Search NASA⌕ Search

SEARCH · Search NASA

Results for “STARTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Assessment of Land Surface and Lightning Characteristics Associated with Lightning-Initiated Wildfires

Can we use modeled information of the land surface and characteristics of lightning beyond flash occurrence to increase the identification and prediction of wildfires? Combine observed cloud-to-ground (CG) flashes with real-time land surface model output, and Compare data with areas where lightning did not start a wildfire to determine what land surface conditions and lightning characteristics were responsible for causing wildfires. Statistical differences between suspected fire-starters and non-fire-starters were peak-current dependent 0-10 cm Volumetric and Relative Soil Moisture comparisons were statistically dependent to at least the p = 0.05 independence level for both polarity flash types Suspected fire-starters typically occurred in areas of lower soil moisture than non-fire-starters. GVF value comparisons were only found to be statistically dependent for -CG flashes. However, random sampling of the -CG non-fire starter dataset revealed that this relationship may not always hold.

wildfire↗

Comparison of Intralaminar and Interlaminar Mode-I Fracture Toughness of Unidirectional IM7/8552 Graphite/Epoxy Composite

The intralaminar and interlaminar mode-I fracture-toughness of a unidirectional IM7/8552 graphite/epoxy composite were measured using compact tension (CT) and double cantilever beam (DCB) test specimens, respectively. Two starter crack geometries were considered for both the CT and DCB specimen configurations. In the first case, starter cracks were produced by 12.5 micron thick, Teflon film inserts. In the second case, considerably sharper starter cracks were produced by fatigue precracking. For each specimen configuration, use of the Teflon film starter cracks resulted in initially unstable crack growth and artificially high initiation fracture-toughness values. Conversely, specimens with fatigue precracks exhibited stable growth onset and lower initiation fracture toughness. For CT and DCB specimens with fatigue precracks, the intralaminar and interlaminar initiation fracture toughnesses were approximately equal. However, during propagation, the CT specimens exhibited more extensive fiber bridging, and rapidly increasing R-curve behavior as compared to the DCB specimens. Observations of initiation and propagation of intralaminar and interlaminar fracture, and the measurements of fracture toughness, were supported by fractographic analysis using scanning electron microscopy.

Czabaj, Michael W.↗

Growth stage estimation

Of the three candidate approaches to adjustment of the crop calendar to account for year-to-year weather differences, the Robertson triquadratic unit, a function of a nonlinear function of maximum and minimum temperature and day length, best described the rate of phenological development of wheat. The adjustable crop calendar (ACC) as implemented for LACIE is used to calculate the daily increment of development through six physiological stages of growth. Topics covered include dormancy modeling, the spring restart model, spring wheat starter model, winter starter model, winter wheat starter model, inclusion of the moisture variable, and display of crop stage estimation results. Assessment of the ACC accuracy over the period of LACIE operation indicates that the adjustable crop calendars used provided more accurate information than would have been available using historical norms. The models performed best under the conditions from which they were derived (Canadian spring wheat) and most poorly for the dwarf varieties and Southern Hemisphere applications.

Whitehead, V. S.↗

Evaluation of GLAS Demonstration Model Loop Heat Pipe Thermal Vacuum Performance with Various Fluid Charges

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser a radiator, the other will transport 190 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. This along with some non-ideal flight design compromises, such as a less than ideal charge level for this design concept with a symmetrical secondary wick, lead to inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. This presentation focuses on identifying; the sources of the flight test difficulties by modifying the charge and test setup of the successfully tested Development Model Loop Heat Pipe (DM LHP). While very similar to the flight design, the DM L14P did have several significant difference in design and method of testing. These differences were evaluated for affect on performance by conforming the DM LHP to look more like the flight units. The major difference that was evaluated was the relative fill level of the working fluid within the concentrically design LHP compensation chamber. Other differences were also assessed through performance testing including starter heater size and "hot biasing" of major interior components. Performance was assessed with respect to startup, low power operation, conductance, and control heater power. The results of the testing showed that performance improves as initial charge increases, and when the starter heater is made smaller. The "hot biasing" of the major components did not appear to have a detrimental effect. As a result of test results of the DM LHP, modifications are being made to the flight units to increase the fluid charge and increase the watt-density of the starter heater.

Baker, Charles↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6A1-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 kHz to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. Methods used to reduce the effects of extraneous noises (i.e., machine noises, fretting) are described. A frequency spectrum analyzer was used to characterize the emissions and to evaluate methods used to acquire the signals (i.e., transducer location, bandwidth selection). The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

A potential means of using acoustic emission for crack detection under cyclic-load conditions.

A preliminary investigation was conducted to assess the feasibility of monitoring acoustic emission signals from fatigue cracks during cyclic bend tests. Plate specimens of 6Al-4V titanium, 2219-T87 aluminum, and 18-Ni maraging steel were tested with and without crack starter notches. It was found that significant acoustic emission signals could be detected in the frequency range from 100 to 400 kHz. Cracks emanating from starter notches were monitored by the ultrasonic pulse-echo technique and periodically measured by micro-optical examination. The investigation indicated that it was possible to extract meaningful acoustic emission signals in a cyclic bend machine environment.

Vary, A.↗

Surface-crack shape change in bending fatigue using an inexpensive resonant fatiguing apparatus

An inexpensive device for producing surface cracks of controlled size and shape is described along with results of its use which show how the shape of the surface crack changes as it grows in bending fatigue from a variety of crack starter shapes. The growth pattern for any crack is uniquely defined by the crack starter configuration and appears to be independent of alloy. Shape changes are substantial and all growth curves tend toward a common growth curve. Circular cracks tend to become elliptical with an associated increase in stress intensity factor. This increase accelerates the crack growth rate and proximity to the critical flaw size. Through-cracks produced by the extension of a surface crack in a bending stress field will have length ten times the section thickness. The results demonstrate the necessity of taking into account changing crack shape in the calculation of structural life when bending is a significant component of the stress field.

Pierce, W. S.↗

A fracture specimen for high-temperature testing

A wedge-loaded tapered DCB specimen is proposed for fracture toughness and stable crack growth measurements of ceramic materials at elevated temperatures. The specimen is wedge-loaded by a compression pin seated in the starter notch. By appropriate selection of the specimen's taper and starter notch angle, the stress intensity factor is maintained relatively constant through 50 percent of the test section. Room temperature fracture toughness testings of commercial grade polycrystalline alumina specimens indicate that the crack will run straight for approximately 50 percent of the length of the test section without side grooving. A moderate 10 percent side grooving was sufficient to maintain straight crack extension throughout the entire specimen length.

Kobayashi, A. S.↗

Airstart performance of a digital electronic engine control system in an F-15 airplane

The airstart performance of the F100 engine equipped with a digital electronic engine control (DEEC) system was evaluated in an F-15 airplane. The DEEC system incorporates closed-loop airstart logic for improved capability. Spooldown and jet fuel starter-assisted airstarts were made over a range of airspeeds and altitudes. All jet fuel starter-assisted airstarts were successful, with airstart time varying from 35 to 60 sec. All spooldown airstarts at airspeeds of 200 knots and higher were successful; airstart times ranged from 45 sec at 250 knots to 135 sec at 200 knots. The effects of altitude on airstart success and time were small. The flight results agreed closely with previous altitude facility test results. The DEEC system provided successful airstarts at airspeeds at least 50 knots lower than the standard F100 engine control system.

Licata, S. J.↗

Power Supply For 25-Watt Arc Lamp

Dual-voltage circuitry both strikes and maintains arc. New power supply designed (and several units already in use) that replaces relay/choke combination with solid-state starter. New power supply consists of two main sections. First section (low voltage power supply section) is 84-volt directcurrent supply. Second section (high-voltage starter circuit) is CockroftWalton voltage multiplier. Used as light sources for schlieren, shadowgraph, and other flow-visualization techniques.

Leighty, B. D.↗

Arc lamp power supply using a voltage multiplier

A power supply is provided for an arc discharge lamp which includes a relatively low voltage high current power supply section and a high voltage starter circuit. The low voltage section includes a transformer, rectifier, variable resistor and a bank of capacitors, while the starter circuit comprises several diodes and capacitors connected as a Cockcroft-Walton multiplier. The starting circuit is effectively bypassed when the lamp arc is established and serves to automatically provide a high starting voltage to re-strike the lamp arc if the arc is extinguished by a power interruption.

Leighty, Bradley D.↗

Geoscience Laser Altimeter System (GLAS) Final Test Report of DM LHP TV Testing

Two loop heat pipes (LHPs) are to be used for thermal control of the Geoscience Laser Altimeter System (GLAS), planned for flight in 2001. One LHP will be used to transport 100 W from a laser to the radiator, the other will transport 210 W from electronic boxes to the radiator. In order to verify the LHP design for the GLAS application, an LHP Development Model has been fabricated, and ambient and thermal vacuum tested. Two aluminum blocks of 15 kg and 30 kg, respectively, were attached to the LHP to simulate the thermal masses connected to the heat sources. A 20 W starter heater was installed on the evaporator to aid the loop startup. A new concept to thermally couple the vapor and liquid line was also incorporated in the LHP design. Such a thermal coupling would reduce the power requirement on the compensation chamber in order to maintain the loop set point temperature. To avoid freezing of the liquid in the condenser during cold cases, propylene was selected as the working fluid. The LHP was tested under reflux mode and with adverse elevation. Tests conducted included start-up, power cycle, steady state and transient operation during hot and cold cases, and heater power requirements for the set point temperature control of the LHP. Test results showed very successful operation of the LHP under all conditions. The 20 W starter heater proved necessary in order to start the loop when a large thermal mass was attached to the evaporator. The thermal coupling between the liquid line and the vapor line significantly reduced the heater power required for loop temperature control, which was less than 5 watts in all cases, including a cold radiator. The test also demonstrated successful operation with a propylene working fluid, with successful startups with condenser temperatures as low as 100 C. Furthermore, the test demonstrated accurate control of the loop operating temperature within +/- 0.2 C, and a successful shutdown of the loop during the survival mode of operation.

Baker, Charles↗

Geoscience Laser Altimeter System (GLAS) Instrument: Flight Loop Heat Pipe (LHP) Acceptance Thermal Vacuum Test

Two loop heat pipes (LHPs) are to be used for tight thermal control of the Geoscience Laser Altimeter System (GLAS) instrument, planned for flight in late 2001. The LHPs are charged with Propylene as a working fluid. One LHP will be used to transport 110 W from a laser to a radiator, the other will transport 160 W from electronic boxes to a separate radiator. The application includes a large amount of thermal mass in each LHP system and low initial startup powers. The initial design had some non-ideal flight design compromises, resulted in a less than ideal charge level for this design concept with a symmetrical secondary wick. This less than ideal charge was identified as the source of inadequate performance of the flight LHPs during the flight thermal vacuum test in October of 2000. We modified the compensation chamber design, re-built and charged the LHPs for a final LHP acceptance thermal vacuum test. This test performed March of 2001 was 100% successful. This is the last testing to be performed on the LHPs prior to instrument thermal vacuum test. This sensitivity to charge level was shown through varying the charge on a Development Model Loop Heat Pipe (DM LHP) and evaluating performance at various fill levels. At lower fills similar to the original charge in the flight units, the same poor performance was observed. When the flight units were re-designed and filled to the levels similar to the initial successful DM LHP test, the flight units also successfully fulfilled all requirements. This final flight Acceptance test assessed performance with respect to startup, low power operation, conductance, and control heater power, and steady state control. The results of the testing showed that both LHPs operated within specification. Startup on one of the LHPs was better than the other LHP because of the starter heater placement and a difference in evaporator design. These differences resulted in a variation in the achieved superheat prior to startup. The LHP with the lower superheat was sensitive to the thermal environment around the compensation chamber, while the LHP with the higher superheat (similar in design to DM LHP) was not. In response to the test results the placement of the starter heater will be optimized for the flight instrument testing for higher achieved superheat. This presentation discusses startup behavior, overall conductance of a radiator system, low power operation, high power operation, temperature control stability, and control heater power requirements as measured during this acceptance thermal vacuum test. A brief summary of 'lessons learned' will be included.

Baker, Charles↗

SISO Space Reference FOM - Tools and Testing

The Simulation Interoperability Standards Organization (SISO) Space Reference Federation Object Model (SpaceFOM) version 1.0 is nearing completion. Earlier papers have described the use of the High Level Architecture (HLA) in Space simulation as well as technical aspects of the SpaceFOM. This paper takes a look at different SpaceFOM tools and how they were used during the development and testing of the standard.The first organizations to develop SpaceFOM-compliant federates for SpaceFOM development and testing were NASA's Johnson Space Center (JSC), the University of Calabria (UNICAL), and Pitch Technologies.JSC is one of NASA's lead centers for human space flight. Much of the core distributed simulation technology development, specifically associated with the SpaceFOM, is done by the NASA Exploration Systems Simulations (NExSyS) team. One of NASA's principal simulation development tools is the Trick Simulation Environment. NASA's NExSyS team has been modifying and using Trick and TrickHLA to help develop and test the SpaceFOM.The System Modeling And Simulation Hub Laboratory (SMASH-Lab) at UNICAL has developed the Simulation Exploration Experience (SEE) HLA Starter kit, that has been used by most SEE teams involved in the distributed simulation of a Moon base. It is particularly useful for the development of federates that are compatible with the SpaceFOM. The HLA Starter Kit is a Java based tool that provides a well-structured framework to simplify the formulation, generation, and execution of SpaceFOM-compliant federates.Pitch Technologies, a company specializing in distributed simulation, is utilizing a number of their existing HLA tools to support development and testing of the SpaceFOM. In addition to the existing tools, Pitch has developed a few SpaceFOM specific federates: Space Master for managing the initialization, execution and pacing of any SpaceFOM federation; EarthEnvironment, a simple Root Reference Publisher; and Space Monitor, a graphical tool for monitoring reference frames and physical entities.Early testing of the SpaceFOM was carried out in the SEE university outreach program, initiated in SISO. Students were given a subset of the FOM, that was later extended. Sample federates were developed and frameworks were developed or adapted to the early FOM versions.As drafts of the standard matured, testing was performed using federates from government, industry, and academia. By mixing federates developed by different teams the standard could be tested with respect to functional correctness, robustness and clarity.These frameworks and federates have been useful when testing and verifying the design of the standard. In addition to this, they have since formed a starting point for developing SpaceFOM-compliant federations in several projects, for example for NASA, ESA as well as SEE.

Möller, Björn↗

A Benchmark Example for Delamination Propagation Predictions Based on the Calibrated End-Loaded Split Specimen

A benchmark example based on the Calibrated End-Loaded Split (C-ELS) specimen is developed and used to assess the performance of recently developed delamination propagation capabilities in the Abaqus/Standard finite element code. The C-ELS specimen has the advantage of a longer region of stable delamination propagation compared to the existing mode II benchmark case. The new benchmark example may therefore provide a better assessment tool by enabling more stable crack growth in regions further away from the boundary conditions or load application. First, a benchmark result is created manually using two-dimensional finite element models of the C-ELS specimen with different delamination lengths. Second, the performance of the delamination propagation capabilities in the Abaqus/Standard finite element code are assessed by comparing the results to the benchmark case. Two examples with different starter delamination lengths are studied. A shorter starter length is chosen to create a scenario with unstable delamination propagation. A longer delamination causes stable delamination propagation. Detailed results from three-dimensional analyses with aligned and mis-aligned meshes and two levels of mesh refinement are provided for several permutations of numerical input parameters. In general, good agreement can be achieved between the results obtained from the quasi-static propagation analysis and the benchmark analysis. However, particular non-default settings are found to be most reliable, accurate, and numerically efficient. Numerical artifacts including anomalous unreleased nodes in the crack wake and zig-zag crack fronts occur, and further development of the Abaqus/Standard VCCT propagation may be required. Use of the benchmark case to assess the continuous improvements in one finite element code illustrates the value of establishing benchmark solutions.

delamination↗

Development of a C-ELS Specimen-Based Numerical Benchmark for Mode II Delamination and Assessment of Two VCCT-Based Propagation Strategies

A finite element (FE) benchmark example inspired by the calibrated end-loaded split (C-ELS) specimen is developed and used to assess the performance of delamination propagation capabilities based on linear elastic fracture mechanics (LEFM). The C-ELS specimen has the advantage of a longer region of stable delamination propagation compared to the existing mode II benchmark case. The new benchmark example may therefore provide a better assessment tool by enabling more stable crack growth in regions further away from the boundary conditions or load application. First, a benchmark result is created manually using two-dimensional finite element models of the C-ELS specimen with different delamination lengths. Second, the performance of the virtual crack closure technique (VCCT) delamination propagation capabilities in the Abaqus/Standard®1 FE code and the recently developed Progressive Release eXplicit-VCCT (PRX-VCCT) method are assessed by comparing the results to the benchmark case. Two examples with different starter delamination lengths are studied. A shorter starter length is chosen to create a scenario with unstable delamination propagation. A longer delamination encourages stable delamination propagation. Detailed results from three-dimensional analyses with aligned and misaligned meshes and two levels of mesh refinement are provided. In general, good agreement can be achieved between the results obtained from the quasi-static propagation analysis and the benchmark analysis. Numerical artifacts including anomalous unreleased nodes in the crack wake and zig-zag crack fronts occur for propagation analyses using Abaqus/Standard VCCT. In comparison, continuous, smooth, delamination fronts are observed for PRX-VCCT. The use of the benchmark case to assess different VCCT-based propagation strategies illustrates the value of establishing benchmark cases.

Composite Materials↗

Assessing Flash Characteristics in Lightning-Initiated Wildfire Events Between 1995 and 2020 Within the Contiguous United States

Twenty-six years of lightning data were paired with over 68,000 lightning-initiated wildfire (LIW) reports to understand lightning flash characteristics responsible for ignition in between 1995 and 2020. Results indicate that 92% of LIW were started by negative cloud-to-ground (CG) lightning flashes and 57% were single stroke flashes. Moreover, 62% of LIW reports did not have a positive CG within 10 km of the start location, contrary to the science literature’s suggestion that positive CG flashes are a dominant fire-starting mechanism. Nearly 1/3rd of wildfire events were holdovers, meaning one or more days elapsed between lightning occurrence and fire report. However, fires that were reported less than a day after lightning occurrence statistically burned more acreage. Peak current was not found to be a statistically significant delineator between fire starters and non-fire starters for -CGs but was for positive CGs. Results highlighted the need for reassessing the role of positive CG lightning and subsequently long continuing current in wildfire ignition started by lightning. One potential outcome of this study’s results is the development of real-time tools to identify ignition potential during lightning events to aid in fire mitigation efforts.

Christopher J Schultz↗

Technique for anchoring fasteners to honeycomb panels

Two-piece fastener bushing provides mounting surface for components on a three-inch thick honeycomb structure. Specially constructed starter drill and sheet metal drill permit drilling without misalignment. Tapered knife-edge cutting tool removes honeycomb core material without tearing the adjacent material.

Brown, W. J.↗