At least 37 records · Page 2

Integrating More Solar with Smart Inverters: Preprint

In Hawai'i, the relatively high cost of electricity costs coupled with various incentives have made it cost-effective to install solar photovoltaics (PV) on residential homes and larger central-station PV plants. On some of the islands, PV has reached over 50% of the installed generation capacity base. To make sure these inverter-based PV plants can maintain stable and safe operations, new smart inverter functionality is being evaluated and demonstrated at significant scale across the islands This paper describes research conducted to validate high PV penetration scenarios with smart inverters and recent progress on the use of these advanced inverter grid support functions in actual power grids in Hawai'i.

14 SOLAR ENERGY↗

Data-driven based coordinated smart inverter control for distributed energy resources

Smart inverters (SI) for distributed energy resources (DER) are becoming popular since they have the ability to stabilize as well as restore the voltage and frequency of power systems. Aiming at establishing the mathematical models combined with SI control methods, multiple optimization methods are developed. However, the computational complexity of solving such a mathematical model with various uncertainties limits the real-time application of the SI control. To conquer this challenge, a data-driven-based SI control approach is developed to achieve coordinated control in the high penetration DER system. First, an optimization problem for maximizing the active power generation and minimizing the power loss is designed using the Volt/VAR control. To reduce the time consumption, the recurrent neural network (RNN) is proposed to model the relationship between the uncertainties and control actions during the offline site. The RNN with different sub-structures such as the long short-term memory cell and gated recurrent unit cell are included to enrich the diversity of features. In the last stage, different experiment comparisons, including multiple uncertainties maps and stateof- art machine learning methods, are conducted to verify the effectiveness of the proposed method based on the IEEE 123 bus power system. The results demonstrate that the proposed method can effectively achieve a rapid and coordinated control with a lower error rate.

Qiu, Wei↗

Secure Firmware Update and Device Authentication for Smart Inverters using Blockchain and Physically Uncloable Function (PUF)-Embedded Security Module

Cybersecurity of inverters has been significantly important as inverters become smarter in cyber-physical environments. However, firmware security of smart inverters against firmware attacks from various attack vectors has been less studied. Furthermore, this paper proposes a secure firmware update and device authentication method using a blockchain-based public key infrastructure (PKI) management system and a physically unclonable function (PUF)-embedded security module in a smart inverter. The proposed method is validated by experiments.

blockchain↗

On a Future for Smart Inverters with Integrated System Functions

The modern electric power grid is gradually evolving to include high penetration power electronics in a distributed architecture which will pose pressing new challenges on power quality, system control, and operation. The state-of-the-art smart inverters for solar photovoltaics may not be sufficient to address some of the stability and control challenges such as harmonic resonances due to the interactions of multiple power electronics converters. This paper discusses a future of smart inverters with integrated system functions and its associated challenges, and identifies smart inverter research trends and features in the context of flexible control architectures. Future power electronics research will shift from hardware solutions to more control solutions with integrated system functions under distributed power grid scenarios with small-scale power electronics interfaced with distributed generations and loads.

Xue, Yaosuo↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Real-Time Testbed for Studying Cyberattacks and Defense in DER-integrated Smart Inverter Systems

In this paper, we propose a Hardware-in-the-Loop (HIL) simulation testbed suitable for the implementation and testing of realistic cyberattacks on grid-tied smart inverter systems integrated with Distributed Energy Resources (DER) that use the Distributed Network Protocol-3 (DNP3) protocol for communications between grid components. Specifically, our testbed combines a Real-Time Digital Simulator (RTDS) NovaCor device, outfitted with GNETx2 network interface cards, a gridtied DER topology implemented via the RTDS software package RSCAD, and a custom virtual network that emulates a man in the middle attacker. The Man-in-the-Middle (MITM) attacker captures DNP3 traffic and falsifies telemetry data in DNP3 packets to trigger unwarranted commands from a DNP3 controller that exploit smart inverter grid support functions. We choose DNP3 and implement grid support functions according to the IEEE Std. 1547-2018 mandated for the interconnection and interoperability of DER power systems with associated power components. Furthermore, we develop a protocol payload agnostic attack detection framework that leverages the round-trip time (RTT) anomalies between DNP3 requests and responses and can detect the presence of attacks without having to analyze the payload’s contents, while balancing trade-offs between false alarm counts, missed detections, and time to detection. To facilitate further research, we publicly release benign and attack network traffic exchanged between various sensors, controllers, and actuators in our grid-tied inverter testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Stabilizer based Predictive Control Scheme for Smart Inverters in Weak Grid

This paper presents a self-stabilization mechanism based on finite-set model predictive control (FCS-MPC) framework for smart inverters operating in weak grid conditions. As weak grid’s large parasitic impedance and low short-circuitratio (SCR) challenge the stable operation of grid-connected inverters. Specifically, the inverter may experience frequencies that might excite the LCL filter resonance phenomenon. The inverter stability collapses if this LCL resonance is triggered. To address this issue, a robust predictive controller is proposed that features a self-stabilization mechanism for smart inverters interacting with a weak grid. The proposed methodology utilizes the idea that in stiff grid conditions the grid current feedback (GCF) is stable and in weak grid conditions the inverter current feedback (ICF) is stable. Therefore, the proposed FCS-MPC toggles between GCF and ICF to achieve inherent LCL filter resonance damping. The toggling action between GCF and ICF is leveraged by comparing the moving RMS grid current with threshold current as a constrained in the proposed FCS-MPC cost function. The theoretical analyses are verified by several case studies for a single-phase grid-connected inverter. The analysis and results demonstrated that the proposed FCS-MPC operates well under weak, ultra-weak and stiff grid conditions.

Umar, Muhammad Farooq↗

Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

14 SOLAR ENERGY↗

Energy-Storage Fed Smart Inverters for Mitigation of Voltage Fluctuations in Islanded Microgrids

The continuous integration of intermittent low-carbon energy resources makes islanded microgrids vulnerable to voltage fluctuations. Besides, different dynamic response of synchronous-based and inverter-based distributed generation (DG) units can result in an instantaneous power imbalance between supply and demand during transients. As a result, the ac-bus voltage of microgrid starts oscillating which might have severe consequences such as blackouts. This paper modifies the conventional control scheme of battery energy storage systems (BESSs) to participate in improving the dynamic behavior of islanded microgrids by mitigating the voltage fluctuations. A piecewise linear-elliptic (PLE) droop is proposed and employed in BESS to achieve an enhanced voltage profile by injecting/absorbing reactive power during transients. In this way, the conventional inverter implemented in BESS turns into a smart inverter to cope with fast transients. Using the proposed approach in this paper, any linear droop curve with a specified coefficient can be replaced by a PLE droop curve. Compared with linear droop, an enhanced dynamic response is achieved by utilizing the proposed PLE droop. Case study results are presented using PSCAD/EMTDC to demonstrate the superiority of the proposed approach in improving the dynamic behavior of islanded microgrids.

Pilehvar, Mohsen S.↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Smart Inverter Utility Experience in Hawaii

This publication on utility experience with advanced inverters is a part of a tutorial at the 2019 IEEE Power and Energy Society General Meeting titled 'Smart Inverters for Distributed Generators - Utility Applications and Experiences'. It describes lessons utilities can take from the experience of Hawaiian Electric with deployment of advanced inverter functionality. Hawaiian Electric is one of the leading U.S. utilities in terms of deployment of distributed solar photovoltaic systems and advanced inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Inverter Stability Enhancement in Weak Grids Using Adaptive Virtual-Inductance

An adaptive virtual-inductance feedforward scheme is presented in this article to enhance the stable operation of smart inverters in weak grids. In the developed scheme, the virtual inductance is updated in real time according to an adaptation law to ensure that the inverter follows the dynamic response of a robust reference model, thereby ensuring stability without the need for any grid impedance estimation. In this article, the developed scheme is validated with experimental results obtained from testing a small-scale two-level, 208-V, 2-kW inverter.

42 ENGINEERING↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Extremum Seeking Control of Smart Inverters for VAR Compensation

Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand information confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.

Arnold, Daniel↗