Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

Fast increased fidelity samplers for approximate Bayesian Gaussian process regression

Gaussian processes (GPs) are common components in Bayesian non-parametric models having a rich methodological literature and strong theoretical grounding. The use of exact GPs in Bayesian models is limited to problems containing several thousand observations due to their prohibitive computational demands. We develop a posterior sampling algorithm using H-matrix approximations that scales at O(n log 2 n). We show that this approximation’s Kullback-Leibler divergence to the true posterior can be made arbitrarily small. Though multidimensional GPs could be used with our algorithm, d-dimensional surfaces are modeled as tensor products of univariate GPs to minimize the cost of matrix construction and maximize computational efficiency. We illustrate the performance of this fast increased fidelity approximate GP, FIFA-GP, using both simulated and non-synthetic data sets

97 MATHEMATICS AND COMPUTING↗

Transitional Markov Chain Monte Carlo Sampler in UQTk

Transitional Markov Chain Monte Carlo (TMCMC) is a variant of a class of Markov Chain Monte Carlo algorithms known as tempering-based methods. In this report, the implementation of TMCMC in the Uncertainty Quantification Toolkit is investigated through the sampling of high-dimensional distributions, multi-modal distributions, and nonlinear manifolds. Furthermore, the Bayesian model evidence estimates obtained from TMCMC are tested on problems with known analytical solutions and shown to provide consistent results.

97 MATHEMATICS AND COMPUTING↗

A Hierarchical Gibbs Sampler for Spatially Varying Multi-Regularization Image Reconstructions

This is a presentation for SIAM's (Society for Industrial and Applied Mathematics) conference on computational science and engineering. This presentation describes research on novel techniques to deblur images under a Bayesian framework. The title of the conference is SIAM Conference on Computational Science and Engineering (CSE21). This is a VIRTUAL conference; it was originally scheduled in Fort Worth, TX. The conference dates are March 1-5, 2021. The link to the conference's website is https://www.siam.org/conferences/cm/conference/cse21

97 MATHEMATICS AND COMPUTING↗

Enabling depth resolved temporal resolved soil microbial sampling with novel vadose zone diffusion sampler

To address the difficulty in Earth system science in making time-course measurements of molecular signatures in soil biochemistry, we developed a soil stake system to sample and replace a defined soil analog medium, connected through hydraulic connectivity via perforated casings and modular inserts. We deployed these stakes to a site in Prosser, WA and measured microbial colonization of sterile sand-clay inserts enriched with N-acetyl-glucosamine at different depths over spring and summer. DNA and RNA analyses revealed distinct microbial recruitment and activity patterns. Inserts showed lower microbial diversity but higher abundance of Proteobacteriota and Bacteriota compared to native soils, alongside seasonal shifts in taxonomic and functional profiles. The soil stake system offers a novel approach for studying microbial dynamics across temporal and spatial scales.

58 GEOSCIENCES↗

Self timed data sampler

A sampling circuit automatically resamples the data from another timing domain until the sampled data is represented correctly in the new domain by assuring that no metastable states exist. If a metastable state exists, a sampling signal recirculates through the sampling circuit until the metastable state no longer exists. A comparison of input data to sampled data is used to determine the existence of a metastable state.

42 ENGINEERING↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Updated Application of Frequency of Detection Methods for the INL Site Ambient Air Monitoring Network

This report presents a quantitative assessment of the current INL Site air monitoring network using frequency of detection (FD) methods. The first assessment of the INL network was performed in 2015 and made recommendations for improving the network. As a result of changes made in response to the recommendations and the addition of new source locations, the network was modified and reassessed in 2017. Since 2017, administration of the air sampling program has been consolidated under one contractor, which resulted in additional changes to the network (sampler numbers and locations) and changes in radionuclide detection levels. As a result of these changes and others, an updated assessment of the INL Site ambient air monitoring network was performed. The same two exposure scenarios used in previous assessments were used for this assessment: a resident scenario and a shepherd/rancher scenario. The resident was assumed to be continuously present at their residence/business/farm operation outside the INL Site boundary while the shepherd/rancher was assumed to be present 24-hours at the nearest INL grazing allotment boundary in each of the 22.5-degree sectors along the sector centerline from each source. Updates to both the resident and shepherd/rancher receptor locations were included. Other changes include updates to flow rates for stack sources, expansion of the list of important radionuclides based on the most recent National Emission Standards for Hazardous Pollutants (NESHAPs) analysis, and updated dose coefficients. The assessment was conducted to determine whether the current INL monitoring network is capable of detecting releases of important radionuclides from INL Site sources that have the potential to exceed a conservative dose threshold for the two exposure scenarios. The assessment revealed that for the resident scenario, the current network meets the desired performance objective (FD = 95%) for all radionuclides and sources except for Cl-36 from the TRA-770 stack (94.4%). For the shepherd/rancher scenario, the FD performance objective is met for all radionuclides and sources except tritium from MFC-774 and TAN 679 (91% for both). An investigation of reported emissions for the past three years revealed that Cl 36 is not emitted from TRA-770, and routine tritium emissions from MFC-774 and TAN-679 are very small and the sources are likely incapable of emitting enough tritium to cause a release that should be detectable by the monitoring network. This assessment is based on a conservative dose threshold. This coupled with fact that the FD for Cl 36 is only slightly less than the performance objective and Cl-36 is not emitted from TRA-770, modifying the network (i.e. adding another sampler, increasing sampler flow rate, moving samplers) to meet the 95% performance objective for this radionuclide/source/receptor scenario is not warranted. Similarly, because tritium emissions from MFC-774 and TAN-679 are very small and these two sources are likely incapable of causing a dose due to tritium release that should be detectable by the network, modifications to increase tritium detection for these sources is also unwarranted at this time. However, if it is required to meet the performance objective for tritium for all sources and receptor scenarios, additional analysis determined the FD could be raised from 91% to > 99% for both sources by adding two tritium samplers to the network.

61 RADIATION PROTECTION AND DOSIMETRY↗