Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MCNP6 Status and plans for criticality safety applications - 14368

The first production version of MCNP6 was released in 2013, with an update in 2014. MCNP6 provides all of the standard methodology for criticality calculations available in previous versions and new capabilities for adjoint-based sensitivity profiles and perturbations. This paper reviews the current status of MCNP6, including new features, performance improvements, verification testing, and nuclear data libraries. For criticality safety support, a new statistical package called Whisper was developed and first applied in 2014 for validation and determining USLs. Whisper includes input files and sensitivity profiles for over 1000 ICSBEP benchmarks and will be distributed with MCNP6. For the long term, an initiative called MCNP 2020 is underway to improve performance, strengthen the code foundation, and prepare for future computer systems. (authors)

42 ENGINEERING↗

Use of Covariance Data to Select Experiments Relevant to Target Systems for GNEP

The relevance of selected experiments to specific GNEP target systems is investigated with the use of representativity methods. In this approach, the similarity between the target system and selected experiments in connection with a response parameter of interest is quantitatively evaluated by comparing the sensitivity profiles of the response parameter with respect to the nuclear data in the two systems, filtered by the estimated covariance data.

99 GENERAL AND MISCELLANEOUS↗

A simple json format for storing and exchanging code calculation and experimental results

Calculation codes and code systems give their results in a plethora of different formats and/or files. For instance, MCNP gives a user the MCNP specific output file, the mctal file, the ptrac file, etc. while PARTISN has a PARTISN specific output file and a number of binary files with various kinds of information about the calculation. However, the results we are interested in are always the same. These can be single values such as the effective multiplication factor k eff or the effective delayed neutron fraction β eff . It can be histogram data (such as particle spectra, reaction rates, sensitivity profiles, etc.) or even pointwise data (for example the nuclide composition as a function of time, etc.). It is also worthwhile to note that this would also apply to experimental data that we may wish to compare with as well. Calculation and experimental results can basically be split into two components: attributes (or metadata) and the actual result itself. Attributes represent information about the result that are not necessarily required for its’ interpretation but that are still good to have. Often, these attributes are what we will want to filter results on. This means that these attributes are often the answer to specific questions we may have about the result. The following is a non exhaustive list of such basic questions: what type of result is it: e.g. the effective multiplication factor k eff , the effective delayed neutron fraction β eff , etc.; which case does it relate to: e.g. a specific ICSBEP case such as PU-MET-FAST-001-001; which code and version produced this result: e.g. MCNP 6.2, etc.; which nuclear data library was used to obtain the result: e.g. ENDF/B-VIII.0 or JEFF 3.3; which nuclide and reaction does it apply to (for reaction rates and sensitivity profiles); which volume in the geometry was it calculated in? The second component of the calculation or experimental result is the actual numerical data of the result. It is this data that we want to compare, exchange, plot, interpret, etc. It consists of values with optional uncertainties and units. It also includes the underlying structure (if any structure is required to interpret the result). Depending on the type of result, it may be a single value (e.g. the effective multiplication factor), an array of values (e.g. a reaction rate or particle spectrum) or even a multidimensional array. In order to exchange results between different organisations, for instance for benchmarking, people often resort to spreadsheets or custom text files that need to be filled out. While this approach works well if little information is to be exchanged, it can become cumbersome when dealing with large amounts of data (like for instance particle spectra for thousands of cases). In addition, such an approach does not always capture the metadata we may be interested in to allow for automated processing of these files. The purpose of this report is to propose a standardised json structure to store any type of result and present an associated python interface to interact with these results directly. For such a structure to be useful, it must fulfill a specific set of functional requirements that we try to meet with this proposal. The format must allow for the calculation result to stand by itself. This means that we should not have to look in multiple places to be able to understand it. For example, if the result relates to a particle spectrum, the group structure in which the result is given should be stored with it. The format should be code agnostic. This means that we do not need to know where it came from to understand it. The format should be result type agnostic. This means that the format must be generic enough so that we can even use it for results we have not thought of yet. The format should be relatively easy to interact with through different scripting or programming languages (i.e. the machine interface) while still providing a clean structure that can be used directly by any human.

97 MATHEMATICS AND COMPUTING↗

Adaptive nonlocal means filtering based on local noise level for CT denoising

Purpose: To develop and evaluate an image-domain noise reduction method based on a modified nonlocal means (NLM) algorithm that is adaptive to local noise level of CT images and to implement this method in a time frame consistent with clinical workflow. Methods: A computationally efficient technique for local noise estimation directly from CT images was developed. A forward projection, based on a 2D fan-beam approximation, was used to generate the projection data, with a noise model incorporating the effects of the bowtie filter and automatic exposure control. The noise propagation from projection data to images was analytically derived. The analytical noise map was validated using repeated scans of a phantom. A 3D NLM denoising algorithm was modified to adapt its denoising strength locally based on this noise map. The performance of this adaptive NLM filter was evaluated in phantom studies in terms of in-plane and cross-plane high-contrast spatial resolution, noise power spectrum (NPS), subjective low-contrast spatial resolution using the American College of Radiology (ACR) accreditation phantom, and objective low-contrast spatial resolution using a channelized Hotelling model observer (CHO). Graphical processing units (GPU) implementation of this noise map calculation and the adaptive NLM filtering were developed to meet demands of clinical workflow. Adaptive NLM was piloted on lower dose scans in clinical practice. Results: The local noise level estimation matches the noise distribution determined from multiple repetitive scans of a phantom, demonstrated by small variations in the ratio map between the analytical noise map and the one calculated from repeated scans. The phantom studies demonstrated that the adaptive NLM filter can reduce noise substantially without degrading the high-contrast spatial resolution, as illustrated by modulation transfer function and slice sensitivity profile results. The NPS results show that adaptive NLM denoising preserves the shape and peak frequency of the noise power spectrum better than commercial smoothing kernels, and indicate that the spatial resolution at low contrast levels is not significantly degraded. Both the subjective evaluation using the ACR phantom and the objective evaluation on a low-contrast detection task using a CHO model observer demonstrate an improvement on low-contrast performance. The GPU implementation can process and transfer 300 slice images within 5 min. On patient data, the adaptive NLM algorithm provides more effective denoising of CT data throughout a volume than standard NLM, and may allow significant lowering of radiation dose. After a two week pilot study of lower dose CT urography and CT enterography exams, both GI and GU radiology groups elected to proceed with permanent implementation of adaptive NLM in their GI and GU CT practices. Conclusions: This work describes and validates a computationally efficient technique for noise map estimation directly from CT images, and an adaptive NLM filtering based on this noise map, on phantom and patient data. Both the noise map calculation and the adaptive NLM filtering can be performed in times that allow integration with clinical workflow. The adaptive NLM algorithm provides effective denoising of CT data throughout a volume, and may allow significant lowering of radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytic Sensitivity Coefficients for General Multigroup Infinite Medium k-Eigenvalue Problems

The general multigroup infinite medium k-eigenvalue neutron transport equation is used to derive analytic expressions for the infinite medium k-eigenvalue, the scalar neutron flux and adjoint, and the sensitivity of $k$ ∞ to perturbations in the multigroup nuclear data of a single species isotropic elastic scattering material. In the appendix, we present the multigroup nuclear data for U-235 and U-238 along with the corresponding k-eigenvalue, flux, adjoint, and sensitivity profiles, which include the sensitivity of $k$ ∞ to the total, fission, capture, and scattering macroscopic cross sections as well as to the group-to-group scattering cross section matrix, group neutron production, and the unconstrained and constrained fission neutron energy distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analytic Sensitivity Coefficients for General Multigroup Infinite Medium k-Eigenvalue Problems

This work presents a general set of equations that can be used to rapidly generate new benchmarks to verify nuclear data sensitivity calculations. The general multigroup infinite medium k-eigenvalue neutron transport equation is used to derive analytic expressions for the infinite medium k-eigenvalue, the scalar neutron flux and adjoint flux, and the sensitivity of k∞ to perturbations in the multigroup nuclear data of a single species, isotropic and elastic scattering, material. The multigroup nuclear data for U-235 and U-238 is presented along with their corresponding k-eigenvalues, forward flux, adjoint flux, and sensitivity profiles, which include the sensitivity of k∞ to the total, fission, capture, and scattering macroscopic cross sections as well as to the group-to-group scattering cross section matrix, group-wise fission neutron production, and the unconstrained and constrained fission neutron energy distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Which nuclear data can be validated with LLNL pulsed-sphere experiments?

It is shown here that 14-MeV D+T LLNL pulsed-sphere experiments bring complementary information into the process of validating nuclear data compared to experiments that are traditionally used for this purpose—such as critical assemblies. To be more specific, the 14-MeV D+T LLNL pulsed-sphere neutron-leakage spectra enable to validate scattering and fission nuclear data up to 15 MeV (compared to approximately up to 5 MeV when using criticality experiments) and employ to this end simple compound targets containing only few isotopes. In this work, sensitivity profiles of the spectra to nuclear data are calculated in order to understand in detail which isotopes, observables, and energy ranges of nuclear data contribute significantly to their simulation. These profiles are presented for a few selected spheres containing 16 O, 12 C, 56 Fe, and 239 Pu. It is shown that the neutron-leakage spectra of spheres containing light elements are mostly sensitive to elastic- and inelastic-scattering cross sections on discrete levels and corresponding angular distributions. Spheres of structural materials are sensitive to elastic- and inelastic-scattering cross sections, including scattering on discrete levels and the continuum, and double-differential cross sections. Actinide spheres are also strongly sensitive to the fission observables, in particular to the total-fission neutron spectrum. Thin spheres (in which neutrons experience on average less than one scatter) are mostly sensitive to data near the elastic peak, in the energy range from 12–15 MeV, while thicker ones can be sensitive to data at lower incident-neutron energies due to multiple-scattering effects. This information is brought together with simulations of 71 pulsed-sphere neutron-leakage spectra using the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear-data libraries. This analysis highlights ENDF/B-VIII.0 data that could be further investigated for potential shortcomings ( 6 Li, 12 C, 16 O, 24-26 Mg, 27 Al, 48 Ti, 56 Fe, and 208 Pb) or are likely reliable ( 1,2 H, 7 Li, 9 Be, 14 N, 235,238 U, and 239 Pu) as indicated by validating with LLNL pulsed-sphere experiments.

14-MeV D+T LLNL pulsed-sphere neutron-leakage spec↗

Materials science applications of Neutron Depth Profiling at the PGAA facility of Heinz Maier-Leibnitz Zentrum

Highlights: • Exploiting the range of NDP from thin films to electrodes for Li-ion batteries • Adopting an analytical method to probe undisturbed depth profiles from thick films • Revealing depth-dependent lithium immobilization in Li-ion battery electrodes Neutron depth profiling (NDP) is a non-destructive, isotope-sensitive profiling technique to monitor concentration profiles in almost any material matrix. Since NDP is sensitive to {sup 6}Li and lithium is widely used for different material science applications such as ceramics, optical waveguides or energy-storage systems, NDP offers answers to a broad spectrum of research questions. In the present work, the recently developed instrument N4DP at MLZ is used to address two research questions which are hardly accessible by conventional analytical techniques. First, the homogeneity of lithium formations within lithium niobate thin films for optical waveguide applications is investigated. Afterwards, the accumulation of inactive lithium in the solid-electrolyte-interphase (SEI) of silicon-graphite electrodes for lithium-ion batteries is studied ex situ. Since the material mass loading differs considerably between the two applications, a new analytical technique is introduced which mathematically separates the different particle signals and thus allows to investigate samples with high mass loadings.

36 MATERIALS SCIENCE↗

Impact of Thermal Scattering Law on Similarity Assessment in Light-Water or Polyethylene-Moderated Systems [Slides]

This presentation found validation efforts revealed noticeable differences in c k for light-water and polyethylene moderated systems when compared to PST-002-001. Additionally, although 1 H-H 2 O and 1 H-poly use the same cross section and covariance data, the treatment of TSLs in SCALE lead to no contribution to ck between polyethylene application and benchmark experiment. When H 2 O contribution were removed the difference in c k appears to come from 239 Pu chi. Sensitivity profiles and data-induced uncertainty confirmed that the polyethylene application was more closely resembling the benchmark experiment. Specific differences between similar systems can be accounted for and examined to help understand differences in similarity (c k ) between systems was a conclusion reached by this presentation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sampling and position effects in the Electronically Steered Thinned Array Radiometer (ESTAR)

A simple engineering level model of the Electronically Steered Thinned Array Radiometer (ESTAR) is developed that allows an identification of the major effects of the sampling process involved with this technique. It is shown that the ESTAR approach is sensitive to aliasing and has a highly non-uniform sensitivity profile. It is further shown that the ESTAR approach is strongly sensitive to position displacements of the low-density sampling antenna elements.

Katzberg, Stephen J.↗

On the characterization of biases arising from methods and approximations used for sensitivity analyses

The preliminary assessment of the performance and safety of advanced reactors, as well as the identification of research and development needs, rely on computer simulations due to the lack of operational experience. Those simulations should be based on verified and validated computational tools, calculation schemes, and nuclear data libraries, and should be accompanied of a proper characterization of the involved uncertainties, providing confidence in the computational-based predictions. Thus, sensitivity and uncertainty studies, together with integral experiments, play an essential role in that process. Sensitivities are then a critical element and guidelines about how to produce accurate enough sensitivities depending on the subsequent analyses to be performed are of interest. The present study addresses the sensitivities biases arising from the use of different nuclear data libraries, computational methods and the assumption of modelling simplifications. Not only sensitivities for multiplication factor but also for safety-relevant reactivity responses have been analyzed. In the study, propagated uncertainties are also included for the considered parameters to illustrate the impact of the sensitivity profiles obtained for each case on the final uncertainty. Then, relevant recommendations are given for sensitivity analyses of highly complex systems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Depletion GPT-free sensitivity analysis for reactor eigenvalue problems

This manuscript introduces a novel approach to solving depletion perturbation theory problems without the need to set up or solve the generalized perturbation theory (GPT) equations. The approach, hereinafter denoted generalized perturbation theory free (GPT-Free), constructs a reduced order model (ROM) using methods based in perturbation theory and computes response sensitivity profiles in a manner that is independent of the number or type of responses, allowing for an efficient computation of sensitivities when many responses are required. Moreover, the reduction error from using the ROM is quantified in the GPT-Free approach by means of a Wilks' order statistics error metric denoted the K-metric. Traditional GPT has been recognized as the most computationally efficient approach for performing sensitivity analyses of models with many input parameters, e.g. when forward sensitivity analyses are computationally intractable. However, most neutronics codes that can solve the fundamental (homogenous) adjoint eigenvalue problem do not have GPT capabilities unless envisioned during code development. The GPT-Free approach addresses this limitation by requiring only the ability to compute the fundamental adjoint. This manuscript demonstrates the GPT-Free approach for depletion reactor calculations performed in SCALE6 using the 7x7 UAM assembly model. A ROM is developed for the assembly over a time horizon of 990 days. The approach both calculates the reduction error over the lifetime of the simulation using the K-metric and benchmarks the obtained sensitivities using sample calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of intrinsic magnetostriction on tube-topology magnetoelectric sensors with high magnetic field sensitivity

Three quasi-one-dimensional magnetoelectric (ME) magnetic field sensors, each with a different magnetostrictive wire material, were investigated in terms of sensitivity and noise floor. Magnetostrictive Galfenol, iron-cobalt-vanadium, and iron-nickel wires were examined. Sensitivity profiles, hysteresis effects, and noise floor measurements for both optimally biased and zero-biased conditions are presented. The FeNi wire (FN) exhibits high sensitivity (5.36 mV/Oe) at bias fields below 22 Oe and an optimal bias of 10 Oe, whereas FeGa wire (FG) exhibits higher sensitivity (6.89 mW/Oe) at bias fields >22 Oe. The sensor of FeCoV wire (FC) presents relatively low sensitivity (2.12 mV/Oe), due to low magnetostrictive coefficient. Each ME tube-topology sensor demonstrates relatively high sensitivity at zero bias field, which results from a magnetic shape anisotropy and internal strain of the thin magnetostrictive wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convective cloud vertical velocity and mass-flux characteristics from radar wind profiler observations during GoAmazon2014/5: VERTICAL VELOCITY GOAMAZON2014/5

A radar wind profiler data set collected during the 2 year Department of Energy Atmospheric Radiation Measurement Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) campaign is used to estimate convective cloud vertical velocity, area fraction, and mass flux profiles. Vertical velocity observations are presented using cumulative frequency histograms and weighted mean profiles to provide insights in a manner suitable for global climate model scale comparisons (spatial domains from 20 km to 60 km). Convective profile sensitivity to changes in environmental conditions and seasonal regime controls is also considered. Aggregate and ensemble average vertical velocity, convective area fraction, and mass flux profiles, as well as magnitudes and relative profile behaviors, are found consistent with previous studies. Updrafts and downdrafts increase in magnitude with height to midlevels (6 to 10 km), with updraft area also increasing with height. Updraft mass flux profiles similarly increase with height, showing a peak in magnitude near 8 km. Downdrafts are observed to be most frequent below the freezing level, with downdraft area monotonically decreasing with height. Updraft and downdraft profile behaviors are further stratified according to environmental controls. These results indicate stronger vertical velocity profile behaviors under higher convective available potential energy and lower low-level moisture conditions. Sharp contrasts in convective area fraction and mass flux profiles are most pronounced when retrievals are segregated according to Amazonian wet and dry season conditions. During this deployment, wet season regimes favored higher domain mass flux profiles, attributed to more frequent convection that offsets weaker average convective cell vertical velocities.

54 ENVIRONMENTAL SCIENCES↗

Application of Machine Learning Algorithms to Identify Problematic Nuclear Data

In this work we aim to show that Machine learning algorithms are promising tools for the identification of nuclear data that contribute to increased errors in transport simulations. We demonstrate this through an application of a machine learning algorithm (Random Forest) to the Whisper/MCNP6 criticality validation library to identify nuclear data that are associated with an increase of the bias (simulated - experimental $k_{eff}$) in the calculations. Specifically, the $k_{eff}$ sensitivity profiles (w.r.t. nuclear data) of 233 U solution benchmarks are used to predict the bias and Shapley Additive Explanations (SHAP) are used to explain how the sensitivities are related to the predicted bias. The SHAP values can be interpreted as sensitivity coefficients of the machine learning model to the $k_{eff}$ sensitivities which are used to make predictions of bias. Using the SHAP values we can identify specific subsets of nuclear data which have the highest probability of influencing bias. We demonstrate the utility of this method by showing how SHAP values were used to identify an inconsistency in the 19 F inelastic scattering nuclear data. The methodology presented here is not limited to transport problems and can be applied to other simulations if there are experimental measurements to compare against, simulations of those experimental measurements, and the ability to calculate sensitivities of the model output with respect to the data inputs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Coefficients Calculated for the Prompt Neutron Decay Constant At or Near Delayed Critical

The derivation of a non-invasive prompt neutron decay constant sensitivity coefficient is provided in this work. The computation of the sensitivity coefficient derived in this work does not require modification of Monte Carlo source code and is based on capabilities available in Monte Carlo N-Particle R© Code Version 6.2. The prompt neutron decay constant sensitivity coefficients are calculated for 44-group and 252-group energy structures for specific nuclide-reaction pairs in the Jezebel benchmark experiment. The nuclide-reaction pairs investigated in this work include Pu- 239(n,f), Pu-240(n,f), and Pu-241(n,f). Physical explanations of the sensitivity profiles exhibited by the 252-group energy structure are investigated for the prompt neutron multiplication factor, mean neutron lifetime, and prompt neutron decay constant. The prompt neutron decay constant sensitivity coefficients calculated for the 44-group and 252-group energy structure of Pu-239(n,f) are compared. Lastly, the 44-group energy structure sensitivity coefficients calculated are used for nuclear-data induced uncertainty quantification of the neutron multiplication factor. This work shows that a reduction in the nuclear data-induced uncertainty of the neutron multiplication factor is possible for all nuclide-reaction pairs investigated when prompt neutron decay constant sensitivity coefficients are utilized. This is important for new critical experiment design optimization studies of measurement configurations. This work provides a basis for more detailed sensitivity analysis and uncertainty quantification of nuclide, reaction, and energy-specific cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗