SEARCH · Search NASA
Results for “Secure by Design”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Select Generic Dry-Storage Pilot Plant Design for Safeguards and Security by Design (SSBD) per Used Fuel Campaign
As preparation to the year-end deliverable (Provide SSBD Best Practices for Generic Dry-Storage Pilot Scale Plant) for the Work Package (FT-15LA040501–Safeguards and Security by Design for Extended Dry Storage), the initial step was to select a generic dry-storage pilot plant design for SSBD. To be consistent with other DOE-NE Fuel Cycle Research and Development (FCR&D) activities, the Used Fuel Campaign was engaged for the selection of a design for this deliverable. For the work Package FT-15LA040501–“Safeguards and Security by Design for Extended Dry Storage”, SSBD will be initiated for the Generic Dry-Storage Pilot Scale Plant described by the layout of Reference 2. SSBD will consider aspects of the design that are impacted by domestic material control and accounting (MC&A), domestic security, and international safeguards.
Designing a Secure Storage Repository for Sharing Scientific Datasets using Public Clouds
As Cloud platforms gain increasing traction among scientific and business communities for outsourcing storage, computing and content delivery, there is also growing concern about the associated loss of control over private data hosted in the Cloud. In this paper, we present an architecture for a secure data repository service designed on top of a public Cloud infrastructure to support multi-disciplinary scientific communities dealing with personal and human subject data, motivated by the smart power grid domain. Our repository model allows users to securely store and share their data in the Cloud without revealing the plain text to unauthorized users, the Cloud storage provider or the repository itself. The system masks file names, user permissions and access patterns while providing auditing capabilities with provable data updates.
Security By Design: Project Overview and Security Assessment Process.
Abstract not provided.
Security by Design: Project Overview and Security Assessment Process.
Abstract not provided.
Review Facility Design Drawings M3FT-16LA040105011 - Safeguards and Security by Design for Used Fuel Extended Storage: 1.02.04.01.05 FT – 16LA04010501
This work package focuses on developing Best Practices for the design of security for, and domestic safeguarding (e.g. MC&A) of, a pilot-scale independent spent/used fuel storage facility consistent with conceptual design efforts in Nuclear Fuels Storage and Transportation (NFST) and Used Fuel Disposal (UFD) campaigns. This is a review of the basic design of the facility to determine a candidate list of accounting and control requirements that could be considered for safeguards and security purposes.
ARC-100 Reactor Security-by-Design Summary
This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the Advanced Reactor Concepts 100 (ARC-100) sodium-cooled fast reactor (SFR) design. The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, and used fuel assembly wash station. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. However, the consequence assessment results are the similar to a previously assessed generic SFR. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. This work will continue in the Fiscal Year 2025 for the remaining ARC-100 systems, including cesium trap, sodium cold trap, noble gas decay tanks (dewar bottles), and used fuel dry storage facility, to provide safety-and-security-by-design insights and recommendations on non-core systems. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.
The MPACT 2020 Milestone: Safeguards and Security by Design of Future Nuclear Fuel Cycle Facilities.
The Materials Protection, Accounting, and Control Technologies (MPACT) campaign, within the U.S. Department of Energy Office of Nuclear Energy, has developed a Virtual Facility Distributed Test Bed for safeguards and security design for future nuclear fuel cycle facilities. The purpose of the Virtual Test Bed is to bring together experimental and modeling capabilities across the U.S. national laboratory and university complex to provide a one-stop-shop for advanced Safeguards and Security by Design (SSBD). Experimental testing alone of safeguards and security technologies would be cost prohibitive, but testbeds and laboratory processing facilities with safeguards measurement opportunities, coupled with modeling and simulation, provide the ability to generate modern, efficient safeguards and security systems for new facilities. This Virtual Test Bed concept has been demonstrated using a generic electrochemical reprocessing facility as an example, but the concept can be extended to other facilities. While much of the recent work in the MPACT program has focused on electrochemical safeguards and security technologies, the laboratory capabilities have been applied to other facilities in the past (including aqueous reprocessing, fuel fabrication, and molten salt reactors as examples). This paper provides an overview of the Virtual Test Bed concept, a description of the design process, and a baseline safeguards and security design for the example facility. Parallel papers in this issue go into more detail on the various technologies, experimental testing, modeling capabilities, and performance testing.
ARC-100 Reactor Security-by-Design Summary 2025
This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the ARC-100, a sodium-cooled fast reactor (SFR) being developed by ARC Clean Technology, Inc (ARC). The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, used fuel assembly wash station, cesium trap, sodium cold trap, noble gas decay tanks, used fuel dry storage facility, damaged fuel storage facility, and radioactive waste building. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.
Exploring Operational Safeguards, Safety, and Security by Design to Address Real Time Threats in Nuclear Facilities
Over the last few years, significant attention has been paid to both encourage application and provide domestic and international guidance for designing in safeguards and security in new facilities.1,2,3 However, once a facility is operational, safeguards, security, and safety often operate as separate entities that support facility operations. This separation is potentially a serious weakness should insider or outsider threats become a reality.Situations may arise where safeguards detects a possible loss of material in a facility. Will they notify security so they can, for example, check perimeter doors for tampering? Not doing so might give the advantage to an insider who has already, or is about to, move nuclear material outside the facility building. If outsiders break into a facility, the availability of any information to coordinate the facility’s response through segregated alarm stations or a failure to include all available radiation sensors, such as safety’s criticality monitors can give the advantage to the adversary who might know to disable camera systems, but would most likely be unaware of other highly relevant sensors in a nuclear facility.This paper will briefly explore operational safeguards, safety, and security by design (3S) at a high level for domestic and State facilities, identify possible weaknesses, and propose future administrative and technical methods, to strengthen the facility system’s response to threats.
Security by Design Handbook
This document is a draft Security-by-Design (SeBD) handbook produced to support the Work Plan of the Nuclear Security Summit to share best practices for nuclear security in new facility design. The Work Plan calls on States to “encourage nuclear operators and architect/engineering firms to take into account and incorporate, where appropriate, effective measures of physical protection and security culture into the planning, construction, and operation of civilian nuclear facilities and provide technical assistance, upon request, to other States in doing so.” The materials for this document were generated primarily as part of a bilateral project to produce a SeBD handbook as a collaboration between the Japan Atomic Energy Agency (JAEA) Nuclear Nonproliferation Science and Technology Center and Sandia National Laboratories (SNL), which represented the US Department Energy (DOE) National Nuclear Security Administration (NNSA) under a Project Action Sheet PAS-PP04. Input was also derived based on tours of the Savannah River Site (SRS) and Japan Nuclear Fuel Limited (JNFL) Rokkasho Mixed Oxide Fuel fabrication facilities and associated project lessons-learned. For the purposes of the handbook, SeBD will be described as the system-level incorporation of the physical protection system (PPS) into a new nuclear power plant or nuclear facility resulting in a PPS design that minimizes the risk of malicious acts leading to nuclear material theft; nuclear material sabotage; and facility sabotage as much as possible through features inherent in (or intrinsic to) the design of the facility. A four-element strategy is presented to achieve a robust, durable, and responsive security system.
Engagement Activities on Safeguards & Security by Design (SSBD) for Used Fuel Extended Storage
This report emphasizes some best practice techniques for the design of and security for domestic safeguards of a pilot-scale, independent, spent/used fuel storage facility.
Development of a security-by-design handbook.
There is an increasing awareness that efficient and effective nuclear facility design is best achieved when requirements from the 3S disciplines Safety, Safeguards, and Security - are balanced and intrinsic to the facility design. This can be achieved when policy, processes, methods, and technologies are understood and applied in these areas during all phases of the design process. For the purposes of this paper, Security-by-design will be defined as the system level incorporation of the physical protection system (PPS) into a new or retrofitted nuclear power plant (NPP) or nuclear facility (NF) resulting in intrinsic security. Security-by-design can also be viewed as a framework to achieve robust and durable security systems. This paper reports on work performed to date to create a Security-by-Design Handbook, under a bilateral agreement between the United States and Japan, specifically, a review of physical protection principles and best practices, and a decommissioning to better understand where these principles and practices can be applied. This paper describes physical protection principles and best practices to achieve security-by- design that were gathered from International, Japanese, and U.S. sources. Principles are included for achieving security early in the design process where security requirements are typically less costly and easier to incorporate. The paper then describes a generic design process that covers the entire facility lifecycle from scoping and planning of the project to decommissioning and decontamination. Early design process phases, such as conceptual design, offer opportunities to add security features intrinsic to the facility design itself. Later phases, including design engineering and construction, are important for properly integrating security features into a coherent design and for planning for and assuring the proper performance of the security system during the operation and decommissioning of the facility. The paper also describes some future activities on this bilateral project to create a Security-by-Design Handbook. When completed, the Handbook is intended to assist countries with less experience in nuclear power programs to apply principles and best practices in an effective and efficient manner as early in the design as possible to achieve robust and durable security.
Oak Ridge National Laboratory Security by Design: A Plant Design and Component-Based Approach to Technical Solutions to Insider and Outsider Threat
Security costs for nuclear reactors have been shown to rise over the lifecycle of a nuclear facility as new threats, security weaknesses, and the generic threat profile of the plant location change over time. This paper conducts a review of the technological gaps that currently exist in Security by Design (SeBD) based on the literature available and attempts to close those gaps through proposing technological constructs and processes that can integrate safety and security in the design process of a plant, with a primary focus on SMR technology. Under the new modular and mass manufacturing regime, where plant designs attempt to reduce costs with potential economies of scale and modular construction, the current SeBD definitions focusing on state level regulators are not considered adequate since the licensing stage is often too late in the design process to integrate the true cost savings of SeBD. Thus, this paper attempts to remedy the current logic in order to allow for continuous implementation of security alongside the development of the safety concept for the plant. If adopted within the design process the establishment of this type of technology will allow for a technological ecosystem to evolve that will imbed security concepts into the physical design of the components of the plant.
Safeguards and Security by Design (SSBD) for Small Modular Reactors (SMRs) through a Common Global Approach
Small Modular Reactors (SMR) with power levels significantly less than the currently standard 1000 to 1600-MWe reactors have been proposed as a potential game changer for future nuclear power. SMRs may offer a simpler, more standardized, and safer modular design by using factory built and easily transportable components. Additionally, SMRs may be more easily built and operated in isolated locations, and may require smaller initial capital investment and shorter construction times. Because many SMRs designs are still conceptual and consequently not yet fixed, designers have a unique opportunity to incorporate updated design basis threats, emergency preparedness requirements, and then fully integrate safety, physical security, and safeguards/material control and accounting (MC&A) designs. Integrating safety, physical security, and safeguards is often referred to as integrating the 3Ss, and early consideration of safeguards and security in the design is often referred to as safeguards and security by design (SSBD). This paper describes U.S./Russian collaborative efforts toward developing an internationally accepted common approach for implementing SSBD/3Ss for SMRs based upon domestic requirements, and international guidance and requirements. These collaborative efforts originated with the Nuclear Energy and Nuclear Security working group established under the U.S.-Russia Bilateral Presidential Commission during the 2009 Presidential Summit. Initial efforts have focused on review of U.S. and Russian domestic requirements for Security and MC&A, IAEA guidance for security and MC&A, and IAEA requirements for international safeguards. Additionally, example SMR design features that can enhance proliferation resistance and physical security have been collected from past work and reported here. The development of a U.S./Russian common approach for SSBD/3Ss should aid the designer of SMRs located anywhere in the world. More specifically, the application of this approach may lead to more proliferation resistant and physically secure design features for SMRs.