Techno-Economic Analysis of CSP Incorporating sCO2 Brayton Power Cycles: Trade-Off Between Cost and Performance
Concentrating solar power (CSP) plants, thanks to the implementation of cost-competitive thermal energy storage, represent a dispatchable zero-emission alternative to traditional fossil fuel power plants. Next generation solar towers are expected to adopt high temperature receivers (>700 degrees C) coupled to sCO2-based power blocks, which optimal design is generally pushed towards the maximum cycle efficiency, often neglecting the economic impact with the justification that the main share of the capital cost is represented by the heliostat field. As result, the scientific literature lacks in comprehensive studies on techno-economic evaluation of CSP+sCO2 power plants addressing the important correlation that exists between system cost and performances. This work provides a preliminary techno-economic analysis of a solar power tower comparing four different cycle configurations for the sCO2 power block. Results have been reported on a Pareto front, highlighting the tradeoff between the plant investment cost and the solar-to-electricity plant efficiency. The trends of the optimization variables and cycle results have been reported to give useful insights about proper assumptions for the sCO2 power block design. The recompressed cycle with intercooling resulted as the most promising configuration and it has been further analyzed through a comparison of different solutions on the Pareto front. The cost breakdown of the sCO2 power block has been reported to highlight which components have the greatest impact on the overall plant cost and how they vary along the optimal solutions front. Eventually, the optimization has been repeated introducing a correlation to compute the turbomachinery isentropic efficiencies, to investigate their effect on the techno- economic analysis.
Operational Modes of a 2.0 MWth Chloride Molten-Salt Pilot-Scale System
The limit of traditional solar-salt thermal stability is around 600 °C with ambient air as the cover gas. Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered to be state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. However, decomposition challenges occur with these salts for operation beyond 600 C. Although slightly higher limits may be possible with solar salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, molten-salt technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative salt chemistry composition, such as chlorides. In this investigation a 2.0MWth Pilot-scale CSP plant design is developed to assess thermodynamic performance potential for operation up to 720 C. Here, an Engineering Equation Solver (EES) model is developed with respect to 14 state-points from the base of a solar tower at the Sandia National Laboratories, National Solar Thermal Test Facility (NSTTF), to solar receiver mounted 120 ft. above the ground. The system design considers a ternary chloride ternary chloride (20%NaCl/40%MgCl/40%KCl by mol%) salt as the HTF, with 6 hrs. of storage and a 1 MWth primary salt to sCO2 heat exchanger. Preliminary system modelling results indicate a minimum non-dimensional Cv of 60 required for both cold and hot-side throttle recirculation valves for the operational pump operating between speeds of 1800 and 2400 RPM. Further receiver comparison study results suggest that the ternary salt requires an average 15.2% higher receiver flux with a slightly lower calculated receiver efficiency when compared to a binary carnelite salt to achieve a 2.0 MWth desired input power design.
Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant
Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.
Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module
Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.
Measurement of High-temperature Thermophysical Properties of Bulk and Coatings Using Modulated Photothermal Radiometry
This paper presents the development of instrumentation for the measurement of high-temperature thermal conductivity of bulk and coatings using a modulated photothermal radiometry (MPR) method, where a sample is heated by an intensity-modulated laser to probe into different layers of the sample. While MPR has been previously established, most of the previous studies only focus on the measurement at room temperature. The MPR has not been well studied for measurements of bulk and coating materials at high temperatures, which are increasingly important for a multitude of applications, such as materials used in the concentrating solar power (CSP) plants and the nuclear reactors. MPR is a non-contact technique that utilizes the intrinsic thermal emission from the specimens for thermometry, which is favorable for measurements at high temperatures in harsh environment. The authors designed and utilized a sample holder suitable for high temperature measurement up to 973 K with good temperature uniformity within the sample. The high-temperature MPR setup was validated by measuring bulk materials with known thermal conductivity. The setup and technique were then extended to the measurement of black solar-absorbing coatings of 10 to 50 μm thick on various substrates by modulating the frequency of the laser heating beam and the thermal penetration depth. Here, the studies showed that thermal conductivities of typical solar-absorbing coatings are 0.4 ~ 0.8 W m -1 K -1 , indicating a possibly large temperature drop within the coating under high solar irradiation flux, such as over 1000-sun for central solar towers in CSP plants.
Scalable Solar Fuels Production in A Reactor Train System by Thermochemical Redox Cycling of Novel Nonstoichiometric Perovskites
Hydrogen production via two-step thermochemical water splitting redox cycles using nonstoichiometric redox-active metal oxides has the potential to dramatically increase fuel production rates. At moderate-to-low water splitting temperatures, surface reaction kinetics co-limit the process. In such cases, stable and high surface area microstructures that allow exploitation of the full thermodynamic potential of the materials are essential as is tight thermal integration of the reactor module. This project’s goals were the development of novel nonstoichiometric perovskite oxides with high stability and favorable thermodynamic and kinetic properties, to optimize their microstructure for maximizing the fuel productivity, and to build a prototype reactor train system (RTS) comprising at least one reactor to meet specific performance targets: (1) capable of an in-house solar thermochemical hydrogen (STCH) productivity ≥ 12 mL g -1 for stable continuous operation ≥ 20 cycles; and (2) demonstration of scalable solar fuels production at practical solar reactor level in an industrial-scale concentrated solar tower (CST) using developed perovskites to achieve a hydrogen production rate ≥ 1 g h -1 .
National Solar Thermal Test Facility: Operations & Maintenance Report
The NSTTF O&M Project continues the operation and maintenance activities of the existing critical capabilities and infrastructure at the NSTTF. This project is to support and assure the success of Solar Heat for Industrial Process in the United States and the larger global community by ensuring the NSTTF is a safe and operational facility. The primary goal of this project will be to maintain the solar tower and heliostat field while also allowing NSTTF staff to improve processes for operations and maintenance. This includes expanding our preventative maintenance program, inventory systems, and our data sharing capabilities. Additionally, this will support an outreach program with regular seminars, sharing of data, and the release of open-source software to support heliostat metrology
Roadmap to Advance Heliostat Technologies for High Temperature Solar-Thermal Systems
Since its establishment, the Heliostat Consortium (HelioCon) has made substantial progress toward closing many of the gaps in concentrating solar power (CSP) research. Numerous techno-economic studies have been performed, investigating topics ranging from the trade-off between size and temperature for industrial process heat applications to optimization of the heliostat design itself for various applications. Significant improvements have been made in optical metrology techniques, with first steps toward in situ measurement of heliostat fields. Several standards have been, and continue to be, developed with the coordination of an international group of CSP industry participants. Training programs have been developed, with universities including CSP in their engineering curricula, and many public webinars have been held to provide broad access to the latest CSP research. Improved CSP components such as mirror facets and wireless communication systems have been developed, and the solar tower at Sandia National Laboratories has been upgraded with a testbed for closed-loop controls research and development. Field deployment challenges involving heliostat foundations and sensitive wildlife habitats have been explored, with progress made toward methods for streamlining project development and permitting. Additional knowledge has been added to the body of work on wind behavior of heliostats and arrays of heliostats, with progress made toward a holistic understanding of wind design methods. Finally, techniques have been developed and demonstrated for assessing soiling conditions at a proposed project site, with predictive models for the soiling rate showing good results. Taking these results together, HelioCon has contributed greatly to the global CSP research and development effort over the past several years.
Cyclic Thermal and Structural Testing of a Hot Particle Storage Bin
Thermal energy storage is a key element in concentrating solar energy systems. In 2017 a Roadmap toward a third-generation system that could meet the SunSHOT goals of 0.06 $/kWe recommended increasing temperatures to > 700° C for heat transfer media to in-crease thermal efficiencies and lower levelized costs of heat. In 2021, the U.S. Department of Energy selected the particle pathway, G3P3, to build a 1 MWt prototype solar tower with 6 MWh thermal energy storage at the NSTTF in Albuquerque, NM. Of the primary components, the falling particle receiver, and particle-to-sCO2 heat exchanger have been demonstrated at the 250 kWt capacity. The storage component is now being demonstrated as part of the G3P3-USA and G3P3-KSA pilot plants. Storage bin liner materials have been demonstrated by KSU in 2016 and 2019. A flowing particle storage container was demonstrated in 2020 by KSU. The testing presented in this work will be the first to test the particle to wall interactions with mono-lithic refractory insulation, and to validate a transient thermal transport model with the unique kinetics of bulk solids in funnel-flow where cooler particles near the walls flow inward toward a hot central flow channel. This work will also de-risk and characterize the specific design of the G3P3-USA storage bin.
Case Study: The Tower Companies' Commercial Office Solar PV
This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.
A Method for Projecting Cloud Shadows Onto a Central Receiver Field to Predict Receiver Damage
This work demonstrates methods of mapping high-spatial-resolution direct normal irradiance (DNI) data from satellites, Total Sky Imagers (TSIs), and analogous data sources onto a heliostat field for characterizing the spatial and temporal variation of the incident flux on a central receiver tower during cloud transient events. The mapping methods are incorporated into an optical software module that interfaces with CoPylot–SolarPILOT’s python API– to provide computationally efficient optical simulation of the heliostat field and the solar power tower. Eventually, this optical model will be incorporated into optimization models whereby a plant operator can understand the effects of cloud transient events on overall power production and receiver lifetime due to creep-fatigue damage and therefore make better informed decisions about receiver shutdown events. By more accurately modelling the effects of cloud events on receiver flux maps, this work may determine the magnitude and frequency of thermal cycling on receiver tubes and panels using actual or realistic cloud shapes instead of averaged DNI values–which may undercount the total cycle number. This work may also prevent unnecessary plant shutdowns due to overly precautionary control strategies and characterize the relative impact of various cloud types on receiver life. We plan to eventually integrate this methodology into the System Advisor Model (SAM) to improve performance model accuracy during periods of cloudiness. In this paper, we demonstrate generating DNI maps and mapping them to a solar field in CoPylot using 10 m resolution data from publicly available Sentinel-2 satellite data over the Crescent Dunes plant.
Final Report for CSP Tower Public Opinion and Education Project
As part of the CSP Plant Optimization Study for the California Power Market (DE-EE0009809) the project wanted to understand the public’s opinion of the technology and and explore the types of community engagement that is needed to support such development. The initial objectives for the public perception activities were twofold. The primary objective was to gather public opinion and feedback from the communities living near the two operating solar power tower plants, Ivanpah and Crescent Dunes, and to distill lessons learned from the community engagement conducted before, during, and after the plants were developed to inform future development. This included outreach to nearby airports. The other objective was to gauge public opinion about large-scale solar, specifically CSP towers, to start educating the public on the benefits and to begin building relationships with communities of interest, initially targeting the Kingman, Arizona area. The objectives shifted after the first exploratory trip to Ivanpah and Kingman, however, as it became apparent that it would be challenging to gather public opinion from the community surrounding Ivanpah that could be useful for other community profiles, and the company wasn’t ready to address the concerns in Kingman. Another area was chosen, therefore, to represent those where future development is possible. The recently published Lawrence Berkeley National Lab Perceptions of Large-Scale Solar Project Neighbors Study exemplified public perception polling based on social science and served as the foundation for the survey questions taken to the field. The intent was to ensure that people knew their input was valued and that the time they spent was valuable for the participant as well. It has been noted in the literature that in-person interaction has greater benefits than activities online or via mail, as well as limits the expense.
Damage modeling of power tower receiver tubes using the SRLIFE tool
Concentrating Solar Power (CSP) molten-salt central receivers are subject to high, transient incident flux during daily operation. The resulting creep-fatigue damage impacts the receiver’s reliability and restricts the permissible incident flux distribution for a given receiver. This paper aims to reduce CSP plants’ levelized cost of electricity by developing a methodology to predict lifetime and identifies the primary damage mechanism (creep vs fatigue) for any given fluid temperature and temperature gradient. Results are presented in the form of a damage map that serves as a valuable operation guide and design tool. Damage maps can be used to reduce maintenance costs by improving reliability and reduce receiver capital costs by better utilizing the receiver area. FEA simulation and damage modeling of tubes subject to asymmetrical flux conditions is performed in the open-source receiver design tool srlife. Parametric studies are performed over a range of inner tube temperatures and thermal gradients for A230, 316H, 740H, A282, A617, and 800H high temperature alloys. Damage maps are presented for each alloy. A parametric, FEA-based methodology is presented for comparison of fatigue-creep ratios and prediction of tube lifetime based on the critical thermal operating conditions. Fatigue is found to be negligible compared to creep for almost every case. Here, this finding suggests that fatigue effects associated with cloud events are insignificant compared to creep at these high temperature operating conditions. Additionally, lifetime predictions identify thermal conditions where small changes in operating conditions can result in large changes in predicted lifetime.
AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation
Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.
Heliostat Aiming Strategies for Arbitrary Flux Profiles for High Temperature Gas-Based Receivers
High temperature gas-based receivers are seen as one potential path toward achieving the next generation of concentrated solar power tower systems. A key challenge associated with high temperature, high pressure heat transfer fluids is the lifetime of receiver containment materials. Achieving the desired lifetime while also designing an efficient receiver requires implementation of unique flux profiles, tailored to place high fluxes at cold fluid injection points. An aimpoint selection methodology was developed in the present study to allow user-defined flux profiles to be prescribed for a receiver. The methodology was implemented in NREL's open-source software SolarPILOT, modifying the existing “image size priority” aimpoint strategy. A case study for a tubular gas-based receiver is presented, examining the effect of various parameters on the ability to replicate the desired flux profile.
Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems
This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.