Search NASA⌕ Search

SEARCH · Search NASA

Results for “STAGNATION REGION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Stagnation region gas film cooling: Spanwise angled injection from multiple rows of holes

The stagnation region of a cylinder in a cross flow was used in experiments conducted with both a single row and multiple rows of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio with a freestream to wall temperature ratio approximately equal to 1.7 and R(eD) = 90,000. Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, 58.7 deg from stagnation using a hole spacing ratio of S/d(o) = 5 and 10. Three multiple row configurations were also investigated. Data are presented for a uniform blowing distribution and for a nonuniform blowing distribution simulating a plenum supply. The data for local Stanton Number reduction demonstrated a lack of lateral spreading by the coolant jets. Heat flux levels larger than those without film cooling were observed directly behind the coolant holes as the blowing ratio exceeded a particular value. The data were spanwise averaged to illustrate the influence of injection location, blowing ratio and hole spacing. The large values of blowing ratio for the blowing distribution simulating a plenum supply resulted in heat flux levels behind the holes in excess of the values without film cooling. An increase in freestream turbulence intensity from 4.4 to 9.5 percent had a negligible effect on the film cooling performance.

Luckey, D. W.↗

The influence of jet-grid turbulence on heat transfer from the stagnation region of a cylinder in crossflow

The effect of high-intensity turbulence on heat transfer from the stagnation region of a circular cylinder in crossflow was studied. The work was motivated by the desire to be able to more fully understand and predict the heat transfer to the leading edge of a turbine airfoil. In order to achieve high levels of turbulence with a reasonable degree of isotropy and homogeneity, a jet-injection turbulence grid was used. The jet grid provided turbulence intensities of 10 to 12 percent, measured at the test cylinder location, for downstream blowing with the blowing rate adjusted to an optimal value for flow uniformity. Heat transfer augmentation above the zeroturbulence case ranged from 37 to 53 percent for the test cylinder behind the jet grid for a cylinder Reynolds number range of 48,000 to 180,000, respectively. The level of heat transfer augmentation was found to be fairly uniform with respect to circumferential distance from the stagnation line. Stagnation point heat transfer results (expressed in terms of the Frossling number) were found to be somewhat low with respect to previous studies, when compared on the basis of equal values of the parameter Tu Re(1/2), indicating an additional Reynolds number effect as observed by previous investigators. Consequently, for a specified value of Tu Re(1/2), data obtained with a relatively high turbulence intensity will have a lower value of the Frossling number.

Obrien, J. E.↗

Heat transfer in the stagnation region of the junction of a circular cylinder perpendicular to a flat plate

The heat transfer rate in the stagnation region of the junction of a circular cylinder perpendicular to a flat plate was measured for a range of Reynolds numbers varying from 3.0 x 10 to the 4th to 7.0 x 10 to the 5th and a flow Mach number of 0.14. The measurements were performed in a shock-tube facility using a reflected shockwave technique and thin-film platinum heat gages. The heat flux was measured for both the plate and the circular cylinder. A substantial increase in the heat transfer rate in the junction region was observed. The influence of the cylinder over the flat plate extended beyond 3/4 cylinder diameter for low Reynolds numbers. For high Reynolds numbers the maximum increase in the heat transfer rate was observed to be approximately 100 percent, but for very low Reynolds numbers a maximum increase in the heat flux to the plate by a factor of 5 was observed. The variations in the heat transfer rate to the stagnation point of the cylinder was very small.

Hinckel, J. N.↗

Experimental observations on the relationship between stagnation region flow oscillations and eddy shedding for circular cylinder

Measurements indicate a direct coupling between the dominant frequencies of flow oscillations at the leading-edge stagnation region, laminar-separation unsteadiness, and the vortex shedding. An array of surface mounted, micro-thin hot-films were used to simultaneously determine the state of the boundary layer along the surfaced of a circular cylinder, and vortex shedding was monitored by a hot wire placed in its wake.

Mangalam, S. M.↗

Stagnation region gas film cooling: Effects of dimensionless coolant temperature

An experimental investigation was conducted to mode the film cooling performance for a turbine vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio and dimensionless coolant temperature with free stream-to-wall temperature ratio approximately 1.7 and Re sub D = 90000. the cylindrical test surface was instrumented with miniature heat flux gages and wall thermocouples to determine the percentage reduction in the Stanton number as a function of the distance downstream from injection (x/d sub 0) and the location between adjacent holes (z/S). Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, from stagnation using a hole spacing ratio of S/d = 5. The film coolant was injected with T sub c T sub w with a dimensionless coolant temperature in the range 1.18 or equal to theta sub c or equal to 1.56. The data for local Stanton Number Reduction (SNR) showed a significant increase in SNR as theta sub c was increased above 1.0.

Bonnice, M. A.↗

Stagnation region gas film cooling for turbine blade leading edge applications

An experimental investigation was conducted to model the film-cooling performance for a turbine-vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise-angled coolant holes for a range of the coolant blowing ratio with a freestream-to-wall temperature ratio of about 2.1 and a Reynolds number of 170,000, characteristic of the gas-turbine environment. Data from local heat-flux measurements are presented for coolant-hole injection angles of 25, 35, and 45 deg with the row of holes located at three positions relative to the stagnation line on the cylinder. Results show the spanwise (hole-to-hole) variation of heat-flux reduction due to film cooling and indicate conditions for the optimum film-cooling performance.

Luckey, D. W.↗

Effects of wake passing on stagnation region heat transfer

In the present experimental study, an annular-flow wind tunnel fitted with a spoked-wheel wake generator was used to ascertain both time-averaged and time-resolved effects of wake passing in a cylinder stagnation region; the cylindrical spokes generated wakes simulating those of a turbine inlet guide vanes. The time-averaged heat transfer results obtained indicate an asymmetric heat-transfer coefficient distribution about the stagnation line, with higher heat-transfer coefficients on the side corresponding to the suction side of the turbine blade. Spectra of the hot-film records indicate that vortex-shedding is a major contributor to the unsteady buffeting of the test-cylinder boundary layer at circumferential stations located at both + and -60 deg from the stagnation line, despite making only a minor contribution to the stagnation line itself.

O'Brien, J. E.↗

Simulation of Stagnation Region Heating in Hypersonic Flow on Tetrahedral Grids

Hypersonic flow simulations using the node based, unstructured grid code FUN3D are presented. Applications include simple (cylinder) and complex (towed ballute) configurations. Emphasis throughout is on computation of stagnation region heating in hypersonic flow on tetrahedral grids. Hypersonic flow over a cylinder provides a simple test problem for exposing any flaws in a simulation algorithm with regard to its ability to compute accurate heating on such grids. Such flaws predominantly derive from the quality of the captured shock. The importance of pure tetrahedral formulations are discussed. Algorithm adjustments for the baseline Roe / Symmetric, Total-Variation-Diminishing (STVD) formulation to deal with simulation accuracy are presented. Formulations of surface normal gradients to compute heating and diffusion to the surface as needed for a radiative equilibrium wall boundary condition and finite catalytic wall boundary in the node-based unstructured environment are developed. A satisfactory resolution of the heating problem on tetrahedral grids is not realized here; however, a definition of a test problem, and discussion of observed algorithm behaviors to date are presented in order to promote further research on this important problem.

Gnoffo, Peter A.↗