Search NASA⌕ Search

SEARCH · Search NASA

Results for “STS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Natural Resources Assessment for the SNS Second Target Station, Oak Ridge, Tennessee

The US Department of Energy’s Oak Ridge National Laboratory (ORNL) is a leading institution in advanced materials, supercomputing, neutrons, and nuclear science. As a research laboratory managed by UT-Battelle, LLC for DOE, ORNL has national priorities in energy, security, and scientific discovery that necessitate facility improvements and expansions. DOE is also committed to environmental stewardship. The laboratory is located on the ~32,000-acre Oak Ridge Reservation (ORR), much of which is categorized as a National Environmental Research Park and a state Wildlife Management Area. DOE works with the Tennessee Wildlife Resources Agency (TWRA), Tennessee Department of Environment and Conservation (TDEC), US Fish and Wildlife Service (USFWS), US Department of Agriculture, and other agencies to serve as an effective steward of the ORR. Accordingly, project managers must conform to environmental regulations, agreements, and policies at the federal, state, and institutional levels. Per 40 CFR (Code of Federal Regulations) 1508.14, potential effects on research and science education on the National Environmental Research Park represent potential impacts of federal actions. Moreover, federal actions that affect the quantity and quality of hunting opportunities and deer reduction harvest on the Oak Ridge Wildlife Management Area must be considered whenever other aspects of the human environment (as defined by NEPA) are affected. The Spallation Neutron Source (SNS) is a premiere facility at ORNL that provides advanced capabilities in neutron scattering to promote new discoveries and research opportunities in material sciences, physics, chemistry, biological sciences, and others. A conceptual design for a Second Target Station (STS) has been in consideration for several years. The STS is intended to complement and enhance existing ORNL capabilities, notably research and exploration of complex materials. The proposed STS will involve development of existing natural areas on the ORR, which might contain sensitive resources that require mitigation or avoidance in accordance with existing policies and regulation. This report summarizes current knowledge of natural and cultural resources within the STS project area. At the time of this report, the proposed STS project consisted of an operations area comprising 55.4 acres (22.4 ha) and a total review area for potential construction comprising ~224 acres (90.6 ha). The review area is located primarily within forested natural areas of the ORR with minor development in the form of power-line rights-of-way and secondary/graveled roads (Figure 1). The primary goal was to evaluate potential effects on sensitive resources that might result from development of the STS. In addition to onthe-ground surveys during summer 2009 and fall 2019 to summer 2020 by ORNL Natural Resources Management Program and Aquatic Ecology Group staff, this report makes use of historical (pre-1995) and contemporary (1995 to present) data from additional confirmed sources (e.g., TDEC). Likewise, forest conditions were compiled primarily from a 2013 forest inventory effort for Forest Management Compartment 17 and supplemented with limited ground observations in 2019. The individuals who obtained and compiled the data that are presented here are familiar with and routinely assess sensitive resources on the ORR.

54 ENVIRONMENTAL SCIENCES↗

First Experiments: New Science Opportunities at the Spallation Neutron Source Second Target Station (abridged)

This brochure is an abridged version of a more comprehensive companion report. DOE proposes to build a Second Target Station (STS) at SNS to produce beams of cold neutrons with world-leading peak brightness at a repetition rate of 15 Hz, providing broad energy/wavelength ranges that can be used simultaneously. Construction of the STS will provide transformative capabilities that allow thousands of users from national laboratories, universities, and industry to address grand scientific challenges [Hemminger 2015], advance energy research, and accelerate industrial innovations through the combination of cold (long-wavelength) neutrons of unprecedented peak brightness and short neutron pulses with broad ranges of usable wavelengths or energy. The STS Project, now in progress at ORNL, will design, construct, install, and commission the facilities and equipment needed to create a world-leading source of cold neutrons of unprecedented peak brightness at SNS. Key aspects of the STS design, including preliminary descriptions of an illustrative suite of eight instruments, are presented in the section “The STS at SNS.” The capabilities offered by the STS instruments (22 when fully built out) will complement those of the FTS and HFIR, providing the United States with unparalleled resources for neutron scattering at the world’s leading high–peak brightness cold neutron source.

43 PARTICLE ACCELERATORS↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

Second Target Station Project: LANSCE WNR Target 2 (Blue Room) Experiment 2022

The Second Target Station (STS) at SNS will address emerging scientific challenges by providing a source of intense, cold neutrons to instruments optimized for this source, using rotating, tungsten target blocks. The STS target will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 108 beam pulses per lifetime. As an R&D activity, the LANSCE WNR Target 2 (blue room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60% of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. Both the LANSCE Proton Storage Ring (PSR) and SNS are short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in < 1 microsecond pulse duration.

43 PARTICLE ACCELERATORS↗

The ORNL Moderator Test Station Science Case

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a re-imagined FTS and the current STS design are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will, for the brightness metric, significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the resulting neutron beams. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Moderator Test Station at ORNL

Oak Ridge National Laboratory (ORNL) hosts two world-leading slow neutron sources, the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), and is currently developing the technical design for a Second Target Station (STS) for the SNS. Upon completion of the STS project, ORNL will be uniquely positioned to optimize each of its three neutron sources, the SNS First Target Station (FTS), the STS, and HFIR, in a complementary way. Among the essential aspects of a reimagined FTS and the current STS concept are high-brightness parahydrogen moderators—moderators which are optimized for high per-unit-area neutron brightness rather than integrated-across-large-area neutron intensity. The high-brightness moderators proposed for the STS will significantly outperform the coupled moderators currently on the FTS for appropriately optimized neutron beamlines, provided the moderating hydrogen is converted to near-equilibrium levels of parahydrogen (approximately 99.8% at 20 K). The original FTS moderators, by contrast, were conservatively designed to be relatively insensitive to the exact ortho:para ratio, with a consequent loss in performance. As a result, a redesign of the FTS moderators assuming fully converted parahydrogen could result in significant performance improvements on the FTS coupled moderators, and more consistent performance over time for all hydrogen moderators. This “parahydrogen problem” is a long-standing challenge for the effective implementation of hydrogen cold moderators at high-power neutron sources. In addition, the development of new moderator concepts, whether based on previously unused materials, structured heterogeneous arrays, or even simply on changes in overall shape and size is significantly restricted at a large-scale production facility intended to use the neutron beams so produced. Accordingly, moderators for production neutron sources are often designed in a very conservative, low-risk fashion, even though this compromises the absolute neutronic performance. Advanced moderator concepts worthy of study include features that could not be tested without redesigning and redeploying the entire existing reflector, shielding, and neutron beamline installation, making such development efforts far more expensive than building a stand-alone test facility. We propose a Moderator Test Station (MTS) at the SNS with which we will verify such performance gains and test new moderator concepts. These concepts include both high-brightness and large-volume parahydrogen moderators, as well as moderators with tailored ortho:para hydrogen levels, heterogeneous moderator concepts such as the convoluted moderator or pelletized moderators, and moderators made of materials like ammonia, ethane, and oxygen clathrates, which have not been widely tested let alone deployed at neutron source facilities.

42 ENGINEERING↗

Optimization of the Second Target Station cold source moderators using an automated workflow

The Second Target Station (STS) at the US Department of Energy’s Oak Ridge National Laboratory is designed to become the world’s highest peak-brightness spallation source of cold neutrons. Successful completion of the STS, which is currently in the preliminary design phase, will provide transformative new capabilities to examine novel materials for future technologies. At STS, neutrons will be generated by spallation reactions in a solid tungsten target. They will be moderated and thermalized in two cold (20 K) para-hydrogen moderators. Careful optimization of these moderators is essential to the project’s success. To find optimal moderator designs, an advanced optimization workflow integrates high-fidelity neutronics calculations using the Monte Carlo N-Particle (MCNP) transport code MCNP6.2 with state-of-the-art optimization algorithms in the Dakota optimization toolkit. For each design iteration, a parametrized solid CAD geometry is generated in Creo and automatically converted into an unstructured mesh geometry by Attila 4MC for the neutronics calculation with MCNP. Iterations repeat until optimal designs are found. Herein this paper presents the results of a sensitivity and optimization study for the cylindrical and tube moderators. Both moderators can be optimized for maximum peak brightness, maximum time-integrated brightness, or any combination between these extremes. Maximum peak brightness is achieved by using smaller optimal dimensions of the moderators, whereas maximum time-integrated brightness is achieved by using larger dimensions. A Pareto front details the designs that optimally balance both brightness metrics. The Pareto front can be found in only 40–110 iterations with 4–5 design parameters when using the efficient global and Pareto-set optimization algorithms in Dakota. Additionally, important engineering constraints can be taken into account, such as the coupling between the cylindrical moderator radius and aluminum vessel wall thicknesses required to ensure structural integrity of the vessels. This interaction has a significant impact on the resulting optimal designs. Our new, highly efficient, fully automated optimization workflow will be used to optimize additional STS components in the future and can be adopted for design and optimization studies at other experimental neutron and accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibrational and electronic properties of Np 2 O 5 from experimental spectroscopy and first principles calculations

High-valence actinide oxides are critical to understanding the behavior of 5f-electrons, yet their structural and electronic properties remain poorly understood due to challenges in synthesis and handling. We report the first Raman spectroscopic study of single-crystalline Np 2 O 5 and the first scanning tunneling spectroscopy (STS) measurement on any neptunium-containing material. Hydrothermally synthesized crystals were structurally verified by X-ray diffraction. Raman spectra revealed sharply resolved vibrational features, including previously unreported low-frequency modes. STS measurements revealed a band gap of 1.5 eV. Density functional theory (DFT) enables vibrational mode assignments, reveals neptunium-dominated low-frequency phonons, oxygen-dominated high-frequency modes, and predicts an indirect band gap of 1.68 eV. This predicted value is in excellent agreement with the experimentally measured STS gap. This combined Raman, DFT, and STS approach provides a robust framework for correlating lattice dynamics and electronic structure in actinide materials, providing benchmark data for Np 2 O 5 , and opening new avenues for probing structure–property relationships in complex f-electron materials.

36 - MATERIALS SCIENCE↗

Thermal confinement and transport in spherical tokamaks: a review

Here, we review the thermal plasma confinement and transport properties observed and predicted in low aspect ratio tokamaks, or spherical tokamaks (STs), which can depart significantly from those observed at higher aspect ratio. In particular, thermal energy confinement scalings show a strong, near linear dependence of energy confinement time on toroidal magnetic field, while the dependence on plasma current is more modest, the opposite of what is seen at higher aspect ratio. STs have revealed a very strong improvement in normalized confinement with decreasing collisionality, much stronger than at higher aspect ratio, which bodes well for an ST-based fusion pilot plant should this trend continue at an even lower collisionality than has already been accessed. These differences arise because of fundamental differences in transport in STs due to the more extreme toroidicity (i.e. reduced region of bad curvature), and to the relatively larger $E_r \times B$ shearing rates, both of which can suppress electrostatic drift wave instabilities at both ion and electron gyroradius scales. In addition, electromagnetic effects are much stronger in STs because they operate at high β T . Gyrokinetic (GK) studies, coupled with low- and high-k turbulence measurements, have shed light on the underlying physics controlling transport. At lower β T , both ion- and electron-scale electrostatic drift turbulence may be responsible for transport. At higher β T , microtearing, kinetic ballooning, and hybrid trapped electron/kinetic ballooning modes increasingly play a role, and they have a much stronger impact in the core of ST plasmas than at higher aspect ratio. Flow shear affects the balance between ion- and electron-scale modes. Non-linear GK simulations find regimes where the electron heat flux decreases with decreasing collisionality, consistent with the experimental global normalized confinement scaling. The ST is unique in that the relatively low toroidal magnetic field allows for localized measurements of electron-scale turbulence, and this coupled with turbulence measurements at ion-scales has facilitated detailed comparisons with GK simulations. These data have provided compelling evidence for the presence of ion temperature gradient and electron temperature gradient turbulence in some plasmas, and direct experimental support for the impact of experimental actuators like rotation shear, density gradient and magnetic shear on turbulence and transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗

Second Target Station High-Fidelity Target Activation Comparison

The development of the Second Target Station (STS) target system at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is well underway. The target system at STS consists of a rotating target disk that contains 21 segments of tungsten clad in tantalum clad in steel. A key aspect of the design of the target system is to account for the delayed heating and material damage caused by the delayed dose from decaying radionuclides. These radionuclides are a product of either spallation reactions or transmutation of the nuclei in the target system. These radionuclides build up in the target system components over the lifetime of the facility, and the radiation that is emitted can deposit energy in the components causing significant component heating and material damage. Monte Carlo N-Particle (MCNP) Version 6.2 transports the various particle species and calculates the spallation products and neutron fluxes throughout the target system. These spallation products and neutron fluxes along with the material definition of each component are relayed to the CINDER2008 transmutation code to calculate the radionuclide inventories and the corresponding decay gamma emission spectra. MCNP6.2 coupled with CINDER2008 is the computational method-of-choice for the analysis discussed in the following sections of this report. The analysis focuses on validating major assumptions in calculating the radionuclide inventory in the STS target system: all of the target segments are fresh, unirradiated material when the protons are incident on the segment, the average of the 21 segments of the target is sufficient to represent a single segment, and that averaging the proton pulse structure over time does not significantly affect the radionuclide inventory. The position-averaged, high-fidelity, and single-tally computational methods are used to validate the assumptions and provide a point of comparison to evaluate how the assumptions impact the radionuclide inventories. A more detailed explanation of the three computational methods is provided in Section 2. The position-averaged and single-tally methods are less computationally expensive when compared with the high-fidelity method where 54,000 individual calculations are needed to calculate 1 hr of STS operation. Section 3 details the comparison of the three methods to show that the assumptions made in the position-averaged method do not significantly impact the radionuclide inventory after 1 hr of operation. The discussions and results in this report are for 1 hr of operation. Due to the computational cost associated with calculating the transmutation and activation using the high-fidelity method, only 1 hr of operation has been calculated. The discrepancies observed after 1 hr of operation are not extrapolated out to longer operational times, and this report does not address how the discrepancies between the computational methods may manifest for longer operational periods.

43 PARTICLE ACCELERATORS↗

Second Target Station Instrument Systems Research and Development Plan

This document describes the research and development (R&D) plan for Second Target Station (STS) instruments and bunker. The R&D program at STS seeks to mitigate risk and develop new technologies that will enhance performance for deployment on the eight instruments that are part of the STS project. Currently, STS is actively developing six of the eight instruments. This document is expected to be revised as the R&D program progresses and activities begin on the remaining two instruments (VERDI and EXPANSE).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concrete Compositions Used in Neutronics Analyses for Design of the Second Target Station Project

The purpose of this letter is to document the concrete compositions used by the Second Target Station (STS) Project Neutronics Group. Members of the Neutronics Group all have access to these compositions in our MCNP Master Model, which is stored on the ORNL GitLab server. It is expected that all STS Neutronics staff members will use these compositions in their analyses, unless all stakeholders agree to an exception. It is impossible to know the detailed composition of concrete before its constituents have been purchased, mixed, and a chemical analysis performed. Therefore, the STS Neutronics Group decided to use the same concrete compositions used by the Neutronics Group at the First Target Station (FTS). Furthermore, this leads to consistency between the analyses performed by the FTS and STS Neutronics Groups. The most important parameter to match between design simulations and construction regarding these concrete compositions is the density. Next in importance is the fraction of iron and hydrogen in the mixture.

43 PARTICLE ACCELERATORS↗

Evaluation of Second Target Station Target Streaming for the Preliminary Design of the Target Assembly

This report documents the analysis of dose rate fields from a combination of two sources stemming from the target system of the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) Second Target Station (STS). This analysis supports the target drive components’ lifetime estimates and conventional facilities’ preliminary design. The two sources detailed in this report are the radiation generated by the proton beam incident on the target and the activated cooling water in the pipes at the top of the target assembly. The analysis considers the STS target system in operational configuration, with all shielding in place. The dose rate fields are calculated in the target drive room and through the target drive room ceiling. This report calculates the thickness necessary for the target drive room’s high-density concrete ceiling to meet the 0.25 mrem/hr dose limit requirement in the high bay directly above the target drive room. In addition to sizing the target drive room ceiling, this report includes details of the dose field surrounding the target drive assembly to estimate the deposited dose in the target drive assembly components resulting from both streaming and decay of activated water. Prompt neutrons and gammas generated by the proton beam incident on the target primarily stream along the gaps between the target assembly and core vessel shielding. Because the models and analysis detailed in this report are based on the STS preliminary design, future analysis is needed to support the STS final design.

43 PARTICLE ACCELERATORS↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗