Search NASA⌕ Search

SEARCH · Search NASA

Results for “Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

The Cost of Saving Electricity: A Multi-Program Cost Curve for Programs Funded by U.S. Utility Customers

This study analyzed the cost performance of electricity efficiency programs implemented by 116 investor-owned utilities between 2009 and 2015 in 41 states, representing about three-quarters of the total spending on U.S. efficiency programs. We applied our typology to characterize efficiency programs along several dimensions (market sector, technology, delivery approach, and intervention strategy) and report the costs incurred by utilities and other program administrators to achieve electricity savings as a result of the programs. Such cost performance data can be used to compare relative costs of different types of efficiency programs, evaluate efficiency options alongside other electricity resources, benchmark local efficiency programs against regional and national cost estimates, and assess the costs of meeting state efficiency policies. The savings-weighted average cost of saved electricity for the period was $0.025/kilowatt-hour (kWh). The cost of saved electricity for programs that targeted residential customers was $0.021/kWh, compared to $0.025/kWh for programs for commercial and industrial customers. Ultimately, we developed an aggregate program savings “cost curve” for the actual electricity efficiency resource during the period that provides insights into the relative costs of various types of efficiency programs and the savings contribution of each program type to the efficiency resource at a national level.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Meaningful Household Savings: Best Practices for Achieving Equitable Solar Development

The Meaningful Household Savings Community of Practice—and this report—focuses on electricity bill savings, other household savings, wealth-building opportunities, and other benefits such as tenant services provided to residents in master-metered buildings. For this report, the project team collected information about ways meaningful household savings have been defined; researched best practices to define, achieve, and quantify meaningful household savings; and identified strategies to scale the adoption and implementation of successful methods.

14 SOLAR ENERGY↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intersecting heuristic adaptive strategies, building design and energy saving intentions when facing discomfort environment: A cross-country analysis

Occupants' adaptive strategies play an important role in the energy consumption of office buildings. Previous research has mostly focused on the adaptive strategies triggered by occupants' indoor discomfort; however, it is crucial to understand if specific adaptive strategies are linked to occupants' energy-saving intentions. This study explores the relationships among employees’ heuristic decision-making in their first choice of adaptive strategies (technological solutions or personal adjustments) when facing extreme discomfort conditions, and their energy-saving intentions, then links these patterns with building design, workplace contextual factors, and demographics. A cross-sectional survey was collected among university employees from China, Brazil, Italy, Poland, Switzerland, and the US. Our results demonstrated that the accessibility to indoor environmental controls (IECs) and office type are the significant factors for adaptive strategies. There was a positive relationship between the number of IEC features and the percentage of employees choosing a technological solution. When feeling too hot, occupants in private offices are more likely to adopt a technological solution, whereas occupants in cubicles are more likely to choose a personal adjustment. Occupants with energy-saving intentions are less likely to choose thermostat adjustments or use portable devices as adaptive strategies than their counterparts. Lastly, the cluster analysis suggests females were more likely to use adaptive strategies for energy-saving purposes than males. The majority of occupants would turn on/off lighting to save energy. The study provides the contributions in the connection between the heuristic decision-making process and energy-saving intentions and recommendations on design strategies for building architects, engineers, and managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

Two (or more) for one: Identifying classes of household energy- and water-saving measures to understand the potential for positive spillover

A key component of behavior-based energy conservation programs is the identification of target behaviors. A common approach is to target behaviors with the greatest energy-saving potential. The concept of behavioral spillover introduces further considerations, namely that adoption of one energy-saving behavior may increase (or decrease) the likelihood of other energy-saving behaviors. This research aimed to identify and describe household energy- and water-saving measure classes within which positive spillover is likely to occur (e.g., adoption of energy-efficient appliances may correlate with adoption of water-efficient appliances), and explore demographic and psychographic predictors of each. Nearly 1,000 households in a California city were surveyed and asked to report whether they had adopted 75 different energy- and/or water-saving measures. Principal Component Analysis and Network Analysis based on correlations between adoption of these diverse measures revealed and characterized eight water-energy-saving measure classes: Water Conservation, Energy Conservation, Maintenance and Management, Efficient Appliance, Advanced Efficiency, Efficient Irrigation, Green Gardening, and Green Landscaping. Understanding these measure classes can help guide behavior-based energy program developers in selecting target behaviors and designing interventions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Demand Savings from Efficiency: Opportunities and Practices [Slides]

Electricity systems are designed to meet peak demand - the maximum load during a specified period, typically in summer - even if that demand occurs only a few hours in a year. Yet most evaluations of electricity efficiency programs focus on reductions in annual energy use. However, these efficiency programs are also delivering peak demand savings at an affordable cost. A new study by the Department of Energy’s Lawrence Berkeley National Laboratory (Berkeley Lab) explores the program administrator (PA) cost - or the cost to implement an energy efficiency program to a utility or third party administrator - of saving peak demand through efficiency programs for electric utility customers. Berkeley Lab collected data on costs, annual energy savings, and peak demand savings for electricity efficiency programs for 52 utilities and other program administrators in 15 states between 2014 and 2018. The analysis focused on eight program types that represent 68% of the peak demand savings for the utilities and program administrators studied. The findings improve our understanding of which energy efficiency programs produce the most peak demand savings and their cost performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ePROJECT BUILDER: PROMOTING WIDER ADOPTION OF ENERGY SAVINGS PERFORMANCE CONTRACTS THROUGH STANDARDIZATION AND TRANSPARENCY

The United States Federal Government has been conducting guaranteed savings energy savings performance contracts for over 20 years and now relies on ESPC for the majority of its energy efficiency work. Along with a related financed project type, these deals resulted in $4.2 billion of project investment in the five years ending in 2016, a pace that has even accelerated since. Measurement and verification (M&V) on the projects is the key to assuring savings realization and persistence. Perceived as a weakness or burdensome added cost in the early years of the program, M&V has become a strength. All energy conservation measures (ECMs) have some form of measurement – defined as a measured baseline establishment followed by at least one measurement of the main energy-saving parameter taken in the performance period for each ECM. The government’s in-house energy consulting office, the Federal Energy Management Program (FEMP), now recommends measurement of these “Option A” M&V ECMs throughout the contract term, usually annually. Moreover, a significantly higher percentage of projects are now characterized by more ambitious M&V, including Option B (all parameter measurement) for most generation (including renewable) and some efficiency measures, and more frequent Option C (whole facility utility bill analysis) for “deep retrofit” projects with multiple, interactive ECMs. Coincident with this progress in M&V has been a much greater embracing of ESPC by the federal agencies, resulting in the enormous rate of projects now executed. This paper traces the evolution of M&V in federal ESPC and argues that the heightened credibility of the savings has contributed significantly to the procurement vehicle’s long-term viability. This focus on savings integrity via M&V has been learned over two decades for U.S. federal ESPC, but countries with developing ESPC markets would be wise to emphasize it as their markets emerge, allowing them to avoid some of the “growing pains” experienced in the U.S.

Earni, Shankar↗

A framework for estimating the energy-saving potential of occupant behaviour improvement

Energy-related occupant behaviour in buildings has demonstrated considerable energy-saving potential. However, the current modelling method of occupant behaviour does not give sufficient considerations on the implementation difficulty of behaviour and provide a holistic map from survey data to various behaviour models. This article proposes a holistic survey-and-simulation-based framework for estimating the energy-saving potential of occupant behaviour improvement. In the framework, seven typical categories of occupant behaviour models are identified based on the survey results. According to the implementation difficulty, the models are integrated into four behaviour styles (baseline, wasteful, moderate and austere) to represent different levels of energy-saving consciousness of occupants. Based on a case study with a nationwide survey in Singapore, there are remarkable energy savings potential if occupant behaviour is improved; the building energy consumption can be reduced by up to 9.5% with the moderate behaviour improvement, and up to 21.0% with the aggressive behaviour improvement. The simulation results accord well with the measured results within a reasonable range of deviation. The framework can be applied to estimate the energy-saving potential of occupant behaviour improvement in a building with affordable cost, and the findings can inform a behaviour improvement programme with effective and efficient measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Two trillion gallons: Fuel savings from fuel economy improvements to US light-duty vehicles, 1975–2018

Since 1975, the fuel economy of new light-duty vehicles sold in the U.S. has almost doubled. Fuel economy improvements on laboratory tests gradually became real improvements on the road as newer, more efficient vehicles replaced older less efficient ones. Fleet-wide fuel economy gains produced large fuel savings. In this paper, we show that fuel economy gains measured on laboratory test cycles, adjusted for on-road conditions and weighted by the distribution of vehicles by age and their relative use, closely match estimates by the Federal Highway Administration based primarily on traffic counts and motor fuel tax records. Furthermore, adjusting for the rebound effect of fuel economy on vehicle miles traveled, we estimate the fuel savings, CO 2 emissions reductions and dollars saved on fuel due to fuel economy improvements over the past 43 years. Through the end of 2018, estimated cumulative fuel savings amount to approximately 2 trillion gallons of gasoline. We estimate that roughly one-fifth of the savings can be attributed to gasoline price increases over the period and four-fifths to fuel economy and greenhouse gas (ghg) standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗