Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solvent-based separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

Delamination recycling of multilayer plastic films: Solvent-assisted separation pathways and recovery of solid polyolefins

Multilayer plastic films are excellent packaging materials due to the bound layers of multiple polymers, with each different polymer contributing to the film properties. Desirable properties lead to continuously growing demand for multilayer films. Multilayer plastic films are typically single-use and, as such, their increased production and disposal have led to waste management problems. Multilayer films are not currently recyclable primarily due to the multiple bound polymers. This work advances delamination as a recycling process to separate and sequester valuable polymers from multilayer films, facilitating the incorporation of these polymers into the circular economy. We effect delamination in a physical process that preserves targeted polymers as solid film, hence retaining their embodied energy. This work documents three different pathways of inducing delamination of multilayer films, with appropriate solvents disrupting adhesion between adjacent layers or dissolving a minor component of the film in less than an hour and at temperatures below 90°C, and where all initial polyethylene is maintained in its solid form throughout the process and is recovered at high purity. Solvent-based delamination is exemplified on commercial multilayer films with majority polyethylene (PE), and polyethylene terephthalate (PET) or ethylene vinyl alcohol copolymer (EVOH) or nylon also present. Solvent-based delamination is an energy-efficient and environmentally friendly recycling process that improves upon dissolution-precipitation recycling, since delamination involves very little dissolution and no precipitation, and is superior to pyrolysis which breaks down the polymers, while delamination keeps polymer chains intact. Furthermore, delamination recycling can contribute to the sustainable use of multilayer films as they continue to protect our food and medicine.

Chemical Recycling↗

Atomic Layer Deposition for Materials-Based H2 Storage: Opportunities and Limitations

The transportation demands in our growing hydrogen (H2) economy requires robust storage systems. The current commercially implemented technology in fuel cell cars relies on the well-established technology of hydrogen gas compressed to 350-700 bar, depending on the application. The compressed gas tanks in use today are bulky and cost intensive. To address this challenge, material-based storage is one of the long-term alternatives considered and constitutes the focus of this talk. Material-based storage is broadly defined as hydrogen bound to solid materials, with its binding strength varying from physisorption to porous materials, such as zeolites and metal organic frameworks, to chemisorption in (complex) metal hydrides. The ultimate targets set by the U.S. Department of Energy for this technology include a system gravimetric capacity of 6.5 wt% and volumetric capacity of 40 g/L at 100 bar, operating temperatures ranging between -40 C and +40 C and adsorption/desorption timescales of < 5 min. Storage in the form of physisorbed or chemisorbed hydrogen has guided the materials research, which metal- organic framework and (complex) metal hydrides being the most promising materials classes. A variety of these materials have met one or more of the targets, but it has remained elusive for a single material system to meet all these stringent requirements. Nano-encapsulation and low-concentration chemical additives have previously been employed separately to overcome such challenges. Functionalization via atomic layer deposition (ALD), however, offers unique characteristics that make it suitable for both, nano-encapsulation and "doping" with low-concentration additives. This deposition technique has sub-monolayer thickness control, is highly conformal in high-surface area materials and is self-limiting, i.e., once the gas-phase precursor reacts with the available surface sites, the surface reactions stop. In this presentation, we will showcase examples where ALD, more generally vapor-phase functionalization, on (complex) metal hydrides and organic frameworks has improved the material properties for H2 storage. In our first study, Al2O3 was deposited on magnesium borohydride, Mg(BH4)2, at room temperature using trimethylaluminum (TMA) and water. From our findings, encouraging initial results were obtained: the H2 desorption temperature was lowered by 60-120 degrees C, the desorbed gravimetric H2 capacity at temperatures < 250 degrees C was doubled, and the desorption kinetics increased by a factor of ~6 compared to uncoated Mg(BH4)2. However, hydrolysis reactions caused by residual surface -OH groups from the ALD water-pulse degraded the sample substantially. Through this study, the use of TMA was observed to be highly reactive with the Mg(BH4)2 surface species, leading to the strategy of exposing the sample only to TMA. The relative mole fraction of the vapor-phase additive can be precisely controlled with the number of TMA pulses and pulse duration. By tuning these parameters, we show in our second study that 10 pulses of TMA at ambient conditions were able to decrease the H2 desorption temperature by ~100 degrees C while retaining <95 % of its H2 capacity. We applied this approach with other additives such as BBr3, TiCl4 and tetrahydrofuran, and demonstrate that this unique approach opens the door to a new class of molecular additives and catalysts which cannot easily be introduced with conventional mechano-chemical or solvent-based techniques for (complex) metal-hydrides. In the case of metal organic frameworks, ALD is a promising technique to functionalize the pores with metal atoms or functional groups able to tune the gas selectivity and binding energy, for which ~15 kJ/mol has been established as the optimal value for H2 storage in sorbent materials. Vapor-phase techniques such as ALD have numerous benefits over other functionalization tools for H2 storage materials opening innumerable opportunities to the field. To exploit these opportunities, the current limitations on room temperature and water-less ALD processes needs to be overcome which will greatly expand the possibilities of encapsulation and incorporation of additives for organic frameworks and (complex) metal hydrides.

atomic layer deposition↗

Toward High Efficiency Water Processed Organic Photovoltaics: Controlling the Nanoparticle Morphology with Surface Energies

Here efficient organic photovoltaic devices fabricated from water-based colloidal dispersions with donor:acceptor composite nanoparticles achieving up to 9.98% power conversion efficiency (PCE) are reported. This high efficiency for water processed organic solar cells is attributed to morphology control by surface energy matching between the donor and the acceptor materials. Indeed, due to a low interfacial energy between donor and the acceptor, no large phase separation occurs during the nanoparticle formation process as well as upon thermal annealing. Indeed, synchrotron-based scanning transmission X-ray microscopy reveals that the internal morphology of composite nanoparticles is intermixed as well as the active layer morphology after thermal treatment. The PCE of this system reaches 85% that of devices prepared from chlorinated solvent. The gap between water-based inks and organic solvent-based inks gets narrower, which is promising for the development of eco-friendly processing and fabrication of organic photovoltaics.

14 SOLAR ENERGY↗

Extraction of Pure Plastic Resins From PCR Plastic Waste by Solvent-Targeted Recovery and Precipitation (STRAP)

For this work, we have been developing a solvent‐based plastic recycling technology called STRAP. The technology is based on dissolving a targeted plastic resin in a specific solvent that does not dissolve other resins. We have demonstrated STRAP in thousands of bench scale experiments for a large variety of wastes. Recently we have demonstrated the technology for PCR, using mixed plastic wastes (MPWs), from a wet Material Recovery Facility (MRF). The process includes (1) infrared (IR) characterization to determine the plastic composition for accurate selection of the solvent to be used for the extraction of the pure resins. (2) Shredding to the right size and aspect ratio required for flowable and fast dissolvable process. (3) Mixing the MPW in the first solvent to dissolve the first resin. (4) Filtration of the solution plastic blend, to separate the nondissolved plastic from the solution. (5) Further filtration of the solution to remove micron‐sized particle of pigments and fibers. (6) Cooling for precipitation. (7) Filtration of pure resins. (8) Drying of a pure resin. (9) Extrusion of the resin to pellets. (10) Generating films or other products from the pure resin. Steps 1–10 can be considered as one‐cycle that extracted the first resin. (11) A second resin can be extracted with a respective solvent from the plastic that did not dissolve in the first cycle and following steps 1–10 described above. The process also includes characterization of interim and final products. The effort includes building a pilot system at 25 kg/h throughput. We will present specific results for various PCR.

IR characterization↗

Techno-economic analysis of carbon dioxide capture from low concentration sources using membranes

Rising carbon dioxide (CO 2 ) levels in the atmosphere lead to global warming, causing climate change. As such, carbon capture has become necessary to slow the increase and reduce CO 2 levels in the atmosphere. Point source emissions have a wide range of CO 2 concentrations, but emissions below 3% CO 2 have mostly been ignored because Carbon capture from these sources has been viewed as costly and economically unsustainable. Membrane technologies are considered the most viable solution by virtue of more energy-efficient operation. Our group at Idaho National Laboratory (INL) has developed poly[bis((2-methoxyethoxy)ethoxy)phosphazene] (MEEP)-based carbon dioxide selective membranes with CO 2 /N 2 selectivity greater than 40 and CO 2 permeability greater than 450 Barrer. To understand the economics of carbon capture, a spreadsheet-based techno-economic analysis (TEA) model was developed to consider multiple parameters, including selectivity and permeability of the membranes, performance conditions such as the number of stages, module material, electricity price, membrane price, and capital financing. The cost of carbon capture in US $\$$/metric ton was calculated at various purities and compared with other membrane processes, cryogenic capture, solvent-based capture, and pressure swing adsorption-based capture. It was determined that a MEEP-based three-stage process had a capture cost of US $\$$ 50.1/metric ton for 99.8% purity CO 2 from a 1% CO 2 feed source in nitrogen (N 2 ). In conclusion, the capture cost using the best performing Pebax-based membrane was 464% higher, cryogenic capture was 60%–140% higher, pressure swing adsorption was 55%–165% higher, and chemical absorption was -10%–110% higher than MEEP-based membrane capture, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass transfer intensification through increased surface wetting and liquid turbulence using 3D printing structured packing for CO2 capture

The absorber column is one of the most expensive pieces of equipment to construct in the solvent-based post-combustion carbon capture unit. In order to decrease the absorber size and reduce capital costs, novel polymer packings were proposed by enhancing surface wettability and local turbulence within liquid solvent. The novel packings intensify the mass transfer in CO2 absorption and show better separation efficiency than traditional structured packings. In this work, the economic influence of applying the more efficient packing with a shorter absorber column is studied in a techno-economic analysis for a carbon capture unit at a coal-fired power plant. The baseline case includes CO2 capture unit in a supercritical pulverized coal power plant to generate 650 MWe (net) of electricity, where the additional CO2 capture unit leads to 63.4% increase of LCOE. While implementing UK PCC with traditional and novel packings, there will be 47.2% and 46.4% LCOE increase separately, both of which are lower than the baseline value. Applying more efficient packing and smaller absorber could further lessen the LCOE increase. The UK PCC with traditional packings reduces CO2 capture cost by 23.4% and the application of the advanced packings allows to the reduction increases to 24.4%.

60 APPLIED LIFE SCIENCES↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

A Modular Oxygen-Selective System for Combustion Systems

Small-scale modular systems for oxygen generation offer clear benefits, including improved energy efficiency, reduced operating costs, and the flexibility to meet location-specific needs. We propose that a compact modular system could be developed using a solvent-based method for capturing and releasing oxygen, enabling “oxygen on demand” for various combustion technologies. In this project, we aim to develop and demonstrate a modular oxygen-selective approach based on Battelle IPID 31740. The use of designer solvents, which are reversible, single-component solvents capable of dissolving and separating oxygen from air, offers the advantage of unlimited chemical tunability to achieve desirable properties for efficient oxygen separation. We filed U.S. Patent (32845-E, iEdison No. 0685901-23-0184).

36 MATERIALS SCIENCE↗

Life Cycle Assessment of Innovative Carbon Dioxide Selective Membranes from Low Carbon Emission Sources: A Comparative Study

Carbon capture has been an important topic of the twenty-first century because of the elevating carbon dioxide (CO2) levels in the atmosphere. CO2 in the atmosphere is above 420 parts per million (ppm) as of 2022, 70 ppm higher than 50 years ago. Carbon capture research and development has mostly been centered around higher concentration flue gas streams. For example, flue gas streams from steel and cement industries have been largely ignored due to lower associated CO2 concentrations and higher capture and processing costs. Capture technologies such as solvent-based, adsorption-based, cryogenic distillation, and pressure-swing adsorption are under research, but many suffer from higher costs and life cycle impacts. Membrane-based capture processes are considered cost-effective and environmentally friendly alternatives. Over the past three decades, our research group at Idaho National Laboratory has led the development of several polyphosphazene polymer chemistries and has demonstrated their selectivity for CO2 over nitrogen (N2). Poly[bis((2-methoxyethoxy)ethoxy)phosphazene] (MEEP) has shown the highest selectivity. A comprehensive life cycle assessment (LCA) was performed to determine the life cycle feasibility of the MEEP polymer material compared to other CO2-selective membranes and separation processes. The MEEP-based membrane processes emit at least 42% less equivalent CO2 than Pebax-based membrane processes. Similarly, MEEP-based membrane processes produce 34–72% less CO2 than conventional separation processes. In all studied categories, MEEP-based membranes report lower emissions than Pebax-based membranes and conventional separation processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗