At least 37 records · Page 2

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Modeling Framework to Predict Melting Dynamics at Microstructural Defects in TNT-HMX High Explosive Composites

Many high explosive (HE) formulations are composite materials whose microstructure is understood to impact functional characteristics. Interfaces are known to mediate the formation of hot spots that control their safety and initiation. Here, to study such processes at molecular scales, we developed all-atom force fields (FFs) for Octol, a prototypical HE formulation comprised of TNT (2,4,6-trinitrotoluene) and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine). We extended a FF for TNT and recasted it in a form that can be readily combined with a well-established FF for HMX. The resulting FF was extensively validated against experimental results and density functional theory calculations. We applied the new combined TNT-HMX FF to predict and rank surface and interface energies, which indicate that there is an energetic driver for coarsening of microstructural grains in TNT-HMX composites. Finally, we assess the impact of several microstructural environments on the dynamic melting of TNT crystal under ultrafast thermal loading. We find that both free surfaces and planar material interfaces are effective nucleation points for TNT melting. However, MD simulations show that TNT crystal is prone to superheating by at least 50 K on subnanosecond time scales and that the degree of superheating is inversely correlated with surface and interface energy. The modeling framework presented here will enable future studies on hot spot formation processes in accident scenarios that are governed by strong coupling between microstructural interfaces, material mechanics, momentum and energy transport, phase transitions, and chemistry.

36 MATERIALS SCIENCE↗

Machine learning accelerated turbulence modeling of transient flashing jets

We report modeling the sudden depressurization of superheated liquids through nozzles is a challenge because the pressure drop causes rapid flash boiling of the liquid. The resulting jet usually demonstrates a wide range of structures, including ligaments and droplets, due to both mechanical and thermodynamic effects. As the simulation comprises increasingly numerous phenomena, the computational cost begins to increase. One way to moderate the additional cost is to use machine learning surrogacy for specific elements of the calculation. This study presents a machine learning-assisted computational fluid dynamics approach for simulating the atomization of flashing liquids accounting for distinct stages, from primary atomization to secondary breakup to small droplets using the Σ - Y model coupled with the homogeneous relaxation model. Notably, the models for thermodynamic non-equilibrium (HRM) and Σ - Y are coupled, for the first time, with a deep neural network that simulates the turbulence quantities, which are then used in the prediction of superheated liquid jet atomization. The data-driven component of this method is used for turbulence modeling, avoiding the solution of the two-equation turbulence model typically used for Reynolds-averaged Navier-Stokes simulations for these problems. Both the accuracy and speed of the hybrid approach are evaluated, demonstrating adequate accuracy and at least 25% faster computational fluid dynamics simulations than the traditional approach. This acceleration suggests that perhaps additional components of the calculation could be replaced for even further benefit. Published under an exclusive license by AIP Publishing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electropolishing-induced topographic defects in niobium: insights and implications for superconducting radio frequency applications

Electropolishing (EP) is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. Here, in this work, the ultimate surface finish of EP was investigated by studying its effect on highly polished Nb samples. EP introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

Hryhorenko, Oleksandr [Thomas Jefferson National A↗

Lower Temperature Annealing of Vapor Diffused Nb₃Sn for Accelerator Cavities

Nb₃Sn is a next-generation superconducting material for the accelerator cavities with higher critical temperature and superheating field, both twice compared to Nb. It promises superior performance and higher operating temperature than Nb, resulting in significant cost reduction. So far, the Sn vapor diffusion method is the most preferred and successful technique to coat niobium cavities with Nb₃Sn. Although several post-coating techniques (chemical, electrochemical, mechanical) have been explored to improve the surface quality of the coated surface, an effective process has yet to be found. Since there are only a few studies on the post-coating heat treatment at lower temperatures, we annealed Nb₃Sn-coated samples at 800 C - 1000 C to study the effect of heat treatments on surface properties, primarily aimed at removing surface Sn residues. This paper discusses the systematic surface analysis of coated samples after annealing at temperatures between 850 C and 950 C.

43 PARTICLE ACCELERATORS↗

Sputter coating of Nb₃Sn into SRF cavity using stoichiometric target

Nb₃Sn has emerged as a leading alternative material due to its higher superconducting critical temperature (Tc) and superheating field (Hsh), promising a viable solution to the intrinsic performance limit currently faced by Nb superconducting radiofrequency (SRF) cavities. We sputter-coated Nb₃Sn inside Nb SRF cavity using a stoichiometric Nb₃Sn tube target in a DC cylindrical magnetron sputter coater. The target was fabricated by growing an estimated >20 μm thick Nb₃Sn layer on a Nb tube via Sn vapor diffusion using Jefferson Lab’s coating system. Approximately 150 nm thick Nb-Sn films were sputter-deposited onto flat Nb samples at positions representing the beam tubes and equator of a 2.6 GHz Nb cavity. Post-deposition annealing at 950 °C for 3 h resulted in the formation of Nb₃Sn. Microstructural analysis of the annealed films was carried out to investigate the morphology and structure of the Nb₃Sn films. Later, a 2.6 GHz Nb SRF cavity was coated with a ~1.2 μm thick sputtered Nb-Sn film using a stoichiometric Nb₃Sn target, followed by annealing. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, indicating the formation of Nb₃Sn. After a light Sn recoating treatment, the cavity achieved a quality factor (Q0) of 6.7E+08 at lower field at 2.0 K.

Accelerator Physics↗

Evaluation of Ceramic Heat Exchanger for Next-Generation Concentrated Solar Power

The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.

14 SOLAR ENERGY↗

Electropolishing-induced topographic defects in niobium: Insights and Implications for SRF

Electropolishing (EP) is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. In this work, the ultimate surface finish of EP was investigated by studying its effect on highly polished Nb samples. EP introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

Lechner, Eric [Thomas Jefferson National Accelerat↗

A Simple Model of the Energy Threshold for Snowball Chambers

Cloud and bubble chambers have historically been used for particle detection, capitalizing on supersaturation and superheating, respectively. Here, we present new results from a prototype snowball chamber, in which an incoming particle triggers the crystallization of a purified, supercooled liquid. We demonstrate, for the first time, simulation agreement with our first results from 5 years ago: the higher temperature of the freezing of water and significantly shorter time spent supercooled compared to the control in the presence of a Cf-252 fission neutron source. This is accomplished by combining Geant4 modeling of neutron interactions with the Seitz nucleation model used in superheated bubble chambers, including those seeking dark matter. We explore the possible implications of using this new technology for GeV-scale WIMP searches, especially in terms of spin-dependent proton coupling, and report the first supercooling of WbLS (water-based liquid scintillator).

47 OTHER INSTRUMENTATION↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Thermal protection barrier

A thermal protection barrier including a base layer having a high melting temperature granular media having free standing granules disposed within the base layer and a distributor grid layer having a plurality of spaced-apart distributors composed of a high melting temperature material disposed adjacent to the base layer. The spaced-apart distributors are dimensioned and configured to provide load bearing support to the thermal protection barrier prior to a breach of the thermal protection barrier and to divide and disperse a superheated flowing mass to the free standing granules of the base layer upon occurrence of a breach. In certain embodiments, the thermal protection barrier is positioned adjacent to a nuclear system such that, upon occurrence of a loss of containment accident, the distributor grid layer is positioned and configured to divide and disperse a superheated flowing nuclear mass to the free standing granules.

61 RADIATION PROTECTION AND DOSIMETRY↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Experimental study of flash boiling spray with isooctane, hexane, ethanol and their binary mixtures

The main goal of this study is to understand the effect of fuel properties on flash boiling sprays using multi-hole injectors. Macroscopic characteristics were investigated using Diffused Backlight Imaging (DBI) and quantified with liquid penetration length and spray angles. Phase Doppler Anemometry (PDA) was applied to measure the droplet size and velocity. Behaviors of spray with three single-component fuels (isooctane, hexane, ethanol) under different ambient pressures (100 kPa, 80 kPa, 50 kPa, 22 kPa) as well as their binary mixtures under different blend ratios (10%, 30%, 85%) were reported and analyzed. The results showed that adding ethanol or hexane to isooctane could both promote flash boiling by increasing the overall vapor pressure thus superheated degree. Under mixing ratios of 10% and 30%, sprays with ethanol blends showed more severe flash boiling comparing with sprays with hexane blends. Shorter liquid penetration and better liquid dispersion have been observed. Comparing with isooctane spray, the droplet size continuously decreased with increasing hexane content due to enhanced breakup and faster vaporization. Sprays with ethanol mixtures showed a different trend. Noticeable droplet size reduction has been observed for spray with 10% ethanol content. However, droplet size did not further decrease with higher blend ratios regardless of higher flash boiling intensity. Such observations indicate severe vaporization inhibition caused by the high latent heat of vaporization of ethanol. For sprays with all test fuels, collapsing occurred when the pressure ratio of ambient pressure to saturation pressure (Rp) dropped below 0.3.

03 NATURAL GAS↗

Experimental study of sprays with isooctane, hexane, ethanol and their binary mixtures under different flash boiling intensities

Here, this work investigated the behaviors of single-component and multi-component sprays under different flash boiling intensities. Isooctane, hexane, ethanol, isooctane-hexane, and isooctane-ethanol mixtures were used as test fuels. The pressure ratio of the ambient pressure over saturation pressure (R p ) was used as the indicator of the superheated degree. Macroscopic characteristics of the sprays under 10 different R p (1.1 to 0.14) were investigated using Diffused Backlight Imaging (DBI). Droplet size, which revealed the spray microscopic characteristics, was also investigated using Phase Doppler Anemometry (PDA). The results showed that ambient pressure reduction led to higher flash boiling intensity, significant spray morphology changes, and smaller droplet size, regardless of the fuel type and blend ratios. Spray collapse was observed for all sprays once R p dropped below 0.3. Spray collapse dramatically increased the liquid penetration length, expanded the near-field spray angle, and reduced the far-field angle for sprays with all the fuels. Fuel properties, such as the latent heat of vaporization, had significant impacts on droplet size distributions, thus altering the liquid penetration length and spray angles. Under similar R p , sprays with high ethanol content generally had larger droplet sizes compared with other fuel sprays due to the high latent heat of vaporization. The larger droplets caused the high ethanol content sprays to be more resistant to the plume trajectory change, resulting in a smaller far-field spray angle variations with changing R p . At R p of 0.28, sprays with the similar latent heat of vaporization have similar droplet sizes, and droplet sizes at different radial locations were also similar to each other.

42 ENGINEERING↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

Hydrodynamic behavior of wrapped coil water heater tank

In this work, a numerical investigation using computational fluid dynamics (CFD) has been carried out to analyze the thermal behavior of a water tank integrated to a heat pump water heating system (HPWH). The heat pump condenser is a long coil wrapped around the water tank and insulated from outside from which heat is transferred from the heat pump cycle into the water stored inside the tank. The simulated water tank has a capacity of about 170 L with the charging inlet located at the bottom segment of the tank and the discharging outlet located at the top segment of the tank like commercially available water heaters. The tank was simulated during charging/discharging process with isothermal boundary condition at the tank wall to represent the majority of the process for refrigerant condensation inside the heat pump condenser (excluding superheated and sub-cooled section). Three flow rates were selected to represent low, medium and high flow pattern. Both mean and turbulent flow properties were calculated and analyzed. Heat transfer mechanisms inside the tank are quantified by calculating Richardson and Péclet numbers to show the relative contribution of driving forces. The calculations show that advection is dominant over diffusion. Mixing factor is calculated and presented. It is found that the rate of increase of mixing is nonlinear with the increase in flow rate. Mixing increased by a factor of four when the flow rate increased by a factor of two.