Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematic investigation of complex samples containing both soft and hard materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparative study on the optical limiting properties of different nano spinel ferrites with Z-scan technique

Highlights: ► First report in which the optical limiting properties of five different nano spinel ferrites are compared. ► The obtained nonlinearity fits to a two-photon like absorption process. ► Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. ► A size dependent optical limiting response is obtained. ► Among the investigated ferrites, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. -- Abstract: We report the optical limiting properties of five different spinel ferrites, NiFe{sub 2}O{sub 4}, Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}, ZnFe{sub 2}O{sub 4}, Ni{sub 0.5}Co{sub 0.5}Fe{sub 2}O{sub 4}, and CoFe{sub 2}O{sub 4} with an average particle grain size of 8 nm. The optical limiting properties are investigated using the open aperture Z-scan technique. The obtained nonlinearity fits to a two-photon like absorption process. Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. The optical limiting response is also studied against particle size and the nonlinearity is found to increase with increasing particle size within the range of our investigations. On comparing the optical limiting properties, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. To the best of our knowledge, this is the first report where the optical limiting properties of spinel ferrites are compared.

36 MATERIALS SCIENCE↗

SU-E-T-621: Analysis of Robustness of Proton Pencil Beam Scanning Technique for Delivery of Craniospinal Irradiation

Purpose: To investigate the robustness and safety of craniospinal irradiation (CSI) planned with a proton pencil beam scanning (PBS) technique which overcomes the complexity of the planning associated with feathering match lines. Methods: Six CSI patients were planned with gradient-dose matching using PBS technique. Uniform dose coverage to the entire target volumes was achieved with averaged junction lengths of 6.9±0.3 cm. Robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in longitudinal direction and compared with the original non-shifted plan with metrics of conformity number (CN) and homogeneity index (HI). An anthropomorphic phantom study using film measurements was also carried out on a plan with 5 cm junction length. Results: For a given junction length, the dose errors were directly proportional to the setup errors. Setup errors of 3 mm from each field caused on average 3.5% lower CN and 2.1% higher HI. Minimal D95% to PTV and D98% to CTV were reduced by 2.2%±1.5% and 2.8%±1.7% respectively. A drop of maximal 6.8%±5.5% on the minimal dose to the cribriform plate was also observed. When the junction length was 5cm or longer, these 3mm setup errors from each field resulted in up to 12% dose errors. Consistent results were reached between film measurements and planned dose profiles in the junction area. Due to near-zero exit doses beyond the target volume, sparing of anterior organs such as heart, liver, lung and kidney were observed. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the CSI treatment with matched proton fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust and safe to longitudinal setup errors compared to conventional feathering methods.

60 APPLIED LIFE SCIENCES↗

First measurement of traverse beam optics for the Fermilab Muon Campus using a magnet scanning technique

In the following years the Fermilab Muon Campus will deliver highly polarized muon beams to the storage ring of the Muon g-2 Experiment. The transmission fraction of the storage ring has been shown to depend strongly on the transverse optics of the injected beam. Unfortunately, the current diagnostics in the Muon Campus allow only measurement of the beam configuration space which limits how well propagation can be predicted. This work demonstrates an experimental technique based on a conventional magnet scan to obtain the Twiss parameters at a point, using only beam profiles such that installation of new equipment is not required. A proof-of-principle experiment is presented which shows that this new method is applicable to the Muon Campus, offering a viable approach to optimization of injection in the Muon g-2 Experiment.

43 PARTICLE ACCELERATORS↗

Laser-scanning techniques for rapid ballistics identification

Two different laser-scanning methods may be utilized. In each case scanned cylindrical bullet surface is displayed ""unwrapped'' on oscilloscope screen. Bullets are compared by photographing each display and superimposing negatives of two images. With some modifications bullets can be scanned and compared by superimposing images on screen of dual-beam oscilloscope.

Woodburgy, R. C.↗

A planar near-field scanning technique for bistatic radar cross section measurements

A progress report on the development of a bistatic radar cross section (RCS) measurement range is presented. A technique using one parabolic reflector and a planar scanning probe antenna is analyzed. The field pattern in the test zone is computed using a spatial array of signal sources. It achieved an illumination pattern with 1 dB amplitude and 15 degree phase ripple over the target zone. The required scan plane size is found to be proportional to the size of the desired test target. Scan plane probe sample spacing can be increased beyond the Nyquist lambda/2 limit permitting constant probe sample spacing over a range of frequencies.

Tuhela-Reuning, S.↗

Assessment of Early Toxicity and Response in Patients Treated With Proton and Carbon Ion Therapy at the Heidelberg Ion Therapy Center Using the Raster Scanning Technique

Puropose: To asses early toxicity and response in 118 patients treated with scanned ion beams to validate the safety of intensity-controlled raster scanning at the Heidelberg Ion Therapy Center. Patients and Methods: Between November 2009 and June 2010, we treated 118 patients with proton and carbon ion radiotherapy (RT) using active beam delivery. The main indications included skull base chordomas and chondrosarcomas, salivary gland tumors, and gliomas. We evaluated early toxicity within 6 weeks after RT and the initial clinical and radiologic response for quality assurance in our new facility. Results: In all 118 patients, few side effects were observed, in particular, no high numbers of severe acute toxicity were found. In general, the patients treated with particle therapy alone showed only a few single side effects, mainly Radiation Therapy Oncology Group/Common Terminology Criteria grade 1. The most frequent side effects and cumulative incidence of single side effects were observed in the head-and-neck patients treated with particle therapy as a boost and photon intensity-modulated RT. The toxicities included common radiation-attributed reactions known from photon RT, including mucositis, dysphagia, and skin erythema. The most predominant imaging responses were observed in patients with high-grade gliomas and those with salivary gland tumors. For skull base tumors, imaging showed a stable tumor outline in most patients. Thirteen patients showed improvement of pre-existing clinical symptoms. Conclusions: Side effects related to particle treatment were rare, and the overall tolerability of the treatment was shown. The initial response was promising. The data have confirmed the safe delivery of carbon ions and protons at the newly opened Heidelberg facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed wide-angle interleaved scanning technique for a 3D imaging lidar

In this paper, we describe a novel interleaved scanner for an eye-safe 3D scanning lidar system to measure aerodynamic phenomena in a wind tunnel using elastic backscatter from seeding particles. The scanner assembly consists of a rotating polygon scanner for line scanning along the fast axis, a galvanometer (galvo) scanner for scanning along the slow axis, angular position sensors and motor controllers. The polygon scanner sweeps the lidar beam at up to 10,000 lines/s across a 27 deg angular field-of-regard in the fast axis, while the galvo scanner covers an angular range of 20 deg in the slow axis. Using this scanner, the lidar can perform non-intrusive flow visualization, velocimetry, and hard target mapping at mmscale spatial resolution to a standoff range of 5 m at an update rate of 50 Hz for the full field-of-regard. An interleaved scanning methodology for the acquisition of two snapshots of 3D lidar intensity data with a 100 μs time offset is discussed. The design of the control and data acquisition electronics is described. The effects of rapid scanning on the response of a narrow field-of-view lidar are addressed. The design of the scanner is scalable and can be tailored to meet the requirements of other applications by increasing or decreasing the standoff range, angular field-of-regard and scan rate.

3D Imaging Lidar↗

Effect of nonlinear absorption on electric field applied lead chloride by Z-scan technique

The preparation, spectral response and optical nonlinearity of gel grown lead chloride single crystals subjected to electric field of 20V using parallel plate arrangements have been investigated. Optical band gap of the samples were determined using linear absorption spectra. Open aperture z-scan was employed for the determination of nonlinear absorption coefficient of PbCl{sub 2} solution. The normalized transmittance curve exhibits a valley shows reverse saturable absorption. The non linear absorption at different input fluences were recorded using a single Gaussian laser beam in tight focus geometry. The RSA nature of the sample makes it suitable for optical limiting applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Algorithms for Estimating Spacecraft Position Using Scanning Techniques for Deep Space Network Antennas

As more and more nonlinear estimation techniques become available, our interest is in finding out what performance improvement, if any, they can provide for practical nonlinear problems that have been traditionally solved using linear methods. In this paper we examine the problem of estimating spacecraft position using conical scan (conscan) for NASA's Deep Space Network antennas. We show that for additive disturbances on antenna power measurement, the problem can be transformed into a linear one, and we present a general solution to this problem, with the least square solution reported in literature as a special case. We also show that for additive disturbances on antenna position, the problem is a truly nonlinear one, and we present two approximate solutions based on linearization and Unscented Transformation respectively, and one 'exact' solution based on Markov Chain Monte Carlo (MCMC) method. Simulations show that, with the amount of data collected in practice, linear methods perform almost the same as MCMC methods. It is only when we artificially reduce the amount of collected data and increase the level of noise that nonlinear methods show significantly better accuracy than that achieved by linear methods, at the expense of more computation.

Metropolis-Hastings (MH)↗

A new pulsed laser deposition technique: Scanning multi-component pulsed laser deposition method

The scanning multi-component pulsed laser deposition (PLD) method realizes uniform depositions of desired coatings by a modified pulsed laser deposition process, preferably with a femto-second laser-system. Multi-component coatings (single or multilayered) are thus deposited onto substrates via laser induced ablation of segmented targets. This is achieved via horizontal line-scanning of a focused laser beam over a uniformly moving target's surface. This process allows to deposit the desired composition of the coating simultaneously, starting from the different segments of the target and adjusting the scan line as a function of target geometry. The sequence and thickness of multilayers can easily be adjusted by target architecture and motion, enabling inter/intra layer concentration gradients and thus functional gradient coatings. This new, simple PLD method enables the achievement of uniform, large-area coatings. Case studies were performed with segmented targets containing aluminum, titanium, and niobium. Under the laser irradiation conditions applied, all three metals were uniformly ablated. The elemental composition within the rough coatings obtained was fixed by the scanned area to Ti-Al-Nb = 1:1:1. Crystalline aluminum, titanium, and niobium were found to coexist side by side at room temperature within the substrate, without alloy formation up to 600 deg. C.

36 MATERIALS SCIENCE↗

Profiling of the injected charge drift current transients by cross-sectional scanning technique

The electric field distribution and charge drift currents in Si particle detectors are analyzed. Profiling of the injected charge drift current transients has been implemented by varying charge injection position within a cross-sectional boundary of the particle detector. The obtained profiles of the induction current density and duration of the injected charge drift pulses fit well the simulated current variations. Induction current transients have been interpreted by different stages of the bipolar and monopolar drift of the injected carriers. Profiles of the injected charge current transients registered in the non-irradiated and neutron irradiated Si diodes are compared. It has been shown that the mixed regime of the competing processes of drift, recombination, and diffusion appears in the measured current profiles on the irradiated samples. The impact of the avalanche effects can be ignored based on the investigations presented. It has been shown that even a simplified dynamic model enabled us to reproduce the main features of the profiled transients of induced charge drift current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary investigation of pilot scanning techniques of dial pointing instruments

Two pilots' methods of looking at instruments with needle pointers in a fixed base helicopter simulation were observed. A total of 45 runs were analyzed for each pilot. The data indicated that two apparently different techniques were being used; one looking at the needle point, the other looking at a fixed spot on the instrument and reading the needle direction parafoveally. The latter technique is found to be somewhat faster with both pilots accomplishing the flying task.

Harris, R. L., Sr.↗