Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shutter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Nonergodic dynamics in disorder-free potentials

Highlights: • Dynamics in tilted lattices with harmonic confinement is reviewed. • Both spinless and spinful fermions are analyzed. • Local effective tilt is the relevant parameter for nonergodicity. • Neel or domain wall initial states are studied. • Domains with similar spin orientation act as transport and communication barriers. We review the dynamics of interacting particles in disorder-free potentials concentrating on a combination of a harmonic binding with a constant tilt. We show that a simple picture of an effective local tilt describes a variety of cases. Our examples include spinless fermions (as modeled by Heisenberg spin chain in a magnetic field), spinful fermions as well as bosons that enjoy a larger local on-site Hilbert space. We also discuss the domain-wall dynamics that reveals nonergodic features even for a relatively weak tilt as suggested by Doggen et al. (2020). By adding a harmonic potential on top of the static field we confirm that the surprising regular dynamics is not entirely due to Hilbert space shuttering. It seems better explained by the inhibited transport within the domains of identically oriented spins. Once the spin-1/2 restrictions are lifted as, e.g., for bosons, the dynamics involve stronger entanglement generation. Again for domain wall melting, the effect of the harmonic potential is shown to lead mainly to an effective local tilt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Visible-Light Photoinitiation of (Meth)acrylate Polymerization with Autonomous Post-Conversion

Conversion plateaus rapidly in radical photopolymerizations (RPPs) following discontinuation of irradiation due to rapid termination of reactive radicals, which restricts the wider use of RPPs in applications that involve nonuniform light access including those with attenuated light transmission or irregular surfaces. Based on our recent report of a radical dark-curing photoinitiator (DCPI) that continues polymerization beyond the cessation of irradiation by enabling latent redox initiation with photo-released amine in the presence of a suitable oxidant, we developed a new DCPI with an absorption spectrum that extends well into the visible range. Our design process involved a series of computational investigations of candidate molecules, including a systematic study of substituents and their position-dependent effects on absorption characteristics, electronic transitions, and the photochemical mechanism and its associated energetics. Our quantum chemical computations identified the target compound 5,7-dimethoxy-6-bromo-3-aroylcoumarin-DMPT/BPh4 and predicted that it would facilitate the dark-curing mechanism by concurrent photo-radical generation and photo-induced release of an efficient redox reductant under visible irradiation. This reductant-tethered chromophore was then synthesized and optically characterized with UV–vis spectroscopy that revealed its strong visible-light absorption with a molar absorptivity of 5710 M–1 cm–1 at 405 nm and 50 M–1 cm–1 at 455 nm. We then demonstrated extensive dark-curing of >35% additional conversion over 25 min following brief activation of the shelf-stable one-part system by irradiation with a 455 nm LED that was ceased at 20% conversion. In contrast, shuttering irradiation of the control formulation at that same point resulted in immediate cessation of conversion, which plateaued at 20%. We determined a remarkable initiator efficiency of 2.82 that results from the additional redox-generated radicals with a 77% photo-reductant generation quantum yield. The combination of superior photo- and dark-curing efficiencies of this new visible DCPI is expected to open new application opportunities in RPP, especially those involving resins that are highly light attenuating, surfaces that possess irregular features that produce uneven irradiance, and production lines where continued dark-curing downstream of the light activation step enhances line efficiencies.

absorption spectrum↗

Electrochromic Properties of Perovskite NdNiO 3 Thin Films for Smart Windows

Semiconductors with electrically tunable band gaps are of great interest in controlling transparency to electromagnetic radiation. Thin films of perovskite nickelate NdNiO 3 (NNO), a class of correlated oxides, were deposited on single-crystal (LaAlO 3 (LAO)) and polycrystalline (fluorine-doped tin oxide-coated glass (FTO)) substrates by magnetron sputtering, chemical solution deposition (CSD), and atomic layer deposition (ALD). Their electrochromic behaviors were investigated using a three-electrode setup in basic (KOH solution, pH = 12) electrolyte. During bleaching/coloration process, the proton intercalation/deintercalation and simultaneous electron compensation in the NNO lattice under electrical bias led to crossover of the material between the pristine-conducting phase (Ni 3+ ) and the strongly correlated insulating phase (Ni 2+ ), which serves as the working principle for electrochromic (tunable opacity in the visible range) behavior. Cyclic voltammetry (CV) scans demonstrate that NNO films are electrochemically stable in basic solutions for all three film deposition methods explored here. CV scans at varying rates enabled the extraction of diffusion coefficient of protons in thin film NNO, which is similar to 10 –7 cm 2 s –1 among all films studied. Large light transmittance modulation by bleaching and coloration was observed on films grown on both LAO and FTO substrates, suggesting its potential as an electrochromic material candidate for smart windows and optical shutter applications. Here, porous NNO films obtained by chemical solution deposition tend to demonstrate stronger electrochromic activity than dense films grown by sputtering or ALD.

36 MATERIALS SCIENCE↗

Stable Rate of Slip Along the Karakax Section of the Altyn Tagh Fault from Observation of Interglacial and Postglacial Offset Morphology and Surface Dating

Digital elevation maps obtained using TanDEM-X and Pleiades data combined with newly obtained surface age estimates using cosmogenic radionuclide (CRN) and optically simulated luminescence (OSL) methods are used to quantify the slip rate along the western section of the Altyn Tagh Fault in southern Xinjiang. The reconstruction of the conical shape of massive alluvial fans inferred to be from the Eemian (115±7 ka) from CRN dating shows consistent left-lateral offsets of 300±20 m, yielding a slip rate of 2.6±0.3 mm/year. Successive episodes of incision have left cut terraces inset in wide canyons, 10–25 m below the fans' surface. The incision was followed by the deposition of a broad terrace of early Holocene age, which is reincised by modern stream channels. Near the village of Shanxili, a 200 m wide valley is partially dammed by a shutter ridge displaced by the fault. A fill terrace deposited upstream from the ridge has an OSL age of 8.8±0.6 ka. The 23±2 m offset of the riser incising the terrace indicates a minimum postdepositional movement on the fault, yielding a Holocene rate of 2.6±0.5 mm/year, consistent with the 115-ka average slip rate. Furthermore, scarp degradation analysis using mass diffusion reveals a nonlinear relationship between fault displacement and degradation coefficient along the progressively exposed fault scarp, a pattern suggesting either seismic clustering or variable diffusion rate since the Eemian. Together with the Gozha Co-Longmu Co fault to the south, the Karakax section of the Altyn Tagh Fault contributes to the eastward movement of the western corner of Tibet.

58 GEOSCIENCES↗

A laser parameter study on enhancing proton generation from microtube foil targets

Abstract The interaction of an intense laser with a solid foil target can drive $$\sim$$ ∼ TV/m electric fields, accelerating ions to MeV energies. In this study, we experimentally observe that structured targets can dramatically enhance proton acceleration in the target normal sheath acceleration regime. At the Texas Petawatt Laser facility, we compared proton acceleration from a $$1\, {\upmu }\hbox {m}$$ 1 μ m flat Ag foil, to a fixed microtube structure 3D printed on the front side of the same foil type. A pulse length (140–450 fs) and intensity ((4–10) $$\times 10^{20}$$ × 10 20 W/cm $$^2$$ 2 ) study found an optimum laser configuration (140 fs, 4 $$\times 10^{20}$$ × 10 20 W/cm $$^2$$ 2 ), in which microtube targets increase the proton cutoff energy by 50% and the yield of highly energetic protons ( $$>10$$ > 10 MeV) by a factor of 8 $$\times$$ × . When the laser intensity reaches $$10^{21}$$ 10 21 W/cm $$^2$$ 2 , the prepulse shutters the microtubes with an overcritical plasma, damping their performance. 2D particle-in-cell simulations are performed, with and without the preplasma profile imported, to better understand the coupling of laser energy to the microtube targets. The simulations are in qualitative agreement with the experimental results, and show that the prepulse is necessary to account for when the laser intensity is sufficiently high.

43 PARTICLE ACCELERATORS↗

Carrier recombination dynamics and temperature dependent optical properties of InAs–GaSb heterostructures

Heterostructures with two dissimilar materials could offer unprecedented properties if one can carefully synthesize these heterostructures with atomically smooth interfaces and reduced number of recombination centers. InAs/GaSb-based heterostructures have technological importance for long wavelength infrared photodetectors if one can synthesize these materials with high-optical quality and high-carrier lifetime. In this work, the InAs/GaSb heterostructures with a different number of heterointerfaces and growth conditions were grown by solid source molecular beam epitaxy using valved cracker sources for both arsenic and antimony. Precise control of growth parameters and shutter sequences enabled abrupt InAs/GaSb heterointerfaces, as supported by a high-resolution transmission electron microscopic study. The temperature and power-dependent optical properties by photoluminescence (PL) spectroscopic analysis of InAs/GaSb heterostructures with 4 and 28 heterointerfaces displayed donor to the acceptor and the exciton bound to complex defects (V Ga Ga Sb ) 0 . Since the optical transition in PL measurements serves to determine the quality of the material, and the observed excitonic transitions from these InAs/GaSb heterostructures is an indication of high-quality materials. The high-carrier lifetimes of 139 ns to 185 ns from InAs/GaSb heterostructures were measured using microwave photoconductivity decay (μ-PCD) technique at room temperature. The observed increase in carrier lifetime is due to the decreasing number of Ga-related carrier recombination centers or defect complexes. This is further supported by the PL spectroscopic study. In addition, the carrier lifetime with different injection levels is supported by Shockley–Read–Hall recombination. We report these InAs/GaSb heterostructures with high-optical quality and high-carrier lifetimes would offer a path for the development of high-performance infrared photodetectors.

36 MATERIALS SCIENCE↗

An accurate measurement of the spectral resolution of the JWST Near Infrared Spectrograph

The spectral resolution (R ≡ λ/Δλ) of spectroscopic data is crucial information for accurate kinematic measurements. In this letter we present a robust measurement of the spectral resolution of the JWST Near Infrared Spectrograph (NIRSpec) in fixed slit (FS) and integral field spectroscopy (IFS) modes. Due to the similarity of the utilized slit dimension in the FS mode to that of the shutters in the multi-object spectroscopy (MOS) mode, our resolution measurements in the FS mode can also be used for the MOS mode in principle. We modeled H and He lines of the planetary nebula SMP LMC 58 using a Gaussian line spread function (LSF) to estimate the wavelength-dependent resolution for multiple disperser and filter combinations. We corrected for the intrinsic width of the planetary nebula’s H and He lines due to its expansion velocity by measuring it from a higher-resolution X-shooter spectrum. We find that NIRSpec’s in-flight spectral resolutions exceed the pre-launch estimates provided in the JWST User Documentation by 11–53% in the FS mode and by 1–24% in the IFS mode across the covered wavelengths. We recover the expected trend that the resolution increases with the wavelength within a configuration. The robust and accurate LSFs presented in this letter will enable high-accuracy kinematic measurements using NIRSpec for applications in cosmology and galaxy evolution.

methods: data analysis↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗

Spectroscopic investigation of early light emission from anode-initiated surface flashover in vacuum

Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Improving luminescence response in ZnGeN 2 /GaN superlattices: defect reduction through composition control

Abstract Color-mixed (cm) light-emitting diodes (LEDs) are theoretically the most efficient white light emitters, projected to improve white light luminous efficacy by 34% compared to incumbent phosphor converted LEDs. Since white light technology is pervasive and essential, small improvements in LED technology can result in energy savings. However, cm-LEDs are not yet realized due to poor efficacy in green and amber emitting materials, a spectral region colloquially referred to as the Green Gap. ZnGeN 2 is nearly isostructural and closely lattice-matched to GaN and can be heteroepitaxially integrated with existing GaN devices; ZnGeN 2 /GaN hybrid structures are theorized to emit green (~530 nn) light with a spontaneous emission rate 4.6–4.9 times higher than traditional InGaN LEDs when incorporated into III-N LED structures. In this report we demonstrate the molecular beam epitaxy (MBE) growth of GaN and ZnGeN 2 superlattices, an important step towards realizing multiple quantum well structures required for efficient LEDs. Elemental analysis, including atom probe tomography, shows that Ga and Ge are observed in both ZnGeN 2 and GaN layers, degrading the structural uniformity. The lack of elemental abruptness also leads to increased defect luminescence and reabsorption of band edge luminescence. The source of unintentional Ga distributed throughout the ZnGeN 2 layers was identified as excess flux escaping from around the closed MBE shutter. The source of unintentional Ge, which tended to incorporate as a single delta-doped layer in GaN, was identified as Ge riding along the cyclical metal-rich Ga adlayer used for high quality GaN, incorporating during subsequent nitrogen-rich growth step. Modifying the growth strategy results in improved structural quality, elemental abruptness, and luminescence response. This realization of structurally and elementally abrupt interfaces demonstrates the potential of heteroepitaxially integrated binary and ternary nitrides for energy-relevant devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Strobed imaging as a method for the determination and diagnosis of local seeing

ABSTRACT The image quality budget of many telescopes can have substantial contributions from local seeing, both ‘mirror’ and ‘dome’, which arise from turbulence and temperature variations that are difficult to quantify, measure directly, and ameliorate. We describe a method to determine the ‘local’ seeing degradation due to wavefront perturbations within the final few metres of the optical path from celestial sources to the focal plane of a ground-based telescope, using the primary instrument and along the same path taken by light from celestial sources. The concept involves placing strobed emitters along the light path to produce images on the main focal plane that ‘freeze’ different realizations of index perturbations. This method has the advantage of measuring directly the image motion and scintillation imparted by the dynamic spatial and temporal structure of local perturbations in the index of refraction along the light path, with a clean separation from seeing induced in the atmosphere above the dome. The strobed-source approach allows for rapid image motion and scintillation to be measured directly on the focal plane, even for large-aperture telescopes with wide-field instruments and slow shutters, such as that being constructed for the Rubin Observatory. A conceptual design is presented that uses the ‘guider’ CCDs in the Rubin telescope focal plane to make local-seeing measurements on demand, perhaps even during science exposures.

79 ASTRONOMY AND ASTROPHYSICS↗