Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preventing Supercooling Of Gallium

Principle of heterogeneous nucleation exploited to prevent gallium from supercooling, enabling its use as heat-storage material that crystallizes reproducibly at its freezing or melting temperature of 29 to 30 degrees C. In original intended application, gallium used as heat-storage material in gloves of space suits. Terrestrial application lies in preparation of freezing-temperature reference samples for laboratories. Principle of heterogeneous nucleation also exploited similarly in heat pipes filled with sodium.

Massucco, Arthur A.↗

Development of a Novel Self-Enclosed Sample Preparation Device for DNA/RNA Isolation in Space

Modern biology techniques present potentials for a wide range of molecular, cellular, and biochemistry applications in space, including detection of infectious pathogens and environmental contaminations, monitoring of drug-resistant microbial and dangerous mutations, identification of new phenotypes of microbial and new life species. However, one of the major technological blockades in enabling these technologies in space is a lack of devices for sample preparation in the space environment. To overcome such an obstacle, we constructed a prototype of a DNA/RNA isolation device based on our novel designs documented in the NASA New Technology Reporting System (MSC-24811-1/3-1). This device is self-enclosed and pipette free, purposely designed for use in the absence of gravity. Our design can also be modified easily for preparing samples in space for other applications, such as flowcytometry, immunostaining, cell separation, sample purification and separation according to its size and charges, sample chemical labeling, and sample purification. The prototype of our DNA/RNA isolation device was tested for efficiencies of DNA and RNA isolation from various cell types for PCR analysis. The purity and integrity of purified DNA and RNA were determined as well. Results showed that our developed DNA/RNA isolation device offers similar efficiency and quality in comparison to the samples prepared using the standard protocol in the laboratory.

Zhang, Ye↗

Experimental design of an interlaboratory study for trace metal analysis of liquid fluids

The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique.

Greenbauer-Seng, L. A.↗

Development of In Situ Instruments for Planetary Exploration - Unique Challenges in Design, Development, and Execution

A viewgraph presentation describing in situ instruments for NASA missions is shown. The topics include: 1) In Situ Instrumentation; 2) Planetary Extremes; 3) Mars Surface Environment; 4) Lunar Precursor Mission Environment; 5) Europa Surface Analogue; 6) Other Parameters; 7) Space In Situ Instrumentation still in its Infancy; 8) Needed Capabilities For In Situ Science; 9) Framework For Putting The Pieces Together; 10) The Wild World of Astrobiology; 11) Timeline; 12) Example: MOD; 13) In Situ Sample Analysis Laboratories are more complex; 14) technologies In Situ Sample Analysis Requires Integration of Many Emerging Advanced Concepts; 15) Supporting technologies for In Situ Laboratories; 16) Micro-laboratory example; 17) In Situ Instrument Classes; and 18) Key for Analytical Instrument:Sample Preparation.

In Situ Instrumentation↗

Organic Contamination Baseline Study: In NASA JSC Astromaterials Curation Laboratories. Summary Report

In preparation for OSIRIS-REx and other future sample return missions concerned with analyzing organics, we conducted an Organic Contamination Baseline Study for JSC Curation Labsoratories in FY12. For FY12 testing, organic baseline study focused only on molecular organic contamination in JSC curation gloveboxes: presumably future collections (i.e. Lunar, Mars, asteroid missions) would use isolation containment systems over only cleanrooms for primary sample storage. This decision was made due to limit historical data on curation gloveboxes, limited IR&D funds and Genesis routinely monitors organics in their ISO class 4 cleanrooms.

Calaway, Michael J.↗

Bio-gas production from alligator weeds

Laboratory experiments were conducted to study the effect of temperature, sample preparation, reducing agents, light intensity and pH of the media, on bio-gas and methane production from the microbial anaerobic decomposition of alligator weeds (Alternanthera philoxeroides. Efforts were also made for the isolation and characterization of the methanogenic bacteria.

Latif, A.↗

Cross-linked polyvinyl alcohol films as alkaline battery separators

Cross-linking methods were investigated to determine their effect on the performance of polyvinyl alcohol (PVA) films as alkaline battery separators. The following types of cross-linked PVA films are discussed: (1) PVA-dialdehyde blends post-treated with an acid or acid periodate solution (two-step method) and (2) PVA-dialdehyde blends cross-linked during film formation (drying) by using a reagent with both aldehyde and acid functionality (one-step method). Laboratory samples of each cross-linked type of film were prepared and evaluated in standard separator screening tests. The pilot-plant batches of films were prepared and compared to measure differences due to the cross-linking method. The pilot-plant materials were then tested in nickel oxide - zinc cells to compare the two methods with respect to performance characteristics and cycle life. Cell test results are compared with those from tests with Celgard.

Sheibley, D. W.↗

Cross-linked polyvinyl alcohol films as alkaline battery separators

Cross-linking methods have been investigated to determine their effect on the performance of polyvinyl alcohol (PVA) films as alkaline battery separators. The following types of cross-linked PVA films are discussed: (1) PVA-dialdehyde blends post-treated with an acid or acid periodate solution (two-step method) and (2) PVA-dialdehyde blends cross-linked during film formation (drying) by using a reagent with both aldehyde and acid functionality (one-step method). Laboratory samples of each cross-linked type of film were prepared and evaluated in standard separator screening tests. Then pilot-plant batches of films were prepared and compared to measure differences due to the cross-linking method. The pilot-plant materials were then tested in nickel oxide-zinc cells to compare the two methods with respect to performance characteristics and cycle life. Cell test results are compared with those from tests with Celgard.

Sheibley, D. W.↗

Derivation of mid-infrared (5-25 microns) optical constraints of some silicates and palagonite

This study was initially conceived in order to aid in the interpretation of Martian surface and atmospheric aerosol mineralogy. As a result, the minerals included are biased toward samples which represent hydrated and hydroxylated silicates. Due to their physical particle size, clays and other materials, such as palagonite, cannot be prepared using typical preparation techniques. Yet in some cases, such as for Mars, these are the materials of perhaps the greatest interest. In order to obtain a suitable sample of these less cohesive materials for the laboratory measurements, a KBr pellet die was used and a pellet of the pure sample was prepared. For all clays and the palagonite, a pellet with highly reflective surfaces at visible wavelengths was produced. The reflectivities of all samples were determined, and to derive the optical constants of a materials as a function of wavelength, dispersion analysis was used which describes the real and imaginary indices of refraction as the contributions due to a sum of classical oscillators and relates them via Frensel's equations for non-normal incidence, the the measured near-normal reflectivity. The final values that were determined represent averages of several model fits to each data set using the same number of oscillators by varying the high frequency dielectric constant.

Roush, T. L.↗

From Apollo to the Future, the NASA Curation Model for Engaging the Sample Science Community Maximizes Science on Extraterrestrial Samples

The Astromaterials Acquisition and Curation Office at Johnson Space Center (JSC) has enjoyed a long-term partnership (50 years!) with a broad community of planetary sample scientists. This partnership has enabled the curators of planetary samples to plan for and enact evolving requirements for preservation of sample scientific integrity and for handling and long-term storage. The basis for this relationship is a standing peer review advisory committee composed of leading scientists who are recognized for achievements in sample analysis. The committee and its descendants have brought familiarity with the most relevant scientific investigations and the associated analytical and contamination challenges. Beginning with Apollo, the review committee was charged with oversight of curatorial operations and with ensuring fair access to samples. As additional samples from other planetary bodies were acquired, the committee evolved, taking on new responsibilities, reflected in committee name changes. However, oversight of curatorial operations and fair allocation of samples remain basic responsibilities. Committee recommendations are sent to the NASA Headquarters Discipline Scientist for approval. To minimize conflict of interest and maximize fair access, the rules governing the make-up of the committee is structured. Systematic rotation of leadership and staggered terms of membership allow the committee to retain expertise while bringing in fresh ideas. The first peer review committee was called the Lunar Sample Analysis and Planning Team (LSAPT) and was formalized in early 1968 with about 15 members. Their function was to review a) the equipment and procedures used in the new Lunar Receiving Laboratory (LRL); b) the proficiency and capability of the LRL staff; c) the sequence of sample analysis and allocation after quarantine release; and d) the findings of the Preliminary Examination Team (PET). According to LSAPT member Gerald Wasserburg, one of the first issues they faced was deciding whether to have most of the sample analyses performed in house at the LRL or to distribute samples to members of the scientific community. LSAPT concluded that the major scientific investigations should be carried out externally to the LRL by scientists chosen for their expertise in specific disciplines. Further they recommended that the PET's basic characterization of samples be circulated to the broad scientific community. LSAPT set its own agenda, paid attention to facility details, closely monitored the move of samples from the LRL to the interim curatorial facility in 1973, and was active in inspecting curation facilities. Between 1975 and 1979, a Facility Subcommittee of LSAPT oversaw the design and construction of a permanent facility for preservation of lunar samples. The result was an outstanding facility still in use today. In 1977, a separate peer review committee, the Meteorite Working Group (MWG), was formed to evaluate requests for new meteorites then being collected in Antarctica under what would in 1980 become a 3-agency agreement (National Science Foundation, NASA, Smithsonian Institution). By 1979, after lunar samples were moved into the new permanent facility, the vacated gloveboxes and laboratory were prepared for meteorite curation. Recognizing that LSAPT had been helpful in setting up the JSC curatorial facility for Antarctic meteorites, JSC recommended the review committee be given expanded duties, including advice on curation and analysis of materials from other planetary bodies and the name be changed to Lunar and Planetary Sample Team (LAPST). In 1993, LAPST was renamed the Curation and Analysis Planning Team for Extraterrestrial Materials (CAPTEM) to reflect additional functions. CAPTEM is chartered to be (1) a community-based, interdisciplinary forum for discussion and analysis of matters concerning the collection and curation of extraterrestrial samples, including planning future sample return missions and (2) a standing review panel, charged with evaluating proposals requesting allocation of all extraterrestrial samples contained in NASA collections. Efficiency and flexibility are gained through use of subcommittees, both ad hoc and standing. Transition of the MWG to a subcommittee of CAPTEM was completed in 2017. Today subcommittees review allocation requests for lunar samples, Antarctic meteorites, cosmic dust, Stardust cometary samples, Genesis solar wind samples, and samples returned from asteroids. Other subcommittees address facilities, informatics, and micro-cratered substrates. Planetary samples have been sent to research teams in over 30 countries world-wide. The expertise in the care and fair distribution of astromaterials by NASA using this model spans generations of planetary sample scientists and is a valuable resource to be tapped for future sample returns - OSIRIS-REx, Hayabusa 2, and Mars 2020.

Allton, Judith↗

Opacification of high temperature fibrous insulation

A study was conducted to determine the merits of adding particulate materials to silica fiber felts to increase their resistance to the passage of thermal radiation. Laboratory samples containing 5, 10, and 15 percent of chromium oxide, silicon carbide, and titanium dioxide were prepared and evaluated in accordance with ASTM C-518 thermal conductivity test method at 425 C (800 F) mean temperature. The titania particles averaging 3-4 micrometers in diameter were found to be the most effective. This was followed by a short plant run, in order to confirm the initial results on the laboratory samples. These samples were tested according to ASTM C-201 High Temperature Calorimeter from 93 C to 760 C (200 F to 1400 F) mean temperature. The ten percent by weight of titania resulted in an optimum effectiveness, and reduced the conductivity over 20% at 760 C (1400 F).

Miller, W. C.↗

New Hayabusa2 and OSIRIS REx Curation Facilities at Nasa Johnson Space Center

Asteroids are made up of rocky material that is left over from the formation of our solar system [1]. This material holds the key to unlocking information about the history of the planets and our sun. Hayabusa2 and OSIRIS-REx are two sample return missions that have collected rocky material from carbonaceous asteroids which are rich in water, carbon, and organic compounds [1]. Hayabusa2 is a spacecraft that collected samples from asteroid Ryugu launched by the Japan Aerospace Exploration Agency (JAXA). Samples were returned to Earth in December 2020 and 10 percent of the collected material is currently housed in a state-of-the-art laboratory at NASA Johnson Space Center (JSC) dedicated to Ryugu material [1]. OSIRIS-REx is a spacecraft launched by NASA that collected samples from asteroid Bennu. The samples are on their journey to Earth and will arrive in September 2023. They will be stored in a separate cleanroom dedicated to Bennu material. From these two missions, scientists will examine dust particles and rocky material to research clues on how the early solar system formed and how life began [2]. Because these samples are so precious and rare, it is important to keep them free from Earth contamination. In September of 2020, a massive construction project began to provide curation facilities to meet the needs of two incoming asteroid collections, Hayabusa2 and OSIRIS-REx. Despite numerous setbacks caused by the coronavirus pandemic, these facilities have been completed in the fall of 2021. Some of these setbacks included strict PPE requirements, keeping safe working distances as well as access to the facilities as NASA was operating under a Stage 3 condition in response to the pandemic. These facilities will provide curation laboratories to safely house the precious asteroid samples as well as facilities to manipulate samples, do sample preparation and process samples into and out of the labs for future studies by the scientific community. The lab suite consists of several different rooms including an initial anteroom (ISO 7), a staging area (ISO 7), two gowning areas (one for OSIRIS-REx and one for Hayabusa2; both ISO 6)), the Haybusa2 Curation Laboratory (ISO 5), the OSIRIS-REx Curation Laboratory (ISO 5), an ultramicrotomy laboratory (ISO 7) and a thin section laboratory (not a cleanroom). To maintain cleanliness levels necessary for these lab spaces quarterly to monthly Balazs organic and inorganic sampling has been conducted on a regular basis before, during and after the construction project to monitor the cleanliness levels in the new labs that will house the asteroid samples. These new facilities feature a Ruuvi (Grafana) monitoring system that measures temperature, humidity, and pressure of the lab suite. This is a small puck shaped sensor that sends signals to the Grafana cloud where the data can be plotted and set up on dashboards within the lab suite. These sensors are easy to set up and install and they run off a cell battery that is good for 3-5 years before needing replacement. This system can deliver text messages and emails to the appropriate personnel when values fall outside of set limits. In addition to the monitoring system, this new lab suite features viewing windows from several different locations and sliding motion censored doors. We have obtained some state-of-the-art equipment to outfit the lab spaces (desiccators, microscopes, ultramicrotome) and are in the process of outfitting the suite with additional items such as: nitrogen gloveboxes, additional desiccators, micromanipulators, etc. The Hayabusa2 samples provided to NASA by JAXA included 23 millimeter sized grains and 4 containers with finer material. OSIRIS-REx is expected to return as much as 400 grams of asteroid Bennu. Samples will be stored in a nitrogen glove box and separated into nitrogen sealed transfer containers. Small Bennu and Ryugu particles will be handled and prepared (e.g., ultra-thin sections for scanning electron microscopy (SEM) or transmission electron microscopy (TEM)) using an Axis Pro micromanipulator and Leica EM UC7 ultramicrotome. Analyzing samples at the atomic scale will provide greater insight to the origins of the solar system and life formation on Earth. All the curation preparation for these sample collections is essential to ongoing research and efforts to understand our solar system, both nowand for future generations.

Curation↗

NASA's Rodent Research Project on ISS: Validation of a New Platform for Conducting Biomedical and Basic Research into the Consequences of Long Duration Habitation in Space

Rodent research has played a key role in advancing biomedical discoveries both on Earth and in space. The National Research Counsel’s Decadal survey(1) emphasized the importance of expanding NASAs life sciences research to perform long duration, rodent experiments on the International Space Station (ISS). To accomplish this objective, flight hardware, operations, and science capabilities were developed at NASA ARC to support both commercial and government-sponsored rodent research.Rodent Research-1 (RR-1) was the first mission in which animals were delivered and maintained in the ISS for a long duration mission in modified Animal Enclosure Module hardware. Both RR validation and commercial science objectives were pursued on the RR-1 mission. Adult female mice (20 total Flight, FLT) were launched Sept 21, 2014 in RR hardware within a Dragon Capsule (SpaceX4), then after 4 days in transit, were transferred for habitation on the ISS for 17 days (commercial) or 33 days (validation), when animals were euthanized and select tissues recovered on orbit. Various controls groups consisted of: 1) Basal mice from the same cohorts as FLT mice, but tissues were recovered at time of launch, 2) Vivarium (VIV) were housed in standard cages 3) Ground Controls (GC) were housed in flight hardware within an environmental chamber at Kennedy Space Center. The health and behavior of all mice on the ISS were monitored by video feed on a daily basis. Mice were euthanized by injection of Euthasol, then either fast frozen intact or dissected to preserve livers (fast frozen) and spleens (RNAlater). Samples were stored at ≤ -80˚C until their return to Earth for later analyses.Hardware performed nominally throughout the mission and the planned in-flight science operations were completed successfully. FLT mice appeared generally more physically active on orbit than respective GC groups. After 33 days on the ISS, mean body weights of FLT mice did not differ from GC, with both groups showing a 6% rise compared to time of launch, while VIV mice showed an 8% rise over the same period. Importantly, there were no significant differences in body weights between groups at the end of 33 days on the ISS, providing an indication that the RR hardware supported the health of the mice both on Earth and in space. Based on the preliminary data obtained from the livers and spleens of mice after 17 days on the ISS, purified RNA was of high quality (RIN values of spleen: FLT=9.48 +0.40, GC=9.28 +0.44, n=5/group); therefore, RNA quality from samples retrieved on orbit was acceptable for even the most demanding transcriptomic analyses. In addition, liver enzyme activity levels (units/mg protein) of FLT mice (after 17d on ISS) and all control mice were similar in magnitude to samples that were optimally prepared by freezing in liquid nitrogen in the laboratory (enzymes analyzed included catalase, glutathione reductase and glyceraldehyde-3-phosphate dehydrogenase). Validation analyses still in progress include behavior and tissue biochemistries, as well as optimization of science return by post-flight recovery of tissues for biospecimen sharing and global expression analyses.Together, these preliminary findings demonstrate new capability for supporting long duration rodent research on the ISS to achieve both basic science and biomedical objectives.

Globus, R. K.↗

Determining and analyzing the strength and impact resistance of high modulus glass

An error was noticed recently in the computer program used to reduce the laboratory sonic measurements to tabulated values of Young's modulus of the bulk samples of experimental glasses. Correction of this error gave revised values for the last fifty experimental glasses prepared in this laboratory. This corrected data, when examined as input material for the calculation of Young's modulus of bulk glasses from composition by the C. J. Phillips procedure, resulted in new values for the contribution per mol of several oxides. The new value for the zinc oxide molal factor is especially significant since it is slightly greater than the factor for beryllia for the types of glasses melted in the UARL research program. This discovery provides a new tool in the search for nontoxic, i.e. without beryllia, high modulus glass fibers particularly when coupled with recent measurements that showed zinc oxide contributes significantly to increased impact strength. New glass compositions prepared in this period and the latest impact strength values measured are also included.

Bacon, J. F.↗

Reactive control and reasoning assistance for scientific laboratory instruments

Scientific laboratory instruments that are involved in chemical or physical sample identification frequently require substantial human preparation, attention, and interactive control during their operation. Successful real-time analysis of incoming data that supports such interactive control requires: (1) a clear recognition of variance of the data from expected results; and (2) rapid diagnosis of possible alternative hypotheses which might explain the variance. Such analysis then aids in decisions about modifying the experiment protocol, as well as being a goal itself. This paper reports on a collaborative project at the NASA Ames Research Center between artificial intelligence researchers and planetary microbial ecologists. Our team is currently engaged in developing software that autonomously controls science laboratory instruments and that provides data analysis of the real-time data in support of dynamic refinement of the experiment control. the first two instruments to which this technology has been applied are a differential thermal analyzer (DTA) and a gas chromatograph (GC). coupled together, they form a new geochemicstry and microbial analysis tool that is capable of rapid identification of the organiz and mineralogical constituents in soils. The thermal decomposition of the minerals and organics, and the attendance release of evolved gases, provides data about the structural and molecular chemistry of the soil samples.

Thompson, David E.↗

Rapid Nucleic Acid Isolation Method and Fluid Handling Devices Overview

Sample preparation is a common bottleneck in genetic analysis. Tools that reduce time and effort are of value in a laboratory setting. There is a need for a genetic analysis/detection system that is not only mobile, ruggedized, easy-to-use but also provides an enclosed fluid handling that diminishes the risks of Ribonucleic acid (RNA) contamination and degradation during processing. NASA has developed a novel assay methodology and suite of devices to isolate nucleic acids and prepare samples for real-time (quantitative) polymerase chain reaction (PCR) analysis that solves the problem of contamination and degradation because of the advanced microfluidics which provides better fluid handling. The assay employs an aqueous-based non-alcohol method that yields robust RNA quality. The suite of ready-to-use devices provide pre-loaded reagents in liquid and lyophilized formats to enable rapid, cost effective, and portable manual operation in the laboratory or remote field environments.

Travis Boone↗

Changes in spectral properties of detached leaves

If leaf senescence can be delayed for several days without significant changes in spectral properties, then samples of leaves at remote test sites could be prepared and shipped to laboratories to measure spectral properties. The changes in spectral properties of detached leaves were determined. Leaves from red birch and red pine were immersed in water or 0.001 M benzylaminopurine (BAP) and stored in plastic bags in the dark at either 5 or 25 C. Total directional-hemispherical reflectance and transmittance of the adaxial surface of birch leaves were measured over the 400 to 1100 nm wavelength region with a spectroradiometer and integrating sphere. Pine needles were taped together and reflectance of the mat of needles was measured. Spectral properties changed less than 5% of initial values during the first week when leaves were stored at 5 C. Storage at 25 C promoted rapid senescence and large changes in spectral properties. BAP delayed, but did not stop, senescence at 25 C.

Daughtry, C. S. T.↗

Re-Evaluation of Ar-39 - Ar-40 Ages for Apollo Lunar Rocks 15415 and 60015

We re-analyzed 39Ar-40Ar ages of Apollo lunar highland samples 15415 and 60015, two ferroan anorthosites analyzed previously in the 1970 s, with a more detailed approach and with revised decay constants. From these samples we carefully prepared 100-200 mesh mineral separates for analysis at the Noble Gas Laboratory at NASA-Johnson Space Center. The Ar-39-Ar-40 age spectra for 15415 yielded an age of 3851 +/- 38 Ma with 33-99% of Ar39 release, roughly in agreement with previously reported Ar-Ar ages. For 60015, we obtained an age of 3584 +/- 152 Ma in 23-98% of Ar39 release, also in agreement with previously reported Ar-Ar ages of approximately 3.5 Ga. Highland anorthosites like these are believed by many to be the original crust of the moon, formed by plagioclase floatation atop a magma ocean, however the Ar-Ar ages of 15415 and 60015 are considerably younger than lunar crust formation. By contrast, recently recovered lunar anorthosites such as Dhofar 489, Dhofar 908, and Yamato 86032 yield older Ar-Ar ages, up to 4.35 Ga, much closer to time of formation of the lunar crust. It follows that the Ar-Ar ages of the Apollo samples must have been reset by secondary heating, and that this heating affected highland anorthosites at both the Apollo 15 and Apollo 16 landing sites but did not affect lunar highland meteorites. One obvious consideration is that while the Apollo samples were collected from the near side of the moon, these lunar meteorites are thought to have originated from the lunar far side

Park, J.↗