Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical study of advanced solar receiver tubes based on a coupled thermo-mechanical analysis for concentrated solar power tower plant

The search for more sustainable energy to match the growing energy demand begins with finding more dispatchable resources such as solar energy. As one of the promising solar technologies, concentrated solar power (CSP) has a full capacity to store thermal energy for extended operation. Nevertheless, some key components in CSP systems usually face extreme environment, such as uneven solar flux, cyclic thermal expansion, structural degradation on the solar absorber tubes in a Concentrated Solar Power Tower (CSPT) Plant. In this study, we applied Multiphysics simulation to explore the benefits of introducing optimized fins for heat transfer enhancement and uniform temperature distribution, the goal is to improve the thermal efficiency of such advanced solar absorber tubes. The results of this study can supply design guidance for the manufacturing process of absorber tubes, and eventually can benefit the solar energy community for the next generation of molten salt based CSP system.

14 SOLAR ENERGY↗

Modeling receiver flux of commercial power tower concentrating solar power plants using ray tracing: a round-robin comparison of SolTrace, Solstice, and TieSOL

This study presents a multi-stage, cross-validation comparison of three software packages for Monte Carlo ray tracing (MCRT) applied to central tower concentrating solar power (CSP) systems. The three packages evaluated are: (1) SolTrace, an open-source tool developed by the National Renewable Energy Laboratory (NREL); (2) Solstice, an open-source program created by CNRS-PROMES and Meso-Star, with enhancements for CSP applications (called solsticepy) from the Australian National University; and (3) TieSOL, a commercial software developed by Tietronix. This investigation extends previous ray tracing comparisons by incorporating models of multi-facet heliostats within a commercial-scale solar field, taking into account zoned focal lengths and canting configurations. Receiver flux distributions were compared across the tools using a series of case studies, including single-heliostat scenarios, isolated blocking situations, and comprehensive full-field simulations. The case studies were designed to diagnose differences across the models at varying levels of complexity, and to identify and resolve discrepancies as additional parameters were introduced. Key factors examined in the analysis include sun positions, heliostat location, facet and canting focus, and aimpoint strategies. The comparison aims to improve the accuracy and reliability of these tools while providing benchmark cases for validating future optical modeling tools.

14 SOLAR ENERGY↗

Development of High Temperature (>700°C) Molten Salt Pump Technology for Generation 3 Solar Power Tower Systems

Bearings are required for long-shafted pumps historically used in concentrating solar thermal power applications. For molten chloride salts, bearings for such service conditions are not commercially available, nor has a design been demonstrated to work. Therefore, a project was sponsored by the Department of Energy’s Solar Energy Technologies Office for the development and demonstration of a submerged bearing for use in chloride salt pumps. This project’s tasks covered the tribological testing of candidate materials and the design, fabrication, testing, and post-test analysis of full-scale salt-compatible bearings. This work expands upon previous work. The effects of potential particulate in the salt were investigated through tribological bench testing. Through 11 tests, the MgO particulate size and concentration in a molten chloride salt were varied, and the effects on friction, wear rate, and wear characteristics were recorded. Novel journal bearings for chloride salt service were designed and fabricated based on these results. The bearings were of a relevant scale (i.e., for a 1.5 in. pump shaft) to demonstrate the technology with respect to further scale-up. The bearings were made of Haynes 244 and Yttria Partially Stabilized Zirconia. A custom bearing test rig, salt tanks, and associated infrastructure (e.g., heaters, tanks, transfer lines, gas flow control) were designed, procured, and installed. A few issues were encountered in the system fabrication process, resulting in delay of the project schedule. The system was successfully fabricated and assembled. Heating, cover gas, and pump motor systems were integrated into the control logic. This progress of the bearing test system represents a significant step forward towards demonstrating this promising technology. Nevertheless, the project ended before testing of the full-scale bearings could be performed.

14 SOLAR ENERGY↗

Lunar stone saw

This project addresses the problem of cutting lunar stones into blocks to be used to construct shelters to protect personnel and equipment from harmful solar radiation. This plant will manufacture 6 in x 1 ft x 2 ft blocks and will be located near the south pole to allow it to be in the shade at all times. This design uses a computer controlled robot, a boulder handler that uses hydraulics for movement, a computer system that used 3-D vision to determine the size of boulders, a polycrystalline diamond tipped saw blade that utilizes radiation for cooling, and a solar tower to collect solar energy. Only two electric motors are used in this plant because of the heavy weight of electric motors and the problem of cooling them. These two motors will be cooled by thermoelectric cooling. All other motors and actuators are to be hydraulic. The architectural design for the building as well as the conceptual design of the machines for cutting the blocks are described.

Clark, Tom↗

Thermostructural Qualification of PICA-D for NASA Planetary Science Missions

Phenolic Impregnated Carbon Ablator (PICA) has been used as the heatshield TPS material for many NASA planetary science missions. Due to a supply issue with the heritage Rayon fibers used in PICA fabrication, NASA started a project in 2017 to develop a sustainable replacement for PICA using a domestic fiber source, named PICA-D. This material has been selected as the heatshield TPS material for two upcoming NASA planetary science missions, Dragonfly mission to Titan and Mars Sample Retrieval Lander (SRL). While most PICA-D thermal and mechanical properties are very similar to PICA, early test data suggest that PICA-D is stiffer in tension in the in-plane (IP) direction, with higher strength but lower strain-to-failure. Preliminary thermostructural analysis using Finite Element Methods (FEM) tools predict IP compressive failure in the near-surface layers of PICA-D, for both Dragonfly and SRL flight environments. This talk provides an overview of the thermostructural qualification plans for PICA-D. A two-pronged approach is being pursued to demonstrate that the material and heatshield design has adequate capability for both SRL and Dragonfly design environments. The first part is to improve the accuracy of analytical predictions through a comprehensive characterization of PICA-D mechanical properties. The second, and more critical, part of the qualification approach is a subsystem-level test of PICA-D to demonstrate material capability under flight-relevant combined mechanical and thermal loads. The team is currently preparing for two test series in Sandia’s Solar Tower facility, scheduled in September 2023 and focusing on PICA-D acreage, followed by additional tests in the Solar Tower and LHMEL facilities focusing on design features and repair methods.

TPS↗

A Techno-Economic Analysis of a 50MWth Light-Trapping Cavity-Planar Solar Receiver Tower Capital Expenditures and its Cost Mitigation Strategies

To maximize thermal efficiency, the National Renewable Energy Laboratory (NREL) has proposed a light-trapping cavity-planar receiver design intended to capture energy from reradiating surfaces. This system implements a macroscale light trapping mechanism induced by panels with triangular channels, this mechanism allows for elevated temperatures on the receiver panels and in turn the temperature of the HTF; using this design coupled with the implementation of a fluidized particle flow as the HTF, it can be expected for some components to reach a peak working temperature of nearly 1000 degrees C cyclically throughout each day-night cycle. While these temperatures correlate to higher efficiency of the CSP tower they also demand intense thermomechanical properties from the materials used to make the receiver panels. In this analysis, we will list our assumptions to provide clarity on the significance of our calculation. This cost analysis will be conducted using a combination of both case study data and surveying industry to determine costs that are relevant to the current market trends. This analysis represents an early attempt to establish the Capital Expenditures required for a CSP tower of such design to determine the feasibility of implementing such a system in the industry.

concentrated solar power (CSP)↗

Techno-Economic Analysis of CSP Incorporating sCO2 Brayton Power Cycles: Trade-Off Between Cost and Performance

Concentrating solar power (CSP) plants, thanks to the implementation of cost-competitive thermal energy storage, represent a dispatchable zero-emission alternative to traditional fossil fuel power plants. Next generation solar towers are expected to adopt high temperature receivers (>700 degrees C) coupled to sCO2-based power blocks, which optimal design is generally pushed towards the maximum cycle efficiency, often neglecting the economic impact with the justification that the main share of the capital cost is represented by the heliostat field. As result, the scientific literature lacks in comprehensive studies on techno-economic evaluation of CSP+sCO2 power plants addressing the important correlation that exists between system cost and performances. This work provides a preliminary techno-economic analysis of a solar power tower comparing four different cycle configurations for the sCO2 power block. Results have been reported on a Pareto front, highlighting the tradeoff between the plant investment cost and the solar-to-electricity plant efficiency. The trends of the optimization variables and cycle results have been reported to give useful insights about proper assumptions for the sCO2 power block design. The recompressed cycle with intercooling resulted as the most promising configuration and it has been further analyzed through a comparison of different solutions on the Pareto front. The cost breakdown of the sCO2 power block has been reported to highlight which components have the greatest impact on the overall plant cost and how they vary along the optimal solutions front. Eventually, the optimization has been repeated introducing a correlation to compute the turbomachinery isentropic efficiencies, to investigate their effect on the techno- economic analysis.

concentrated solar power↗

Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System

The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.

associated liquids↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

Tower-supported solar-energy collector

Multiple-collector tower system supports three receiver/concentrators that absorb solar energy reflected from surrounding field of heliostats. System overcomes disadvantages of tower-supported collectors. Booms can be lowered during heavy winds to protect arms and collectors.

Selcuk, M. K.↗

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Dynamics of solar filaments. V - Oscillations in the H-alpha and 1548 A C IV lines

The Multichannel Subtractive Double Pass (MSDP) Spectrograph operating in the Meudon solar tower and the Ultraviolet Spectrometer and Polarimeter (UVSP) aboard the Solar Maximum Mission (SMM) satellite are used to analyze, by Fourier transform technique, time sequence observations of filaments in both the H-alpha line and in the 1548 A C IV line. The H-alpha data confirm previous findings that there are no oscillations at the location of the filament in the observed range 1-10 mHz. In the C IV line, power is observed in some parts of the filament where a steady velocity gradient is present, e.g. in the footpoints. The energy is probably due to convection motions rather than pressure oscillations.

Malherbe, J. M.↗

Evidence for gentle chromospheric evaporation during the gradual phase of large solar flares

The Multichannel Subtractive Double Pass Spectrograph of the Meudon solar tower is used to obtain high spatial resolution H-alpha line profiles during the gradual phase of three solar flares. In all cases, small blueshifts lasting for several hours are observed in the flare ribbons. By contrast, the region between the two ribbons exhibits large redshifts that are typical of H-alpha post flare loops. The blueshifts in the ribbons is interpreted as upward chromospheric flows of 0.5-10 km/s, and the possible ambiguities of the interpretation are discussed. A preliminary analysis indicates that such upflows are sufficient to supply the greater than 10 to the 16th g of mass needed to maintain a dense H-alpha postflare loop system in the corona.

Schmieder, B.↗

Dynamics of solar filaments. III - Analysis of steady flows in H-alpha and C IV lines

A statistical analysis of intensities and radial velocities of several solar plage filaments (i.e. prominences seen on the solar disk) observed at disk center is presented. Intensity and radial (= vertical) velocity maps were derived from simultaneous 2D measurements of the H-alpha chromospheric line with the Multichannel Subtractive Double Pass spectrograph operating on the Meudon solar tower, and also obtained from 2D recordings of the C IV transition-zone line (1548 A) with the UV Spectrometer and Polarimeter aboard the Solar Maximum Mission satellite. A good correlation (around 0.5) is found between intensities in both lines, as well as between velocities. Persistent upflows are measured in both lines at the filament location. The mean vertical velocities are respectively 0.5 km/s in H-alpha and 5.6 km/s in C IV. The analysis of mass fluxes suggests that C IV upflows occur in the transition region around prominences rather than below, in the chromosphere-corona transition zone.

Schmieder, B.↗