Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

Size Selectivity of Sampling Gears Used to Sample Kokanee

Abstract Kokanee Oncorhynchus nerka provide valued recreational fisheries and also serve as a prey resource for economically, socially, and ecologically important fishes. As such, management of kokanee is a major focus of natural resource agencies. Kokanee are typically monitored using midwater trawls, but the interpretation of data collected using midwater trawls is difficult due to the unknown size selectivity of the gear. We sought to assess the length selectivity of midwater trawls by comparing estimates obtained from midwater trawls with estimates obtained from gill nets adjusted for size selectivity. Experimental curtain gill nets and midwater trawls were used in conjunction to sample kokanee in seven lentic systems in Idaho. The size selectivity of gill nets was estimated by accounting for the probability of encounter and the probability of retention. Estimates of size selectivity were then used to adjust the length distribution of fish sampled in gill nets. The adjusted length distribution of fish sampled in gill nets was compared with estimates obtained from midwater trawls to identify potential size selectivity of midwater trawls. A pattern of size selectivity was apparent for both sampling techniques. The average length of kokanee sampled with midwater trawls was 111 mm; whereas, kokanee sampled with gill nets had a mean length of 235 mm. Our results suggest experimental gill nets are useful for common sampling of kokanee (e.g., trend monitoring) because the gear is less size selective than midwater trawls and is adjustable for size selectivity. However, midwater trawls are likely the best gear for addressing questions associated with early life history. Overall, our results provide a better understanding of gill-net and midwater trawl selectivity and ultimately improve the ability to sample and manage the species.

Klein, Zachary B.↗

Investigation of Sampling-Probe Distorted Temperature Fields with X-Ray Fluorescence Spectroscopy

Flame-sampling experiments, especially in conjunction with laminar low-pressure premixed flames, are routinely used in combustion chemistry studies to unravel the identities and quantities of key intermediates and their pathways. In many instances, however, an unambiguous interpretation of the experimental and modeling results is hampered by the uncertainties about the probe-induced, perturbed temperature profile. To overcome this limitation, two-dimensional perturbations of the temperature field caused by sampling probes with different geometries have been investigated using synchrotron-based X-ray fluorescence spectroscopy. In these experiments, which were performed at the 7-BM beamline of the Advanced Photon Source (APS) at the Argonne National Laboratory, a continuous beam of hard X-rays at 15 keV was used to excite krypton atoms that were added in a concentration of 5 vol.-% to the unburnt gas mixture and the resulting krypton fluorescence at 12.65 keV was subsequently collected. The highly spatially resolved signal was converted into the local flame temperature to obtain temperature fields at various burner-probe separations as functions of the distance to the burner surface and the radial distance from the centerline. Multiple measurements were performed with different probe geometries and because of the observed impact on the temperature profiles the results clearly revealed the need to specify the sampling probe design to enable quantitative and meaningful comparisons of modeling results with flame-sampled mole fraction data. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Hansen, N.↗

Searching For Transiting Planets Around Halo Stars. I. Sample Selection and Validation

By measuring the elemental abundances of a star, we can gain insight into the composition of its initial gas cloud—the formation site of the star and its planets. Planet formation requires metals, the availability of which is determined by the elemental abundance. In the case where metals are extremely deficient, planet formation can be stifled. To investigate such a scenario requires a large sample of metal-poor stars and a search for planets therein. This paper focuses on the selection and validation of a halo star sample. We select ~17,000 metal-poor halo stars based on their Galactic kinematics, and confirm their low metallicities ([Fe/H] < -0.5), using spectroscopy from the literature. Furthermore, we perform high-resolution spectroscopic observations using LBT/PEPSI and conduct detailed metallicity ([Fe/H]) analyses on a sample of 13 previously-known halo stars that also have hot kinematics. We can use the halo star sample presented here to measure the frequency of planets and to test planet formation in extremely metal-poor environments. The result of the planet search and its implications will be presented and discussed in a companion paper by Boley et al.

47 OTHER INSTRUMENTATION↗

13 C-Isotope-Assisted Assessment of Metabolic Quenching During Sample Collection from Suspension Cell Cultures

Metabolomics and fluxomics are core approaches to directly profile and interrogate cellular metabolism in response to various genetic or environmental perturbations. In order to accurately measure the abundance and isotope enrichment of intracellular metabolites, cell culture samples must be rapidly harvested and cold-quenched to preserve the in vivo metabolic state of the cells at the time of sample collection. When dealing with suspension cultures, this process is complicated by the need to separate the liquid culture media from cellular biomass prior to metabolite extraction. Here, we examine the efficacy of several commonly used metabolic quenching methods, using the model cyanobacterium Synechocystis sp. PCC 6803 as an example. Multiple 13 C-labeled compounds, including 13 C-bicarbonate, 13 C-glucose and 13 C-glutamine, were used as tracers during the sample collection and cold-quenching process to assess the extent of metabolic turnover after cells were harvested from culture flasks. We show that the combination of rapid filtration followed by 100% cold (–80°C) methanol quenching exhibits the highest quenching efficiency, while mixing cell samples with a partially frozen 30% methanol slurry (–24°C) followed by centrifugation is slightly less effective at quenching metabolism but enables less laborious sample processing. By contrast, rapidly mixing the cells with a saline ice slurry (~0°C) is less effective as indicated by high isotope-labeling rates after sample harvest, while mixing the cells with 60% cold methanol (–65°C) prior to centrifugation causes significant metabolite loss. Furthermore, this study demonstrates a rigorous, quantitative, and broadly applicable method for assessing the metabolic quenching efficacy of protocols used for sample collection in metabolomics and fluxomics studies.

59 BASIC BIOLOGICAL SCIENCES↗

A sub-sampled approach to extremely low-dose STEM

The inpainting of deliberately and randomly sub-sampled images offers a potential means to image specimens at a high resolution and under extremely low-dose conditions (≤1 e - /Å 2 ) using a scanning transmission electron microscope. We show that deliberate sub-sampling acquires images at least an order of magnitude faster than conventional low-dose methods for an equivalent electron dose. More importantly, when adaptive sub-sampling is implemented to acquire the images, there is a significant increase in the resolution and sensitivity which accompanies the increase in imaging speed. Lastly, we demonstrate the potential of this method for beam sensitive materials and in-situ observations by experimentally imaging the node distribution in a metal-organic framework.

47 OTHER INSTRUMENTATION↗

Sampling and Analysis Plan for Verification Sampling of LANL-Derived Residual Radionuclides in Soils within Tract A-18-2 for Land Conveyance

Public Law 105-119 directs the U.S. Department of Energy (DOE) to convey or transfer parcels of land to the Incorporated County of Los Alamos or their designees and to the Department of Interior, Bureau of Indian Affairs, in trust for the Pueblo de San Ildefonso. Los Alamos National Security is tasked to support DOE in conveyance and/or transfer of identified land parcels no later than September 2022. Under DOE Order 458.1, Radiation Protection of the Public and the Environment (O458.1, 2013) and Los Alamos National Laboratory (LANL or the Laboratory) implementing Policy 412 (P412, 2014), real property with the potential to contain residual radioactive material must meet the criteria for clearance and release to the public. This Sampling and Analysis Plan (SAP) is a second investigation of Tract A-18-2 for the purpose of verifying the previous sampling results (LANL 2017). This sample plan requires 18 projectspecific soil samples for use in radiological clearance decisions consistent with LANL Procedure ENV-ES-TP-238 (2015a) and guidance in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM, 2000). The sampling work will be conducted by LANL, and samples will be evaluated by a LANL-contracted independent lab. However, there will be federal review (verification) of all steps of the sampling process.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Tank 11H samples from tank closure cesium removal (TCCR) Batch 3 - intermediate and final samples

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. The TCCR unit processes dissolved salt from Tank 10H through a series of ion exchange columns containing crystalline silicotitanate (CST) and the effluent is then discharged to Tank 11H. Four interim samples pulled from Tank 11H during and just after the completion of processing of Batch 3 through the TCCR process have been analyzed for 137 Cs activity and density. The 137 Cs activity was found to decrease with each subsequent sample, which is consistent with the addition of decontaminated solution to Tank 11H. When compared to the expected composition from mixing the Tank 10H Batch 3 feed with the material already present in Tank 11H, the bulk chemical composition was as expected. A corrosion control sample collected from Tank 11H in June 2020 showed changes in the chemical composition and 137 Cs activity when compared to the composition measured at the end of Batch 2 processing. As there were no additions made to the tank during this period, these changes were attributed to leaching of the solids present in Tank 11H. Revision 1 of this report contains additional analyses of the fourth interim sample including inductively coupled plasma – mass spectrometry (ICP-MS) results and activities of other radionuclides. These results are consistent with the previously reported results, showing leaching from the Tank 11H heel. Notably, the 90 Sr activity was about 2.7x higher than calculated from a mixture of the original Tank 11H supernate and the Tank 10H supernate as treated by TCCR, suggesting additional leaching of Sr from the Tank 11H heel solids. In addition, Revision 1 includes analysis results for the Batch 3 Post-Production surface and variable depth samples collected in October of 2020. The Post-Production surface sample was similar in composition to the fourth interim surface sample, except for the increased Cs-137 and oxalate concentrations that were presumably associated with leaching of the Tank 11H heel solids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Demonstration of a Prototype Molten Salt Sampling System

Molten salt reactors (MSRs) offer potential operability and safety advantages when compared to commercial light water reactors (LWRs). However, operating experience with MSRs is sparse in comparison to what exists for LWRs. Further, the chemical and isotopic composition of the fuel and/or coolant salt is dynamic and difficult to characterize continuously, posing potential safety, operability, and safeguards unknowns that need to be addressed. A molten salt sampling system (MSSS) is regarded as a necessary subsystem within first generation MSRs used to obtain samples of salt for chemical and isotopic analysis in support of the need to monitor and control salt composition during operation. The MSSS is being developed using the Safety-in-Design (SiD) methodology, which incorporates incremental integration of safety analysis into the design process. The MSSS conceptual design emerging from the application of the early stages of the SiD methodology consists of a sample collection system and its housing, a freeze port, and inert gas control and delivery systems. This article describes the prototypes developed to test the functions of these MSSS subsystems, presents the results of testing in both dry and molten salt environments (including reliability data collection performed in accordance with the principles of SiD and the development of a semiquantitative fault tree model), and summarizes the opportunities for future design and testing enhancements based on the results of prototype testing.

molten salt reactor↗

The Combination of Rejection Sampling with Biased Probability Density Sampling (with Special Comments on MCNP "Cookie Cutter" Rejection)

Sampling from biased probability densities and rejection sampling are both very common Monte Carlo techniques. As far as I know, the combination of sampling from a biased density and rejection sampling has not been developed. This note develops the theory for sampling from a biased density and then accepting or rejecting that sampling.

97 MATHEMATICS AND COMPUTING↗

Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, in this work, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

59 BASIC BIOLOGICAL SCIENCES↗

Spectral variability of a sample of extreme variability quasars and implications for the MgII broad-line region

We present new Gemini/GMOS optical spectroscopy of 16 extreme variability quasars (EVQs) that dimmed bymore than 1.5mag in the g band between the Sloan Digital Sky Survey (SDSS) and the Dark Energy Survey epochs (separated by a few years in the quasar rest frame). These EVQs are selected from quasars in the SDSS Stripe 82 region, covering a redshift range of 0.5 < z < 2.1. Nearly half of these EVQs brightened significantly (by more than 0.5 mag in the g band) in a few years after reaching their previous faintest state, and some EVQs showed rapid (non-blazar) variations of greater than 1-2 mag on time-scales of only months. To increase sample statistics, we use a supplemental sample of 33 EVQs with multi-epoch spectra from SDSS that cover the broad Mg II lambda 2798 line. Leveraging on the large dynamic range in continuum variability between the multi-epoch spectra, we explore the associated variations in the broad MgII line, whose variability properties have not been well studied before. The broad MgII flux varies in the same direction as the continuum flux, albeit with a smaller amplitude, which indicates at least some portion of Mg II is reverberating to continuum changes. However, the full width at half-maximum (FWHM) of Mg II does not vary accordingly as continuum changes for most objects in the sample, in contrast to the case of the broad Balmer lines. Using the width of broad MgII to estimate the black hole mass with single epoch spectra therefore introduces a luminosity-dependent bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Broad Genomic Sampling Reveals a Smut Pathogenic Ancestry of the Fungal Clade Ustilaginomycotina

Ustilaginomycotina is home to a broad array of fungi including important plant pathogens collectively called smut fungi. Smuts are biotrophs that produce characteristic perennating propagules called teliospores, one of which, Ustilago maydis , is a model genetic organism. Broad exploration of smut biology has been hampered by limited phylogenetic resolution of Ustilaginiomycotina as well as an overall lack of genomic data for members of this subphylum. In this study, we sequenced eight Ustilaginomycotina genomes from previously unrepresented lineages, deciphered ordinal-level phylogenetic relationships for the subphylum, and performed comparative analyses. Unlike other Basidiomycota subphyla, all sampled Ustilaginomycotina genomes are relatively small and compact. Ancestral state reconstruction analyses indicate that teliospore formation was present at the origin of the subphylum. Divergence time estimation dates the divergence of most extant smut fungi after that of grasses (Poaceae). However, we found limited conservation of well-characterized genes related to smut pathogenesis from U. maydis , indicating dissimilar pathogenic mechanisms exist across other smut lineages. The genomes of Malasseziomycetes are highly diverged from the other sampled Ustilaginomycotina, likely due to their unique history as mammal-associated lipophilic yeasts. Despite extensive genomic data, the phylogenetic placement of this class remains ambiguous. Although the sampled Ustilaginomycotina members lack many core enzymes for plant cell wall decomposition and starch catabolism, we identified several novel carbohydrate active enzymes potentially related to pectin breakdown. Finally, ~50% of Ustilaginomycotina species-specific genes are present in previously undersampled and rare lineages, highlighting the importance of exploring fungal diversity as a resource for novel gene discovery.

59 BASIC BIOLOGICAL SCIENCES↗

Deterministic Linear Time for Maximal Poisson‐Disk Sampling using Chocks without Rejection or Approximation

Abstract We show how to sample uniformly within the three‐sided region bounded by a circle, a radial ray, and a tangent, called a “chock.” By dividing a 2D planar rectangle into a background grid, and subtracting Poisson disks from grid squares, we are able to represent the available region for samples exactly using triangles and chocks. Uniform random samples are generated from chock areas precisely without rejection sampling. This provides the first implemented algorithm for precise maximal Poisson‐disk sampling in deterministic linear time. We prove O(n · M(b) log b), where n is the number of samples, b is the bits of numerical precision and M is the cost of multiplication. Prior methods have higher time complexity, take expected time, are non‐maximal, and/or are not Poisson‐disk distributions in the most precise mathematical sense. We fill this theoretical lacuna.

Mitchell, Scott A.↗

The Complete Light-curve Sample of Spectroscopically Confirmed SNe Ia from Pan-STARRS1 and Cosmological Constraints from the Combined Pantheon Sample

Here, we present optical light curves, redshifts, and classifications for 365 spectroscopically confirmed Type Ia supernovae (SNe Ia) discovered by the Pan-STARRS1 (PS1) Medium Deep Survey. We detail improvements to the PS1 SN photometry, astrometry, and calibration that reduce the systematic uncertainties in the PS1 SN Ia distances. We combine the subset of 279 PS1 SNe Ia (0.03 < z < 0.68) with useful distance estimates of SNe Ia from the Sloan Digital Sky Survey (SDSS), SNLS, and various low-z and Hubble Space Telescope samples to form the largest combined sample of SNe Ia, consisting of a total of 1048 SNe Ia in the range of 0.01 < z < 2.3, which we call the Pantheon Sample. When combining Planck 2015 cosmic microwave background (CMB) measurements with the Pantheon SN sample, we find Ω m = 0.307 ± 0.012 and w = -1.026 ± 0.041 for the wCDM model. When the SN and CMB constraints are combined with constraints from BAO and local H 0 measurements, the analysis yields the most precise measurement of dark energy to date: w 0 = -1.007 ± 0.089 and w α = -0.222 ± 0.407 for the w 0 w α CDM model. Tension with a cosmological constant previously seen in an analysis of PS1 and low-z SNe has diminished after an increase of 2× in the statistics of the PS1 sample, improved calibration and photometry, and stricter light-curve quality cuts. We find that the systematic uncertainties in our measurements of dark energy are almost as large as the statistical uncertainties, primarily due to limitations of modeling the low-redshift sample. This must be addressed for future progress in using SNe Ia to measure dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Solid phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Solid-phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

CatMass : software for calculating optimal sample masses for X-ray absorption spectroscopy experiments involving complex sample compositions

This paper presents software for calculating the optimal mass of samples with complex compositions ( e.g. supported metal catalysts) for X-ray absorption spectroscopy (XAS) and scattering measurements. The ability to calculate the sample mass and other relevant parameters needed for an XAS measurement allows experimentalists to be better prepared in terms of detector selection, energy range of scan and overall time needed to complete the measurement, thus increasing efficiency. CatMass builds on existing sample mass calculators allowing users to determine the optimum sample preparation, collection geometry, usable energy range for a scan and approximate edge step of the absorption event. Visualization tools present the absorption calculation results in a format familiar to XAS experimentalists, with the added ability to save calculations and plots for future reference or recalculation. CatMass is a program broadly applicable in catalysis and is helpful for users with complex samples due to composition/stoichiometry or multiple competing elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗