Pulsed Laser Single-Event Effects in Highly Scaled CMOS Technologies in the Presence of Dense Metal Coverage.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Electronic components used in high energy physics experiments are subjected to a radiation background composed of high energy hadrons, mesons and photons. These particles can induce permanent and transient effects that affect the normal device operation. Ionizing dose and displacement damage can cause chronic damage which disable the device permanently. Transient effects or single event effects are in general recoverable with time intervals that depend on the nature of the failure. The magnitude of these effects is technology dependent with feature size being one of the key parameters. Analog to digital converters are components that are frequently used in detector front end electronics, generally placed as close as possible to the sensing elements to maximize signal fidelity. We report on radiation effects tests conducted on 17 commercially available analog to digital converters and extensive single event effect measurements on specific twelve and fourteen bit ADCs that presented high tolerance to ionizing dose. We discuss mitigation strategies for single event effects (SEE) for their use in the large hadron collider environment.
The LBNL 88-Inch Cyclotron offers broad-spectrum neutrons for single event effects testing. We discuss results from this beamline for neutron soft upsets in Xilinx Virtex-4 and -5 field-programmable-gate-array (FPGA) devices.
We report an experimental study of the transients generated by pulsed x-rays, heavy ions, and different laser wavelengths in a Si p-i-n photodiode. We compare the charge collected by all of the excitation methods to determine the equivalent LET for pulsed x-rays relative to heavy ions. Our comparisons show that pulsed x-rays from synchrotron sources can generate a large range of equivalent LET and generate transients similar to those excited by laser pulses and heavy ion strikes. We also look at how the pulse width of the transients changes for the different excitation methods. We show that the charge collected with pulsed x-rays is greater than expected as the x-ray photon energy increases. Combined with their capability of focusing to small spot sizes and of penetrating metallization, pulsed x-rays are a promising new tool for high resolution screening of SEE susceptibility
The ion photon emission microscope (IPEM), a new radiation effects microscope for the imaging of single event effects from penetrating radiation, is being developed at Sandia National Laboratories and implemented on the 88' cyclotron at Lawrence Berkeley National Laboratories. The microscope is designed to permit the direct correlation between the locations of high-energy heavy-ion strikes and single event effects in microelectronic devices. The development of this microscope has required the production of a robust optical system that is compatible with the ion beam lines, design and assembly of a fast single photon sensitive measurement system to provide the necessary coincidence, and the development and testing of many scintillating films. A wide range of scintillating material for application to the ion photon emission microscope has been tested with few meeting the stringent radiation hardness, intensity, and photon lifetime requirements. The initial results of these luminescence studies and the current operation of the ion photon emission microscope will be presented. Finally, the planned development for future microscopes and ion luminescence testing chambers will be discussed.
Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).
Integration-technology feature shrink increases computing-system susceptibility to single-event effects (SEE). While modeling SEE faults will be critical, an integrated processor’s scope makes physically correct modeling computationally intractable. Without useful models, presilicon evaluation of fault-tolerance approaches becomes impossible. To incorporate accurate transistor-level effects at a system scope, we present a multiscale simulation framework. Charge collection at the 1) device level determines 2) circuit-level transient duration and state-upset likelihood. Circuit effects, in turn, impact 3) register-transfer-level architecture-state corruption visible at 4) the system level. Furthermore, the physically accurate effects of SEEs in large-scale systems, executed on a high-performance computing (HPC) simulator, could be used to drive cross-layer radiation hardening by design. We demonstrate the capabilities of this model with two case studies. First, we determine a D flip-flop’s sensitivity at the transistor level on 14-nm FinFet technology, validating the model against published cross sections. Second, we track and estimate faults in a microprocessor without interlocked pipelined stages (MIPS) processor for Adams 90% worst case environment in an isotropic space environment.
A variety of fault emulation systems have been created to study the effect of single-event effects (SEEs) in static random access memory (SRAM) based field-programmable gate arrays (FPGAs). These systems are useful for augmenting radiation-hardness assurance (RHA) methodologies for verifying the effectiveness for mitigation techniques; understanding error signatures and failure modes in FPGAs; and failure rate estimation. For radiation effects researchers, it is important that these systems properly emulate how SEEs manifest in FPGAs. If the fault emulation systems does not mimic the radiation environment, the system will generate erroneous data and incorrect predictions of behavior of the FPGA in a radiation environment. Validation determines whether the emulated faults are reasonable analogs to the radiation-induced faults. In this study we present methods for validating fault emulation systems and provide several examples of validated FPGA fault emulation systems.
The Inaugural Meeting on the Opportunities at the Single Event Effects—Muon Spectroscopy (SEEMS) facility was held June 11–12, 2019, at Oak Ridge National Laboratory (ORNL). Capabilities of the SEEMS facility concept were reviewed, with emphasis on particle beams for single event effects (SEE) testing of electronic devices (integrated circuits) and systems—a topic of growing interest and concern in aerospace avionics, satellites, supercomputing, autonomous cars, unmanned aerial vehicles and more. Participants from these industries and their regulators attended. A clear consensus on the growing and urgent need for SEE test capabilities like those offered by SEEMS was expressed. Subsequent to the meeting, letters of support for SEEMS were sent by The Boeing Company and Honeywell to the ORNL Laboratory Director, Thomas Zacharia.
Commercially available microprocessors could be useful to the space community for noncritical computations. There are many possible components that are smaller, lower-power, and less expensive than traditional radiation-hardened microprocessors. Many commercial microprocessors have issues with single-event effects (SEEs), such as single-event upsets (SEUs) and single-event transients (SETs), that can cause the microprocessor to calculate an incorrect result or crash. In this paper we present the Trikaya technique for masking SEUs and SETs through software mitigation techniques. Furthermore, test results show that this technique can be very effective at masking errors, making it possible to fly these microprocessors for a variety of missions.
Records of bit flips in the Cray-1 computer installed at Los Alamos in 1976 lead to an upset rate in the Cray-1 's bipolar SRAMs that correlates with the SEUs being induced by the atmospheric neutrons. In 1976 the Cray Research Company delivered its first supercomputer, the Cray-1, installing it at Los Alamos National Laboratory. Los Alamos had competed with the Lawrence Livermore National Laboratory for the Cray-1 and won, reaching an agreement with Seymour Cray to install the machine for a period of six months for free, after which they could decide whether to buy, lease or return it. As a result, Los Alamos personnel kept track of the computer reliability and performance and so we know that during those six months of operation, 152 memory parity errors were recorded. The computer memory consisted of approximately 70,000 1Kx1 bipolar ECL static RAMs, the Fairchild 10415. What the Los Alamos engineers didn't know is that those bit flips were the result of single event upsets (SEUs) caused by the atmospheric neutrons. Thus, these 152 bit flips were the first recorded SEUs on the earth, and were observed 2 years before the SEUs in the Intel DRAMs that had been found by May and Woods in 1978. The upsets in the DRAMs were shown to have been caused by alpha particles from the chip packaging material. In this paper we will demonstrate that the Cray-1 bit flips, which were found through the use of parity bits in the Cray-1, were likely due to atmospheric neutrons. This paper will follow the same approach as that of the very first paper to demonstrate single event effects, which occurred in satellite flip-flop circuits in 1975. The main difference is that in the four events that occurred over the course of 17 satellite years of operation were shown to be due to single event effects just a few years after those satellite anomalies were recorded. In the case of the Cray-1 bit flips, there has been a delay of more than 30 years between the occurrence of the bit flips and the identification of their cause as SEUs induced by the atmospheric neutrons.