Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source Term Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Computational modeling and validation of a modified Marple cascade impactor

Oak Ridge National Laboratory (ORNL) is investigating respirable aerosol fractions from failed high-burnup (HBU) commercial spent nuclear fuel (CSNF) rods (Montgomery et al., 2022). The work aims to characterize the source term of radioactive aerosols that could result from mechanical failure and handling of failed fuel rods during storage and/or transportation. The experiment involves capturing and characterizing aerosols from a four-point bending experiment of fueled rod segments at ORNL’s Irradiated Fuels Examination Laboratory (IFEL). For this, a Marple cascade impactor (Series 290) with the ability to collect particles up to aerodynamic equivalent diameters of ~15 μm was tested for feasibility. The commercially available Marple cascade impactor design was modified for the experiment, where the cascade inlet was replaced with a 3D printed inlet nozzle. Collection efficiency curves were then generated with the modified impactor, and the cascade’s performance was tested using ISO dust capture experiments followed by SEM analysis of the collection and computational modeling. The current work highlights the performance testing and experimental validation of this modified Marple Impactor for spent nuclear fuel aerosol collection.

Kumar, Vineet↗

Advanced Modeling and Simulation to Characterize Advanced Boiling Water Reactor Source Terms to Support a Regulatory Approval Pathway for Right-Sized Emergency Planning Zone. Advanced Boiling Water Reactor (A-BWR) Project Phase 2

The United States Department of Energy (US DOE) is currently supporting the development of various small modular reactor (SMR), microreactor and advanced reactor designs. These reactors have improved safety features as compared to conventional Large Light Water Reactors (LLWRs), which include features that improve potential reduction of radiological source terms in the event of design and beyond-design basis accidents. Specifically, some reactors feature a relatively smaller containment volume with respect to the available surface area for fission product deposition; these include Integrated Pressurized Water Reactors (iPWRs), such as the NuScale SMR and SMR-type Boiling Water Reactors (BWRs) such as General Electric-Hitachi’s BWRX-300 design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimetric characterization of the GammaClip™{sup 169}Yb low dose rate permanent implant brachytherapy source for the treatment of nonsmall cell lung cancer postwedge resection

Purpose: A novel {sup 169}Yb low dose rate permanent implant brachytherapy source, the GammaClip™, was developed by Source Production and Equipment Co. (New Orleans, LA) which is designed similar to a surgical staple while delivering therapeutic radiation. In this report, the brachytherapy source was characterized in terms of “Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO” by Perez-Calatayud et al. [Med. Phys. 39, 2904–2929 (2012)] using the updated AAPM Task Group Report No. 43 formalism.Methods: Monte Carlo calculations were performed using Monte Carlo N-Particle 5, version 1.6 in water and air, the in-air photon spectrum filtered to remove photon energies below 10 keV in accordance with TG-43U1 recommendations and previously reviewed {sup 169}Yb energy cutoff levels [D. C. Medich, M. A. Tries, and J. M. Munro, “Monte Carlo characterization of an Ytterbium-169 high dose rate brachytherapy source with analysis of statistical uncertainty,” Med. Phys. 33, 163–172 (2006)]. TG-43U1 dosimetric data, including S{sub K}, D-dot (r,θ), Λ, g{sub L}(r), F(r, θ), φ{sub an}(r), and φ{sub an} were calculated along with their statistical uncertainties. Since the source is not axially symmetric, an additional set of calculations were performed to assess the resulting axial anisotropy.Results: The brachytherapy source's dose rate constant was calculated to be (1.22 ± 0.03) cGy h{sup −1} U{sup −1}. The uncertainty in the dose to water calculations, D-dot (r,θ), was determined to be 2.5%, dominated by the uncertainties in the cross sections. The anisotropy constant, φ{sub an}, was calculated to be 0.960 ± 0.011 and was obtained by integrating the anisotropy factor between 1 and 10 cm using a weighting factor proportional to r{sup −2}. The radial dose function was calculated at distances between 0.5 and 12 cm, with a maximum value of 1.20 at 5.15 ± 0.03 cm. Radial dose values were fit to a fifth order polynomial and dual exponential regression. Since the source is not axially symmetric, angular Monte Carlo calculations were performed at 1 cm which determined that the maximum azimuthal anisotropy was less than 8%.Conclusions: With a higher photon energy, shorter half-life and higher initial dose rate {sup 169}Yb is an interesting alternative to {sup 125}I for the treatment of nonsmall cell lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE NANOGRAV NINE-YEAR DATA SET: OBSERVATIONS, ARRIVAL TIME MEASUREMENTS, AND ANALYSIS OF 37 MILLISECOND PULSARS

We present high-precision timing observations spanning up to nine years for 37 millisecond pulsars monitored with the Green Bank and Arecibo radio telescopes as part of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) project. We describe the observational and instrumental setups used to collect the data, and methodology applied for calculating pulse times of arrival; these include novel methods for measuring instrumental offsets and characterizing low signal-to-noise ratio timing results. The time of arrival data are fit to a physical timing model for each source, including terms that characterize time-variable dispersion measure and frequency-dependent pulse shape evolution. In conjunction with the timing model fit, we have performed a Bayesian analysis of a parameterized timing noise model for each source, and detect evidence for excess low-frequency, or “red,” timing noise in 10 of the pulsars. For 5 of these cases this is likely due to interstellar medium propagation effects rather than intrisic spin variations. Subsequent papers in this series will present further analysis of this data set aimed at detecting or limiting the presence of nanohertz-frequency gravitational wave signals.

79 ASTRONOMY AND ASTROPHYSICS↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scoping Analysis of Source Term and Functional Containment Attenuation Factors

In order to meet future regulatory requirements, the Next Generation Nuclear Plant (NGNP) Project must fully establish and validate the mechanistic modular high temperature gas-cooled reactor (HTGR) source term. This is not possible at this stage in the project, as significant uncertainties in the final design remain unresolved. In the interim, however, there is a need to establish an approximate characterization of the source term. The NGNP team developed a simplified parametric model to establish mechanistic source term estimates for a set of proposed HTGR configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scoping Analysis of Source Term and Functional Containment Attenuation Factors (Revision 1)

In order to meet future regulatory requirements, the Next Generation Nuclear Plant (NGNP) Project must fully establish and validate the mechanistic modular high temperature gas-cooled reactor (HTGR) source term. This is not possible at this stage in the project, as significant uncertainties in the final design remain unresolved. In the interim, however, there is a need to establish an approximate characterization of the source term. The NGNP team developed a simplified parametric model to establish mechanistic source term estimates for a set of proposed HTGR configurations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beam emittance measurements and simulations of injector line for radio frequency quadrupole

A 400 keV deuteron (D{sup +}) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H{sup +} and D{sup +} beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D{sup +} beam through the RFQ, while 95% transmission has been measured experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental characterization of hot-electron emission and shock dynamics in the context of the shock ignition approach to inertial confinement fusion

We report on planar target experiments conducted on the OMEGA-EP laser facility performed in the context of the shock ignition (SI) approach to inertial confinement fusion. The experiment aimed at characterizing the propagation of strong shock in matter and the generation of hot electrons (HEs), with laser parameters relevant to SI (1-ns UV laser beams with I ~10 16 W/cm 2 ). Time-resolved radiographs of the propagating shock front were performed in order to study the hydrodynamic evolution. The hot-electron source was characterized in terms of Maxwellian temperature, T h , and laser to hot-electron energy conversion efficiency η using data from different x-ray spectrometers. The post-processing of these data gives a range of the possible values for T h and η [i.e., T h [keV] ϵ (20, 50) and η ϵ (2%, 13%)]. These values are used as input in hydrodynamic simulations to reproduce the results obtained in radiographs, thus constraining the range for the HE measurements. According to this procedure, we found that the laser converts ~10% ± 4% of energy into hot electrons with T h = 27 ± 8 keV. The paper shows how the coupling of different diagnostics and numerical tools is required to sufficiently constrain the problem, solving the large ambiguity coming from the post-processing of spectrometers data. The effect of the hot electrons on the shock dynamics is then discussed, showing an increase in the pressure around the shock front. Furthermore, the low temperature found in this experiment without pre-compression laser pulses could be advantageous for the SI scheme, but the high conversion efficiency may lead to an increase in the shell adiabat, with detrimental effects on the implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A critical review of principal traffic noise models: Strategies and implications

The paper presents an exhaustive comparison of principal traffic noise models adopted in recent years in developed nations. The comparison is drawn on the basis of technical attributes including source modelling and sound propagation algorithms. Although the characterization of source in terms of rolling and propulsion noise in conjunction with advanced numerical methods for sound propagation has significantly reduced the uncertainty in traffic noise predictions, the approach followed is quite complex and requires specialized mathematical skills for predictions which is sometimes quite cumbersome for town planners. Also, it is sometimes difficult to follow the best approach when a variety of solutions have been proposed. This paper critically reviews all these aspects pertaining to the recent models developed and adapted in some countries and also discusses the strategies followed and implications of these models. - Highlights: • Principal traffic noise models developed are reviewed. • Sound propagation algorithms used in traffic noise models are compared. • Implications of models are discussed.

54 ENVIRONMENTAL SCIENCES↗

A multi-sheath model for highly nonlinear plasma wakefields

An improved description for nonlinear plasma wakefields with phase velocities near the speed of light is presented and compared against fully kinetic particle-in-cell simulations. These wakefields are excited by intense particle beams or lasers pushing plasma electrons radially outward, creating an ion bubble surrounded by a sheath of electrons characterized by the source term S≡−1enp(ρ−Jz/c), where ρ and Jz are the charge and axial current densities, respectively. Previously, the sheath source term was described phenomenologically with a positive-definite function, resulting in a positive definite wake potential. In reality, the wake potential is negative at the rear of the ion column which is important for self-injection and accurate beam loading models. To account for this, we introduce a multi-sheath model in which the source term, S, of the plasma wake can be negative in regions outside the ion bubble. Using this model, we obtain a new expression for the wake potential and a modified differential equation for the bubble radius. Numerical results obtained from these equations are validated against particle-in-cell simulations for unloaded and loaded wakes. The new model provides accurate predictions of the shape and duration of trailing bunch current profiles that flatten plasma wakefields. It is also used to design a trailing bunch for a desired longitudinally varying loaded wakefield. We present beam loading results for laser wakefields and discuss how the model can be improved for laser drivers in future work. Finally, we discuss differences between the predictions of the multi- and single-sheath models for beam loading.

Dalichaouch, T. N. (ORCID:0000000247350150)↗

Development of Waste Inventory for Probabilistic Performance Assessment Modeling - 19361

Estimation of radioactive waste inventory is a key initial step in the development of an environmental fate and transport model for performance assessment (PA) of radioactive waste sites. PA model output is often sensitive to parameters that represent inventory as a source term, yet estimation is a difficult problem. Inventory estimation for a probabilistic performance assessment (PPA) is related to, but distinct from, that performed for waste excavation, characterization, and offsite disposal. The latter appropriately focuses on obtaining the most detailed information possible on specific hazards and locations; however, these questions cannot be fully answered without intrusive site characterization efforts. This type of characterization is often not feasible when assembling information regarding a source term in a PPA model. Development of waste inventory for a PPA is one piece of a larger hierarchical model. The physical process model represented by Goldsim computer code represents one level of the hierarchy, and the second level of the hierarchy involves estimation of inputs such as inventory, transport, and risk parameters. The estimation of inputs is not a straightforward problem. The parameters of a computer model often do not have an equivalence to the physical quantities they describe, and estimation of the physical quantities themselves can be difficult due to limitations of available information. Inventory information for the West Valley Site in upstate New York is based on data from historical shipping and disposal forms. In the 1990's, the West Valley Demonstration Project (WVDP) compiled information from existing databases and historical waste records into one complete modern database. A conceptual model was then applied and used with recorded information to characterize the waste mass and radionuclide composition for each waste burial. Information was ultimately aggregated over all waste records to estimate the mass of each radionuclide within each trench, hole, or caisson. Three decades later, we revisit the master database, make updates with newly-identified information, and incorporate the conceptual model previously used for inventory estimation in the hierarchical modeling framework. We characterize uncertainty using probability distributions for waste mass and radionuclide composition at the individual shipment or individual burial level. Uncertainty incorporated at the lowest level of the hierarchy is ultimately carried through to uncertainty in PPA model endpoints. Sensitivity analysis of early model results is then applied to identify influential inputs and guide subsequent efforts towards parameters that drive risk. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring Spatial Variability of Vapor Flux to Characterize Vadose-zone VOC Sources: Flow-cell Experiments

A method termed vapor-phase tomography has recently been proposed to characterize the distribution of volatile organic contaminant mass in vadose-zone source areas, and to measure associated three-dimensional distributions of local contaminant mass discharge. The method is based on measuring the spatial variability of vapor flux, and thus inherent to its effectiveness is the premise that the magnitudes and temporal variability of vapor concentrations measured at different monitoring points within the interrogated area will be a function of the geospatial positions of the points relative to the source location. A series of flow-cell experiments was conducted to evaluate this premise. A well-defined source zone was created by injection and extraction of a non-reactive gas (SF6). Spatial and temporal concentration distributions obtained from the tests were compared to simulations produced with a mathematical model describing advective and diffusive transport. Tests were conducted to characterize both areal and vertical components of the application. Decreases in concentration over time were observed for monitoring points located on the opposite side of the source zone from the local–extraction point, whereas increases were observed for monitoring points located between the local–extraction point and the source zone. We found that the results illustrate that comparison of temporal concentration profiles obtained at various monitoring points gives a general indication of the source location with respect to the extraction and monitoring points.

54 ENVIRONMENTAL SCIENCES↗

Application of the ORIGEN Fallout Analysis Tool and the DELFIC Fallout Planning Tool to National Technical Nuclear Forensics

The objective of this project was to provide a robust fallout analysis and planning tool for the National Technical Nuclear Forensics interagency ground sample collection team. Their application called for a fast-running, portable mission-planning tool for use in response to emerging improvised nuclear device (IND) post-detonation situations. The project met those goals by research and development of models to predict the physical, chemical, and radiological properties of fallout debris. ORNL has developed new graphical user interfaces for two existing codes, the Oak Ridge Isotope Generation (ORIGEN) code and the Defense Land Fallout Interpretive Code (DELFIC). ORIGEN is a validated, radionuclide production and decay code that has been implemented into the Fallout Analysis Tool to predict the fallout source term nuclide inventory after the detonation of an IND. DELFIC is a validated, physics-based, research reference fallout prediction software package. It has been implemented into the Fallout Planning Tool and is used to predict the fractionated isotope concentrations in fallout, particle sizes, fractionation ratios, dose rate, and integrated dose over the planned collection routes - information vital to ensure quality samples for nuclear forensic analysis while predicting dose to the sample collectors. DELFIC contains a particle activity module, which models the radiochemical fractionation of the elements in a cooling fireball as they condense into and onto particles to predict the fractionated activity size distribution for a given scenario. This provides the most detailed physics-based characterization of the fallout source term phenomenology available in an operational fallout model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ongoing characterization of the forced electron beam induced arc discharge ion source for the selective production of exotic species facility

An intense research and development activity to finalize the design of the target ion source system for the selective production of exotic species (SPES) facility (operating according to the isotope separation on line technique) is at present ongoing at Legnaro National Laboratories. In particular, the characterization of ion sources in terms of ionization efficiency and transversal emittance is currently in progress, and a preliminary set of data is already available. In this work, the off-line ionization efficiency and emittance measurements for the SPES forced electron beam induced arc discharge ion source in the case of a stable Ar beam are presented in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated program for department of energy environmental management office of soil and groundwater remediation - 15426

The subsurface problems that remain at the U.S. Department of Energy (DOE) Office of Environmental Management (EM) sites are technically complex and the costs to complete the cleanup mission are expected to range from $17 billion to $21 billion. There is growing recognition that conventional remedies will not meet regulatory goals at a number of sites and alternative approaches will be required. To address the challenge, the EM Office of Soil and Groundwater Remediation created an integrated program to develop innovative scientific and technical in conjunction with engagement of stakeholders, regulators, and the public. The integrated program provides a holistic approach to assess the risk associated with the remaining challenges facing EM and develop solutions that achieve remediation goals and protect human health and the environment. The integrated program uses a systems-based framework for achieving environmental remediation goals. The framework is based on developing and updating a site conceptual model and includes steps to 1) provide the technical basis for remedial actions, 2) assessments of potential remedies, and 3) implementation and management of remedies to achieve site restoration goals. The Office of Soil and Groundwater remediation defines research and development needed to successfully define and apply the framework. Research opportunities and targets are identified in characterization and conceptual model development, predictions of site conditions, remediation, monitoring, and remediation decision support. Characterization and quantification of key subsurface uncertainties is needed to support conceptual model development, identify contaminant source zones, quantify the flux of contaminants from source terms to points of compliance, and characterize controlling processes for remediation approaches including natural attenuation. Predictive analyses are needed to support development of remediation endpoints, select and design active and in situ or passive remedies, assess remedy performance, and predict long-term contaminant behavior for design of monitoring systems. Advancements are needed to support adaptive remediation approaches and to develop long-term contaminant management strategies for complex sites, such as effective in situ treatment methods for long-lived contaminants ({sup 99}Tc, {sup 129}I, U, Hg, etc.). Monitoring tools and approaches are needed to evaluate remedy performance and plume behavior and decision support methods are needed to quantitatively evaluate remediation alternatives. The Office of Soil and Groundwater Remediation leverages scientific understanding provided through partnerships with the DOE Office of Science, the Department of Defense, and Environmental Protection Agency. These partnerships are helping EM develop scientific understanding and technologies for implementing the assessment framework. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗