Search NASA⌕ Search

SEARCH · Search NASA

Results for “Session detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

THE VARIABILITY OF SAGITTARIUS A* AT 3 MILLIMETER

We have performed monitoring observations of the 3 mm flux density toward the Galactic center compact radio source Sagittarius A* (Sgr A*) with the Australia Telescope Compact Array since 2005 October. Careful calibrations of both elevation-dependent and time-dependent gains have enabled us to establish the variability behavior of Sgr A*. Sgr A* appeared to undergo a high and stable state in the 2006 June session, and a low and variable state in the 2006 August session. We report the results, with emphasis on two detected intraday variation events during its low states. One is on 2006 August 12 when Sgr A* exhibited a 33% fractional variation in about 2.5 hr. The other is on 2006 August 13 when two peaks separated by about 4 hr, with a maximum variation of 21% within 2 hr, were seen. The observed short timescale variations are discussed in light of two possible scenarios, i.e., the expanding plasmon model and the sub-Keplerian orbiting hot spot model. The fitting results indicate that for the adiabatically expanding plasmon model, the synchrotron cooling cannot be ignored, and a minimum mass-loss rate of 9.7 x 10{sup -10} M{sub sun} yr{sup -1} is obtained based on parameters derived for this modified expanding plasmon model. Simultaneous multiwavelength observation is crucial to our understanding of the physical origin of rapid radio variability in Sgr A*.

99 GENERAL AND MISCELLANEOUS↗

VerifyIO: Verifying Adherence to Parallel I/O Consistency Semantics

VerifyIO is a tool designed for verifying I/O consistency semantics in High-Performance Computing (HPC) applications. It addresses the challenges of ensuring correctness and portability across different I/O consistency models, such as POSIX, Commit, Session, and MPI-IO. By analyzing execution traces, detecting conflicts, and verifying synchronization adherence, VerifyIO provides actionable insights for both application developers and I/O library designers.

Wang, Chen [Lawrence Livermore National Laboratory↗

Securing your Site in Development and Beyond

Why wait until production deployment, or even staging and testing deployment to identify security vulnerabilities? Using tools like Burp Suite, you can find security vulnerabilities before they creep up on you. Prevent cross-site scripting attacks, and establish a firmer trust between your website and your client. Verify that Apache/Nginx have the correct SSL Ciphers set. We explore using these tools and more to validate proper Apache/Nginx configurations, and to be compliant with modern configuration standards as part of the development cycle. Your clients can use tools like https://securityheaders.io and https://ssllabs.com to get a graded report on your level of compliance with OWASP Secure Headers Project and SSLLabs recommendations. Likewise, you should always use the same sites to validate your configurations. Burp Suite will find common misconfigurations and will also perform more thorough security testing of your applications. In this session you will see examples of vulnerabilities that were detected early on, as well has how to integrate these practices into your daily workflow.

Akopov, Mikhail S.↗

Hungary 908 Event - Risk Based Graded Approach to ITM

This presentation, Risk-Based, Graded Approach to Insider Threat Mitigation: Human Measures, introduces a structured framework for managing insider threat risk using internationally recognized guidance from the International Atomic Energy Agency (IAEA) Nuclear Security Series No. 8-G (Rev. 1) and the Joint Statement on Mitigating Insider Threats (INFCIRC/908). The presentation emphasizes that effective insider threat mitigation (ITM) depends on both positional controls, which manage inherent risk based on access, authority, and knowledge, and human measures, which address residual risk reflected in behavior, motivation, and reliability. Using a risk-informed and graded approach, the presentation outlines methods for identifying and prioritizing high-risk positions, applying layered organizational controls, and integrating human reliability mechanisms such as the Behavior Observation Program (BOP), Fitness-for-Duty (FFD) evaluations, Employee Assistance Programs (EAP), and Nuclear Security Culture (NSC). The human-focused portion examines behavioral and organizational indicators of opportunity, vulnerability, motivation, and crisis, demonstrating how early detection, deterrence, and response can prevent insider events. The session concludes with a case review of the Millstone Nuclear Power Station incident involving engineer George Galatis. The case illustrates how weak leadership and a poor safety culture can create conditions for failure and how a comprehensive ITM framework could have altered the outcome. The objective of this presentation is to help practitioners apply a risk-based, graded philosophy to human factors and promote a culture of accountability, communication, and resilience within nuclear organizations.

99 - GENERAL AND MISCELLANEOUS↗

TH-B-BRC-00: How to Identify and Resolve Potential Clinical Errors Before They Impact Patients Treatment: Lessons Learned

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-01: How to Identify and Resolve Potential Clinical Errors

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-02: Troubleshooting Issues with Linear Accelerator

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

TH-B-BRC-03: Measurement and Calibration Discrepancy: Advanced Warning Guidance

Radiation treatment consists of a chain of events influenced by the quality of machine operation, beam data commissioning, machine calibration, patient specific data, simulation, treatment planning, imaging and treatment delivery. There is always a chance that the clinical medical physicist may make or fail to detect an error in one of the events that may impact on the patient’s treatment. In the clinical scenario, errors may be systematic and, without peer review, may have a low detectability because they are not part of routine QA procedures. During treatment, there might be errors on machine that needs attention. External reviews of some of the treatment delivery components by independent reviewers, like IROC, can detect errors, but may not be timely. The goal of this session is to help junior clinical physicists identify potential errors as well as the approach of quality assurance to perform a root cause analysis to find and eliminate an error and to continually monitor for errors. A compilation of potential errors will be presented by examples of the thought process required to spot the error and determine the root cause. Examples may include unusual machine operation, erratic electrometer reading, consistent lower electron output, variation in photon output, body parts inadvertently left in beam, unusual treatment plan, poor normalization, hot spots etc. Awareness of the possibility and detection of error in any link of the treatment process chain will help improve the safe and accurate delivery of radiation to patients. Four experts will discuss how to identify errors in four areas of clinical treatment. D. Followill, NIH grant CA 180803.

60 APPLIED LIFE SCIENCES↗

Outcomes of Iodine-125 Plaque Brachytherapy for Uveal Melanoma With Intraoperative Ultrasonography and Supplemental Transpupillary Thermotherapy

Purpose: To assess the impact on local tumor control of intraoperative ultrasonographic plaque visualization and selective application of transpupillary thermotherapy (TTT) in the treatment of posterior uveal melanoma with iodine-125 (I-125) episcleral plaque brachytherapy (EPB). Methods and Materials: Retrospective analysis of 526 patients treated with I-125 EPB for posterior uveal melanoma. Clinical features, dosimetric parameters, TTT treatments, and local tumor control outcomes were recorded. Statistical analysis was performed using Cox proportional hazards and Kaplan-Meier life table method. Results: The study included 270 men (51%) and 256 women (49%), with a median age of 63 years (mean, 62 years; range, 16-91 years). Median dose to the tumor apex was 94.4 Gy (mean, 97.8; range, 43.9-183.9) and to the tumor base was 257.9 Gy (mean, 275.6; range, 124.2-729.8). Plaque tilt >1 mm away from the sclera at plaque removal was detected in 142 cases (27%). Supplemental TTT was performed in 72 patients (13.7%). One or 2 TTT sessions were required in 71 TTT cases (98.6%). After a median follow-up of 45.9 months (mean, 53.4 months; range, 6-175 months), local tumor recurrence was detected in 19 patients (3.6%). Local tumor recurrence was associated with lower dose to the tumor base (P=.02). Conclusions: Ultrasound-guided plaque localization of I-125 EPB is associated with excellent local tumor control. Detection of plaque tilt by ultrasonography at plaque removal allows supplemental TTT to be used in patients at potentially higher risk for local recurrence while sparing the majority of patients who are at low risk. Most patients require only 1 or 2 TTT sessions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated Weed Control for Land Stewardship at Legacy Management's Rocky Flats Site in Colorado - 13086

Land stewardship is one of nine sustainability programs in the U.S. Department of Energy's Environmental Management System. Land stewardship includes maintaining and improving ecosystem health. At the Rocky Flats Site near Westminster, Colorado, land stewardship is an integral component of the Office of Legacy Management's post-closure monitoring and management at the site. Nearly 263 hectares (650 acres) were disturbed and re-vegetated during site cleanup and closure operations. Proactive management of revegetation areas is critical to the successful reestablishment of native grasslands, wetlands, and riparian communities. The undisturbed native plant communities that occur at the site also require active management to maintain the high-quality wetlands and other habitats that are home to numerous species of birds and other wildlife such as elk and deer, rare plant communities, and the federally listed threatened Preble's meadow jumping mouse. Over the past several decades, an increase of Noxious weeds has impacted much of Colorado's Front Range. As a result, weed control is a key component of the land stewardship program at Rocky Flats. Thirty-three species of state-listed Noxious weeds are known to occur in the Central and Peripheral Operable Units at Rocky Flats, along with another five species that are considered invasive at the site. Early detection and rapid response to control new invasive species is crucial to the program. An integrated weed control/vegetation management approach is key to maintaining healthy, sustainable plant communities that are able to resist Noxious weed invasions. Weed mapping, field surveys, and field-staff training sessions (to learn how to identify new potential problem species) are conducted to help detect and prevent new weed problems. The integrated approach at Rocky Flats includes administrative and cultural techniques (prevention), mechanical controls, biological controls, and chemical controls. Several species of biocontrol insects have been released to assist with control of different target weed species. Monitoring is conducted to evaluate the effectiveness of control efforts and to provide information for future control efforts. The effective implementation of this integrated approach has reduced the infestation levels of many species and has kept several newly discovered invasive species from spreading and becoming larger problems at the site. (authors)

54 ENVIRONMENTAL SCIENCES↗

INTERFEROMETRIC MONITORING OF GAMMA-RAY BRIGHT AGNs. I. THE RESULTS OF SINGLE-EPOCH MULTIFREQUENCY OBSERVATIONS

We present results of single-epoch very long baseline interferometry (VLBI) observations of gamma-ray bright active galactic nuclei (AGNs) using the Korean VLBI Network (KVN) at the 22, 43, 86, and 129 GHz bands, which are part of a KVN key science program, Interferometric Monitoring of Gamma-Ray Bright AGNs. We selected a total of 34 radio-loud AGNs of which 30 sources are gamma-ray bright AGNs with flux densities of >6 × 10{sup −10} ph cm{sup −2} s{sup −1}. Single-epoch multifrequency VLBI observations of the target sources were conducted during a 24 hr session on 2013 November 19 and 20. All observed sources were detected and imaged at all frequency bands, with or without a frequency phase transfer technique, which enabled the imaging of 12 faint sources at 129 GHz, except for one source. Many of the target sources are resolved on milliarcsecond scales, yielding a core-jet structure, with the VLBI core dominating the synchrotron emission on a milliarcsecond scale. CLEAN flux densities of the target sources are 0.43–28 Jy, 0.32–21 Jy, 0.18–11 Jy, and 0.35–8.0 Jy in the 22, 43, 86, and 129 GHz bands, respectively. Spectra of the target sources become steeper at higher frequency, with spectral index means of −0.40, −0.62, and −1.00 in the 22–43 GHz, 43–86 GHz and 86–129 GHz bands, respectively, implying that the target sources become optically thin at higher frequencies (e.g., 86–129 GHz).

79 ASTRONOMY AND ASTROPHYSICS↗

Cutting-Edge Operations Concepts: Intelligent Infrastructure, Cooperative Driving, Signal Control, and Curbside Management

The objective of this breakout session at the NREL Mobility workshop was to examine emerging traffic operations concepts built on key detection technology such as radars, lidars, and imaging recognition - and identify challenges and paths forward to integrate into our current roadway system. The key objective were to identify the opportunities for intelligent infrastructure to support near-term safety, equity, energy, and congestion mitigation goals, while supporting longer term connected-automated vehicle objectives. In the plenary session, Eric Raamot, from the USDOT Highly Automated Safety Systems Office challenged the participants to think broadly about the roll of standards and reference architecture to provide both an accelerated rollout of intelligent infrastructure, but also a repeatable and supportable framework upon which many infrastructure owners and operators (IOOs) could utilize for their implementation purposes.

ADVANCED PROPULSION SYSTEMS↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

IP Profiling via Service Cluster Membership Vectors

This study investigates the feasibility of establishing and maintaining a system of compact IP behavioral profiles as a robust means of computer anomaly definition and detection. These profiles are based upon the degree to which a system's (IP's) network traffic is distributed among stable characteristic clusters derived of the aggregate session traffic generated by each of the major network services. In short, an IP's profile represents its degree of membership in these derived service clusters. The goal is to quantify and rank behaviors that are outside of the statistical norm for the services in question, or present significant deviation from profile for individual client IPs. Herein, we establish stable clusters for accessible features of common session traffic, migrate these clusters over time, define IP behavior profiles with respect to these clusters, migrate individual IP profiles over time, and demonstrate the detection of IP behavioral changes in terms of deviation from profile.

99 GENERAL AND MISCELLANEOUS↗

Quasi real time in vivo dosimetry for VMAT

Purpose: Results about the feasibility of a method for quasi real timein vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images was adopted to verify off-axis reproducibility of fractionated plan delivery. Methods: An algorithm to reconstructin vivo the isocenter dose, D{sub iso}, for RapidArc treatments has been developed. 20 VMAT plans, optimized with two opposite arcs, for prostate, pancreas, and head treatments have been delivered by a Varian linac both to a conic PMMA phantom with elliptical section and to patients. The ratios R between reconstructed D{sub iso} and the planned doses were determined for phantom and patient irradiations adopting an acceptance criterion of ±5%. In total, 40 phantom checks and 400 patient checks were analyzed. Moreover, 3% and 3 mm criteria were adopted for portal image γ-analysis to assess patient irradiation reproducibility. Results: The average ratio R, between reconstructed and planned doses for the PMMA phantom irradiations was equal to 1.007 ± 0.024. When the IVD method was applied to the 20 patients, the average R ratio was equal to 1.003 ± 0.017 and 96% of the tests were within the acceptance criteria. The portal image γ-analysis supplied 88% of the tests within the pass rates γ{sub mean} ≤ 0.4 and P{sub γ<1} ≥ 98%. All the warnings were understood comparing the CT and the cone beam CT images and in one case a patient's setup error was detected and corrected for the successive fractions. Conclusions: This preliminary experience suggests that the method is able to detect dosimetric errors in quasi real time at the end of the therapy session. The authors intend to extend this procedure to other pathologies with the integration of in-room imaging verification by cone beam CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interferometric Monitoring of Gamma-Ray Bright AGNs: S5 0716+714

We present the results of very long baseline interferometry (VLBI) observations of gamma-ray bright blazar S5 0716+714 using the Korean VLBI Network (KVN) at the 22, 43, 86, and 129 GHz bands, as part of the Interferometric Monitoring of Gamma-ray Bright active galactic nuclei (iMOGABA) KVN key science program. Observations were conducted in 29 sessions from 2013 January 16 to 2016 March 1, with the source being detected and imaged at all available frequencies. In all epochs, the source was compact on the milliarcsecond scale, yielding a compact VLBI core dominating the synchrotron emission on these scales. Based on the multiwavelength data between 15 GHz (Owens Valley Radio Observatory) and 230 GHz (Submillimeter Array), we found that the source shows multiple prominent enhancements of the flux density at the centimeter (cm) and millimeter (mm) wavelengths, with mm enhancements leading cm enhancements by −16 ± 8 days. The turnover frequency was found to vary between 21 and 69 GHz during our observations. By assuming a synchrotron self-absorption model for the relativistic jet emission in S5 0716+714, we found the magnetic field strength in the mas emission region to be ≤5 mG during the observing period, yielding a weighted mean of 1.0 ± 0.6 mG for higher turnover frequencies (e.g., >45 GHz).

79 ASTRONOMY AND ASTROPHYSICS↗

Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer

Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm{sup 2}) and one higher b value (aHBV at 2000 s/mm{sup 2}). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm{sup 2}) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm{sup 2}) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. Results: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm{sup 2} sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). Conclusion: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Transmission Technologies –GETs and HPCs Session 3: HPCs and Building Actions Plans to Digital Assurance Risks

The third session of the Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program, held on November 11, 2025, centered on High Performance Conductors (HPCs) and the formulation of action plans to address digital assurance risks associated with Grid-Enhancing Technologies (GETs). This session convened experts from utilities, vendors, and government agencies to examine the technical, operational, and cybersecurity aspects of HPC deployment. Discussions highlighted the benefits of HPCs, such as their ability to rapidly increase transmission capacity using existing corridors, improve grid resilience, reduce system losses, and align with FERC Orders 2023 and 1920. Participants evaluated supply chain and digital assurance risks, including reliance on imported materials, limited domestic manufacturing capacity, workforce shortages, and traceability issues. The session also emphasized the importance of digital trust, integration-layer cybersecurity, and unified risk frameworks, introducing tools like intrusion detection systems, encryption, zero trust networking, and firmware integrity. Recaps of earlier workshops on Dynamic Line Ratings (DLRs), Advanced Power Flow Control (APFC), and Transmission Topology Optimization (TTO) underscored institutional barriers and integration challenges. Action plans were proposed to mitigate issues such as inconsistent cybersecurity practices, SBOM usage, supply chain visibility, operator trust, and misaligned incentives. Additionally, INL presented its supply chain risk management tools and Cyber-Informed Engineering (CIE) principles to support secure procurement and system design. The session concluded with a commitment to share key takeaways, incorporate cohort feedback into future policy development, and continue collaborative engagement through upcoming pilot activities. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗