At least 37 records · Page 2

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Compression in the NEXT-100 Data Acquisition System

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

A novel method to reconstruct the energy of hadronic showersin the CMS High Granularity Calorimeter (HGCAL) is presented. TheHGCAL is a sampling calorimeter with very fine transverse andlongitudinal granularity. The active media are silicon sensors andscintillator tiles readout by SiPMs and the absorbers are acombination of lead and Cu/CuW in the electromagnetic section, andsteel in the hadronic section. The shower reconstruction method isbased on graph neural networks and it makes use of a dynamicreduction network architecture. It is shown that the algorithm isable to capture and mitigate the main effects that normally hinderthe reconstruction of hadronic showers using classicalreconstruction methods, by compensating for fluctuations in themultiplicity, energy, and spatial distributions of the shower'sconstituents. The performance of the algorithm is evaluated usingtest beam data collected in 2018 prototype of the CMS HGCALaccompanied by a section of the CALICE AHCAL prototype. Thecapability of the method to mitigate the impact of energy leakagefrom the calorimeter is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

Advanced Electronics for the SONTRAC Neutron Spectrometer

Solar neutrons are the tell-tale of highly energetic processes (e.g. solar flares) at the Sun in which particle acceleration is taking place over a broad range in energy. Unlike charged radiation, neutrons escape unscathed from the ambient magnetic fields, providing a view of particle acceleration unhindered by the effects of transport. High-energy neutrons are challenging to measure with the traditional double scatter technique based on time-of-flight (ToF). This technique is limited by the finite flight path and active scintillator sizes required by small satellite platforms. The new SOlar Neutron TRACking (SONTRAC) concept, based on scintillating-fiber bundles, will provide high resolution imaging of fast neutrons at energies where the bulk of solar and magnetospheric neutrons resides. Recent development of the new SONTRAC instrument concept's advanced electronics and processing algorithms are presented.

SiPM readout↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large scale SiPM testing for the Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The extruded plastic scintillators will be embedded with wavelength shifting (WLS) fibres to absorb scintillating photons and propgate the re-emitted photons to the silicon-photomultipliers for the electronic signals. The CMV detector will require 760 extruded plastic scintillators to shield the mini-ICAL detector, and will require 3040 SiPMs for the readout. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99\% and fake veto rate less than 10$^{-5}$. Hence, every SiPM used in the detector needs to be characterised to satisfy the design goal of the CMV. For this, a large-scale testing system was developed, using an LED driver, to measure the gain and noise rate of each SiPM, and thus determine it's breakdown voltage ($V_{br}$) and optimum operating overvoltage ($V_{ov}$).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗