At least 37 records · Page 2

Hydrogen-Maser/Ruby-Maser/Quartz-Crystal Oscillator

Highly stable oscillator suitable for use as 100-MHz frequency standard consists of 100-MHz hydrogen maser combined with double-phase-locked-loop receiver. Generates 100-MHz signal with reduced noise. Contains 100-MHz voltage-controlled quartz-crystal oscillator (VCO) locked in phase to superconducting-cavity maser oscillator (SCMO). SCMO, locks in phase to hydrogen maser, phase-locking receiver and its SCMO/ VCO combination to hydrogen maser. Aspects of SCMO described in previous reports, including "Performance of Superconducting-Cavity Maser" (NPO-18175), NASA Tech Briefs, Vol. 15, No. 6. Performances of component oscillators complement each other.

Wang, Rabi T.↗

Tuned oscillator atomic force microscopy methods and apparatus

Techniques for operating an atomic force microscope, the atomic force microscope comprising a cantilever and configured to image a surface of a sample using a probe tip coupled to the cantilever, the techniques comprising using a controller to perform: obtaining, based on at least one intrinsic parameter of the cantilever, a first quality factor and a first free oscillation amplitude, wherein the cantilever exhibits only one stable oscillation state when oscillating at the first free oscillation amplitude and operating at the first quality factor; and controlling the cantilever to exhibit the only one stable oscillation state by controlling the cantilever to oscillate at a fixed frequency at or near a resonance frequency of the cantilever, oscillate at the first free oscillation amplitude, and operate at the first quality factor.

Schwarz, Udo↗

Prediction of finite pressure oscillations in stable rocket motors

A methodology is outlined for predicting the amplitude of forced vibrations in the acoustic cavity of a solid rocket motor. The equation for forced vibration of the motor cavity acoustic system is written by parallel with the acoustic mechanical analogy. Acoustic and aeroacoustic theory are used to predict the frequency and intensity of vortex systems or turbulence created by passage of the mean flow over geometric discontinuities in the motor port. Approximate methods are presented for coupling the acoustic field due to the flow noise with the chamber acoustics and for summing the effect upon the multiple acoustic modes.

Hessler, R. O.↗

Stable And Oscillating Acoustic Levitation

Sample stability or instability determined by levitating frequency. Degree of oscillation of acoustically levitated object along axis of levitation chamber controlled by varying frequency of acoustic driver for axis above or below frequency of corresponding chamber resonance. Stabilization/oscillation technique applied in normal Earth gravity, or in absence of gravity to bring object quickly to rest at nominal levitation position or make object oscillate in desired range about that position.

Barmatz, Martin B.↗

Long-pulse generation with a stable-relaxation-oscillation Nd:YLF laser

A simple technique for long-pulse (0.2-2 microsec) generation with neodymium lasers has been demonstrated. Under the proper conditions, a normal-mode oscillator, operated in a single transverse mode, produces well-defined relaxation oscillations from which a single subpulse can be isolated for amplification. The characteristic subpulse temporal profile is ideal for saturated amplification without pulse shortening. Data are presented for a Nd:YLF system consisting of an oscillator followed by a 64-nm-long amplifier. Pulse energies in excess of 100 mJ were achieved with a small-signal gain of 630.

Harisson, J.↗

Stable-relaxation-oscillation Nd lasers for long-pulse generation

A simple method to produce high-energy neodymium (Nd) laser pulses with durations on the order of 1 microsec is described. Solid-state lasers can be pumped by relatively short flashlamp pulses to produce well-behaved relaxation oscillations in a diffraction-limited beam. Under the right conditons, each output laser pulse consists of a series of discrete subpulses that are ideally suited to efficient, high-energy amplification. Experimental results for an Nd:LiYF4 oscillator/amplifier system are presented along with numerical simulations. These demonstrate that the system operation is predictable and well behaved. Data are also included for a Nd:glass tunable oscillator based on this concept.

Harrison, James↗

A highly stable crystal oscillator applied to geodetic VLBI experiment

Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55 km baseline using the Crystal oscillator at one end was made in Japan and the obtained error of the baseline vector components were 4 cm, and that of the baseline length was 3 cm. This system may be operated after only 2 hours warm up. These results coincides with those of conventional geodetic Laser ranging and VLBI using a hydrogen maser within the formal error. A VLBI experiment with over 1000 km baselines were carried out successfully from October 1988, and over 11000 km baseline between Japan and Antarctica was carried out successfully in January 1990.

Kiuchi, Hitoshi↗

Mars Global Surveyor Ka-Band Frequency Data Analysis

The Mars Global Surveyor (MGS) spacecraft, launched on November 7, 1996, carries an experimental space-to-ground telecommunications link at Ka-band (32 GHz) along with the primary X-band (8.4 GHz) downlink. The signals are simultaneously transmitted from a 1.5-in diameter parabolic high gain antenna (HGA) on MGS and received by a beam-waveguide (BWG) R&D 34-meter antenna located in NASA's Goldstone Deep Space Network (DSN) complex near Barstow, California. The projected 5-dB link advantage of Ka-band relative to X-band was confirmed in previous reports using measurements of MGS signal strength data acquired during the first two years of the link experiment from December 1996 to December 1998. Analysis of X-band and Ka-band frequency data and difference frequency (f(sub x)-f(sub ka)/3.8) data will be presented here. On board the spacecraft, a low-power sample of the X-band downlink from the transponder is upconverted to 32 GHz, the Ka-band frequency, amplified to I-W using a Solid State Power Amplifier, and radiated from the dual X/Ka HGA. The X-band signal is amplified by one of two 25 W TWTAs. An upconverter first downconverts the 8.42 GHz X-band signal to 8 GHz and then multiplies using a X4 multiplier producing the 32 GHz Ka-band frequency. The frequency source selection is performed by an RF switch which can be commanded to select a VCO (Voltage Controlled Oscillator) or USO (Ultra-Stable Oscillator) reference. The Ka-band frequency can be either coherent with the X-band downlink reference or a hybrid combination of the USO and VCO derived frequencies. The data in this study were chosen such that the Ka-band signal is purely coherent with the X-band signal, that is the downconverter is driven by the same frequency source as the X-band downlink). The ground station used to acquire the data is DSS-13, a 34-meter BWG antenna which incorporates a series of mirrors inside beam waveguide tubes which guide the energy to a subterranean pedestal room, providing a stable environment for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (f(sub ka)= 3.8 f(sub x)). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is presented in Table I for an initial segment of passes.

Morabito, D.↗

Surface acoustic wave stabilized oscillators

A number of 401.2 MHz surface acoustic wave (SAW) controlled oscillators were built and tested. The performance of these oscillators was evaluated for possible use as stable oscillators in communication systems. A short term frequency stability of better than 1 x 10 to the minus 9th power for one second was measured for the SAW oscillators. Long term frequency drift was measured and was found to be dependent on SAW design and packaging. Drift rates ranging from 15 ppm in twenty weeks to 2.5 ppm in twenty weeks were observed. Some further improvement was required. The temperature dependence of the saw oscillators was evaluated and it was concluded that some form of temperature compensation will be necessary to meet the requirements of some communication systems.

Parker, T. E.↗

Composite oscillator systems for meeting user needs for time and frequency

Frequency standards are used in most navigation and telecommunications systems to provide a long term memory of either frequency, phase, or time epoch. From a systems point of view, the performance aspects of the frequency standard are weighed against other systems characteristics, such as overall performance, cost, size, and accessibility; a number of examples are very briefly reviewed. The theory of phase lock and frequency lock systems is outlined in sufficient detail that total oscillator system performance can be predicted from measurements on the individual components. As an example, details of the performance of a high spectral purity oscillator phase locked to a long term stable oscillator are given. Results for several systems, including the best system stability that can be obtained from present commercially available 5-MHz sources, are shown.

Stein, S. R.↗

FY-25 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the system level modeling using RELAP5-3D of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY25. This year’s work focuses on a new tank configuration where the inlet of the tank was lowered in elevation by 45”. The stability boundaries of the NSTF are thoroughly studied and stability maps are constructed based on the stability and the oscillation patterns of the system. Five distinct operational modes are identified, namely single-phase liquid, uniform double peak oscillations, uniform sinusoidal oscillations, stable two-phase flow, and non-uniform oscillations. Next, the riser inlet throttling case of experimental test Run-104 is simulated with the RELAP5 model where good agreement is obtained between the model and the experimental data. The simulation also highlights the effects of backflow of water from the tank to the upper region of the chimney. Additionally, the decay heat removal test of Run-99 is simulated with the RELAP5 model. Comparison is carried out between this run and a similar run with the mid-tank inlet of Run-74 performed in FY22. With the lower tank inlet, the RELAP5 model is able to predict the experimental data more accurately than the previous mid tank inlet configuration. The discrepancy in model prediction accuracy highlights the non-symmetrical spatial effects in the tank that would otherwise be more easily captured with higher fidelity models. Lastly, two exploratory studies are conducted to investigate the behaviors of the NSTF when 1) heating is provided to the downcomer and 2) a bypass channel is added between the horizontal chimney section to the downcomer.

42 ENGINEERING↗

A Micro-Ultrastable Oscillator (micro-US0) for Micro/Nano Sciencecraft

Syntonics LLC developed a prototype micro-Ultra Stable Oscillator (micro-USO) under a Space Base Technology Grant (NAGS-10395). Syntonics conducted the micro-USO Program in two phases. In Phase I, we developed a set of verified analytical models (including thermal, electrical, and control models) for a baseline USO, conducted a series of six technology studies, and built three approx.9OOg prototype units. These prototypes provided a tool for evaluating competing design topologies. In Phase II we prepared the conceptual design of a approx.100-15Og micro-USO.

Source record↗

A 400-Solar-Mass Black Hole in the Galaxy M82

M82 X-1, the brightest X-ray source in the galaxy M82, has been thought to be an intermediate-mass black hole (100 to 10,000 solar masses) because of its extremely high luminosity and variability characteristics, although some models suggest that its mass may be only about 20 solar masses. The previous mass estimates were based on scaling relations that use low-frequency characteristic timescales which have large intrinsic uncertainties. For stellar-mass black holes, we know that the high-frequency quasi-periodic oscillations (100–450 hertz) in the X-ray emission that occur in a 3:2 frequency ratio are stable and scale in frequency inversely with black hole mass with a reasonably small dispersion. The discovery of such stable oscillations thus potentially offers an alternative and less ambiguous means of mass determination for intermediate-mass black holes, but has hitherto not been realized. Here we report stable, twin-peak (3:2 frequency ratio) X-ray quasi-periodic oscillations from M82 X-1 at frequencies of 3.3260.06 hertz and 5.0760.06 hertz. Assuming that we can extrapolate the inverse-mass scaling that holds for stellar-mass black holes, we estimate the black hole mass of M82 X-1 to be 4286 105 solar masses. In addition, we can estimate the mass using the relativistic precession model, from which we get a value of 415663 solar masses.

Pasham, Dheeraj R.↗

Computer study of convection of weakly ionized plasma in a nonuniform magnetic field.

A weakly ionized plasma in a strong and nonuniform magnetic field exhibits an instability analogous to the flute instability in a fully ionized plasma. The instability sets in at a critical magnetic field. To study the final state of the plasma after the onset of the instability, the plasma equations are integrated numerically assuming a certain initial spectrum of small disturbances. In the regime studied, numerical results indicate a final steadily oscillating state consisting of a single finite amplitude mode together with a time-independent modification of the original equilibrium. These results agree with the analytic results obtained by Simon in the slightly supercritical regime. As the magnetic field is increased further, the wavelength of the final oscillation becomes nonunique. There exists a subinterval in the unstable wave band. Final stable oscillation with a wavelength in this subinterval can be established if the initial disturbance has a sufficiently strong component at the particular wavelength.

Shiau, J. N.↗

Remote Sensing and Quantization of Analog Sensors

This method enables sensing and quantization of analog strain gauges. By manufacturing a piezoelectric sensor stack in parallel (physical) with a piezoelectric actuator stack, the capacitance of the sensor stack varies in exact proportion to the exertion applied by the actuator stack. This, in turn, varies the output frequency of the local sensor oscillator. The output, F(sub out), is fed to a phase detector, which is driven by a stable reference, F(sub ref). The output of the phase detector is a square waveform, D(sub out), whose duty cycle, t(sub W), varies in exact proportion according to whether F(sub out) is higher or lower than F(sub ref). In this design, should F(sub out) be precisely equal to F(sub ref), then the waveform has an exact 50/50 duty cycle. The waveform, D(sub out), is of generally very low frequency suitable for safe transmission over long distances without corruption. The active portion of the waveform, t(sub W), gates a remotely located counter, which is driven by a stable oscillator (source) of such frequency as to give sufficient digitization of t(sub W) to the resolution required by the application. The advantage to this scheme is that it negates the most-common, present method of sending either very low level signals (viz. direct output from the sensors) across great distances (anything over one-half meter) or the need to transmit widely varying higher frequencies over significant distances thereby eliminating interference [both in terms of beat frequency generation and in-situ EMI (electromagnetic interference)] caused by ineffective shielding. It also results in a significant reduction in shielding mass.

Strauss, Karl F.↗

Frequency Stability of 1x10(sup -13) in a Compensated Sapphire Oscillator Operating Above 77K

We report on the design and test of a whispering gallery sapphire resonator for which the dominant (WGH (sub n11) ) microwave mode family shows frequency-stable, compensated operation for temperatures above 77 kelvin. The resonator makes possible a new ultra-stable oscillator (USO) capability that promises performance improvements over the best available crystal quartz oscillators in a compact cryogenic package.

Compensated Sapphire Oscillator Oscillators↗

Magnetometer Based on Optoelectronic Microwave Oscillator

proposed instrument, intended mainly for use as a magnetometer, would include an optoelectronic oscillator (OEO) stabilized by an atomic cell that could play the role of a magnetically tunable microwave filter. The microwave frequency would vary with the magnetic field in the cell, thereby providing an indication of the magnetic field. The proposed magnetometer would offer a combination of high accuracy and high sensitivity, characterized by flux densities of less than a picotesla. In comparison with prior magnetometers, the proposed magnetometer could, in principle, be constructed as a compact, lightweight instrument: It could fit into a package of about 10 by 10 by 10 cm and would have a mass <0.5 kg. As described in several prior NASA Tech Briefs articles, an OEO is a hybrid of photonic and electronic components that generates highly spectrally pure microwave radiation, and optical radiation modulated by the microwave radiation, through direct conversion between laser light and microwave radiation in an optoelectronic feedback loop. As used here, "atomic cell" signifies a cell containing a vapor, the constituent atoms of which can be made to undergo transitions between quantum states, denoted hyperfine levels, when excited by light in a suitable wavelength range. The laser light must be in this range. The energy difference between the hyperfine levels defines the microwave frequency. In the proposed instrument (see figure), light from a laser would be introduced into an electro-optical modulator (EOM). Amplitude-modulated light from the exit port of the EOM would pass through a fiber-optic splitter having two output branches. The light in one branch would be sent through an atomic cell to a photodiode. The light in the other branch would constitute the microwave-modulated optical output. Part of the light leaving the atomic cell could also be used to stabilize the laser at a frequency in the vicinity of the desired hyperfine or other quantum transition. The microwave signal from the output of the photodiode would be amplified (if necessary, as explained below) and fed back into the EOM. This system would oscillate if the amplification in the closed loop exceeded the linear absorption of the loop. The microwave amplifier may be unnecessary to sustain stable oscillations, depending on the power of the laser radiation at the photodetector and on particular features of the modulator and optical delay line.

Maleki, Lute↗

Observations of enhanced ion line frequency spectrum during Arecibo ionospheric modification experiment

The Arecibo 430 MHz incoherent scatter radar (ISR) was used to monitor the effects of modifying the ionosphere by a high power HF transmitter feeding the 305 m reflector antenna. When in the ordinary magnetoionic mode parametric instabilities develop in the ionosphere near the reflection level. Manifestations of these instabilities are the strong enhancement of Langmuir oscillations in the direction of the ISR beam at a wavelength of 35 cm and the simultaneous much weaker enhancement of ion oscillations in that direction. The spectral analysis of the enhanced peak with a height resolution of 2.4 km shows that the ionic mode enhancement most often has a double humped frequency spectrum corresponding to up- and down-going ion acoustic waves. The shape of the frequency spectrum is interpreted in terms of a stable oscillation which is driven by a secondary electrostatic field caused by nonlinear interaction of Langmuir waves within a cone centered on the magnetic field and by the scattering of the pump field on stable Langmuir waves travelling along the direction of the ISR.

Hagfors, T.↗