Investigations about iso-geometric analysis for self-shielding calculations with the subgroup method

The implementation of a self-shielding method for a neutron transport calculation code based on the iso-geometric analysis (IGA) method that can resolve the multi-group neutron transport equation for arbitrary spatial domain, is presented. The self-shielding model based on the subgroup theory is adopted because the subgroup method can be used to perform calculations for any arbitrary geometrical domain which is the main purpose of our IGA code. Some basic theory of the subgroup method is given. A self-shielding calculation based on the PWR fuel pin composed of MOX fuel is presented and compared with a Monte Carlo calculation. The result is that the combination of SN transport theory, IGA and the subgroup method gives correctly shielded cross sections. Validation of the combination of the IGA method and SN neutron transport for subgroup calculations in two steps are presented: the first step is to ascertain the correctness of the IGA solutions compared to a known analytical solution in diffusion theory; the second step is a validation of the IGA solutions compared to a reference calculation in SN transport theory. The relation between the settings for the IGA solver and the accuracy of the results are elucidated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MORSE Monte Carlo shielding calculations for the zirconium hydride reference reactor

Verification of DOT-SPACETRAN transport calculations of a lithium hydride and tungsten shield for a SNAP reactor was performed using the MORSE (Monte Carlo) code. Transport of both neutrons and gamma rays was considered. Importance sampling was utilized in the MORSE calculations. Several quantities internal to the shield, as well as dose at several points outside of the configuration, were in satisfactory agreement with the DOT calculations of the same.

Burgart, C. E.↗

MCNPX Cosmic Ray Shielding Calculations with the NORMAN Phantom Model

The United States is planning manned lunar and interplanetary missions in the coming years. Shielding from cosmic rays is a critical aspect of manned spaceflight. These ventures will present exposure issues involving the interplanetary Galactic Cosmic Ray (GCR) environment. GCRs are comprised primarily of protons (approx.84.5%) and alpha-particles (approx.14.7%), while the remainder is comprised of massive, highly energetic nuclei. The National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) has commissioned a joint study with Los Alamos National Laboratory (LANL) to investigate the interaction of the GCR environment with humans using high-fidelity, state-of-the-art computer simulations. The simulations involve shielding and dose calculations in order to assess radiation effects in various organs. The simulations are being conducted using high-resolution voxel-phantom models and the MCNPX[1] Monte Carlo radiation-transport code. Recent advances in MCNPX physics packages now enable simulated transport over 2200 types of ions of widely varying energies in large, intricate geometries. We report here initial results obtained using a GCR spectrum and a NORMAN[3] phantom.

James, Michael R.↗

Comparison of Analytical Shielding Calculations for NSLS-II Linac Lateral Wall with FLUKA Monte-Carlo Program

The bulk shielding for NSLS II accelerator enclosures has been designed to reduce the dose rates to less than 0.5 mrem/h at the occupied regions during normal operation. The lateral wall for Linac enclosure is designed to protect personnel from the transverse radiation. The current Linac lateral wall is composed of 1 m concrete, based on the analytical calculations using Swansons’ thick target approximation [1]. The dose rate calculations with current Linac lateral shielding (general area and penetrations) have been carried out by FLUKA. The FLUKA Monte Carlo results were compared with the analytical calculation [1]. The dose rates calculated by SHIELD11 [2] program for limited cases have also been included in this technical note.

36 MATERIALS SCIENCE↗

Comparison of the MCNP6 and FLUKA Codes in Shielding Calculation at ProNova Proton Therapy Facility

The Monte Carlo method is a powerful tool to simulate particle transport in materials, and can be effectively used to design radiation shielding. The purpose of this study is to compare the results from two Monte Carlo codes (MCNP6 and FLUKA ) in shielding design. The calculation was also compared with the measured results from the ProNova Superconducting 360 degrees (SC360) installation at the Knoxville Provision Center for Proton Therapy (PCPT) facility. The SC360 230 MeV continue wave (CW) proton beam is produced by an isochronous cyclotron, the Sumitomo P235. The maximum beam that is extracted into the beamline is 300 nA, which is of 60% of the full current generated in cyclotron. The SC360 facility has an energy selection system for adjusting the proton range, one fixed beam and one gantry room for rotating the beam around the stationary patient. At the entrance to each treatment room beamline, a thickness adjustable Beryllium degrader inserted in the beam path is used to achieve the desirable beam energy. When protons interact with beamline components, the secondary neutrons become the dominant source to determine the radiation shielding. In this study, the dose rate outside the lateral wall of the beamline vault was discussed. The calculations from two Monte Carlo codes were compared and they agreed very well. The dose rates measured by a Wendi-II Neutron Detector agreed within a factor of less than seven compared with the calculation results. The difference may be explained by a variety of factors such as the uncertainty in knowing the exact composition of shielding materials, geometry difference, and the measurement uncertainty due to instrumentation. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data

Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was used to describe the transmission curve for each of the 216 energy-material combinations. These three parameters, and hence the transmission curve, for any polyenergetic spectrum can then be obtained by superposition along the lines of Kharrati et al. [“Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities,” Med. Phys. 34, 1398–1404 (2007)]. A simple program, incorporating a graphical user interface, was developed to facilitate the superposition of monoenergetic data, the graphical and tabular display of broad photon beam transmission curves, and the calculation of material thickness required for a given transmission from these curves. Results: Polyenergetic broad photon beam transmission curves of this work, calculated from the superposition of monoenergetic data, are compared to corresponding results in the literature. A good agreement is observed with results in the literature obtained from Monte Carlo simulations for the photon spectra emitted from bare point sources of various radionuclides. Differences are observed with corresponding results in the literature for x-ray spectra at various tube potentials, mainly due to the different broad beam conditions or x-ray spectra assumed. Conclusions: The data of this work allow for the accurate calculation of structural shielding thickness, taking into account the spectral variation with shield thickness, and broad beam conditions, in a realistic geometry. The simplicity of calculations also obviates the need for the use of crude transmission data estimates such as the half and tenth value layer indices. Although this study was primarily designed for brachytherapy, results might also be useful for radiology and nuclear medicine facility design, provided broad beam conditions apply.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-569: Neutron Shielding Calculation Using Analytical and Multi-Monte Carlo Method for Proton Therapy Facility

Purpose: To evaluate the shielding wall design to protect patients, staff and member of the general public for secondary neutron using a simply analytic solution, multi-Monte Carlo code MCNPX, ANISN and FLUKA. Methods: An analytical and multi-Monte Carlo method were calculated for proton facility (Sumitomo Heavy Industry Ltd.) at Samsung Medical Center in Korea. The NCRP-144 analytical evaluation methods, which produced conservative estimates on the dose equivalent values for the shielding, were used for analytical evaluations. Then, the radiation transport was simulated with the multi-Monte Carlo code. The neutron dose at evaluation point is got by the value using the production of the simulation value and the neutron dose coefficient introduced in ICRP-74. Results: The evaluation points of accelerator control room and control room entrance are mainly influenced by the point of the proton beam loss. So the neutron dose equivalent of accelerator control room for evaluation point is 0.651, 1.530, 0.912, 0.943 mSv/yr and the entrance of cyclotron room is 0.465, 0.790, 0.522, 0.453 mSv/yr with calculation by the method of NCRP-144 formalism, ANISN, FLUKA and MCNP, respectively. The most of Result of MCNPX and FLUKA using the complicated geometry showed smaller values than Result of ANISN. Conclusion: The neutron shielding for a proton therapy facility has been evaluated by the analytic model and multi-Monte Carlo methods. We confirmed that the setting of shielding was located in well accessible area to people when the proton facility is operated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of angular quadrature on results of two-dimensional space power reactor shield calculations.

Study of the effect of angular quadrature on the results of two-dimensional transport calculations made to evaluate radiation environment in the vicinity of a shielded space power reactor. The application considered is for a manned space-station; crew shielding must be provided within a 25 deg cone angle. The asymmetric shield layout is evaluated using the two-dimensional transport code DOT. Within the shield, an S sub 6 angular quadrature yields satisfactory results. For regions where the ray effect may occur it is not apparent that an S sub 10 quadrature is adequate. Anomalies in results due to transport of particles in a void and necessary geometric approximations were observed.

Connolley, D. J.↗

SUBGR: A Program to Generate Subgroup Data for the Subgroup Resonance Self-Shielding Calculation

The Subgroup Data Generation (SUBGR) program generates subgroup data, including levels and weights from the resonance self-shielded cross section table as a function of background cross section. Depending on the nuclide and the energy range, these subgroup data can be generated by (a) narrow resonance approximation, (b) pointwise flux calculations for homogeneous media; and (c) pointwise flux calculations for heterogeneous lattice cells. The latter two options are performed by the AMPX module IRFFACTOR. These subgroup data are to be used in the Consortium for Advanced Simulation of Light Water Reactors (CASL) neutronic simulator MPACT, for which the primary resonance self-shielding method is the subgroup method.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Shielding Calculation for High Energy Radiation X-Ray by Software program

There are analytic methods for designing protective barriers however, they lack sufficient efficiency and considering the NCRP147(reports2007), designing mechanical protective barrier in order to protect the initial x-ray radiation and absorption of the ray quality of such radiation is different. In this study, computer software was designed to calculate the needed barrier with high accuracy. For proper determination of thickness of the protective barrier, relevant information about curves of radiation weakness, dose limit etc should be entered. The difference between the theoretical and calculated rates of this method is X{sup 2} = 10{sup -5} which indicates accuracy and high efficiency of this software.

61 RADIATION PROTECTION AND DOSIMETRY↗

NSLS-II beamline scattered gas bremsstrahlung radiation shielding calculation

National Synchrotron Light Source II (NSLS-II) is a new state-of-the-art 3rd generation synchrotron. The NSLS-II facility is shielded up to 3 GeV electron beam energy at 500 mA. When the gas bremsstrahlung (GB) from the storage ring is scattered by the beamline components in the first optical enclosure (FOE), the scattered radiation will pose additional radiation hazard (bypassing primary GB collimators and stops) and challenge the FOE shielding. The scattered GB radiation hazard can be mitigated by supplementary shielding or with an exclusion zone downstream of the FOE.

43 PARTICLE ACCELERATORS↗

The MAVRIC-Shift Sequence in SCALE for Radiation Transport and Shielding Calculations with Automated Variance Reduction and Parallel Computing

A new MAVRIC-Shift sequence has been implemented and tested within the SCALE Code System to provide parallel computing capabilities for radiation transport and shielding analysis with automated variance reduction. This new sequence provides the most widely used capabilities of the MAVRIC sequence and also features the highly scalable Shift Monte Carlo solver, thus enabling faster time-to-solution when run on multiple cores. This report provides a summary of the theory of variance reduction approaches in MAVRIC and the integration of Shift into the MAVRIC sequence of SCALE. Similarities and differences in methodologies between the traditional MAVRIC sequence and the new MAVRIC-Shift sequence are discussed. Validation cases are presented with models of radiation shielding experiments and verification is provided with a series of practical application cases of interest to the US Nuclear Regulatory Commission, the sponsors of this work, including spent nuclear fuel transportation and storage systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background simulations and shielding calculations

Key improvements in the sensitivity of the underground particle astrophysics experiments can only be achieved if the radiation causing background events in detectors is well understood and proper measures are taken to suppress it. The background radiation arising from radioactivity and cosmic-ray muons is discussed here together with the methods of its suppression. Different shielding designs are considered to attenuate gamma-rays and neutrons coming from radioactivity in rock and lab walls. Purity of materials used in detector construction is analysed and the background event rates due to the presence of radioactive isotopes in detector components are discussed. Event rates in detectors caused by muon-induced neutrons with and without active veto systems are presented leading to the requirements for the depth of an underground laboratory and the efficiency of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam line shielding calculations for an Electron Accelerator Mo-99 production facility

The purpose of this study is to evaluate the photon and neutron fields in and around the latest beam line design for the Mo-99 production facility. The radiation dose to the beam line components (quadrupoles, dipoles, beam stops and the linear accelerator) are calculated in the present report. The beam line design assumes placement of two cameras: infra red (IR) and optical transition radiation (OTR) for continuous monitoring of the beam spot on target during irradiation. The cameras will be placed off the beam axis offset in vertical direction. We explored typical shielding arrangements for the cameras and report the resulting neutron and photon dose fields.

43 PARTICLE ACCELERATORS↗

Radiation Shielding Calculations for E1039 Seaquest Experiment

The E1039 Seaquest experiment is designed to study results of interactions of the 120 GeV proton beam, delivered from Main Injector, with transversely polarized hydrogen target in the form of liquid ammonia (NH3). The E1039 experiment is re-using the Neutrino-Muon beamline, spectrometer magnet (FMAG), KMAG, and other hardware from its predecessor—the E906 experiment. Only the central 2 Tesla magnetic field was modeled in the FMAG magnet which also serves also as a beam absorber. Various updates were performed to the beamline and shielding around the magnet compared to E906 including relocation of the target 3 meters upstream of the front face of FMAG. Further, several updates were performed on the MARS15 model developed previously [1-2] in order to better describe important surrounding areas, in particular the counting room. Several optimization iterations of the shielding design were done and only the final configuration is discussed in this document. The model includes realistically stacked concrete shielding blocks along with airgaps required for piping, ductwork and detectors. The main features of the shielding update can be summarized as follows: (i) additional concrete shielding was added above the magnet to degrade the energy of neutrons to thermal levels; (ii) a new target alcove with the target cryostat inside. These updates are intended to provide increased protection for both normal operation and accident conditions upstream of the target. The Figures 1 thru 3 below describe the MARS15 model in detail as well as an excerpt of the 3D CAD model design which was used to build the MARS15 model.

43 PARTICLE ACCELERATORS↗

Shielding Calculations for NSLS-II Beamlines.

Brookhaven National Laboratory is in the process of designing a new Electron Synchrotron for scientific research using synchrotron radiation. This facility, called the 'National Synchrotron Light Source II' (NSLS-II), will provide x-ray radiation of ultra-high brightness and exceptional spatial and energy resolution. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the facility. The project scope includes the design, construction, installation, and commissioning of the following accelerators: a 200 MeV linac, a booster accelerator operating from 200 MeV to 3.0 GeV, the storage ring which stores 500 mA current of electrons at an energy of 3.0 GeV and 56 beamlines for experiments. It is planned to operate the facility primarily in a top-off mode, thereby maintaining the maximum variation in stored beam current to < 1%. Because of the very demanding requirements for beam emittance and synchrotron radiation brilliance, the beam life-time is expected to be quite low, on the order of 2 hours. Each of the 56 beamlines will be unique in terms of the source properties and configuration. The shielding designs for five representative beamlines are discussed in this paper.

43 PARTICLE ACCELERATORS↗