Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Water Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solar-Heated Water at a Motel--Mobile, Alabama

Solar-assisted hot-water system for a new 122-unit motor inn in Mobile, Alabama, generates more than half the energy needed for hot-water heating at motel each year. System consists of 93 flat-plate collectors, 2,500 gallon (9,500 1) insulated storage tank located outdoors, heat exchangers and controls. Electronic thermometers, measuring the temperatures at 22 locations monitor system performance.

Source record↗

Solar water heating system for a lunar base

An investigation of the feasibility of using a solar water heater for a lunar base is described. During the investigation, computer codes were developed to model the lunar base configuration, lunar orbit, and heating systems. Numerous collector geometries, orientation variations, and system options were identified and analyzed. The results indicate that the recommended solar water heater could provide 88 percent of the design load and would not require changes in the overall lunar base design. The system would give a 'safe-haven' water heating capability and use only 7 percent to 10 percent as much electricity as an electric heating system. As a result, a fixed position photovoltaic array can be reduced by 21 sq m.

Somers, Richard E.↗

Role of Solar Water Heating in Multifamily Zero Energy Homes

With support from the U.S. Department of Energy Building America Program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in the spring of 2014, and CARB has been monitoring the performance of the water-heating systems since May 2014.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study on the application of NASA energy management techniques for control of a terrestrial solar water heating system

This paper addresses the potential for enhanced solar system performance through sophisticated control of the collector loop flow rate. Computer simulations utilizing the TRNSYS solar energy program were performed to study the relative effect on system performance of eight specific control algorithms. Six of these control algorithms are of the proportional type: two are concave exponentials, two are simple linear functions, and two are convex exponentials. These six functions are typical of what might be expected from future, more advanced, controllers. The other two algorithms are of the on/off type and are thus typical of existing control devices. Results of extensive computer simulations utilizing actual weather data indicate that proportional control does not significantly improve system performance. However, it is shown that thermal stratification in the liquid storage tank may significantly improve performance.

Swanson, T. D.↗

Solar Water Heating with Low-Cost Plastic Systems

Federal buildings consumed over 392,000 billion Btu of site delivered energy for buildings during FY 2007 at a total cost of $6.5 billion. Earlier data indicate that about 10% of this is used to heat water.[2] Targeting energy consumption in Federal buildings, the Energy Independence and Security Act of 2007 (EISA) requires new Federal buildings and major renovations to meet 30% of their hot water demand with solar energy, provided it is cost-effective over the life of the system. In October 2009, President Obama expanded the energy reduction and performance requirements of EISA and its subsequent regulations with his Executive Order 13514.

Solar, Water, Heating, Low-Cost, Plastic↗

Indirect Solar Water Heating in Single-Family, Zero Energy Ready Homes

In western Massachusetts, an affordable housing developer built a community of 20 homes with the goal of approaching zero energy consumption. In addition to excellent thermal envelopes and photovoltaic systems, the developer installed a solar domestic hot water (SDHW) system on each home. The Consortium for Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America research team, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of the Solar Building Test Facility

The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

Jensen, R. N.↗

Calculation of the temperature of the internal surface of the heat-removing channel wall of the ray-absorbing heat-exchange panels of flat-plate solar water-heating collectors

The results of numerical research on the determination of the temperature value of the internal surface of the heat-removing channel (HRC) walls of the light-absorbing heat-exchange panels (LAHPs) with the tubeon- sheet and thin-parallelepiped form of flat-plate solar water-heating collectors (FPSWHCs) are presented. The research method is based on compilation of the system of the balance equations for the light-absorbing plate (LAP) and HRCs of the LAHPs of the studied types and their designs with respect to the desired parameter. A practical example of calculation of the determination of the temperature value of the internal surface of the HRC wall of the tube-on-sheet LAHP, where the results of experimental research on the determination of the specific thermal efficiency of the mean-quality FPSWHC in full-scale terms, as well as laboratory and numerical research on determination of the optical and thermotechnical indicators of the copper tube-on-sheet LAHP.

14 SOLAR ENERGY↗

Solar space heating for the Visitors Center, Stephens College, Columbia, Missouri

The solar energy system located at the Visitors' Center on the Stephens College Campus, Columbia, Missouri is discussed. The system is installed in a four-story, 15,000 square foot building. The solar energy system is an integral design of the building and utilizes 176 hydronic flat plate collectors which use a 50 percent water ethylene blycol solution and water-to-water heat exchanger. Solar heated water is stored in a 5,000 gallon water storage tank located in the basement equipment room. A natural gas fired hot water boiler supplies hot water when the solar energy heat supply fails to meet the demand. The designed solar contribution is 71 percent of the heating load.

Source record↗

Determination of the Convective Heat-Exchange Coefficient in Inner Channels of Light-Absorbing Heat-Exchange Panels of Flat-Plate Solar Water-Heating Collectors Based on the Results of Their Short-Term Thermal Testing in Full-Scale Conditions

The results of investigations to determine the convective heat-exchange coefficient in the inner heat-exchange channels (HECs) of the light-absorbing heat-exchange panels (LAHPs) of flat-plate solar water-heating collectors (FPSWHCs) are given based on the results of their short-term heat testing in fullscale quasi-stationary conditions. The research method is based on determining the value of the required parameter from the heat-balance equation formed for the inner surfaces of the LAHP HEC walls. The structures of the flow LAHPs with a sheet-piped and thin parallelepiped form are selected as the test objects. The thermal tests of the FPSWHC are carried out during the near-midday hours of the light day to ensure the quasi-stationary mode condition. The reliability of the proposed method and results of the investigations is proved by comparing the values of the thermal-efficiency coefficients of the FPSWHC LAHPs obtained using two independent approaches.

14 SOLAR ENERGY↗

Study Design And Realization Of Solar Water Heater

Solar is one of the most easily exploitable energy, it is moreover inexhaustible. His applications are many and are varied. The heating of the domestic water is one of the most immediate, simplest and also of most widespread exploitation of the solar energy. Algeria, from its geographical situation, it deposits one of the largest high sun surface expositions in the world. The exposition duration of the almost territory exceeds 2000 hours annually and can reach the 3900 hours (high plateaus and Sahara). By knowing the daily energy received by 1 m{sup 2} of a horizontal surface of the solar thermal panel is nearly around 1700 KWh/m{sup 2} a year in the north and 2263 KWh/m{sup 2} a year in the south of the country, we release the most important and strategic place of the solar technologies in the present and in the future for Algeria. This work consists to study, conceive and manufacture solar water heating with the available local materials so, this type of the energy will be profitable for all, particularly the poor countries. If we consider the illumination duration of the panel around 6 hours a day, the water heat panel manufactured in our laboratory produce an equivalent energy of 11.615 KWh a day so, 4239 KWh a year. These values of energy can be easily increased with performing the panel manufacture.

14 SOLAR ENERGY↗

Thermal phase diagram of acetamide-benzoic acid and benzoic acid-phthalimide binary systems for solar thermal applications

Thermal properties of Acetamide (AM) – Benzoic acid (BA) and Benzoic acid (BA) – Phthalimide (PM) binary eutectic systems are theoretically calculated using thermodynamic principles. We found that the binary systems of AM-BA at 67.6 : 32.4 molar ratio, BA-PM at 89.7 : 10.3 molar ratio form eutectic mixtures with melting temperatures ~ 54.5 °C and 114.3 °C respectively. Calculated latent heat of fusion for these eutectic mixtures are 191 kJ/kg and 146.5 kJ/kg respectively. These melting temperatures and heat of fusions of these eutectic mixtures make them suitable for thermal energy storage applications in solar water heating and solar cooking systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solar heating and hot water system installed at Arlington Raquetball Club, Arlington, Virginia

A solar space and water heating system is described. The solar energy system consists of 2,520 sq. ft. of flat plate solar collectors and a 4,000 gallon solar storage tank. The transfer medium in the forced closed loop is a nontoxic antifreeze solution (50 percent water, 50 percent propylene glycol). The service hot water system consists of a preheat coil (60 ft. of 1 1/4 in copper tubing) located in the upper third of the solar storage tank and a recirculation loop between the preheat coil and the existing electric water heaters. The space heating system consists of two separate water to air heat exchangers located in the ducts of the existing space heating/cooling systems. The heating water is supplied from the solar storage tank. Extracts from site files, specification references for solar modifications to existing building heating and hot water systems, and installation, operation and maintenance instructions are included.

Source record↗