Automatic compensation circuit for slow-sweep control of a stroboscopic oscillograph
Operating principle and functional automatic circuit for stroboscopic oscillograph control
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Operating principle and functional automatic circuit for stroboscopic oscillograph control
A method and apparatus is disclosed for producing large particles of material from gas, or gases, containing the material (e.g., silicon from silane) in a free-space reactor comprised of a tube (20) and controlled furnace (25). A hot gas is introduced in the center of the reactant gas through a nozzle (23) to heat a quantity of the reactant gas, or gases, to produce a controlled concentration of seed particles (24) which are entrained in the flow of reactant gas, or gases. The temperature profile (FIG. 4) of the furnace is controlled for such a slow, controlled rate of reaction that virtually all of the material released condenses on seed particles and new particles are not nucleated in the furnace. A separate reactor comprised of a tube (33) and furnace (30) may be used to form a seed aerosol which, after passing through a cooling section (34) is introduced in the main reactor tube (34) which includes a mixer (36) to mix the seed aerosol in a controlled concentration with the reactant gas or gases.
We report our experience on migrating STARs Online Services (Run Control System, Data Acquisition System, Slow Control System and Subsystem Monitoring) from direct read/write database accesses to a modern non-blocking message-oriented infrastructure. Based on the Advanced Messaging Queuing Protocol (AMQP) and standards, this novel approach does not specify the message data structure, allowing great flexibility in its use. After careful consideration, we chose Google Protocol Buffers as our primary (de)serialization format for structured data exchange. This migration allows us to reduce the overall system complexity and greatly improve the reliability of the metadata collection and the performance of our online services in general. We will present this new framework through its software architecture overview, providing details about our staged and non-disruptive migration process as well as details of the implementation of pluggable components to provide future improvements without compromising stability and availability of services.
High-resolution switched digital regulators are disclosed having fast cross corner and variable temperature response, with constrained ripple. The strength of the power transistors utilized by the regulator are adjusted to control the current delivered to the load. The regulators utilize a slow control loop in parallel with a primary fast switching loop. The slow loop uses the switching signal of the primary loop to estimate the load current and set the power transistor size accordingly.
Trajectory-control laws based on singular-perturbation theory and nonlinear dynamical modeling. Nonlinear maneuver autopilot commands flight-test trajectories of F-15 airplane. Underlying theory of controller enables separation of variables processed in fast and slow control loops, reducing amount of computation required.
Purpose: This paper describes the system for the dose delivery currently used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. Methods: CNAO Foundation, Istituto Nazionale di Fisica Nucleare and University of Torino have designed, built, and commissioned a dose delivery system (DDS) to monitor and guide ion beams accelerated by a dedicated synchrotron and to distribute the dose with a full 3D scanning technique. Protons and carbon ions are provided for a wide range of energies in order to cover a sizable span of treatment depths. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. For the CNAO beam lines, these operations are performed by the DDS. The main components of this system are two independent beam monitoring detectors, called BOX1 and BOX2, interfaced with two control systems performing the tasks of real-time fast and slow control, and connected to the scanning magnets and the beam chopper. As a reaction to any condition leading to a potential hazard, a DDS interlock signal is sent to the patient interlock system which immediately stops the irradiation. The essential tasks and operations performed by the DDS are described following the data flow from the treatment planning system through the end of the treatment delivery. Results: The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers, and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by three years of system activity needing rarely more than regular maintenance and working with 100% uptime. Four identical and independent DDS devices have been tested showing comparable performances and are presently in use on the CNAO beam lines for clinical activity. Conclusions: The dose delivery system described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. At the time of writing, it has been used to treat more than 350 patients and it has proven to guide and control the therapeutic pencil beams reaching performances well above clinical requirements. In particular, in terms of dose accuracy and stability, daily quality assurance measurements have shown dose deviations always lower than the acceptance threshold of 5% and 2.5%, respectively.
Infection is often referred to as a race between pathogen and immune response. This metaphor suggests that slower growing pathogens should be more easily controlled. However, a growing body ofevidence shows that many chronic infections are caused by failure to control slow growing pathogens. The slow growth of pathogens appears to directly affect the kinetics of the immune response. Compared with the response to fast growing pathogens, the T cell response to slow pathogens is delayed in its initiation, lymphocyte expansion is slow and the response often fails to clear the pathogen, leading to chronic infection. Understanding the 'rules ofthe race' for slow growing pathogens has important implications for vaccine design and immune control of many chronic infections.
This is an investigation of the control requirements for variable pitch wind turbine generators connected to electric power systems. The requirements include operation in very small as well as very large power systems. Control systems are developed for wind turbines with synchronous, induction, and doubly fed generators. Simulation results are presented. It is shown how wind turbines and power system controls can be integrated. A clear distinction is made between fast control of turbine torque, which is a peculiarity of wind turbines, and slow control of electric power, which is a traditional power system requirement.
A new methodology for adaptive sliding mode control (ASMC) has been widely used to improve the control performance in various systems. This method exhibits several advantages, including low sliding mode control (SMC) chattering, no knowledge of the system disturbance bound, and no overestimation of the control gain. Despite its advantages, this method can be hampered by the spike phenomenon, slow control gain convergence, and difficulty in achieving optimal performance under varying disturbances. Consequently, this article proposes a spike-free ASMC method with a disturbance observer (DOB) to address these problems. Previous ASMC methods have been analyzed via simulations to verify the aforementioned problems. Here, this analysis highlights the need for disturbance compensation and improvements in the SMC gain adaptation law. Therefore, a DOB is designed to mitigate the spike phenomenon by compensating for disturbances. Subsequently, an SMC gain adaptation law based on disturbance error estimation is designed to eliminate the spike phenomenon completely. The proposed adaptation law makes the SMC gain to converge to a slightly higher value than the disturbance estimation error. Consequently, the proposed method not only eliminates the spike phenomenon, but also ensures optimal performance under varying disturbances. The performance of the proposed method is experimen tally validated through a comparative study.
AbstractControlling the formation of hybrid perovskite thin films is crucial in obtaining high‐performance optoelectronic devices, since factors like morphology and film thickness have a profound impact on a film's functionality. For light‐emitting applications grain sizes in the sub‐micrometer‐range have previously shown enhanced brightness. It is therefore crucial to develop simple, yet reliable methods to produce such films. Here, a solution‐based synthesis protocol for the on‐substrate formation of MAPbBr3 (MA = methylammonium) nanostructures by adding the bifunctional rac‐3‐aminobutyric acid to the precursor solution is reported. This synthesis route improves key optical properties such as photoluminescence quantum yields and life times of excited states by inducing a controlled slow‐down of the film formation and suppressing agglomeration effects. In situ spectroscopy reveals a delayed and slowed down crystallization process, which achieves synthesis of perovskite structures with much reduced defect densities. Further, aggregation can be controlled by the amount of amino acid added and adjusting the synthesis protocol allows to produce cubic crystallites with targeted size from nanometer to micrometer scales. The nanocrystalline MAPbBr3 samples show enhanced amplified spontaneous emission (ASE) intensities, reduced ASE thresholds and purer ASE signals, compared to pristine films, even under intense optical driving, making them promising structures for lasing applications.
Procedure developed for slow release of reagent chemicals into solutions. Simple and inexpensive and not subject to failure of equipment. Use of toothpaste-type tube or pump dispenser conceivably provides more controlled technique for storage and dispensation of gel matrix. Possible uses include controlled, slow release of reagents in chemical reactions, crystal growth, space-flight experiments, and preformed gel medications from packets.
Abstract Physiological coherence has been related with a general sense of well‐being and improvements in health and physical, social, and cognitive performance. The aim of this study was to evaluate the relationship between acute stress, controlled breathing, and physiological coherence, and the degree of body systems synchronization during a coherence‐generation exercise. Thirty‐four university employees were evaluated during a 20‐min test consisting of four stages of 5‐min duration each, during which basal measurements were obtained (Stage 1), acute stress was induced using validated mental stressors (Stroop test and mental arithmetic task, during Stage 2 and 3, respectively), and coherence states were generated using a controlled breathing technique (Stage 4). Physiological coherence and cardiorespiratory synchronization were assessed during each stage from heart rate variability, pulse transit time, and respiration. Coherence measurements derived from the three analyzed variables increased during controlled respiration. Moreover, signals synchronized during the controlled breathing stage, implying a cardiorespiratory synchronization was achieved by most participants. Hence, physiological coherence and cardiopulmonary synchronization, which could lead to improvements in health and better life quality, can be achieved using slow, controlled breathing exercises. Meanwhile, coherence measured during basal state and stressful situations did not show relevant differences using heart rate variability and pulse transit time. More studies are needed to evaluate the ability of coherence ratio to reflect acute stress.
The LSST Camera is the sole instrument for the NSF-DOE Vera C. Rubin Observatory and consists of a 3.2 gigapixel focal plane mosaic with in-vacuum controllers, dedicated guider and wavefront CCDs, a three-element corrector whose largest lens is 1.55m in diameter, six optical interference filters covering a 320-1050nm band pass with an out-of-plane filter exchange mechanism, and camera slow control and data acquisition systems capable of digitizing each image in 2 seconds.
Code of Federal Regulation (CFR) 10 CFR 830, Nuclear Safety Management [1], explicitly identifies hazardous materials in addition to radioactive materials when establishing the scope of materials that must be evaluated in Hazard Category (HC) 1, 2, and 3 nuclear facilities. This inclusion has led to a near decade-long progression of more and more rigorous application of chemical hazard controls in these facilities. The progressive addition of more rigorous chemical hazard controls has occurred across the Department of Energy (DOE) Complex, having been driven by contractors and regulators alike. However, chemical hazards in other DOE facilities have been, and continue to be, controlled using traditional industrial safety centered strategies. Thus, identical chemical hazards are controlled using dramatically different approaches based solely on the facility type. Not only are the controls different, the analysis and derivation rigor and requirements are also significantly different. In particular, chemical control derivation and application in non-nuclear facilities are much less onerous than the comprehensive hazard analysis process used in nuclear facilities, even in circumstances in which chemicals are not initiators to, or do not exacerbate a nuclear event. While the derivation and control approaches used in these two types of facilities are disparate, the safety results are similarly effective based on a review of reported chemical events from 2014 through 2018. While both approaches achieve comparable safety outcomes, the approach used in nuclear facilities results in significantly greater preparation costs and implementation costs. Furthermore, the problem with the differing approach is not relegated to the control preparation and implementation burden. The operational impact of potentially unnecessary controls slows mission completion without a corresponding increase in safety, not to mention the dilution of the importance of Technical Safety Requirements. The proposed solution must first include a critical and thorough examination of DOE Complex and top-tier chemical industry chemical hazard control practices, coupled with a similar examination of the driving facility regulatory requirements. Results from the examination can then be used to fuel a bold departure from current chemical control practices in Hazard Category 1, 2, and 3 nuclear facilities. Development of an improved and consistent chemical hazard control process would follow, one that continues to ensure safety while accelerating mission completion and significantly reducing the burden associated with chemical hazard control development and implementation. The improved process must establish a hierarchy where radiological hazards are addressed using safety class and safety significant controls and chemical hazards are addressed using overarching safety management programs (with limited unique exceptions). The improved Hazard Category 1,2, and 3 nuclear facility chemical hazard control strategy, while compliant with 10 CFR 830 [1], would be founded on the requirements in 10 CFR 851, Worker Safety and Health Program [2], and the complementary DOE O 151.1D, Comprehensive Emergency Management System [3]. In this way, the Hazard Category 1, 2, and 3 nuclear facility chemical hazard control strategy would, wherever appropriate, be the same process used at other DOE Complex facilities. Ultimately, the improved process will maintain safety and significantly reduce costs and life cycle risk through faster mission completion. (authors)
This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.
Highlights: • A new semiorganic single crystal of LSO grown by slow evaporation technique. • Morphological studies of the LSO crystal deduced by BFDH law. • In the UV–vis spectrum wide transparent region and large band gap were found. • SHG is equal to KDP crystal and d{sub 33} was found to be equal to 6pC/N. • Grown crystal belongs to softer category. - Abstract: New semiorganic crystal of lithium sulfate monohydrate oxalate (LSO) for nonlinear application was synthesized by controlled slow evaporation method. The growth rate of various planes of the grown crystal was estimated by morphological study. Single crystal XRD analysis confirmed that the crystal belongs to triclinic lattice with space group P1. High transparency (∼95%) with large band gap (4.57 eV) was analyzed by UV–vis studies. FTIR and Raman spectroscopy were used to identify various functional groups present in the LSO crystal. SHG efficiency was found to be equal to the KDP crystal. Thermal stability (up to 117.54 °C) and melting point (242 °C) of the crystal were studied by TG-DTA. In dielectric measurements, the value of dielectric constant decreases with increase in frequency. Hardness studies confirmed soft nature of crystals. The piezoelectric coefficient was found to be 6pC/N along [0 0 1].
Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.
This paper simulates seven transient experiments with geometrical movements performed at the GIACINT facility of Belarus. These experiments include three slow control rods insertion in more than 25 s, one fast control rod insertion in less than 1 s, and three water moderator draining transients. In the fast control rod insertion experiment, the control rods are first pushed by a mechanical spring and then let fall by gravity in the assembly. In this experiment, the control rods speed varies because of the initial spring force, the gravitational acceleration, and the water buoyancy force. In all other transient experiments, the geometry change occurs with a constant speed. The Serpent computer program was utilized to simulate these transient experiments with geometrical changes by performing two separate computations. One time-independent computation is performed in criticality mode and the other time-dependent computation is performed in dynamic-source mode. The first computation writes the neutron population and delayed neutron precursors for starting the transient simulation. The second computation divides the transient time into several time bins, reads the two files from the first computation, and updates them at the end of each time bin. The Serpent simulation results obtained for this set of experiments are in good agreement with the time dependent experimental measurements. In addition, Serpent and MCNP simulations results show an excellent agreement for the water moderator transient