Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid Oxide Fuel Cell (SOFC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A highly oxygen reduction reaction active and CO 2 durable high-entropy cathode for solid oxide fuel cells

One big obstacle for the oxygen reduction reaction (ORR) electrode in solid oxide fuel cells (SOFCs) is the poor reaction activity and fast degradations caused by CO 2 poisoning. Here, in this study, we report our design of an active A-site Ca-rich high-entropy Pr 0.1875 Ba 0.1875 Sr 0.1875 La 0.1875 Ca 0.25 CoO 3-δ (PBSLC 25 C) electrode, guided by the O p-band theory. Here, when applied as a cathode in solid oxide fuel cells (SOFCs), it demonstrates high ORR activity and excellent CO 2 tolerance under realistic operating conditions. Ni-YSZ-based anode-supported cells with PBSLC 25 C cathodes demonstrate excellent peak power densities of 1.14 W cm -2 , 1.04 W cm -2 , and 0.77 W cm -2 in the air with 1%, 5%, and 10% CO 2 , respectively, at 750 °C. The engineered high-entropy PBSLC 25 C effectively diminishes the CO 2 poisoning effect and maintains active surfaces for fast oxygen exchange, as confirmed by the cell durability test in air containing CO 2 (5 and 10 vol%), Raman spectroscopy, and density functional theory calculations.

30 DIRECT ENERGY CONVERSION↗

Dusty Gas Model for Solid Oxide Fuel Cell Fuel Electrode

This model applies the Dusty Gas Model simulate multi-component species transport in SOFC (solid oxide fuel cell) anodes which considers the pressure gradient across the fuel electrode. This studyhas been verified with the analytical solution for different fuel electrode thicknesses and with literature values. The model was developed using the VoronoiFVM platform in Julia which is a built in implicit and semi implicit solver that integrates electrochemical behavior, microstructural effects, and transient analysis for accurate prediction of species transport under varying conditions.

dusty gas model (DGM)↗

Advanced Anode for Internal Reforming and Thermal Management in Solid Oxide Fuel Cells

Solid oxide fuel cell (SOFC) is an efficient and clean electrical power generation system compared to conventional combustion based technologies with energy efficiency reaching as high as 85-90% in co-generation mode (electricity and heat). Other advantages of SOFCs are hybridization, modularity of construction, small CO 2 foot print per kWh of generated electricity and fuel flexibility. Hydrocarbons present in the gaseous fuel is utilized in SOFCs by internal or external reforming. There are two different internal reforming concepts: Direct Internal Reforming (DIR) and Indirect Internal Reforming (IIR). For DIR operation, the endothermic reforming reaction and the exothermic reaction from the oxidation reaction are operated together in the single unit eliminating the requirement for a separate fuel reformer. This configuration also simplifies the overall system design, making SOFC more attractive and efficient means of producing electrical power. The main advantage of the DIR type of operation is that the H 2 or CO consumption by the electrochemical reaction could directly promote the conversion of methane at the anode side of the fuel cell resulting in high conversion and high efficiency. The DIR operation, however, requires an anode material that has desired dual catalytic (hetero and electro) properties for reforming reaction and electrochemical reactions. The anode materials also need to remain resistant to carbon formation at the operating temperature and atmosphere with stable cell performance. Another requirement is to match the reforming reactions and electrochemical reactions to avoid local cooling or overheating, which can result in mechanical failure due to thermally induced stresses. Direct internal reforming (DIR) of hydrocarbon fuels simplifies the overall SOFC system design making it more attractive and efficient for producing electrical power. Low cost alloy anodes for distributed internal reforming of methane and other hydrocarbon fuels offer increased fuel-flexibility, reliability, and long term performance stability of solid oxide fuel cells (SOFC). The research program examined modification of the chemical compositions and microstructure of high entropy alloy (HEA) anode materials using thermochemical calculations and process simulation and modeling to achieve distributed reforming over the entire anode to eliminate hot zones. Cell fabrication and testing of the HEA anodes using button cell configuration has been performed to demonstrate the advantages of new anode over traditional Ni-YSZ anodes for distributed reforming and carbon free operation. Technical accomplishments include identification and synthesis of HEA carbon-resistant anode, demonstration of reduction in reforming rate confirmed by GC and modelling data validating effectiveness for thermal management in cell/stacks, electrochemical testing of HEA anode in single cell (HEA-GDC||YSZ||LSM-YSZ) and Characterization of pretest and posttest anode materials by TEM and SEM-EDS confirming carbon-free operation.

30 DIRECT ENERGY CONVERSION↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

Investigating realistic anode off-gas combustion in SOFC/ICE hybrid systems: mini review and experimental evaluation

Solid oxide fuel cells (SOFCs) have been deployed in hybrid decentralized energy systems, in which they are directly coupled to internal combustion engines (ICEs). Prior research indicated that the anode tailgas exiting the SOFC stack should be additionally exploited due to its high energy value, with typical ICE operation favoring hybridization due to matching thermodynamic conditions during operation. Consequently, extensive research has been performed, in which engines are positioned downstream the SOFC subsystem, operating in several modes of combustion, with the most prevalent being homogeneous compression ignition (HCCI) and spark ignition (SI). Experiments were performed in a 3-cylinder ICE operating in the latter modus operandi, where the anode tailgas was assimilated by mixing syngas (H 2 : 33.9%, CO: 15.6%, CO 2 : 50.5%) with three different water vapor flowrates in the engine’s intake. While increased vapor content significantly undermined engine performance, brake thermal efficiency (BTE) surpassed 34% in the best case scenario, which outperformed the majority of engines operating under similar operating conditions, as determined from the conducted literature review. Nevertheless, the best performing application was identified operating under HCCI, in which diesel reformates assimilating SOFC anode tailgas, fueled a heavy duty ICE (17:1), and gross indicated thermal efficiency ([Formula: see text]) of 48.8% was achieved, with the same engine exhibiting identical performance when operating in reactivity-controlled compression ignition (RCCI). Overall, emissions in terms of NO x and CO were minimal, especially in SI engines, while unburned hydrocarbons (UHC) were non-existent due to the absence of hydrocarbons in the assessed reformates.

Engineering↗

Operating Stresses and Their Effects on Degradation of LSM-Based SOFC Cathodes

The performance of solid oxides fuel cells (SOFCs) with four different Mn excess of lanthanum strontium manganite (LSM) -based cathodes were examined under different temperatures (1,000 °C, 900 °C), current densities (0, 380, and 760 mA cm -2 ), and cathode atmospheres (p O 2 )=0.1,0.15,0.21) for durations ranging from 58 to 1,008 h. Each yttria-stabilized zirconia (YSZ) electrolyte-supported “button” cell had a porous Ni/YSZ composite anode and a porous LSM/YSZ composite cathode. The cells’ output voltage versus time were recorded and electrochemical impedance spectroscopy (EIS) and linear sweep voltammetry (LSV) measurements were performed every 24 hours. The total area specific resistance (ASR) was calculated from these measurements. The values of ASR from both EIS and LSV were comparable between each other but lower than that from durability test. Distribution of relaxation times (DRT) analysis was performed to investigate the electrochemical processes and their corresponding relaxation frequencies as well as their attributions to the total ASR. The series resistance and parallel resistance that obtained from the equivalent circuit fit of the Nyquist plot were higher at low temperature and low p O 2 regardless of LSM compositions. The area of the peaks derived from DRT analysis increased with time during individual tests. The microstructures of the tested cells were examined using scanning electron microscopy and energy-dispersive x-ray spectroscopy (SEM/EDS). Manganese oxide particles were observed near the cathode-electrolyte interface after prolonged (1,008 h) testing in air of a cell with LSM of 11% manganese excess, and after a short test (58 h) under low oxygen (p O 2 = 0.10) in a cell with LSM of 5% manganese excess. However, the role of MnOx in cell degradation is still unknown.

08 HYDROGEN↗

SOFC Prototype System Test

The goal of this U.S. Department of Energy (DOE) sponsored project is to test a 200 kWe thermally self-sustaining atmospheric-pressure solid oxide fuel cell (SOFC) prototype system at a prominent site. Fuel Cell Energy Inc. (FCE) utilized the state-of-the-art SOFC technology of its wholly-owned subsidiary Versa Power Systems (VPS) to design, fabricate and test the 200 kW prototype system. The specific objectives of this project were to achieve an SOFC stack power degradation rate of ≤1.5% per 1000 hours for the 400 kW stand-alone prototype power system undergoing ≥ 5000 hours of steady state tests at thermally self-sustained normal operating conditions (NOC), and to verify the prospects for a high volume SOFC stack production cost below the DOE target of 225 dollars per kilowatt. Achieving these goals enables commercial natural gas fueled SOFC system deployment in the 2020 timeframe, which will eventually lead to SOFC technology that is viable for large scale central power generation applications.

01 COAL, LIGNITE, AND PEAT↗

Cost-effective, Thin-film SOFCs for Reliable Power Generation (Final Report)

The project was aimed at developing and demonstrating an advanced solid-oxide fuel cell (SOFC) technology to cost-effectively and reliably generate electricity directly from hydrocarbon fuels (e.g., natural gas and coal-derived syngas) for distributed and central generation applications. The studied technology was built on a planar, porous metal-supported SOFC (MS-SOFC) with a unique thin-film structure having its anode intimately supported on a metal substrate. The porous metal support with graded porosity was fabricated from a low-cost scalable phase-inversion tape casting method. Anode, thin-film electrolyte, and cathode were sequentially deposited on the porous metal substrate using atmospheric plasma spray (APS). In this study, it was shown that the composition of the casting slurry could significantly influence the morphology of the metal support fabricated using the phase-inversion tape-casting method. Increasing the solid loading in the slurry favored the formation and growth of finger-like pores to a point, but the presence of excessive solid loading increased the viscosity of the casting slurry, restraining the growth of finger-like pores. With the increase in the amount of the binder polyethersulfone (PESf) in the slurry, well grown finger-like pores and a thin sponge-like layer were formed. Since the parameters of the APS process have a significant effect on the microstructure of coatings, which in turn affects or determines the SOFC cell performance, a series of metal-supported solid oxide fuel cells with a four-layer cell configuration of 430L/Ni-ScSZ/ScSZ/LSCF have been fabricated by a combination of phase inversion tape casting and APS techniques. Electrochemical testing of the cells fabricated from different deposition APS conditions revealed significant differences in cell performance.

30 DIRECT ENERGY CONVERSION↗

DEVELOPMENT OF OIL FREE CENTRIFUGAL BLOWER AS ENABLING TECHNOLOGY FOR SOLID OXIDE FUEL CELL ANODE GAS RECYCLING

Broad commercialization of solid oxide fuel cells (SOFCs), requires anode offgas recycle blowers (AORB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This work presents details of the development and testing of an oil-free, low cost centrifugal AORB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. The advantages of this novel technology are discussed, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology.

03 NATURAL GAS↗

SOC Microstructural Analyzer

This program was designed to analyze the 3-phase microstructure of the electrodes of a solid oxide fuel cell (SOFC) or electrolysis cell (SOEC), both referred to in combination as a solid oxide cell (SOC). It is agnostic to the exact system, so it could be repurposed to analyze any 3-phase microstructure. This tool directly analyzes segmented voxel-based data that has been segmented into phase IDs (1,2,3). The voxels will be analyzed directly for: - tortuosity factors - triple phase boundaries - 2-phase interfacial areas, using a meshed isosurface - mean diameters of each phase, using an inscribed sphere method - standard deviation of the diameters of each phase, from the same inscribed sphere data - connectivity information Comprehensive information is available in the readme file (within the zipped repository in Markdown language, and also available here as a rendered PDF). Please cite this page / DOI, as well as https://doi.org/10.1111/jace.14775, for usage.

3D microstructure↗

Next Generation Solid Oxide Fuel Cell Module Development

The overall objective of this project was to develop a transformative Solid Oxide Fuel Cell (SOFC) building block configuration comprised of multi-stack arrays that can be utilized in large-scale power plants. This transformative design signified the benefits of lower performance degradation coupled with improved reliability, low cost, smaller packaging for easier transport and installation, and improved maintenance and field serviceability characteristics. The project goal was to design and fabricate a scalable hot module for housing an array of SOFC stacks and to demonstrate the characteristics of the module gas distribution, insulation and instrumentation, and DC power take-off. The approach was to validate the design of a stack prototype scalable to megawatt (MW) class systems using FuelCell Energy’s Compact SOFC Architecture (CSA) stacks. The scope of work was intended to design, build, and test a compact and low-cost multi-stack sub-module with flexibility to house CSA stacks and scalable to 350 kW which could ultimately be deployed in construction of MW-class systems.

20 FOSSIL-FUELED POWER PLANTS↗

High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation

This report summarizes the work performed by University of California San Diego (UCSD) – Honeywell Aerospace (Honeywell) team for the U.S. Department of Energy/Advanced Research Projects Agency-Energy (DOE/ARPA-E) under Phase 1 (April 2021 – October 2023) project, Cooperative Agreement DE-AR0001347 entitled “High-Efficiency and Low-Carbon Energy Storage and Power Generation System for Electric Aviation”. The main objective of this project is to develop and demonstrate an energy storage and power generation (ESPG) system operating on bio liquid natural gas (LNG) for electric aviation applications. The ESPG system concept in this project is a fuel cell, battery, and gas turbine hybrid system that incorporates an innovative solid oxide fuel cell (SOFC) technology. This SOFC technology has two main novel elements: (i) a lightweight and compact stack architecture that consists of cells and cell modules in electrical parallel and series connections (the module design) and (ii) exceptionally high performance, direct methane thin-film cells on porous substrate made by sputtering deposition process. This fuel cell has the specific power and volumetric power density suitable for electric aviation applications. Based on the current status of the SOFC technology, the Phase 1 work focused on the following activities: (i) ESPG System Modeling – to design and optimize an aircraft SOFC-based ESPG system concept that met the performance, weight and cost targets; (ii) Cell Material Development and Scaleup – to demonstrate scalability of the sputtering process for manufacture of thin-film SOFC cells of practical sizes, confirm the exceptional performance of sputtered cells, improve cell stability and durability for operation with hydrogen and methane fuel, and develop a suitable electrically conducting porous substrate to replace the current non-conducting ceramic substrate; (iii) Stack Development – to design and manufacture stack components for the stack architecture, evaluate and select a suitable sealant, and build and operate multi-cell stacks to demonstrate stack operation, and (iv) Technology to Market – to develop business models and commercialization plans, conduct various market and technology analysis and estimate SOFC and ESPG system costs.

25 ENERGY STORAGE↗

Failure analysis of solid oxide fuel cells nickel-yttria stabilized zirconia anode under siloxane contamination

In this study, the failure process of the solid oxide fuel cell (SOFC) Ni-yttria-stabilized zirconia (YSZ) anode is investigated with D4 siloxane (octamethylcyclotetrasiloxane) contamination. In order to evaluate the influence of the electrochemical reaction on the siloxane deposition process, the SOFC experiments were operated at open circuit voltage (OCV) and 50 mA cm -2 conditions at 800°C. During the failure process, electrochemical, morphology and exhaust gas component analysis testing are conducted at the critical points. An equivalent circuit model and corresponding microstructure parameter calculations for separated physicochemical processes were utilized for the quantitative analysis of the failure process. Further, the results confirm the siloxane chemical adsorption deposition mechanism proposed in previous work. As a result, the failure of the anode was attributed to the gas diffusion blockage by dense silicon dioxide layer formation. The anode failure process with siloxane contamination is faster when the anode is operated under polarization.

25 ENERGY STORAGE↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and OxEon Energy LLC (Abstract)

The National Energy Technology Laboratory (NETL) will collaborate with OxEon Energy LLC (OxEon) to apply NETL’s patented single step electrode infiltration technique on OxEon solid oxide fuel cells (SOFC) for Electric Vertical Takeoff and Landing (eVTOL) aircraft applications below one megawatt. The expanded application of the OxEon solid oxide cell technology on eVTOL aircraft seeks to demonstrate a high performance, durable SOFC system that will produce more electricity per weight based on possible operation on ammonia as fuel. NETL’s single-step electrode infiltration technique addresses these challenges by introducing a highly active nanocatalyst material into the SOFC electrode microstructure to improving cell performance, longevity, and fuel flexibility. Specifically for this project, OxEon will incorporate NETL’s technology to generate a small stack of cells (1 kW output) to demonstrate a fuel flexible system at a relevant scale. NETL will apply its infiltration technology to cells supplied by OxEon, test the effectiveness of the infiltration internally at NETL based on performance in hydrogen, and then supply infiltrated cells to OxEon and Pacific Northwest National Laboratory for independent confirmation and for the 1 kW stack test.

30 DIRECT ENERGY CONVERSION↗

Review—(Mn,Co) 3 O 4 -Based Spinels for SOFC Interconnect Coating Application

With the reduction of solid oxide fuel cell (SOFC) operating temperature to the range of 600 °C–800 °C, Cr-containing ferritic alloys have become the preferred interconnect material, which unfortunately are susceptible to continuous scale growth and Cr volatility at the SOFC operating temperatures. The (Mn,Co) 3 O 4 spinel system is widely regarded as the most effective coating for SOFC interconnect protection, due to its high thermal and electrical conductivity, adequate coefficient of thermal expansion, and excellent Cr blocking capability. This article reviews the physical and chemical properties of the (Mn,Co) 3 O 4 -based spinels; different types of coating precursors and deposition techniques; and the effects of spinel composition, quality and thickness on the coating performance. Furthermore, it is concluded that the spinel coating composition, quality, and thickness are more critical than the coating process in affecting the overall coating performance.

08 HYDROGEN↗

Degradation Comparison of Cyclic and Linear Siloxane Contamination on Solid Oxide Fuel Cells Ni-YSZ Anode

The solid oxide fuel cell (SOFC) nickel-yttria stabilized zirconia (Ni-YSZ) anode degradation due to different types of siloxane contamination is investigated. A cyclic structure siloxane, octamethylcyclotetrasiloxane (D4), and a linear structure siloxane, decamethyltetrasiloxane (L4), are mixed with H 2 +N 2 as the fuel for SOFCs at 750°C. The electrochemical characterization results after stability experiments suggest that the SOFC contaminated with cyclic siloxane, D4, had higher degradation. Pure YSZ pellets with different surface hydroxylation extents were also tested to investigate the D4/L4 adsorption and deposition process. Postmortem SEM/WDS, XRD and Raman analysis all indicate that cyclic siloxane has more deposition than linear siloxane on the anode. Further analysis demonstrates that high adsorption and low desorption rates of cyclic siloxane on YSZ are linked to the degradation. Besides the silicon deposition, SiC and amorphous carbon deposition were also observed from the XRD and Raman analysis.

25 ENERGY STORAGE↗

The anode supported internal cathode tubular solid oxide fuel cell: Novel production of a cell geometry for combined heat and power applications

An effective strategy for generating combined heat and power (CHP) systems is to use the combustion of hydrocarbons to provide fuel reforming and heat production for solid oxide fuel cell (SOFC) operation. Though tubular SOFCs (tSOFCs) are well suited to the thermal cycling associated with combustion systems, they have a geometric limitation which requires significant alteration to the combustion chamber. These alterations can be eliminated by producing an anode supported internal cathode-tSOFC (IC-tSOFC) which can be directly integrated into the chamber with minimal alterations. Novel methods used to produce IC-tSOFCs are discussed in this work. Scanning electron microscopy (SEM) and performance characterization are used to analyze fabricated cells. Finally, with a peak power density of 369 mW∙cm –2 , and an open circuit voltage (OCV) of 0.98 V, it is confirmed that novel production methods for IC-tSOFCs have been successful.

08 HYDROGEN↗

Effects of Synthesis Gas Concentration, Composition, and Operational Time on Tubular Solid Oxide Fuel Cell Performance

There is tremendous potential to utilize the exhaust gases and heat already present within combustion chambers to generate electrical power via solid oxide fuel cells (SOFCs). Variations in system design have been investigated as well as thorough examinations into the impacts of environmental conditions and fuel composition/concentration on SOFC performance. In an attempt to isolate the impacts of carbon monoxide and hydrogen concentration ratios within the exhaust stream, this work utilizes multi-temperature performance analyses with simulated methane combustion exhaust as fuel combined with dilute hydrogen baseline tests. These comparisons reveal the impacts of the complex reaction pathways carbon monoxide participates in when used as an SOFC fuel. Despite these complexities, performance reductions as a result of the presence of carbon monoxide are low when compared to similarly dilute hydrogen as a fuel. This provides further motivation for the continued development of SOFC-CHP systems. Stability testing performed over 80 h reveals the need for careful control of the operating environment as well as signs of carbon deposition. As a result of gas flow disruption, impacts of anode oxidation that may normally not hinder power production become significant factors in addition to coarsening of the anode material. Thermal management and strategies to minimize these impacts are a topic of future research.

54 ENVIRONMENTAL SCIENCES↗