Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sample processing and analysis methods and apparatus

Sample handling, processing and analysis methods and apparatus are described. According to one aspect, a sample processing method includes providing a sample, providing a reference frame which comprises a plurality of markers arranged in a predefined pattern, wherein individual ones of the markers are uniquely identifiable from others of the markers, and associating the reference frame comprising the markers with the sample. The markers are amenable to human or machine reading and for computational manipulation in some examples.

36 MATERIALS SCIENCE↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Oxygen stable isotopes in the nuclear fuel cycle: Assessment of the potential for determining the fabrication and provenance history of anhydrous and hydrous uranium oxides

Determining the origin and history of interdicted nuclear materials is a central challenge in nuclear forensics. The oxygen stable isotope composition of uranium oxide compounds has emerged as a promising forensic signature, attracting increasing attention since the early 2000s. This review examines analytical techniques for measuring oxygen isotope compositions in uranium oxides and evaluates how the nuclear fuel production cycle introduces or modifies these isotopic signatures. The potential for forensic geolocation is explored through workflows that calibrate the relationship between environmental water oxygen isotopes and those found in uranium oxides. Key strengths and limitations of this approach are assessed, including gaps in knowledge related to isotope fractionation during specific stages of the fuel cycle, and processing facility water inputs. The importance of proper sample handling and storage under inert atmospheres, as well as a deeper understanding of both intra-sample oxygen isotope heterogeneity, and hydrous uranium oxide phase formation, is highlighted for improving the reliability of forensic interpretations. In conclusion, the development of uranium oxide standards with well-characterized δ 18 O values and international collaboration toward consensus on their use are identified as essential steps for advancing the field.

Attribution↗

Development of small particle speciation for nuclear forensics by soft X-ray scanning transmission spectromicroscopy

Synchrotron radiation spectromicroscopy provides a combination of submicron spatial resolution and chemical sensitivity that is well-suited to analysis of heterogeneous nuclear materials. The chemical and physical characteristics determined by scanning transmission X-ray microscopy (STXM) are complementary to information obtained from standard radiochemical analysis methods. In addition, microscopic quantities of radioactive material can be characterized rapidly by STXM with minimal sample handling and intrusion, especially in the case of particulate materials. The STXM can accommodate a diverse range of samples including wet materials, complex mixtures, and small quantities of material contained in a larger matrix. In these cases, the inventory of species present in a sample is likely to carry information on its process history; STXM has the demonstrated capability to identify contaminants and sample matrices. Operating in the soft X-ray regime provides particular sensitivity to the chemical state of specimens containing low-Z materials, via the K-edges of light elements. In this paper, recent developments in forensics-themed spectromicroscopy, sample preparation, and data acquisition methods at the Molecular Environmental Science Beamline 11.0.2 of the Advanced Light Source are described. Results from several initial studies are presented, demonstrating the capability to identify the distribution of the species present in heterogeneous uranium-bearing materials. Finally, future opportunities for STXM forensic studies and potential methodology development are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nanowell-mediated multidimensional separations combining nanoLC with SLIM IM-MS for rapid, high-peak-capacity proteomic analyses

Mass spectrometry (MS)–based analysis of complex biological samples is essential for biomedical research and clinical diagnostics. The separation prior to MS plays a key role in the overall analysis, with separations having larger peak capacities often leading to more identified species and improved confidence in those identifications. High-resolution ion mobility (IM) separations enabled by Structures for Lossless Ion Manipulation (SLIM) can provide extremely rapid, high-resolution separations and are well suited as a second dimension of separation following nanoscale liquid chromatography (nanoLC). However, existing sample handling approaches for offline coupling of separation modes require microliter-fraction volumes and are thus not well suited for analysis of trace biological samples. We have developed a novel nanowell-mediated fractionation system that enables nanoLC-separated samples to be efficiently preconcentrated and directly infused at nanoelectrospray flow rates for downstream analysis. When coupled with SLIM IM-MS, the platform enables rapid and high-peak-capacity multidimensional separations of small biological samples. In this study, peptides eluting from a 100 nL/min nanoLC separation were fractionated into ~?60 nanowells on a microfluidic glass chip using an in-house–developed robotic system. The dried samples on the chip were individually reconstituted and ionized by nanoelectrospray for SLIM IM-MS analysis. Using model peptides for characterization of the nanowell platform, we found that at least 80% of the peptide components of the fractionated samples were recovered from the nanowells, providing up to ~tenfold preconcentration for SLIM IM-MS analysis. The combined LC-SLIM IM separation peak capacities exceeded 3600 with a measurement throughput that is similar to current one-dimensional (1D) LC-MS proteomic analyses.

Dou, Maowei↗

Deconsolidation and Leach Burn Leach of Seven As Irradiated AGR 5/6/7 TRISO Fuel Compacts from Capsules 2, 3, 4, and 5

Seven as-irradiated Advanced Gas Reactor (AGR) 5/6/7 compacts underwent destructive post-irradiation examination via deconsolidation-leach-burn leach at Idaho National Laboratory (INL). The selection of the compacts extended the upper and lower limits of time-average volume-average (TAVA) temperature for compacts that had gone through deconsolidation-leach-burn leach so far. The measured inventories of fission products and actinides in the compact matrix and outer pyrolytic carbon were reported. Results indicated unexpectedly higher rates of fuel kernel leaching compared to compacts from AGR-1 and AGR-2. These failure rates were attributed to damage during post-irradiation sample handling, rather than irradiation itself. AGR-5/6/7 compacts have little or no matrix coverage for some particles at the top and bottom ends of cylindrical fuel compacts, making them more fragile. Sixty particles were randomly sampled from each compact, and the gamma results were reported. Three SiC shells from were identified, one of which showed signs of chemical attack in the high-irradiation temperature compact.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy - 19274

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization method, purge flow rate was determined to be highly correlated with increased response (p=0.023). Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. This method represents a decrease in sample handling and processing over currently standard methods and represents a more amenable method for purgeable mercury analysis in liquid nuclear waste.1 An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly Tank 50 samples. Two samples demonstrated no statistically significant difference (p=0.271, p=0.0811), with one sample biased 30% low to a statistically significant degree (p=0.0432). Large mean uncertainty was present in the results reported by both laboratories (±15% and 40% from SRNL and Eurofins), with no significant difference observed in uncertainty (p=0.934). Across all co-analyzed samples, no significantly difference was observed in precision (p=0.205) or reported values (p=0.352) between SRNL and Eurofins. These results indicate that SRNL-AD may provide data to the customer of statistically similar quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Laser-Driven Pulsed Neutron Sources for Poolside Neutron-based Advanced NDE – A Pathway to LANSCE-like Characterization at INL

A variety of opportunities for characterization of fresh nuclear fuels using thermal (~25meV) and epithermal (~10eV) neutrons have been documented at Los Alamos National Laboratory. They include spatially resolved non-destructive characterization of features, isotopic enrichment, chemical heterogeneity and stoichiometry. The LANSCE spallation neutron source is well suited in neutron fluence and temporal characteristics for studies of fuels. However, recent advances in high power short pulse lasers suggest that compact neutron sources might, over the next decade, become viable at a price point that would permit their consideration for poolside characterization on site at irradiation facilities. In a laser-driven neutron source the laser is used to accelerate deuterium ions into a beryllium target where neutrons are produced. At this time, the technology is new and their total neutron production is approximately four orders of magnitude less than a facility like LANSCE. However, recent measurements on a sub-optimized system demonstrated >10 10 neutrons in sub-nanosecond pulses in predominantly forward direction. The compactness of the target system compared to a spallation target may allow exchanging the target during a measurement to e.g. characterize a highly radioactive sample with thermal, epithermal, and fast neutrons as well as hard X-rays, thus avoiding sample handling. At this time several groups are working on laser-driven neutron production and are advancing concepts for lasers, laser targets, and optimized neutron target/moderator systems. Advances in performance sufficient to enable poolside fuels characterization with LANSCE-like fluence on sample within a decade may be possible. This report describes the underlying physics and state-of-the-art of the laser-driven neutron production process from the perspective of the DOE/NE mission. It also discusses the development and understanding that will be necessary to provide customized capability for characterization of irradiated fuels. Potential operational advantages compared to a spallation neutron source include reduced shielding complexity, reduced energy requirements, and a production target free of fission products. Contributors to this report include experts in laser-driven neutron production (Roth, Fernandez), laser design (Haefner, Siders, Leemans), laser target design (Glenzer), spallation target/moderator design (Mocko), neutron instrumentation and characterization applications (Vogel, Bourke).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On-Line Monitoring and Real-Time Characterization of Low Level Waste and Off-Gas Condensate Samples using Raman Spectroscopy

The demand for Hanford waste property analysis is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward transferring waste to the Hanford Waste Treatment and Immobilization Plant. The analysis of waste includes chemical, radionuclide, and physical property characterizations, with the goal of achieving safe/informed transfer and processing. Waste sampling followed by offline laboratory analysis is the current baseline analytical approach. The addition of field-deployed/in situ instruments has the potential to provide improvements and benefits over offline analysis in the areas of 1) Worker Safety: by reducing the need for sampling and thereby reducing the need for worker interaction with waste during sample handling; 2) Operational Efficiency: by reducing analysis turnaround times and offsetting demand on analytical laboratories; and 3) Accuracy: continuous analysis of a flowing waste stream allows cumulative results to be produced for the batch, which is likely to be more representative than discrete samples of batch properties. This paper describes the development and application of an online monitor to provide chemical characterizations; specifically, Raman spectroscopy is utilized to identify and quantify tank components. Accurate quantification is achieved through the use of chemometric analysis, which can be configured to provide real-time analysis in field deployment settings.

Lines, Amanda M.↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile One-Pot Nanoproteomics for Label-Free Proteome Profiling of 50–1000 Mammalian Cells

Recent advances in sample preparation enable label-free MS-based proteome profiling of small numbers of mammalian cells. However, specific devices are often required to downscale sample processing volume from the standard 50-200 µL to sub-µL for effective nanoproteomics, which greatly impedes the implementation of current nanoproteomics methods by broad proteomics research community. Here we report a facile one-pot nanoproteomics method termed SOPs-MS (Surfactant-assisted One-Pot sample processing at the standard volume coupled with MS) for convenient proteome profiling of 50-1000 mammalian cells. Building upon our recent development of SOP-MS for label-free single-cell proteomics at low µL volume (Commun Bio 2021, 4, 265), we have systematically evaluated its processing volume at 10-200 µL using 100 human cells for robust reproducible nanoproteomic analysis. The processing volume of 50 µL which is in the range of volume for standard proteomics sample preparation, has been selected for easy sample handling with benchtop micropipette. Using the commonly accessible LC-MS platform, SOPs-MS allows for reliable label-free quantification of ~1200-2700 protein groups from 50-1000 MCF10A cells. When applied to small subpopulations of mouse colon crypt cells, SOPs-MS can reveal distinct protein signatures between any two subpopulation cells with identification of ~1500-2500 protein groups for each subpopulation. SOPs-MS may pave the way for routine deep proteome profiling of small numbers of cells as well as low-input samples.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗