon, C. A.↗

Pre- and posttreatment techniques for spacecraft water recovery

The objective was to develop techniques for satisfactory pretreatment of waste water (urine and wash water) prior to recovery by distillation and satisfactory post-treatment of the recovered water and humidity condensate for purification to the high quality necessary for reuse. The effort included literature and laboratory investigations, feasibility evaluations of candidate approaches, and development of conceptual designs for a waste water pretreatment system and a recovered water post-treatment system.

Putnam, David F.↗

Pre- and post-treatment techniques for spacecraft water recovery

Distillation-based waste water pretreatment and recovered water posttreatment methods are proposed for the NASA Space Station. Laboratory investigation results are reported for two nonoxidizing urine pretreatment formulas (hexadecyl trimethyl ammonium bromide and Cu/Cr) which minimize the generation of volatile organics, thereby significantly reducing posttreatment requirements. Three posttreatment methods (multifiltration, reverse osmosis, and UV-assisted ozone oxidation) have been identified which appear promising for the removal of organic contaminants from recovered water.

Putnam, David F.↗

A membrane-based subsystem for very high recoveries of spacecraft waste waters

This paper describes the continued development of a membrane-based subsystem designed to recover up to 99.5 percent of the water from various spacecraft waste waters. Specifically discussed are: (1) the design and fabrication of an energy-efficient reverse-osmosis (RO) breadboard subsystem; (2) data showing the performance of this subsystem when operated on a synthetic wash-water solution - including the results of a 92-day test; and (3) the results of pasteurization studies, including the design and operation of an in-line pasteurizer. Also included in this paper is a discussion of the design and performance of a second RO stage. This second stage results in higher-purity product water at a minimal energy requirement and provides a substantial redundancy factor to this subsystem.

Ray, Roderick J.↗

Progress in the development of the reverse osmosis process for spacecraft wash water recovery.

Research work on ambient- and pasteurization-temperature reverse osmosis processes for wash water recovery in a spacecraft environment is reviewed, and the advantages and drawbacks of each are noted. A key requirement in each case is to provide a membrane of appropriate stability and semipermeability. Reverse osmosis systems intended for such use must also take into account the specific limitations and requirements imposed by the small volume of water to be processed and the high water recovery desired. The incorporation of advanced high-temperature membranes into specially designed modules is discussed.

Pecoraro, J. N.↗

The Apollo spacecraft: A chronology volume 4, 21 January 1966 - 13 July 1974

This final volume of the chronology is divided into three parts: (1) preparation for flight, the accident, and investigation; (2) recovery, spacecraft redefinition, and the first manned flight; and (3) man circles the moon, the Eagle lands, and manned space exploration. Congressional documents, official correspondence, government and contractor reports, memoranda, working papers, and minutes of meetings were used as primary sources. A relatively few entries are based on press releases and newspaper and magazine articles.

Ertel, I. D.↗

PARAWING AERODYNAMICS

Application of the tension structure concept for flexible wings to be used in spacecraft recovery and landing, emphasizing para-wing aerodynamics

FLEXIBLE WING↗

Flexible wings.

Flexible wing development and applications in spacecraft recovery systems, weapon delivery, parachute missions and private planes

Rogallo, F.↗

Experiment K307: Vertebral body strength of rat spinal columns

The effects of space flight on vertebral body bone strength excised were investigated. Comparative biomechanical investigations of vertebral body strength for flight, synchronous, and vivarium rats following spacecraft recovery (R+0), at R+6 and R+29 days post flight recovery are presented. Statistical analyses are presented for the mechanical properties of stiffness, ultimate load, displacement to ultimate load, and energy to ultimate load. At R+0 all of the above properties show that the vertebral body exhibits an increasing susceptibility to fracture. The reduction of bone strength is inhomogeneous and dependent on vertebral level. The R+6 recovery data was inconclusive since it varied above and below the R+0 data. At R+29 ultimate load values showed a statistically significant increase in bone strength approaching that of the vivarium or control group.

Kazarian, L. E.↗