Search NASA⌕ Search

SEARCH · Search NASA

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Soft x-ray intensity profile measurements of electron cyclotron heated plasmas using semiconductor detector arrays in GAMMA 10 tandem mirror

Temporally and spatially resolved soft x-ray analyses of electron cyclotron heated plasmas are carried out by using semiconductor detector arrays in the GAMMA 10 tandem mirror. The detector array has 16-channel for the measurements of plasma x-ray profiles so as to make x-ray tomographic reconstructions. The characteristics of the detector array make it possible to obtain spatially resolved plasma electron temperatures down to a few tens eV and investigate various magnetohydrodynamic activities. High power electron cyclotron heating experiment for the central-cell region in GAMMA 10 has been started in order to reduce the electron drag by increasing the electron temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

[{sup 18}F]fluoromisonidazole and a New PET System With Semiconductor Detectors and a Depth of Interaction System for Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer

Purpose: The impact of a new type of positron emission tomography (New PET) with semiconductor detectors using {sup 18}F-labeled fluoromisonidazole (FMISO)-guided intensity modulated radiation therapy (IMRT) was compared with a state-of-the-art PET/computed tomography (PET/CT) system in nasopharyngeal cancer (NPC) patients. Methods and Materials: Twenty-four patients with non-NPC malignant tumors (control group) and 16 patients with NPC were subjected to FMISO-PET. The threshold of the tumor-to-muscle (T/M) ratio in each PET scan was calculated. The hypoxic volume within the gross tumor volume (GTVh) was determined using each PET ({sub NewPET}GTVh and {sub PET/CT}GTVh, respectively). Dose escalation IMRT plans prescribing 84 Gy to each GTVh were carried out. Results: The threshold of the T/M ratio was 1.35 for New PET and 1.23 for PET/CT. The mean volume of {sub NewPET}GTVh was significantly smaller than that of {sub PET/CT}GTVh (1.5 {+-} 1.6 cc vs 4.7 {+-} 4.6 cc, respectively; P=.0020). The dose escalation IMRT plans using New PET were superior in dose distribution to those using PET/CT. Dose escalation was possible in all 10 New PET-guided plans but not in 1 PET/CT-guided plan, because the threshold dose to the brainstem was exceeded. Conclusions: New PET was found to be useful for accurate dose escalation in FMISO-guided IMRT for patients with NPC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrodeposition of Actinides on a Semiconductor Detector for Concentration Monitoring

Pyroprocessing is a promising technology for separation and recycle of actinides from spent nuclear fuel. It is being actively researched in the United States as well as the Republic of Korea for possible implementation into a closed nuclear fuel cycle. The features of the chemical technology behind pyro-processing, unfortunately, present difficulties for real time accounting of actinides. Development of optimal process monitoring technology and safeguards approaches are, thus, a high priority for completing the development of the overall process technology. Real time monitoring of actinide concentrations in the molten salt electro-refiners is particularly important to achieve because of the potential for multiple significant quantities of plutonium in the molten salt. To address this need, development of a semiconductor detector for real-time monitoring of actinides in molten chloride salt (LiCl-KCl) is being conducted. Towards this end, a novel alpha spectroscopy detection system is being developed using wide band-gap semiconductor material, such as GaN or SiC, with a Boron-Doped-Diamond (BDD) contact. The objective is to deposit a thin layer of actinides onto the BDD layer, which will be used to measure the alpha particle spectrum that will distinguish individual actinides and their concentration. In the first stage, the actinide electrodeposition onto a surrogate material for the detector has been undertaken. While this project is in its very early states, a couple of observations have been made. One is that the electrodeposition is a slow, diffusion-controlled process. Therefore the deposit should be as thin (≅1 m) as the alpha spectroscopy permits (the resolution gets inferior with lesser number of atoms). Also, applied potentials should not be too negative; otherwise the deposit does not adhere well to the surface. The application of this method to measuring actinides in molten salt appears to be feasible, and a considerable amount of further investigation is planned. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wide Bandgap Semiconductor Detector Optimization for Flash X-Ray Measurements

Charge trapping, resulting in a decreased and spatially dependent electric field, has long been a concern for wide bandgap semiconductor detectors. While significant work has been performed to characterize this degradation at varying temperatures and radiation environments, this work concentrates upon examining the event-to-event response in a flash X-ray environment. The following work investigates if charge trapping is a problem for CZT detectors, with particular emphasis on flash X-ray radiation fields at cold temperatures. Results are compared to a non-flash radiation field, using an Am-241 alpha source and similar temperature transitions. Our ability to determine if a response change occurred was hampered by the repeatability of our flash X-ray systems; a small response change was observed with the Am-241 source. Due to contrast of these results, we are in the process of revisiting the Am-241 measurements in the presence of a high radiation environment. If the response change is more pronounced in the high radiation environment, a similar test will be performed in the flash X-ray environment.

47 OTHER INSTRUMENTATION↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

Identifying new semiconductor detector materials by D.C. ionization conductivity

Herein is described a method for identifying semiconductor radiation detector materials based on the mobility of internally generated electrons and holes. It was designed for the early stages of exploration, when samples are not available as single crystals, but as crystalline powders. Samples are confined under pressure in an electric field and the increase in current resulting from exposure to a high-intensity source of ionization current (e.g., 60Co gamma rays) is measured. A pressure cell device is described herein to carry out the method. For known semiconductors, the d.c. ionization current depends on voltage according to the Hecht equation, and for known insulators the d.c. ionization current is below detection limits. This shows that the method can identify semiconductors in spite of significant carrier trapping. Using this method and pressure cell, it was determined that new materials BiOI, PbIF, BiPbO2Cl, BiPbO2Br, BiPbO2I, Bi2GdO4Cl, Pb3O2I2, and Pb5O4I2 are semiconductors.

36 MATERIALS SCIENCE↗

Multichannel, time-resolved picosecond laser ultrasound imaging and spectroscopy with custom complementary metal-oxide-semiconductor detector

This paper presents a multichannel, time-resolved picosecond laser ultrasound system that uses a custom complementary metal-oxide-semiconductor linear array detector. This novel sensor allows parallel phase-sensitive detection of very low contrast modulated signals with performance in each channel comparable to that of a discrete photodiode and a lock-in amplifier. Application of the instrument is demonstrated by parallelizing spatial measurements to produce two-dimensional thickness maps on a layered sample, and spectroscopic parallelization is demonstrated by presenting the measured Brillouin oscillations from a gallium arsenide wafer. This paper demonstrates the significant advantages of our approach to pump probe systems, especially picosecond ultrasonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microelectronics used for Semiconductor Imaging Detectors

Semiconductor crystal technology, microelectronics developments and nuclear particle detection have been in a relation of symbiosis, all the way from the beginning. The increase of complexity in electronics chips can now be applied to obtain much more information on the incident nuclear radiation. Some basic technologies are described, in order to acquire insight in possibilities and limitations for the most recent detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of dose measurements in CT using a novel semiconductor detector and a small ion chamber

The advance of multislice computed tomography (CT) has become inadequate the currently dosimetric protocol used in CT. Instead of dosimetry based on the measurement of CTDI using a pencil ion chamber of 100 m of length, it was proposed the use of a small ion chamber (IC) and the calculating the dose equilibrium (Deq) at the location of the chamber. The objective of this work was to compare the performance of a short IC and a commercial photodiode to measure the accumulated dose at the center of the scan length L, DL(0), and to obtain the equilibrium dose Deq using the two detectors. The result for L=100 mm was compared with the result of a pencil chamber. The results indicate that the commercial photodiode is suitable to measure the accumulated dose at the center of the scan length L as compared with the ion chambers. This methodology allows measurements of the accumulated dose for any desired scan length, allowing measuring the equilibrium dose Deq if the phantom is long enough to allow it. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗