Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shading control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

General-Purpose Software For Computer Graphics

NASA Device Independent Graphics Library (NASADIG) is general-purpose computer-graphics package for computer-based engineering and management applications which gives opportunity to translate data into effective graphical displays for presentation. Features include two- and three-dimensional plotting, spline and polynomial interpolation, control of blanking of areas, multiple log and/or linear axes, control of legends and text, control of thicknesses of curves, and multiple text fonts. Included are subroutines for definition of areas and axes of plots; setup and display of text; blanking of areas; setup of style, interpolation, and plotting of lines; control of patterns and of shading of colors; control of legends, blocks of text, and characters; initialization of devices; and setting of mixed alphabets. Written in FORTRAN 77.

Rogers, Joseph E.↗

Thermal heliotrope - A passive sun-tracker

Continuous sun tracking device consists of helical bimetallic coil and control mechanism. Coil produces torque and angular displacement with temperature change, and acts as device's driving element. Control mechanism, concentric shading mechanism containing bimetallic sensor coil, controls tracking rate and provides for reset cycle.

Byxbee, R. C.↗

Planetary cartography in the next decade (1984 - 1994)

The cartographic products required to support science and planetary exploration during the next 10 years were assessed. Only major map series or first order maps needed to characterize the surface physiography of a planet or satellite were considered. Included in these considerations are maps needed as bases for plotting geologic, geophysical, and atmospheric phenomena and for planning future planetary exploration. These products consist of three types of maps: controlled photomosaics, shaded relief maps, and topographic contour maps.

Source record↗

Possible breakup of dark terrain on Ganymede by large-scale shear faulting

The questions of relative motions of large segments of Ganymede's lithosphere and of the effect of any motions on grooved terrain formation are reexamined. Resolvable furrows in both hemispheres were mapped in great detail using Voyager 1 and 2 images and U.S. Geological Survey controlled shaded-relief quadrangle maps. Estimates of the Galileo Regio and Marius Regio poles of furrow concentricity indicate a considerable westward offset of the Galileo Regio pole, suggesting the possibility of about 500-km of left-lateral offset of the two areas. There is evidence that shear deformation was concentrated along a major structural lineament which follows a small circle and encloses Galileo Regio, and that a smaller amount of distributed shear occurred across an adjacent 500- to 1500-km-wide band. The results indicate that either widespread shear strain or the shear's driving mechanism may have had a long-term effect on patterns of deformation of Ganymede's lithosphere.

Murchie, Scott L.↗

PNC Financial Services - Net-Zero Energy Bank Branch

PNC has opened a zero-energy building that is 57% more efficient than ASHRAE 90.1-2004. Exterior features include shading to control glare from sunlight and photovoltaic solar panels to produce as much electricity as the building consumes annually.

bank↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Control algorithms for dynamic windows for residential buildings

This study analyzes the influence of control algorithms for dynamic windows on energy consumption, number of hours of retracted shades during daylight and shade operations. Five different control algorithms - heating/cooling, simple rules, perfect citizen, heat flow and predictive weather were developed and compared. The performance of a typical residential building was modeled with EnergyPlus. The program Widow was used to generate a Bi-Directional Distribution Function (BSDF) for two window configurations. The BSDF was exported to EnergyPlus using the IDF file format. The EMS feature in EnergyPlus was used to develop custom control algorithms. The calculations were made for four locations with diverse climate. The results showed that: (a) use of automated shading with proposed control algorithms can reduce the site energy in the range of 11.6-13.0%; in regard to source (primary) energy in the range of 20.1-21.6%, (b) the differences between algorithms in regard to energy savings are not high, (c) the differences between algorithms in regard to number of hours of retracted shades are visible, (e) the control algorithms have a strong influence on shade operation and oscillation of shade can occur, (d) additional energy consumption caused by motor, sensors and a small microprocessor in the analyzed case is very small.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

April Burn-in Testing Report for Genentech B35, South San Francisco Campus

Genentech and Webcor reserved a thirty-day “burn-in” period after completion of the commissioning phase to conduct a detailed evaluation of all systems in the new HTA B35 building prior to occupancy. During this period, LBNL evaluated the automated shading and dimmable indoor lighting control systems to determine whether the systems were working according to design intent. LBNL also evaluated lighting energy use and visual and thermal comfort in the perimeter zones. LBNL conducted the monitored evaluation in four perimeter zones on the 7th floor from March 25th to May 7th, 2015. The daylight and tuning control functions of the dimmable LED direct-indirect lighting control system were evaluated and then adjusted in collaboration with the electrical contractor (Redwood Electric) during the first three weeks of the evaluation. The lighting controls were then considered to be operating as expected after April 20th and a detailed evaluation of control performance and energy use was conducted thereafter. The automated shading system was assessed over a limited period (April 15-30) on both the 6th and 7th floors to determine whether the controls raised the shade when discomfort glare was imperceptible. After a few days of analysis, changes were made to the settings to admit more daylight by changing both the glare sensor threshold and by increasing the depth of direct sun ingress from 36” to 48” from the façade on all orientations except the east.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shade signals alter the expression of circadian clock genes in newly-formed bioenergy sorghum internodes

Stem internodes of bioenergy sorghum inbred R.07020 are longer at high plant density (shade) than at low plant density (control). Initially, the youngest newly-formed subapical stem internodes of shade-treated and control plants are comparable in length. However, full-length internodes of shade-treated plants are three times longer than the internodes of the control plants. To identify the early molecular events associated with internode elongation in response to shade, we analyzed the transcriptome of the newly-formed internodes of shade-treated and control plants sampled between 4 and 6 hr after the start of the light period (14 hr light/10 hr dark). Sorghum genes homologous to the Arabidopsis shade marker genes ATHB2 and PIL1 were not differentially expressed. The results indicate that shade signals promote internode elongation indirectly because sorghum internodes are not illuminated and grow while enclosed with leaf sheaths. Sorghum genes homologous to the Arabidopsis morning-phased circadian clock genes LHY, RVE, and LNK were downregulated and evening-phased genes such as TOC1, PRR5, and GI were upregulated in young internodes in response to shade. We hypothesize that a change in the function or patterns of expression of the circadian clock genes is the earliest molecular event associated with internode elongation in response to shade in bioenergy sorghum. Increased expression of CycD1, which promotes cell division, and decreased expression of cell wall-loosening and MBF1-like genes, which promote cell expansion, suggest that shade signals promote internode elongation in bioenergy sorghum in part through increasing cell number by delaying transition from cell division to cell expansion.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sun shield

A shading device which is capable of compactly storing a flexible shade on a biased, window shade type spring roller is disclosed. It is controlled to deliver the shade selectively to either its operative shading or compact storage orientation.

Frank, Arthur M.↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of a mechanically ventilated double-skin facade with venetian sun-shading device: A full-scale investigation in controlled environment

The aim of this article is to present results of an experimental campaign performed on a full-scale facility provided with a double-skin facade. The behaviour of this architectural concept is tested under controlled climatic conditions. A summer case is scrutinised under different configurations: variation of the airflow through the double-skin facade and different angle of the solar shading device. This paper describes the experimental conditions, as well the test facility and the tested facade element. The results show the temperatures of the test cell and the facade and how they depend on the climatic conditions and the sun-shading device blade angles. One objective of this research was to measure and provide extensive data set detailing air and surface temperatures on the double-skin facade, together with airflow rates and air velocities. The experiments are fully described so that the results can be used for the validation of numerical models dealing with ventilated double-skin facades with venetian sun-shading device. (author)

14 SOLAR ENERGY↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Initial Feasibility Assessment of Agrivoltaics in Jackson County, IL

Consistent with concerns raised in other rural communities, the agricultural community in Jackson County, IL is reluctant to install ground based photovoltaic (PV) systems on prime agricultural land. Agrivoltaic solutions have the potential to mitigate community concerns of conversion of farmland to solar energy by allowing for both energy production and farming practices to occur on the same land area. To assess the potential for agrivoltaics in Jackson County, IL, the Jackson County Coalition requested technical assistance to perform an initial technoeconomic assessment, resource assessment, and feasibility assessment based on the unique agricultural context present in the area. In this paper, the National Renewable Energy Laboratory (NREL) interviewed five Jackson County experts for five key crops (vineyards, strawberries, pumpkins, apple and pear orchards, and hemp) to examine potential for agrivoltaics integration and identify key barriers that could hamper development. NREL performed technoeconomic analysis for different agrivoltaic system designs to determine the economic constraints and opportunities of agrivoltaics development. Overall, there is no one path for agrivoltaics success in Jackson County. Pilot projects can assist in demonstrating agrivoltaic feasibility to stakeholders reluctant to be first adopters. Based on preliminary analyses, agrivoltaic integration with vineyards may prove most feasible as the per acre returns of grapes are comparable with the returns needed to offset higher solar development costs for agrivoltaic systems. In terms of technical specifications of solar, pumpkins and strawberries could be integrated into more traditional solar designs, but there are concerns with shading and pest control. There is no one size fits all solution, and many options may need exploring before a workable solution is found.

14 SOLAR ENERGY↗

A new edition of the Mars 1:5,000,000 map series

A new edition of the Mars 1:5,000,000 scale map series is in preparation. Two sheets will be made for each quadrangle. Sheet one will show shaded relief, contours, and nomenclature. Sheet 2 will be a full-color photomosaic prepared on the Mars digital image model (MDIM) base co-registered with the Mars low-resolution color database. The latter will have an abbreviated graticule (latitude/longitude ticks only) and no other line overprint. The four major databases used to assemble this series are now virtually complete. These are: (1) Viking-revised shaded relief maps at 1:5,000,000 scale; (2) contour maps at 1:2,000,000 scale; (3) the Mars digital image model; and (4) a color image mosaic of Mars. Together, these databases form the most complete planetwide cartographic definition of Mars that can be compiled with existing data. The new edition will supersede the published Mars 1:5,000,000 scale maps, including the original shaded relief and topographic maps made primarily with Mariner 9 data and the Viking-revised shaded relief and controlled photomosaic series. Publication of the new series will begin in late 1991 or early 1992, and it should be completed in two years.

Batson, R. M.↗